Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Science ; 219(4586): 845-7, 1983 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-6823553

RESUMO

A modified flow cytometer has been used to detect attogram quantities of aqueous rhodamine 6G by laser-induced fluorescence analysis. A detection limit of 28 attograms (35,000 molecules) was obtained, nearly two orders of magnitude better than earlier measurements. The detection limit in concentration units was 1.4 x 10(-13) mole per liter. During the 1-second measurement period, the total volume sampled was 0.42 microliter. On average, only half a rhodamine 6G molecule was present in the 6-picoliter probed volume.


Assuntos
Citometria de Fluxo/métodos , Rodaminas/análise , Xantenos/análise , Lasers
2.
J Histochem Cytochem ; 27(1): 264-7, 1979 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-374583

RESUMO

Both forward angle and 90 degrees light-scattering measurements have been used for cell sizing with stream-in-air flow systems with very little theoretical base for the measurements. Mie theory calculations are compared with measurements on plastic microspheres. Detector response for homogeneous spheres is shown to be sensitive to refractive index.


Assuntos
Contagem de Células , Técnicas Citológicas , Espalhamento de Radiação , Técnicas Citológicas/instrumentação , Látex , Luz , Microesferas , Modelos Biológicos
3.
J Histochem Cytochem ; 27(1): 315-20, 1979 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-374594

RESUMO

In laser flow cytometry, an increasingly popular technique of analytical cytology, quantitative measurements of interest include cell and nuclear diameters. Electronic circuitry for a new cell sizing technique has been developed which measured the time that signal pulses from either fluorescence or light scatter sensors exceed a preset constant fraction of the peak signal amplitude (pulse width) or the time that it takes a signal to rise between constant fractions of the peak signal amplitude on the rising side of the pulse (pulse rise-time). These pulse width or pulse rise-time measurements were related to cell or nuclear diameters and were used in combination to determine nuclear size to cell size ratios. This method of sizing was found to be independent of fluorescent or light-absorbing stain intensity, linearly related to cell or nuclear diameter, and capable of resolving small diameter differences.


Assuntos
Núcleo Celular , Células Cultivadas/citologia , Técnicas Citológicas , Fotometria , Animais , Contagem de Células , Linhagem Celular , Cricetinae , Fluorescência , Humanos , Neoplasias Laríngeas , Lasers , Luz , Pulmão/embriologia , Espalhamento de Radiação
4.
J Histochem Cytochem ; 24(1): 383-7, 1976 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-768372

RESUMO

A method for quantitating the specific stimulation of peripheral lymphocytes has been developed using the techniques of flow microfluorometry. Peripheral bovine lymphocytes were collected and specifically stained for deoxyribonucleic acid (DNA) content using a low-salt propidium iodide procedure. Flow microfluorometry was used to determine, on the basis of DNA content, the percentage of cells in a population that was stimulated. Extremely uniform staining of the lymphocytes (coefficient of variation of less than 2%) provides a high resolution between proliferating and nonproliferating cells. The method provides a rapid, highly repoducible technique for determing the fraction of lymphocytes stimulated in response to tuberculin antigens based on an increase in cellular DNA content. Specific and nonspecific stimulation by a defined antigen can be measured and resolved.


Assuntos
Linfócitos/citologia , Animais , Autoanálise , Bovinos , DNA/biossíntese , Linfócitos/metabolismo , Microscopia de Fluorescência/métodos , Mycobacterium , Mycobacterium bovis , Especificidade da Espécie , Timidina/metabolismo
6.
J Biomol Struct Dyn ; 7(2): 301-9, 1989 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2557861

RESUMO

We are developing a laser based technique for the rapid sequencing of large fragments (approximately 40 kb) of DNA based upon the detection of single, fluorescently tagged nucleotides cleaved from a single DNA fragment. We have demonstrated significant progress on several of the important steps of this technique. The projected rate of sequencing is several hundred bases per second which is orders of magnitude faster than existing methods. Once developed, this technology could be utilized by investigators for rapid sequencing of genetic material from virtually any source.


Assuntos
Sequência de Bases , DNA , DNA/isolamento & purificação , Exonucleases , Corantes Fluorescentes , Fluorometria/métodos , Lasers , Métodos
7.
J Biol Regul Homeost Agents ; 18(3-4): 352-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15786704

RESUMO

The first flow cytometric analyses were of total cellular DNA or protein content. The advent of labeled antibodies, first polyclonal and then monoclonal, led to the analysis of cellular content of specific antigen molecules and a myriad of immunological applications. Although, strictly speaking, it is incorrect to use the word "cytometry" for anything that does not refer to cellular measurements, the term has been used for a variety of non-cellular measurements such as chromosome analysis and solution molecular measurements. In recent years, there has been an increase in the development of methods to analyze molecules and their properties in solution. These analyses have ranged from ensemble measurements, primarily fluorescence-based immunoassays, to single molecule detection with applications in DNA analysis.


Assuntos
DNA/análise , Citometria de Fluxo/métodos , Endonucleases Flap/metabolismo , Transferência Ressonante de Energia de Fluorescência , Humanos
8.
Hum Cell ; 10(1): 3-10, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9234060

RESUMO

The envelope that defines the limits within which flow cytometry was developed is being rapidly expanded. For example: detection sensitivity has been extended to single molecules, the size range of "particle" analysis now extends from DNA fragments to plankton (1,000.+ microns), cell and chromosome sorting rates are being increased dramatically by using inactivation procedures (50,000 per second versus 2,000 per second), rapid kinetic flow cytometry enables real-time analysis of molecular assembly and cell function in the sub-second time domain, the lifetime of a fluorochrome bound to a single cell can be measured with nsec precision, and classical karyotype information (cell to cell heterogeneity) can be determined in a flow based system. These frontiers have greatly expanded the range of new and exciting flow cytometric based biomedical applications. New enabling technologies have provided the means to measure DNA cleavage by the structure-specific nuclease, human Flap Endonuclease (FEN-1), in the 300 msec time frame. Phase sensitive measurements and fluorescence lifetime are proving to be major advances for understanding molecular environments that change with, for example, the process of apoptosis. The ability to detect single fluorescent molecules has been applied to the analysis of DNA fragments obtained from enzymatic digestion of lambda DNA. This technology is being used to rapidly and very accurately size DNA fragments for the human genome project. Optical chromosome selection is a faster, better, less complex approach to chromosome sorting. This method is based on the induction of specific damage to the DNA of selected chromosomes. Lastly, the miniaturization of a single cell fractionator has made it possible to perform single cell flow cytogenetics.


Assuntos
Citometria de Fluxo/tendências , Cromossomos Humanos , DNA/análise , Fragmentação do DNA , Citometria de Fluxo/métodos , Corantes Fluorescentes , Previsões , Humanos , Cariotipagem
14.
Cytometry ; 6(5): 484-6, 1985 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-4042789

RESUMO

The systematics of droplet formation conditions for orifices with diameters up to 200 micron are described. Sorting recovery experiments indicate that particles up to 44 micron in diameter can be recovered by charged droplet deflection of two drops with at least 75% recovery. By reducing the jet velocity, a deflection of greater than 1 cm was obtained for all droplet sizes.


Assuntos
Separação Celular/instrumentação , Citometria de Fluxo/instrumentação , Espectrometria de Fluorescência
15.
Cell Tissue Kinet ; 14(3): 269-83, 1981 May.
Artigo em Inglês | MEDLINE | ID: mdl-7016329

RESUMO

Spontaneously transformed (tumorigenic) Chinese hamster cells (line CHO) do not exhibit picolinic acid-sensitive G1 and G2 cell cycle arrest points observed in normal and virus-transformed cells. Rather, picolinic acid arrests CHO cells in S phase only and produces culture growth behaviour similar to that produced by hydroxyurea. Prolonged treatment with picolinic acid permits a slow but significant traverse of cells through S phase. Thus, like hydroxyurea, picolinic acid is not a useful agent for synchronizing exponential CHO cells, but it can be used to resynchronize cultures in early S phase if a previous synchronization procedure (such as isoleucine deprivation) is used. The iron chelating properties of picolinic acid, and the similarities of its effects on cultured cells to those of hydroxyurea and the iron-chelating drug desferrioxamine, suggest that picolinic acid inhibits DNA synthesis by interfering with the iron-dependent production of a stable free organic radical which is essential for the ribonucleotide reductase formation of deoxyribonucleotides.


Assuntos
Transformação Celular Neoplásica , Interfase/efeitos dos fármacos , Ácidos Picolínicos/farmacologia , Animais , Autorradiografia , Linhagem Celular , Cricetinae , Técnicas Citológicas , DNA/biossíntese , Feminino , Hidroxiureia/farmacologia , Cinética , Ovário
16.
Cell Tissue Kinet ; 14(4): 413-23, 1981 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7020948

RESUMO

An improved method for determining the fraction of cells in the G1, S and G2 + M phases of the life cycle, from DNA distributions of S phase rich cultures, is presented. Picolinic acid synchronized cell cultures were used to demonstrate the usefulness of the technique for the cell cycle distribution analysis. The algorithm presented quantifies DNA histograms from FCM analyses using an extension of the previously reported 'sum of discrete normal curves' technique. It alleviates problems encountered with earlier methods by extending the contribution of the S phase cells to the distribution under the G1 and G2 + M peaks; at the same time it allows more of the descriptive parameters to be determined from the individual histograms. The fractions of cells in the G1, S, and G2 + M phases of the life cycle obtained by this method compare favourably with autoradiographic analyses and other analytical results.


Assuntos
Técnicas Citológicas , DNA/metabolismo , Interfase , Mitose , Animais , Linhagem Celular , Computadores , Cricetinae , Feminino , Matemática , Ovário
17.
Clin Chem ; 31(12): 2020-3, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3905066

RESUMO

An equilibrium-type competitive-binding fluorescence immunoassay with high sensitivity and excellent precision is described that obviates separation of free from bound label. In the assay relatively large (10 microns diameter) antibody-coated non-fluorescent particles and very small (0.10 micron diameter) antigen-coated fluorescent latex particles are used. Soluble nonlabeled antigen competes with antigen on the microspheres for antibody binding sites on the larger spheres. After equilibrium is attained, the fluorescence distribution of 5000 of the large spheres is measured in a flow cytometer. The mean values for the fluorescence distribution obtained from samples containing known concentrations of soluble antigen are used to construct a standard displacement curve. In a prototype assay for the antigen horseradish peroxidase, a sensitivity of 10(-12) mol/L has been achieved. Undiluted serum can be assayed without loss of sensitivity. Preliminary experiments also indicate that double-antibody "sandwich"-type assays of very high sensitivity (10(-14) mol/L) are also possible when this dual-sphere concept is exploited.


Assuntos
Citometria de Fluxo , Imunofluorescência , Ligação Competitiva , Peroxidase do Rábano Silvestre , Humanos , Luz , Microscopia Eletrônica de Varredura , Microesferas , Espalhamento de Radiação
18.
Chromosoma ; 95(3): 189-96, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-3608718

RESUMO

The evolutionary relationships of Chinese hamster X chromosome and autosome DNA sequences were compared by solution hybridization techniques. Chinese hamster X chromosome tracer was prepared by radiolabeling DNA from chromosomes isolated by fluorescence-activated sorting. Radiolabeled Chinese hamster total genomic DNA, approximately 90% of which is of autosome origin, was used as autosome tracer. Each tracer was mixed with excess driver DNA of Chinese hamster, Syrian hamster, rat, rabbit, cat, cow, or human origin. Reaction mixtures were melted and allowed to reassociate to an equivalent CoT of 12,000, under conditions which permitted 35% mismatch in DNA duplexes. Both the extent of duplex formation (the normalized percentage hybridization or NPH) and the average thermal stability of the duplexes formed (melting temperature or Tm) were measured; these values were used to compare the evolutionary relatedness of tracer and driver DNAs. The pattern of evolutionary relatedness revealed by comparing either the Tm or NPH values obtained with different drivers was the same for X chromosome and autosome DNA and was consistent with the phylogeny of the species examined. Although NPH and Tm values for X chromosome and autosome tracers differed, differences fell within the range of experimental error. The results of these studies provide no evidence for differential conservation of Chinese hamster X chromosome sequences, suggesting that the constraints on the mammalian X chromosome which act to maintain its gene linkage group intact do not markedly reduce the extent to which its sequences diverge during evolution.


Assuntos
Evolução Biológica , Cromossomos , Cricetinae/genética , Cricetulus/genética , Cromossomo X , Animais , Linhagem Celular , DNA/genética , DNA/isolamento & purificação , Feminino , Humanos , Mesocricetus/genética , Hibridização de Ácido Nucleico , Coelhos/genética , Ratos/genética , Especificidade da Espécie
19.
Curr Protoc Cytom ; Chapter 1: Unit 1.10, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-18770661

RESUMO

This unit provides essential knowledge for correctly using any flow cytometer to ensure that data collected are accurate and reliable. Two levels of system alignment are described: routine alignment checks and complete alignment, both of which can be applied to a variety of instrument configurations.


Assuntos
Separação Celular/métodos , Citometria de Fluxo/métodos , Calibragem , Processamento Eletrônico de Dados , Desenho de Equipamento , Fluorescência , Lasers , Reprodutibilidade dos Testes
20.
Cytometry ; 8(4): 427-36, 1987 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3304881

RESUMO

A flow cytometric method has been developed for sorting viable, intact multicellular spheroids in order to obtain uniformly-sized populations with diameters in the range of 50-100 microns. A FACS II instrument was modified for this purpose by installing a 200-microns-diameter exit orifice and by making adjustments in the sheath flow, oscillator frequency, and number of droplets sorted. Polystyrene microspheres (44 and 88 microns diameter) and 41-96-microns-diameter spheroids could be sorted and recovered with 70-100% efficiency, an improvement over previous reports. Unstained, viable spheroids were simultaneously analyzed for small-angle forward light scatter, 90 degree light scatter, and autofluorescence using a 488-nm laser operating at 100 mW. Analysis of the data demonstrated a considerable variation in both the 90 degrees light scatter and the autofluorescence signals for a given forward angle light scattering signal. By setting narrow sort windows on the forward angle light scattering signal and either the 90 degree light scatter or autofluorescence signals, uniformly spherical spheroid populations could be recovered. These sorted populations had coefficients of variation of the mean diameter in the range of 5-9%. This represents a variation of less than one cell diameter, and is a major improvement over any other technique. There was no significant difference in the subsequent growth rates of sorted spheroids compared to the unsorted spheroids. This technique will apply when uniform populations of small spheroids are required, such as investigations of the contact effect or in the initiation of growth curve studies.


Assuntos
Agregação Celular , Citometria de Fluxo/métodos , Animais , Linhagem Celular , Separação Celular/métodos , Microscopia de Contraste de Fase , Microesferas , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA