Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Transplant ; 34(3): e13801, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31999865

RESUMO

Many lung donor offers are refused despite increasing demand. Portable normothermic ex vivo lung perfusion (EVLP) could increase donor yield by monitoring and reconditioning extended criteria donor (ECD) lungs. We report its use in human lungs declined for clinical transplantation. Ten sets of such lungs were procured from brain-dead donors and underwent 24 hours of normothermic EVLP using a perfusate based on donor whole blood. Hemodynamic and ventilatory data and P:F ratios were measured. Advanced donor age and borderline oxygenation (donor mean P:F 228 ± 73) were the most commonly cited reasons for refusal for transplantation. There was no significant worsening of pulmonary hemodynamics or compliance or significant P:F decline during preservation in the overall cohort. Mean P:F ratio in the overall cohort was 315 ± 88 mm Hg after 24 hours EVLP. At EVLP termination 5/10 lung blocks met standard EVLP thresholds for acceptability for transplant. Eventual EVLP performance was poorly predicted by donor P:F ratio but well predicted by data gathered early in EVLP. Portable normothermic EVLP is useful for transportation, monitoring, and reconditioning of ECD lungs. Early EVLP measurements are more effective than preprocurement donor P:F in predicting eventual allograft performance. We advocate an aggressive strategy of evaluation of ECD lungs using blood-based EVLP.


Assuntos
Transplante de Pulmão , Preservação de Órgãos , Humanos , Pulmão , Perfusão , Doadores de Tecidos , Isquemia Quente
2.
BMC Anesthesiol ; 20(1): 270, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-33096987

RESUMO

BACKGROUND: Statin intake is associated with muscular side effects, among which the unmasking of latent myopathies and of malignant hyperthermia (MH) susceptibility have been reported. These findings, together with experimental data in small animals, prompt speculation that statin therapy may compromise the performance of skeletal muscle during diagnostic in vitro contracture tests (IVCT). In addition, statins might reduce triggering thresholds in susceptible individuals (MHS), or exacerbate MH progression. We sought to obtain empirical data to address these questions. METHODS: We compared the responses of 3 different muscles from untreated or simvastatin treated MHS and non-susceptible (MHN) pigs. MHS animals were also invasively monitored for signs of impending MH during sevoflurane anesthesia. RESULTS: Muscles from statin treated MHS pigs responded with enhanced in vitro contractures to halothane, while responses to caffeine were unaltered by the treatment. Neither agent elicited contractures in muscles from statin treated MHN pigs. In vivo, end- tide pCO2, hemodynamic evolution, plasma pH, potassium and lactate concentrations consistently pointed to mild acceleration of MH development in statin-treated pigs, whereas masseter spasm and rigor faded compared to untreated MHS animals. CONCLUSIONS: The diagnostic sensitivity and specificity of the IVCT remains unchanged by a short-term simvastatin treatment in MHS swine. Evidence of modest enhancement in cardiovascular and metabolic signs of MH, as well as masked pathognomonic muscle rigor observed under simvastatin therapy suggest a potentially misleading influence on the clinical presentation of MH. The findings deserve further study to include other statins and therapeutic regimes.


Assuntos
Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Hipertermia Maligna/etiologia , Animais , Contratura/induzido quimicamente , Suscetibilidade a Doenças , Hipertermia Maligna/diagnóstico , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiologia , Sevoflurano/efeitos adversos , Suínos
3.
J Card Surg ; 35(3): 668-671, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31945224

RESUMO

BACKGROUND: Our research team obtained a human heart with the right lung attached from a recent transplantation patient via a research collaboration with LifeSource, a local organ procurement organization. The heart and lungs were not viable for transplant given the patient's medical history and were subsequently offered to the University of Minnesota for research purposes. METHODS: Using Visible Heart® methodologies, we reanimated the specimen en bloc and collected multimodal direct visualization from inside the cardiac chambers and great vessels of the functioning heart. RESULTS: Video footage, using videoscopic and fluoroscopic imaging, was captured and is presented in this report as supporting material. Multiple still images highlight the surgical suture sites of the transplantation procedures. CONCLUSIONS: This multimodal imaging offers unique educational value for medical students, clinicians, and medical device designers for improving transplantation techniques and patient outcomes.


Assuntos
Transplante de Coração , Coração/diagnóstico por imagem , Imagem Multimodal/métodos , Humanos
4.
Magn Reson Med ; 79(1): 511-514, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28342176

RESUMO

PURPOSE: In this work, we investigated the relative effects of static magnetic field exposure (10.5 Tesla [T]) on two physiological parameters; blood pressure (BP) and heart rate (HR). METHODS: In vivo, we recorded both BP and HR in 4 swine (3 female, 1 male) while they were positioned within a 10.5T magnet. All measurements were performed invasively within these anesthetized animals by the placement of pressure catheters into their carotid arteries. RESULTS: We measured average increases of 2.0 mm Hg (standard deviation [SD], 6.9) in systolic BP and an increase of 4.5 mm Hg (SD, 13.7) in the diastolic BPs: We also noted an average increase of 1.2 beats per minute (SD, 2.5) in the HRs during such. CONCLUSION: Data regarding changes in BP and HR in anesthetized swine attributed to whole-body 10.5T exposure are reported. Magn Reson Med 79:511-514, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Anestesia , Pressão Sanguínea , Frequência Cardíaca , Campos Magnéticos , Animais , Determinação da Pressão Arterial , Artérias Carótidas/diagnóstico por imagem , Diástole , Feminino , Imageamento por Ressonância Magnética , Masculino , Suínos , Sístole
5.
J Exp Biol ; 220(Pt 3): 455-459, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27885044

RESUMO

Remarkably, American black bears (Ursus americanus) are capable of varying their heart rates to coincide with their breathing, creating pauses of 30 s or more, yet they do not appear to suffer from embolic events. We evaluated some features of the clotting cascade of black bears, providing novel insights into the underlying mechanisms they evoke for embolic protection during hibernation. We measured activated clotting time, prothrombin time and activated partial thromboplastin time during early denning (December), late denning (March) and summer (August). Activated clotting time during early hibernation was ∼3 times longer than that observed among non-hibernating animals. Clotting time was reduced later in hibernation, when bears were within ∼1 month of emerging from dens. Prothrombin time was similar for each seasonal time point, whereas activated partial thromboplastin time was highest during early denning and decreased during late denning and summer. We also examined D-dimer concentration to assess whether the bears were likely to have experienced embolic events. None of the non-parturient bears exceeded a D-dimer concentration of 250 ng ml-1 (considered the clinical threshold for embolism in mammals). Our findings suggest there is unique expression of the clotting cascade in American black bears during hibernation, in which extrinsic pathways are maintained but intrinsic pathways are suppressed. This was evaluated by a significant difference between the activated clotting time and activated partial thromboplastin time during the denning and non-denning periods. These changes are likely adaptive, to avoid clotting events during states of immobilization and/or periods of asystole. However, an intact extrinsic pathway allows for healing of external injuries and/or foreign body responses.


Assuntos
Coagulação Sanguínea , Hibernação , Ursidae/sangue , Ursidae/fisiologia , Animais , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Masculino , Estações do Ano
6.
Transpl Int ; 30(9): 932-944, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28493634

RESUMO

Donation after circulatory death (DCD) is an underused source of donor lungs. Normothermic cellular ex vivo lung perfusion (EVLP) is effective in preserving standard donor lungs but may also be useful in the preservation and assessment of DCD lungs. Using a model of DCD and prolonged EVLP, the effects of donor warm ischemia and postmortem ventilation on graft recovery were evaluated. Adult male swine underwent general anesthesia and heparinization. In the control group (n = 4), cardioplegic arrest was induced and the lungs were procured immediately. In the four treatment groups, a period of agonal hypoxia was followed by either 1 h of warm ischemia with (n = 4) or without (n = 4) ventilation or 2 h of warm ischemia with (n = 4) or without (n = 4) ventilation. All lungs were studied on an EVLP platform for 24 h. Hemodynamic measures, compliance, and oxygenation on EVLP were worse in all DCD lungs compared with controls. Hemodynamics and compliance normalized in all lungs after 24 h of EVLP, but DCD lungs demonstrated impaired oxygenation. Normothermic cellular EVLP is effective in preserving and monitoring of DCD lungs. Early donor postmortem ventilation and timely procurement lead to improved graft function.


Assuntos
Seleção do Doador/métodos , Lesão Pulmonar/prevenção & controle , Transplante de Pulmão , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Lesão Pulmonar/etiologia , Masculino , Preservação de Órgãos/efeitos adversos , Avaliação de Resultados em Cuidados de Saúde , Distribuição Aleatória , Suínos , Fatores de Tempo , Isquemia Quente
7.
BMC Physiol ; 16(1): 4, 2016 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-27259478

RESUMO

BACKGROUND: In vitro isolated heart preparations are valuable tools for the study of cardiac anatomy and physiology, as well as for preclinical device testing. Such preparations afford investigators a high level of hemodynamic control, independent of host or systemic interactions. Here we hypothesize that recovered human and swine heart-lung blocs can be reanimated using a clear perfusate and elicit viable cardiodynamic and pulmonic function. Further, this approach will facilitate multimodal imaging, which is particularly valuable for the study of both functional anatomy and device-tissue interactions. Five human and 18 swine heart-lung preparations were procured using techniques analogous to those for cardiac transplant. Specimens were then rewarmed and reperfused using modifications of a closed circuit, isolated, beating and ventilated heart-lung preparation. Positive pressure mechanical ventilation was also employed, and epicardial defibrillation was applied to elicit native cardiac sinus rhythm. Videoscopy, fluoroscopy, ultrasound, and infrared imaging were performed for anatomical and experimental study. RESULTS: Systolic and diastolic left ventricular pressures observed for human and swine specimens were 68/2 ± 11/7 and 74/3 ± 17/5 mmHg, respectively, with associated native heart rates of 80 ± 7 and 96 ± 16 beats per minute. High-resolution imaging within functioning human pulmonary vasculature was obtained among other anatomies of interest. Note that one human specimen elicited poor cardiac performance post defibrillation. CONCLUSIONS: We report the first dynamic videoscopic images of the pulmonary vasculature during viable cardiopulmonary function in isolated reanimated heart-lung blocs. This experimental approach provides unique in vitro opportunities for the study of novel medical therapeutics applied to large mammalian, including human, heart-lung specimens.


Assuntos
Coração/fisiologia , Pulmão/fisiologia , Adulto , Idoso , Animais , Feminino , Frequência Cardíaca , Hemodinâmica , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Técnicas de Cultura de Órgãos/métodos , Suínos
8.
PLoS One ; 18(2): e0263639, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36780442

RESUMO

The aim of this work was to analyze the influence of sex hormones and anatomical details (trabeculations and false tendons) on the electrophysiology of healthy human hearts. Additionally, sex- and anatomy-dependent effects of ventricular tachycardia (VT) inducibility are presented. To this end, four anatomically normal, human, biventricular geometries (two male, two female), with identifiable trabeculations, were obtained from high-resolution, ex-vivo MRI and represented by detailed and smoothed geometrical models (with and without the trabeculations). Additionally one model was augmented by a scar. The electrophysiology finite element model (FEM) simulations were carried out, using O'Hara-Rudy human myocyte model with sex phenotypes of Yang and Clancy. A systematic comparison between detailed vs smooth anatomies, male vs female normal hearts was carried out. The heart with a myocardial infarction was subjected to a programmed stimulus protocol to identify the effects of sex and anatomical detail on ventricular tachycardia inducibility. All female hearts presented QT-interval prolongation however the prolongation interval in comparison to the male phenotypes was anatomy-dependent and was not correlated to the size of the heart. Detailed geometries showed QRS fractionation and increased T-wave magnitude in comparison to the corresponding smoothed geometries. A variety of sustained VTs were obtained in the detailed and smoothed male geometries at different pacing locations, which provide evidence of the geometry-dependent differences regarding the prediction of the locations of reentry channels. In the female phenotype, sustained VTs were induced in both detailed and smooth geometries with RV apex pacing, however no consistent reentry channels were identified. Anatomical and physiological cardiac features play an important role defining risk in cardiac disease. These are often excluded from cardiac electrophysiology simulations. The assumption that the cardiac endocardium is smooth may produce inaccurate predictions towards the location of reentry channels in in-silico tachycardia inducibility studies.


Assuntos
Caracteres Sexuais , Taquicardia Ventricular , Feminino , Masculino , Humanos , Ventrículos do Coração , Coração , Arritmias Cardíacas , Simulação por Computador , Estimulação Cardíaca Artificial , Eletrocardiografia
9.
Cardiovasc Interv Ther ; 37(3): 519-525, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34468961

RESUMO

Transcatheter therapies are a common way to treat cardiovascular diseases. These therapies are complicated by significant anatomical patient-to-patient variations that exist in terms of transcatheter vascular pathways. Adding to the complexity of transcatheter procedures, the training tools used for physician education often overlook vast patient-to-patient variations and utilize idealized models of patient anatomy that may be unrealistic. In this study, anatomically accurate models were created from high-resolution images of real patient vasculatures. Using fourteen human cadavers donated for research, we collected high-resolution images to generate 3D computational renderings of various patient anatomies. These models make up the "Transcatheter Pathways Vasculature Database" that can be used for physician education and training, as well as improving transcatheter delivery system design. We performed multiple studies that emphasize the anatomical differences that exist in patient vasculatures. Using 3D printing and virtual reality, we developed educational materials and benchtop models to train physicians using true patient anatomies. These tools can also provide device designers with data to improve their products based on real patient vessels. The "Transcatheter Pathways Vasculature Database" highlights differences between patient vasculatures. By educating and training physicians with patient anatomies that accurately represent significant patient-to-patient variations, learning is more translatable to what is seen in the clinic.


Assuntos
Imageamento Tridimensional , Modelos Anatômicos , Humanos , Imageamento Tridimensional/métodos , Impressão Tridimensional
10.
EuroIntervention ; 18(6): 457-470, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-35570753

RESUMO

The European Bifurcation Club (EBC) supports a continuous review of the field of coronary artery bifurcation interventions and aims to facilitate a scientific discussion and an exchange of ideas on the management of bifurcation disease. The recent focus of meetings and consensus statements has been on the technical issues in bifurcation stenting, recognising that the final result of a bifurcation procedure and the long-term outcome for our patients are strongly influenced by factors, including preprocedural strategy, stenting technique selection, performance of optimal procedural steps, the ability to identify and correct complications and finally, and most important, the overall performance of the operator. Continuous refinement of bifurcation stenting techniques and the promotion of education and training in bifurcation stenting techniques represent a major clinical need. Accordingly, the consensus from the latest EBC meeting in Brussels, October 2021, was to promote education and training in bifurcation stenting based on the EBC principle. Part II of this 16th EBC consensus document aims to provide a step-by-step overview of the pitfalls and technical troubleshooting during the implantation of the second stent either in the provisional stenting (PS) strategy or in upfront 2-stent techniques (e.g., 2-stent PS pathway and double kissing crush stenting). Finally, a detailed overview and discussion of the numerous modalities available to provide continuous education and technical training in bifurcation stenting techniques are discussed, with consideration of their future application in enhancing training and practice in coronary bifurcation lesion treatment.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/métodos , Stents , Resultado do Tratamento
11.
Philos Trans R Soc Lond B Biol Sci ; 376(1830): 20200217, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34121460

RESUMO

The latest technologies associated with implantable physiological monitoring devices can record multiple channels of data (including: heart rates and rhythms, activity, temperature, impedance and posture), and coupled with powerful software applications, have provided novel insights into the physiology of animals in the wild. This perspective details past challenges and lessons learned from the uses and developments of implanted biologgers designed for human clinical application in our research on free-ranging American black bears (Ursus americanus). In addition, we reference other research by colleagues and collaborators who have leveraged these devices in their work, including: brown bears (Ursus arctos), grey wolves (Canis lupus), moose (Alces alces), maned wolves (Chrysocyon brachyurus) and southern elephant seals (Mirounga leonina). We also discuss the potentials for applications of such devices across a range of other species. To date, the devices described have been used in fifteen different wild species, with publications pending in many instances. We have focused our physiological research on the analyses of heart rates and rhythms and thus special attention will be paid to this topic. We then discuss some major expected step changes such as improvements in sensing algorithms, data storage, and the incorporation of next-generation short-range wireless telemetry. The latter provides new avenues for data transfer, and when combined with cloud-based computing, it not only provides means for big data storage but also the ability to readily leverage high-performance computing platforms using artificial intelligence and machine learning algorithms. These advances will dramatically increase both data quantity and quality and will facilitate the development of automated recognition of extreme physiological events or key behaviours of interest in a broad array of environments, thus further aiding wildlife monitoring and management. This article is part of the theme issue 'Measuring physiology in free-living animals (Part I)'.


Assuntos
Caniformia/fisiologia , Engenharia/instrumentação , Testes de Função Cardíaca/veterinária , Fisiologia/instrumentação , Animais , Testes de Função Cardíaca/instrumentação , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/veterinária
12.
Int J Cardiovasc Imaging ; 37(9): 2591-2601, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33993420

RESUMO

Stent implantation in bifurcated coronary lesions is technically challenging so that procedural refinements are continuously investigated. Novel procedure modeling and intracoronary imaging techniques may offer critical insights on stent deformations and stent-wall interactions during bifurcation stenting procedures. Thus, we assessed coronary bifurcation stenting techniques using multimodal imaging and 3D modeling in reanimated swine hearts. Harvested swine hearts were reanimated using Visible Heart® methodologies and (under standard fluoroscopic guidance) used to test 1-stent (provisional and inverted provisional) and 2-stent (culotte, TAP and DK-crush) techniques on bifurcations within various coronary vessels using commercially available devices. Intracoronary angioscopy and frequency-domain optical-coherence-tomography (OCT) were obtained during the procedures. 3D OCT reconstruction and micro-computed tomography 3D modeling (post heart fixations) were used to assess stent deformations and stent-wall interactions. We conducted multiple stenting procedures and collected unique endoscopic and OCT images (and subsequent computational models from micro-CT) to assess stent deformations and device/wall interactions during different steps of bifurcation stenting procedures. Endoscopy, micro-CT and virtual reality processing documented that different 1- and 2-stent techniques, practiced according to experts' recommended steps, achieve optimal post-intervention stent conformation. As compared with intra-procedural endoscopy, software-generated 3D OCT images accurately depicted stent deformations during 1-stent techniques. On the opposite, during more complex 2-stent techniques, some defects were appreciated at 3D OCT reconstruction despite optimal 2D OCT images. This study provided unique insights regarding both stent deformations occurring in the course of bifurcation stenting and the efficacy of OCT to visualize them.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Animais , Angiografia Coronária , Imagem Multimodal , Valor Preditivo dos Testes , Stents , Suínos , Resultado do Tratamento , Microtomografia por Raio-X
13.
Heart Rhythm ; 17(6): 1009-1016, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31931170

RESUMO

BACKGROUND: The number of lead extractions is growing because of the greater population and increasing age of individuals with a cardiac implantable electronic device. Lead extraction procedures can be complex undertakings with risk of significant mortality, and vascular tears in the superior vena cava are of greatest concern. OBJECTIVE: The purpose of this study was to study whether a novel algorithm that analyzes pre-extraction computed tomographic (CT) images can determine the likelihood and location of lead-lead interactions and lead-vessel attachment within patients' venous vasculatures. This information can be used to identify potential case challenges in the planning stages. METHODS: We developed an algorithm to estimate the presence and position of lead-lead interactions and lead-vessel adherences by tracking distance between the leads and distance between the lead and superior vena cava in a sample of 12 patients referred to the United Heart and Vascular Clinic for lead extractions due to infection (n = 5), lead failure (n = 5), and tricuspid regurgitation (n = 2). RESULTS: Preliminary results indicate that the developed algorithm successfully identified lead-lead and lead-vascular attachments compared to review of CT images by medical experts. CONCLUSION: With future validation and clinical implementation, this algorithm could aid physician preparedness by minimizing intraprocedural emergencies and may improve patient outcomes.


Assuntos
Algoritmos , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Tomografia Computadorizada por Raios X/métodos , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Estudos Retrospectivos , Veia Cava Superior
14.
Ann Thorac Surg ; 110(1): 336-341, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31958424

RESUMO

A pioneering surgeon at the University of Minnesota, Dr C. Walton Lillehei, is still considered the "father of open-heart surgery". Dr Lillehei and his surgical team performed the first open-heart operations utilizing cross-circulation, including the first successful ventricular septal defect closure on a 3-year-old boy. Before his death at age 67, this patient arranged to donate his body to the University of Minnesota's Anatomy Bequest program. We describe this patient's medical history, and present unique images of internal/external cardiac anatomies and implanted devices obtained via direct visualizations, computed tomography, and fluoroscopy post-mortem. Additionally, we present computational models and 3-dimensional printed models.


Assuntos
Procedimentos Cirúrgicos Cardíacos/história , Circulação Cruzada/história , Comunicação Interventricular/história , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , História do Século XX , Humanos
15.
Surgery ; 167(2): 259-263, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-30792012

RESUMO

BACKGROUND: Three-dimensional printing is an additive manufacturing method that builds objects from digitally generated computational models. Core technologies behind three-dimensional printing are evolving rapidly with major advances in materials, resolution, and speed that enable greater realism and higher accuracy. These improvements have led to novel applications of these processes in the medical field. METHODS: The process of going from a medical image data set (computed tomography, magnetic resonance imaging, ultrasound) to a physical three-dimensional print includes several steps that are described. Medical images originate from Digital Imaging and Communications in Medicine files or data sets, the current standard for storing and transmitting medical images. Via Digital Imaging and Communications in Medicine manipulation software packages, a segmentation process, and manual intervention by an expert user, three-dimensional digital and printed models can be constructed in great detail. RESULTS: Cardiovascular medicine is one of the fastest growing applications for medical three-dimensional printing. The technology is more frequently being used for patient and clinician education, preprocedural planning, and medical device design and prototyping. We report on three case studies, describing how our three-dimensional printing has contributed to the care of cardiac patients at the University of Minnesota. CONCLUSION: Medical applications of computational three-dimensional modeling and printing are already extensive and growing rapidly and are routinely used for visualizing complex anatomies from patient imaging files to plan surgeries and create surgical simulators. Studies are needed to determine whether three-dimensional printed models are cost effective and can consistently improve clinical outcomes before they become part of routine clinical practice.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração/diagnóstico por imagem , Medicina de Precisão , Impressão Tridimensional , Dextrocardia , Humanos , Gêmeos Unidos
16.
J Cardiovasc Transl Res ; 12(3): 250-256, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30430355

RESUMO

Radiofrequency, a common ablation modality, is used clinically to terminate cardiac arrhythmias. With excessive heating, complications sometimes occur when the applied energy generates steam pops, which cause release of energy in the form of tissue and/or air emboli. In this study, we investigated numerous parameters potentially associated with intracardiac steam pops including (1) wattage, (2) catheter tip temperature, (3) catheter irrigation, (4) anatomic site, and (5) repeat ablations at a given site. Using unique Visible Heart® methodologies in reanimated swine hearts, we visualized 539 ablations; steam pops developed in 140 of these ablations. The incidence of steam pops significantly increased for both nonirrigated and irrigated ablations at 40 W (p < 0.005), and for nonirrigated ablations with catheter contact angles perpendicular to the tissue or that encompassed larger surface areas (p < 0.05). To minimize the incidence of steam pops, clinicians performing radiofrequency ablations must consider catheter parameters.


Assuntos
Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Endoscopia , Átrios do Coração/cirurgia , Radiografia Intervencionista , Vapor/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Percepção Visual , Animais , Ablação por Cateter/instrumentação , Endoscópios , Endoscopia/instrumentação , Desenho de Equipamento , Fluoroscopia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Miocárdio/patologia , Ruído , Reoperação , Sus scrofa , Irrigação Terapêutica/instrumentação , Fatores de Tempo , Gravação em Vídeo
17.
Front Physiol ; 9: 458, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29760665

RESUMO

The aim of the present study is to characterize the hemodynamics of left ventricular (LV) geometries to examine the impact of trabeculae and papillary muscles (PMs) on blood flow using high performance computing (HPC). Five pairs of detailed and smoothed LV endocardium models were reconstructed from high-resolution magnetic resonance images (MRI) of ex-vivo human hearts. The detailed model of one LV pair is characterized only by the PMs and few big trabeculae, to represent state of art level of endocardial detail. The other four detailed models obtained include instead endocardial structures measuring ≥1 mm2 in cross-sectional area. The geometrical characterizations were done using computational fluid dynamics (CFD) simulations with rigid walls and both constant and transient flow inputs on the detailed and smoothed models for comparison. These simulations do not represent a clinical or physiological scenario, but a characterization of the interaction of endocardial structures with blood flow. Steady flow simulations were employed to quantify the pressure drop between the inlet and the outlet of the LVs and the wall shear stress (WSS). Coherent structures were analyzed using the Q-criterion for both constant and transient flow inputs. Our results show that trabeculae and PMs increase the intra-ventricular pressure drop, reduce the WSS and disrupt the dominant single vortex, usually present in the smoothed-endocardium models, generating secondary small vortices. Given that obtaining high resolution anatomical detail is challenging in-vivo, we propose that the effect of trabeculations can be incorporated into smoothed ventricular geometries by adding a porous layer along the LV endocardial wall. Results show that a porous layer of a thickness of 1.2·10-2 m with a porosity of 20 kg/m2 on the smoothed-endocardium ventricle models approximates the pressure drops, vorticities and WSS observed in the detailed models.

18.
Int J Numer Method Biomed Eng ; 34(9): e3115, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29892995

RESUMO

Computational modelling plays an important role in right ventricular (RV) haemodynamic analysis. However, current approaches use smoothed ventricular anatomies. The aim of this study is to characterise RV haemodynamics including detailed endocardial structures like trabeculae, moderator band, and papillary muscles. Four paired detailed and smoothed RV endocardium models (2 male and 2 female) were reconstructed from ex vivo human hearts high-resolution magnetic resonance images. Detailed models include structures with ≥1 mm2 cross-sectional area. Haemodynamic characterisation was done by computational fluid dynamics simulations with steady and transient inflows, using high-performance computing. The differences between the flows in smoothed and detailed models were assessed using Q-criterion for vorticity quantification, the pressure drop between inlet and outlet, and the wall shear stress. Results demonstrated that detailed endocardial structures increase the degree of intra-ventricular pressure drop, decrease the wall shear stress, and disrupt the dominant vortex creating secondary small vortices. Increasingly turbulent blood flow was observed in the detailed RVs. Female RVs were less trabeculated and presented lower pressure drops than the males. In conclusion, neglecting endocardial structures in RV haemodynamic models may lead to inaccurate conclusions about the pressures, stresses, and blood flow behaviour in the cavity.


Assuntos
Coração/fisiologia , Hemodinâmica , Função Ventricular/fisiologia , Simulação por Computador , Feminino , Coração/diagnóstico por imagem , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Modelos Cardiovasculares , Resistência ao Cisalhamento
19.
Transplantation ; 101(10): 2303-2311, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28009782

RESUMO

BACKGROUND: We report the ability to extend lung preservation up to 24 hours (24H) by using autologous whole donor blood circulating within an ex vivo lung perfusion (EVLP) system. This approach facilitates donor lung reconditioning in a model of extended normothermic EVLP. We analyzed comparative responses to cellular and acellular perfusates to identify these benefits. METHODS: Twelve pairs of swine lungs were retrieved after cardiac arrest and studied for 24H on the Organ Care System (OCS) Lung EVLP platform. Three groups (n = 4 each) were differentiated by perfusate: (1) isolated red blood cells (RBCs) (current clinical standard for OCS); (2) whole blood (WB); and (3) acellular buffered dextran-albumin solution (analogous to STEEN solution). RESULTS: Only the RBC and WB groups met clinical standards for transplantation at 8 hours; our primary analysis at 24H focused on perfusion with WB versus RBC. The WB perfusate was superior (vs RBC) for maintaining stability of all monitored parameters, including the following mean 24H measures: pulmonary artery pressure (6.8 vs 9.0 mm Hg), reservoir volume replacement (85 vs 1607 mL), and PaO2:FiO2 ratio (541 vs 223). Acellular perfusion was limited to 6 hours on the OCS system due to prohibitively high vascular resistance, edema, and worsening compliance. CONCLUSIONS: The use of an autologous whole donor blood perfusate allowed 24H of preservation without functional deterioration and was superior to both RBC and buffered dextran-albumin solution for extended lung preservation in a swine model using OCS Lung. This finding represents a potentially significant advance in donor lung preservation and reconditioning.


Assuntos
Eritrócitos , Circulação Extracorpórea/métodos , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Pulmão/efeitos dos fármacos , Soluções para Preservação de Órgãos/farmacologia , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Eritrócitos/metabolismo , Parada Cardíaca , Hemodinâmica , Pulmão/patologia , Pulmão/cirurgia , Lesão Pulmonar/etiologia , Transplante de Pulmão/efeitos adversos , Masculino , Modelos Animais , Preservação de Órgãos/efeitos adversos , Oxigênio/sangue , Perfusão/efeitos adversos , Pneumonia/etiologia , Circulação Pulmonar , Edema Pulmonar/etiologia , Traumatismo por Reperfusão/etiologia , Sus scrofa , Fatores de Tempo , Sobrevivência de Tecidos/efeitos dos fármacos
20.
J Vis Exp ; (113)2016 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-27500319

RESUMO

To date, many pharmacological agents used to treat or prevent arrhythmias in open-heart cases create undesired systemic side effects. For example, antiarrhythmic drugs administered intravenously can produce drops in systemic pressure in the already compromised cardiac patient. While performing open-heart procedures, surgeons will often either create a small port or form a pericardial cradle to create suitable fields for operation. This access yields opportunities for target pharmacological delivery (antiarrhythmic or ischemic preconditioning agents) directly to the myocardial tissue without undesired side effects. We have developed a swine model for testing pharmacological agents for target delivery within the pericardial fluid. While fully anesthetized, each animal was instrumented with a Swan-Ganz catheter as well as left and right ventricle pressure catheters, and pacing leads were placed in the right atrial appendage and the right ventricle. A medial sternotomy was then performed and a pericardial access cradle was created; a plunge pacing lead was placed in the left atrial appendage and a bipolar pacing lead was placed in the left ventricle. Utilizing a programmer and a cardiac mapping system, the refractory period of the atrioventricular node (AVN), atria and ventricles was determined. In addition, atrial fibrillation (AF) induction was produced utilizing a Grass stimulator and time in AF was observed. These measurements were performed prior to treatment, as well as 30 min and 60 min after pericardial treatment. Additional time points were added for selected studies. The heart was then cardiopleged and reanimated in a four chamber working mode. Pressure measurements and function were recorded for 1 hr after reanimation. This treatment strategy model allowed us to observe the effects of pharmacological agents that may decrease the incidence of cardiac arrhythmias and/or ischemic damage, during and after open-heart surgery.


Assuntos
Sistemas de Liberação de Medicamentos , Animais , Apêndice Atrial , Fibrilação Atrial/tratamento farmacológico , Átrios do Coração , Ventrículos do Coração , Pericárdio , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA