Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 200
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 131(6): 658-666, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38110124

RESUMO

PURPOSE: The newly released Swedish Interactive Thresholding Algorithm (SITA)-Faster (SFR) has significantly shorter testing durations compared with older SITA algorithms, but its variability is uncertain. This study quantified and established threshold limits of test-retest variability across the 24-2 test grid using SFR. DESIGN: Cross-sectional study with prospective longitudinal arm. PARTICIPANTS: 1426 eyes of 787 patients with healthy, suspected glaucoma, or manifest glaucoma eyes from hospital- and university- eye clinics. METHODS: Two SFR tests per eye at a baseline visit and at two follow-up visits. MAIN OUTCOME MEASURES: Pointwise variability measured by test-retest difference in pointwise sensitivity between tests one and two, mean global variability (test-retest variance) measured by average of pointwise variability for each participant, global sensitivity, and reliability indices of each eye. RESULTS: Of the 1426 eyes, 540 eyes (37.9%) had a diagnosis of glaucoma, 753 eyes (52.8%) were suspected of having glaucoma, and the remaining 133 eyes (9.3%) were healthy. Of 74 152 pointwise sensitivities obtained, the mean test-retest difference was 2.17 ± 2.9 dB, whereas the mean test-retest variance for each participant was 2.17 ± 1.2 dB. Pointwise and global variability increased with worsening threshold sensitivity and (MD), respectively, and was greater for peripheral compared with central test locations. In the longitudinal cohort, no significant difference in mean test-retest variance was found across the 3 visits (mean variability, 2.10 dB vs. 2.16 dB vs. 2.16 dB at visits F0 vs. F1 vs. F2; P = 0.53, repeated-measures analysis of variance). Baseline MD (-0.19 dB; 95% CI, -0.22 to 0.16 dB; P < 0.0001) and abnormally high sensitivity on glaucoma hemifield test (1.14 dB; 95% CI, 0.78-1.51 dB; P < 0.0001) were significantly associated with increased variability. Finally, test-retest MD showed minimal change around the recommended 15% false-positive cutoff threshold. CONCLUSIONS: The variability of SFR increases with worsening threshold sensitivity, is stable over time, and is greater for peripheral compared with central test locations. Worse baseline MD and abnormally high sensitivity are significant predictors of increased variability. A cutoff of 15% in false-positive results may be inappropriate as a threshold for judging test reliability in SFR. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Assuntos
Algoritmos , Pressão Intraocular , Hipertensão Ocular , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Masculino , Estudos Prospectivos , Feminino , Estudos Transversais , Testes de Campo Visual/métodos , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Idoso , Reprodutibilidade dos Testes , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Sensibilidade e Especificidade , Adulto , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Limiar Sensorial/fisiologia
2.
Ophthalmic Physiol Opt ; 44(1): 83-95, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37803502

RESUMO

PURPOSE: To compare clinical visual field outputs in glaucoma and healthy patients returned by the Humphrey Field Analyzer (HFA) and virtual reality (Virtual Field, VF) perimetry. METHODS: One eye of 54 glaucoma patients and 41 healthy subjects was prospectively tested (three times each in random order) using the HFA and VF perimeters (24-2 test grids). We extracted and compared global indices (mean deviation [MD] and pattern standard deviation [PSD]), pointwise sensitivity (and calculated 'equivalent' sensitivity after accounting for differences in background luminance) and pointwise defects. Bland-Altman (mean difference [Mdiff ] and 95% limits of agreement [LoA]) and intraclass correlation analyses were performed. RESULTS: The VF test was shorter (by 76 s) and had lower fixation losses (by 0.08) and false-positive rate (by 0.01) compared to the HFA (all p < 0.0001). Intraclass correlations were 0.86, 0.82 and 0.47 for MD, PSD and pointwise sensitivity between devices, respectively. Test-retest variability was higher for VF (Mdiff 0.3 dB, LoA -7.6 to 8.2 dB) compared to the HFA (Mdiff -0.3 dB, LoA -6.4 to 5.9 dB), indicating greater test-retest variability. When using each device's underlying normative database, the HFA detected, on average, 7 more defects (at the p < 0.05 level) out of the 52 test locations compared to this iteration of VF in the glaucoma cohort. CONCLUSIONS: Virtual Field returns global results that are correlated with the HFA, but pointwise sensitivities were more variable. Differences in test-retest variability and defect detection by its current normative database raise questions about the widespread adoption of VF in lieu of the HFA.


Assuntos
Glaucoma , Realidade Virtual , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Sensibilidade e Especificidade , Reprodutibilidade dos Testes , Glaucoma/diagnóstico
3.
Ophthalmic Physiol Opt ; 44(2): 457-471, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37990841

RESUMO

PURPOSE: To describe variations in ganglion cell-inner plexiform layer (GCIPL) thickness in a healthy cohort from widefield optical coherence tomography (OCT) scans. METHODS: Widefield OCT scans spanning 55° × 45° were acquired from 470 healthy eyes. The GCIPL was automatically segmented using deep learning methods. Thickness measurements were extracted after correction for warpage and retinal tilt. Multiple linear regression analysis was applied to discern trends between global GCIPL thickness and age, axial length and sex. To further characterise age-related change, hierarchical and two-step cluster algorithms were applied to identify locations sharing similar ageing properties, and rates of change were quantified using regression analyses with data pooled by cluster analysis outcomes. RESULTS: Declines in widefield GCIPL thickness with age, increasing axial length and female sex were observed (parameter estimates -0.053, -0.436 and -0.464, p-values <0.001, <0.001 and 0.02, respectively). Cluster analyses revealed concentric, slightly nasally displaced, horseshoe patterns of age-related change in the GCIPL, with up to four statistically distinct clusters outside the macula. Linear regression analyses revealed significant ageing decline in GCIPL thickness across all clusters, with faster rates of change observed at central locations when expressed as absolute (slope = -0.19 centrally vs. -0.04 to -0.12 peripherally) and percentage rates of change (slope = -0.001 centrally vs. -0.0005 peripherally). CONCLUSIONS: Normative variations in GCIPL thickness from widefield OCT with age, axial length and sex were noted, highlighting factors worth considering in further developments. Widefield OCT has promising potential to facilitate quantitative detection of abnormal GCIPL outside standard fields of view.


Assuntos
Macula Lutea , Tomografia de Coerência Óptica , Humanos , Feminino , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina , Fibras Nervosas , Retina
4.
Ophthalmic Physiol Opt ; 44(2): 426-441, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38226742

RESUMO

PURPOSE: To examine the diagnostic accuracy of performing two (frontloaded) versus one (clinical standard) visual field (VF) test per visit for detecting the progression of early glaucoma in data derived from clinical populations. METHODS: A computer simulation model was used to follow the VFs of 10,000 glaucoma patients (derived from two cohorts: Heijl et al., Swedish cohort; and Chauhan et al., Canadian Glaucoma Study [CGS]) over a 10-year period to identify patients whose mean deviation (MD) progression was detected. Core data (baseline MD and progression rates) were extracted from two studies in clinical cohorts of glaucoma, which were modulated using SITA-Faster variability characteristics from previous work. Additional variables included follow-up intervals (six-monthly or yearly) and rates of perimetric data loss for any reason (0%, 15% and 30%). The main outcome measures were the proportions of progressors detected. RESULTS: When the Swedish cohort was reviewed six-monthly, the frontloaded strategy detected more progressors compared to the non-frontloaded method up to years 8, 9 and 10 of follow-up for 0%, 15% and 30% data loss conditions. The time required to detect 50% of cases was 1.0-1.5 years less for frontloading compared to non-frontloading. At 4 years, frontloading increased detection by 26.7%, 28.7% and 32.4% for 0%, 15% and 30% data loss conditions, respectively. Where both techniques detected progression, frontloading detected progressors earlier compared to the non-frontloaded strategy (78.5%-81.5% and by 1.0-1.3 years when reviewed six-monthly; 81%-82.9% and by 1.2-2.1 years when reviewed yearly). Accordingly, these patients had less severe MD scores (six-monthly review: 0.63-1.67 dB 'saved'; yearly review: 1.10-2.87 dB). The differences increased with higher rates of data loss. Similar tendencies were noted when applied to the CGS cohort. CONCLUSIONS: Frontloaded VFs applied to clinical distributions of MD and progression led to earlier detection of early glaucoma progression.


Assuntos
Glaucoma , Testes de Campo Visual , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Pressão Intraocular , Simulação por Computador , Seguimentos , Estudos Retrospectivos , Transtornos da Visão/diagnóstico , Progressão da Doença , Canadá , Glaucoma/diagnóstico
5.
Ophthalmology ; 130(11): 1138-1148, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37385298

RESUMO

PURPOSE: Frontloading SITA-Faster (SFR) visual fields (2 tests per eye on the same visit) has been shown to provide repeatable perimetric data at minimal time cost. This study reports the outcomes of using frontloaded SFR in the evaluation of pointwise visual field (VF) defects in a cohort of patients with glaucoma when transitioned from SITA-Standard (SS). DESIGN: Prospective, cross-sectional study. PARTICIPANTS: A total of 144 eyes of 91 patients with confirmed or suspected glaucoma who had an SS test on a previous visit. METHODS: Two SFR tests (T1, T2) per eye on the same visit. MAIN OUTCOME MEASURES: Global sensitivity, reliability indices, and pointwise deviation map probability scores from the pattern deviation grid of each patient were compared across the 3 sequential tests to evaluate the consistency of VF defects. RESULTS: The mean age was 68.6 years, and 79.2% of patients had a diagnosis of glaucoma. There was no significant difference in mean deviation (MD) across the 3 tests (-5.83 decibels [dB], -5.28 dB, and -5.71 dB in SS, SFR1, and SFR2, respectively, repeated-measures analysis of variance [ANOVA], P = 0.48). The frontloaded SFR tests provided repeatable VFs that confirmed existing pointwise data on the SS in 4661 (62.3%) locations, reversed an SS defect in 614 (8.2%) locations, and demonstrated a new repeatable defect in 406 (5.4%) locations of the pattern deviation grid. A new defect of at least 3 contiguous points was identified in 20.1% of eyes. The non-repeatable points on the 2 SFR tests displayed no significant difference in the distribution of defect/nondefect points based on test order or peripheral versus central locations. There was no significant difference in the rate of obtaining at least 1 reliable test result between SS and the frontloaded SFR T1 and T2 (P = 0.77). Test duration significantly decreased from SS to SFR1/2 (379 vs. 160 vs. 158 seconds, P < 0.0001). CONCLUSIONS: Frontloading SFR tests can provide repeatable data for the evaluation of the consistency of pattern deviation defects in glaucoma, with no observable decline in performance from test fatigue. This is achieved at equivalent duration and reliability as a single SS test. Frontloading SFR may be helpful in increasing testing frequency/quantity to meet recommended guidelines for progression analysis. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

6.
Ophthalmic Physiol Opt ; 43(5): 1278-1293, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37252721

RESUMO

PURPOSE: Age-related macular degeneration (AMD) is a major cause of vision loss globally. Patients with AMD may not always understand or retain the information about AMD communicated by their eyecare practitioner. This study aims to explore the characteristics of effective health communication for AMD, from both patients' and eyecare practitioners' perspectives. The purpose is to provide a foundation for understanding how health communication for AMD could potentially be improved in the future. METHODS: A total of 10 focus groups involving 17 patients with AMD and 17 optometrists were conducted via web conferencing. Each session was audio-recorded, transcribed and analysed using the Grounded Theory Methodology. RESULTS: The five themes identified are as follows: (1) materials' quality, (2) materials' relevance, (3) contextualising for the individual, (4) contextualising for the disease and (5) support network. Participants expressed concern about the unrealistic yet common depiction of vision loss in AMD as a black patch overlying common visual scenes. They also preferred education materials tailored to a specific disease stage and the regular opportunity to ask or answer questions. Longer appointment durations and peer support (from family, friends or others with AMD) were also valued. CONCLUSION: Optometrists are encouraged to focus on three over-arching dimensions when counselling patients with AMD in routine clinical practice: (1) curating and using disease and stage-specific, impactful education materials, (2) their chairside verbal communication techniques and (3) AMD-specific opportunities for care coordination among patient family and friends, peers and other multidisciplinary members of the care support team.


Assuntos
Comunicação em Saúde , Degeneração Macular , Humanos , Degeneração Macular/diagnóstico , Degeneração Macular/terapia , Pesquisa Qualitativa , Transtornos da Visão , Grupos Focais , Cegueira
7.
Ophthalmic Physiol Opt ; 43(4): 668-679, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36786498

RESUMO

INTRODUCTION: The purpose of this study was to build an automated age-related macular degeneration (AMD) colour fundus photography (CFP) recognition method that incorporates confounders (other ocular diseases) and normal age-related changes by using drusen masks for spatial feature supervision. METHODS: A range of clinical sources were used to acquire 7588 CFPs. Contrast limited adaptive histogram equalisation was used for pre-processing. ResNet50 was used as the backbone network, and a spatial attention block was added to integrate prior knowledge of drusen features into the backbone. The evaluation metrics used were sensitivity, specificity and F1 score, which is the harmonic mean of precision and recall (sensitivity) and area under the receiver-operating characteristic (AUC). Fivefold cross-validation was performed, and the results compared with four other methods. RESULTS: Excellent discrimination results were obtained with the algorithm. On the public dataset (n = 6565), the proposed method achieved a mean (SD) sensitivity of 0.54 (0.09), specificity of 0.99 (0.00), F1 score of 0.62 (0.06) and AUC of 0.92 (0.02). On the private dataset (n = 1023), the proposed method achieved a sensitivity of 0.92 (0.02), specificity of 0.98 (0.01), F1 score of 0.92 (0.01) and AUC of 0.98 (0.01). CONCLUSION: The proposed drusen-aware model outperformed baseline and other vessel feature-based methods in F1 and AUC on the AMD/normal CFP classification task and achieved comparable results on datasets that included other diseases that often confound classification. The method also improved results when a five-category grading protocol was used, thereby reflecting discriminative ability of the algorithm within a real-life clinical setting.


Assuntos
Degeneração Macular , Drusas Retinianas , Humanos , Drusas Retinianas/diagnóstico , Degeneração Macular/diagnóstico , Retina , Algoritmos , Curva ROC
8.
Ophthalmic Physiol Opt ; 43(1): 46-63, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36416369

RESUMO

PURPOSE: To analyse optical coherence tomography (OCT)-derived inner nuclear layer (INL) and outer retinal complex (ORC) measurements relative to ganglion cell-inner plexiform layer (GCIPL) measurements in glaucoma. METHODS: Glaucoma participants (n = 271) were categorised by 10-2 visual field defect type. Differences in GCIPL, INL and ORC thickness were calculated between glaucoma and matched healthy eyes (n = 548). Hierarchical cluster algorithms were applied to generate topographic patterns of retinal thickness change, with agreement between layers assessed using Cohen's kappa (κ). Differences in GCIPL, INL and ORC thickness within and outside GCIPL regions showing the greatest reductions and Spearman's correlations between layer pairs were compared with 10-2 mean deviation (MD) and pattern standard deviation (PSD) to determine trends with glaucoma severity. RESULTS: Glaucoma participants with inferior and superior defects presented with concordant GCIPL and INL defects demonstrating mostly fair-to-moderate agreement (κ = 0.145-0.540), which was not observed in eyes with no or ring defects (κ = -0.067-0.230). Correlations (r) with MD and PSD were moderate and weak in GCIPL and INL thickness differences, respectively (GCIPL vs. MD r = 0.479, GCIPL vs. PSD r = -0.583, INL vs. MD r = 0.259, INL vs. PSD r = -0.187, p = <0.0001-0.002), and weak in GCIPL-INL correlations (MD r = 0.175, p = 0.004 and PSD r = 0.154, p = 0.01). No consistent patterns in ORC thickness or correlations were observed. CONCLUSIONS: In glaucoma, concordant reductions in macular INL and GCIPL thickness can be observed, but reductions in ORC thickness appear unlikely. These findings suggest that trans-synaptic retrograde degeneration may occur in glaucoma and could indicate the usefulness of INL thickness in evaluating glaucomatous damage.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Humanos , Glaucoma/diagnóstico
9.
Ophthalmic Physiol Opt ; 43(4): 771-787, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36964934

RESUMO

PURPOSE: To determine whether there are quantifiable structural or functional differences that can distinguish between high-tension glaucoma (HTG; intraocular pressure [IOP] > 21 mm Hg) and low-tension glaucoma (LTG; IOP ≤ 21 mm Hg) at diagnosis. METHOD: This was a retrospective, cross-sectional study. Clinical results of one eye from 90 newly diagnosed HTG and 319 newly diagnosed LTG patients (117 with very-low-tension glaucoma [vLTG; ≤15 mm Hg] and 202 with middling LTG [mLTG; >15 mm Hg, ≤21 mm Hg]) were extracted, which included relevant demographic covariates of glaucoma, quantitative optical coherence tomography (including the optic nerve head, retinal nerve fibre layer and ganglion cell-inner plexiform layer) measurements and standard automated perimetry global metrics. We used binary logistic regression analysis to identify statistically significant clinical parameters distinguishing between phenotypic groups for inclusion in principal component (PC) (factor) analysis (PCA). The separability between each centroid for each cohort was calculated using the Euclidean distance (d(x,y)). RESULTS: The binary logistic regression comparing HTG and all LTG identified eight statistically significant clinical parameters. Subsequent PCA results included three PCs with an eigenvalue >1. PCs 1 and 2 accounted for 21.2% and 20.2% of the model, respectively, with a d(x,y) = 0.468, indicating low separability between HTG and LTG. The analysis comparing vLTG, mLTG and HTG identified 15 significant clinical parameters, which were subsequently grouped into five PCs. PCs 1 and 2 accounted for 24.1% and 17.8%, respectively. The largest separation was observed between vLTG and HTG (d(x,y) = 0.581), followed by vLTG and mLTG (d(x,y) = 0.435) and lastly mLTG and HTG (d(x,y) = 0.210). CONCLUSION: Conventional quantitative structural or functional parameters could not distinguish between pressure-defined glaucoma phenotypes at the point of diagnosis and are therefore not contributory to separating cohorts. The overlap in findings highlights the heterogeneity of the primary open-angle glaucoma clinical presentations among pressure-defined groups at the cohort level.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Estudos Transversais , Estudos Retrospectivos , Células Ganglionares da Retina , Pressão Intraocular , Testes de Campo Visual , Tomografia de Coerência Óptica/métodos
10.
Ophthalmic Physiol Opt ; 42(5): 973-985, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35598152

RESUMO

PURPOSE: To determine the usefulness of Humphrey Field Analyser (HFA) SITA-Faster 24-2 gaze tracker outputs on interpreting intra-visit visual field (VF) result pairs. METHODS: Analysis of 1380 right-left eye pairs and 1432 pairs of test 1-test 2 intrasession VF results of patients seen within a university-based glaucoma service was undertaken to understand gaze deviation distributions. Output gaze tracker results were aggregated into total ticks, sum of amplitudes and average amplitudes. Correlations between visual field indices (mean deviation [MD], "events" and overall hill of vision) and independent variables (age and test order) were performed using one eye from each subject. RESULTS: There was no association of test order (right-left, test 1-test 2) with eye movements. There was a significant, but weak correlation between eye movements and age (r = 0.16). Correlations of eye movements with MD were driven by more severe MD values. There were no significant correlations between intrasession difference in eye movements and the change in MD, number of "events" and hill of vision, or in the root mean square of sensitivity and total deviation values. There was also no significant correlation between gaze tracker outputs and another commonly used "reliability" metric, false positive rate. CONCLUSIONS: Eye movement parameters as currently reported by the HFA do not appear to be correlated with key sensitivity parameters when considering the repeatability of intrasession SITA-Faster 24-2 VF results. Thus, current gaze tracker outputs do not appear to provide clinically meaningful information for interpretation of intra-visit visual field results that cannot already be garnered using other strategies.


Assuntos
Glaucoma , Campos Visuais , Olho , Movimentos Oculares , Humanos , Reprodutibilidade dos Testes , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos
11.
Ophthalmic Physiol Opt ; 42(4): 839-848, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35521818

RESUMO

PURPOSE: Age-related macular degeneration (AMD) is a leading cause of vision loss. It is helpful for patients living with AMD to understand the prognosis, risk factors and management of their condition. Online education materials are a popular and promising channel for conveying this knowledge to patients with AMD. However, the quality of these materials-particularly with respect to qualities such as 'understandability' and 'actionability'-is not yet known. This study assessed a collection of online materials about AMD based on these qualities of 'understandability' and 'actionability'. METHODS: Online education materials about AMD were sourced through Google from six English-speaking nations: Australia, New Zealand, USA, UK, Ireland and Canada. Three Australian/New Zealand trained and registered optometrists participated in the grading of the 'understandability' and 'actionability' of online education materials using the Patient Education Materials Assessment Tool (PEMAT). RESULTS: This study analysed a total of 75 online materials. The mean 'understandability' score was 74% (range: 38%-94%). The 'understandability' PEMAT criterion U11 (calling for a summary of the key points) scored most poorly across all materials. The mean 'actionability' score was 49% (range: 0%-83%). The 'actionability' PEMAT criterion A26 (using 'visual aids' to make instructions easier to act on) scored most poorly across all materials. CONCLUSION: Most education materials about AMD are easy to understand, but difficult to act on, because of a lack of meaningful visual aids. We propose future enhancements to AMD education materials-including the use of summaries, visual aids and a habit tracker-to help patients with AMD improve their understanding of disease prognosis, risk factors and eye assessment schedule requirements.


Assuntos
Letramento em Saúde , Degeneração Macular , Austrália , Compreensão , Humanos , Degeneração Macular/diagnóstico , Degeneração Macular/terapia , Educação de Pacientes como Assunto
12.
Ophthalmic Physiol Opt ; 42(1): 161-177, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34843120

RESUMO

PURPOSE: There is growing interest in functional testing for early/intermediate age-related macular degeneration (iAMD). However, systematic evaluation of existing clinical functional tests is lacking. This systematic review examines evidence for using clinical automated perimetry in routine assessment of early/iAMD. RECENT FINDINGS: PubMed, Web of Science Core Collection, and Embase were searched from inception to October 2020 to answer, is there evidence of visual field defects in early/iAMD, and if so, are early/iAMD visual field defects linked to real-world patient outcomes? Articles using clinical automated perimetry (commercially accessible and non-modified devices/protocols) were included. Microperimetry was excluded as this has yet to be incorporated into clinical guidelines. The primary outcome was global visual field indices including mean deviation (MD), pattern standard deviation (PSD), mean sensitivity (MS) and frequency of defects. The secondary outcome was any real-world patient outcome including quality of life and/or activities of daily living indices. Twenty-six studies were eligible for inclusion and all studies were observational. There was consistent evidence of worsened MD, PSD, MS and frequency of defects for early/iAMD compared to normal eyes under photopic, low-photopic and scotopic conditions. Meta-analysis of studies using standard automated perimetry (SAP) under photopic conditions revealed worsened MD (-1.52dB [-2.27, -0.78 dB]) and MS (-1.47dB [-2, -0.94 dB]) in early/iAMD compared to normal eyes, representing large statistical effect sizes but non-clinically meaningful reductions. There was insufficient data for meta-analyses regarding other clinical automated perimetry protocols. Only one study assessed a real-world patient outcome (on-road driving performance), with no significant link to visual field outcomes in early/iAMD. SUMMARY: Significant reduction of global visual field indices is present in early/iAMD, but not clinically meaningful using SAP under photopic conditions. Translational relevance of visual field outcomes to patient outcomes in early/iAMD remains unclear. Thus, SAP under photopic conditions is unlikely to be useful for routine assessment of early/iAMD.


Assuntos
Degeneração Macular , Testes de Campo Visual , Atividades Cotidianas , Humanos , Degeneração Macular/diagnóstico , Qualidade de Vida , Testes de Campo Visual/métodos , Campos Visuais
13.
Ophthalmic Physiol Opt ; 42(5): 948-964, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35598146

RESUMO

PURPOSE: To assess the accuracy of cluster analysis-based models in predicting visual field (VF) defects from macular ganglion cell-inner plexiform layer (GCIPL) measurements in glaucomatous and healthy cohorts. METHODS: GCIPL measurements were extracted from posterior pole optical coherence tomography (OCT), from locations corresponding to central VF test grids. Models incorporating cluster analysis methods and corrections for age and fovea to optic disc tilt were developed from 493 healthy participants, and 5th and 1st percentile limits of GCIPL thickness were derived. These limits were compared with pointwise 5th and 1st percentile limits by calculating sensitivities and specificities in an additional 40 normal and 37 glaucomatous participants, as well as applying receiver operating characteristic (ROC) curve analyses to assess the accuracy of predicting VF results from co-localised GCIPL measurements. RESULTS: Clustered models demonstrated globally low sensitivity, but high specificity in the glaucoma cohort (0.28-0.53 and 0.77-0.91, respectively), and high specificity in the healthy cohort (0.91-0.98). Clustered models showed similar sensitivities and superior specificities compared with pointwise methods (0.41-0.65 and 0.71-0.98, respectively). There were significant differences in accuracy between clusters, with relatively poor accuracy at peripheral macular locations (p < 0.0001 for all comparisons). CONCLUSIONS: Cluster analysis-based models incorporating age correction and holistic consideration of fovea to optic disc tilt demonstrated superior performance in predicting VF results to pointwise methods in both glaucomatous and healthy eyes. However, relatively low sensitivity and poorer performance at the peripheral macula indicate that OCT in isolation may be insufficient to predict visual function across the macula accurately. With modifications to criteria for abnormality, the concepts suggested by the described normative models may guide prioritisation of VF assessment requirements, with the potential to limit excessive VF testing.


Assuntos
Glaucoma , Tomografia de Coerência Óptica , Análise por Conglomerados , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos , Transtornos da Visão , Acuidade Visual , Testes de Campo Visual , Campos Visuais
14.
Ophthalmology ; 128(10): 1405-1416, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33722636

RESUMO

PURPOSE: To compare the ability of 24-2C and 10-2 test grids in measuring visual field global indices, identifying central visual field defects, and facilitating macular structure-function analysis with OCT scans in glaucoma and glaucoma suspect patients. DESIGN: Prospective, cross-sectional study. PARTICIPANTS: One eye from 131 glaucoma and 57 glaucoma suspect patients recruited from a referral-only, university-based glaucoma clinic. METHODS: Each subject underwent perimetric testing using 24-2C SITA-Faster and 10-2 SITA-Fast in random order, and Cirrus OCT macular imaging (Ganglion Cell Analysis) for structure-function correlations. MAIN OUTCOME MEASURES: Visual field global indices (mean deviation, pattern standard deviation, binarized "cluster" pass/fail, and central mean sensitivity), number and proportion of visual field defects, and structure-function concordance with the Cirrus OCT deviation map following visual field location displacement for correspondence with underlying retinal ganglion cell position. RESULTS: Global indices (mean deviation, pattern standard deviation, and central mean sensitivity) were similar between both grids. The 10-2 detected more defects compared with the 24-2C (P < 0.0001 for all patients, P = 0.006 for glaucoma patients). This was preserved when analyzing the proportion of defects in the central visual field for all patients (P = 0.02) but was not significantly different for glaucoma patients (P = 0.051). The 10-2 identified more central "clusters" of 2+ contiguous points of deficit (P < 0.0001). Structure-function comparisons performed at locations where visual field and OCT test locations were colocalized revealed greater concordance of structural and functional deficits using the 10-2 (P < 0.0001). The 10-2 took a median of 201 seconds, and the 24-2C took a median of 154 seconds, corresponding to the different thresholding algorithms. CONCLUSIONS: The 24-2C and 10-2 test grids return similar global indices of visual field performance and proportionally similar amounts of central visual field loss. The additional points in the 10-2 grid return more "clusters" of defects and a greater rate of structure-function concordance compared with the 24-2C test grid. Thus, the 24-2C can identify the presence of a clustered central visual field defect using similar probability criteria, whereas the 10-2 may be more useful in comprehensively characterizing the defect and predicting central visual function.


Assuntos
Algoritmos , Glaucoma/complicações , Células Ganglionares da Retina/patologia , Escotoma/etiologia , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Idoso , Estudos Transversais , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Escotoma/diagnóstico , Escotoma/fisiopatologia
15.
Optom Vis Sci ; 98(11): 1321-1331, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34538849

RESUMO

SIGNIFICANCE: Intraocular pressure (IOP) profiling is an important component of the glaucoma examination. Two techniques for profiling are the water drinking test (WDT) and iCare HOME phasing, but the correlations between techniques and their ease of deployment have not been studied. These questions are important in determining suitability for clinical deployment. PURPOSE: This study aimed to compare the IOP results of the WDT and iCare HOME phasing in patients with suspected or newly diagnosed glaucoma. METHODS: Ninety-eight consecutive patients attending a glaucoma clinic underwent IOP profiling using both techniques. For the WDT, patients ingested 10 mL/kg body weight of water after a baseline applanation IOP measurement and then underwent serial IOP measurements approximately every 15 minutes, ceasing after 30 minutes of consecutive measurements within 3 mmHg of baseline. Patients successfully certified for self-administration of the iCare HOME were loaned the instrument for 1 week and instructed to take four measurements per day. RESULTS: Twenty-seven patients (28%) successfully obtained four measurements per day using iCare HOME, and 96 patients (98%) were able to complete the WDT. Intraocular pressure profiles showed no difference between the time for peak IOP and across nearly all IOP parameters obtained from profiling except for the standard deviation of IOP measurements obtained using the iCare HOME (P = .005). There were moderate correlations between peak IOPs obtained using each technique (r = 0.67, P = .001, right eye; r = 0.66, P = .002, left eye) but no correlation between the daily range (iCare HOME) or peak-trough difference (WDT; r = 0.21, P = .28, right eye; r = 0.27, P = .02, left eye). Bland-Altman analysis returned similar results for peak and range. CONCLUSIONS: Intraocular pressure profiling using both techniques can reveal the peak IOP, and these measurements are strongly correlated. Most patients were unable to complete the iCare HOME according to the manufacturer's recommendations. Clinicians should select the most appropriate technique for each patient.


Assuntos
Glaucoma , Pressão Intraocular , Glaucoma/diagnóstico , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tonometria Ocular , Água
16.
Optom Vis Sci ; 98(4): 310-325, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33828038

RESUMO

SIGNIFICANCE: This article summarizes the evidence for a higher prevalence of binocular vision dysfunctions in individuals with vision impairment. Assessment for and identification of binocular vision dysfunctions can detect individuals experiencing difficulties in activities including reading, object placement tasks, and mobility.Comprehensive vision assessment in low vision populations is necessary to identify the extent of remaining vision and to enable directed rehabilitation efforts. In patients with vision impairment, little attention is typically paid to assessments of binocular vision, including ocular vergence, stereopsis, and binocular summation characteristics. In addition, binocular measurements of threshold automated visual fields are not routinely performed in clinical practice, leading to an incomplete understanding of individuals' binocular visual field and may affect rehabilitation outcomes.First, this review summarizes the prevalence of dysfunctions in ocular vergence, stereopsis, and binocular summation characteristics across a variety of ocular pathologies causing vision impairment. Second, this review examines the links between clinical measurements of binocular visual functions and outcome measures including quality of life and performance in functional tasks. There is an increased prevalence of dysfunctions in ocular alignment, stereopsis, and binocular summation across low vision cohorts compared with those with normal vision. The identification of binocular vision dysfunctions during routine low vision assessments is especially important in patients experiencing difficulties in activities of daily living, including but not limited to reading, object placement tasks, and mobility. However, further research is required to determine whether addressing the identified deficits in binocular vision in low vision rehabilitative efforts directly impacts patient outcomes.


Assuntos
Visão Binocular/fisiologia , Baixa Visão/fisiopatologia , Atividades Cotidianas/psicologia , Percepção de Profundidade/fisiologia , Humanos , Qualidade de Vida/psicologia , Leitura , Baixa Visão/psicologia , Campos Visuais/fisiologia , Percepção Visual/fisiologia , Pessoas com Deficiência Visual
17.
Optom Vis Sci ; 98(8): 901-913, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34393206

RESUMO

SIGNIFICANCE: Assessment of treatment efficacy via comparison with a target IOP is fundamental in monitoring patients with open-angle glaucoma and ocular hypertension. This article highlights that diurnal IOP fluctuations obtained using self-tonometry may more accurately reflect IOP responses to therapy. PURPOSE: This study aimed to investigate fluctuations in diurnal IOP measurements in patients with open-angle glaucoma and ocular hypertension treated with latanoprost 0.005% and timolol 0.25%. METHODS: In this crossover treatment trial, 14 participants performed self-tonometry with iCare HOME 4 times daily for (1) 1 week using latanoprost, (2) 4 weeks using no medications, and (3) 2 weeks using timolol. Daily peak IOPs, IOP fluctuations, and mean IOPs from different treatments were compared on an individual basis. Treatment efficacy between medications was assessed by comparing mean percentage IOP reductions with latanoprost and timolol across participants. In addition, effects of age, years since commencing latanoprost, sex, and diagnosis were investigated, and peak IOP times were compared with assess impacts on diurnal profiles. RESULTS: Between individuals, IOP responses ranged from reductions in peak IOPs, IOP fluctuations, and mean IOPs on both medications to no change in any parameter and medication. IOP fluctuations showed greater mean percentage reductions than did peak and mean IOPs (χ2 = 16.51, P = .002). There were significant associations between years since commencing latanoprost and peak and mean IOP responses on timolol (r = 0.69, P = .007), and sex and relative reductions in IOP fluctuations on both medications (P = .03). There were no differences in peak IOP times between treatment conditions. CONCLUSIONS: Despite variability in IOP responses to latanoprost and timolol, IOP fluctuation with self-tonometry was more consistent in evaluating target IOP, reflecting its importance in ascertaining true IOP response to topical therapies. These findings may impact clinical decision making based on target IOP criteria in patients on topical therapy.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Hipertensão Ocular , Prostaglandinas F Sintéticas , Anti-Hipertensivos/uso terapêutico , Combinação de Medicamentos , Glaucoma/tratamento farmacológico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Humanos , Pressão Intraocular , Latanoprosta , Manometria , Hipertensão Ocular/tratamento farmacológico , Timolol , Resultado do Tratamento
18.
Ophthalmic Physiol Opt ; 41(6): 1273-1284, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34490921

RESUMO

PURPOSE: Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatability of Pentacam Scheimpflug photography for measuring the ACD across the chamber width in healthy subjects and thus inform expected limits of normality. METHODS: Pentacam Scheimpflug photography was used to obtain ACD measurements at 57 points across the central 8mm of the chamber width from one randomly selected eye of 130 healthy (normal vision and no ocular diseases, except age-normal cataracts) subjects (median age 58.0 years, interquartile range 46.3-63.0 years; 48 males, 82 females). Intra-session ACD measurements were compared. Univariate and multivariate linear regression was performed to identify categorical and continuous variables demonstrating a significant relationship with ACD and its repeatability. RESULTS: Bland-Altman analyses showed no directional or depth-dependent bias in the difference between the first and second tests (mean bias -0.003 mm, 95% limits of agreement -0.115 to +0.109 mm). Multivariate analysis found gender to be a significant factor (p < 0.0001), but not age (p = 0.69) nor ethnicity (p = 0.65), although the model fit was poor (R2  = 0.004). There were no regional differences in repeatability measures found in males, but six locations in the superior aspect in females were found to be significantly different in their repeatability characteristics. Tolerance limits used to calculate the number of step sizes between <20 and >60-year-old age groups found 8.1-11.5 steps for females, and 7.5-9.2 steps for males. CONCLUSIONS: Scheimpflug imaging using the Pentacam has excellent intra-session repeatability. Only gender appeared to affect repeatability characteristics, manifesting with a greater number of meaningful steps of change between two extremes of age range in females compared to males, which provides guidance for identifying clinically significant and measurable change between tests.


Assuntos
Câmara Anterior , Técnicas de Diagnóstico Oftalmológico , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Fotografação , Reprodutibilidade dos Testes
19.
Ophthalmic Physiol Opt ; 41(4): 768-781, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33682940

RESUMO

PURPOSE: A fundamental clinical skill is the recognition of artefacts within the outputs of advanced imaging modalities. However, current teaching programmes of healthcare practitioners are becoming increasingly challenged to provide practical exposure within an already crowded curriculum. This study evaluates the impact of a novel work-integrated teaching model on the confidence and competence of clinicians in the use of optical coherence tomography (OCT) and the recognition of its artefacts. The outcomes were then used to develop a model to predict performance and guide teaching strategies. METHODS: We prospectively evaluated a 6-week clinical placement for final year optometry students within a diagnostic eye clinic in 2018-2020. Participants completed a quiz on the identification of common OCT artefacts and rated their confidence levels on key areas of OCT application using a five-point Likert scale. Both were completed before (pre-rotation) and after (post-rotation) the placement. The cohort was divided into two groups; the first group was used to assess the impact of the placement and derive the prediction model for post-placement performance, which was then validated against the second group. RESULTS: A significant improvement in detecting OCT imaging artefacts was seen upon completion of the placement, which was greater in participants with lower entry level performance. Across all OCT artefact subtypes, there was an improvement in detecting segmentation error, delineation error and media opacities. A model predicting post-placement student performance was developed using entry level knowledge base as the key dependent variable. Self-rated confidence improved across all domains of OCT application but was not found to be a direct predictor of actual performance. CONCLUSIONS: These results highlight the benefit of a work-integrated learning programme on both academic performance and confidence whilst identifying entry level knowledge base as the key variable predicting improvement. Tailored teaching incorporating entering knowledge is the best predictor of improvement during clinical placements. Integrating clinicians into a work-integrated setting with tailored teaching and comprehensive practical exposure can be an effective method for training future or current healthcare professionals.


Assuntos
Competência Clínica , Optometria , Olho , Humanos , Estudantes , Ensino , Tomografia de Coerência Óptica
20.
Optom Vis Sci ; 97(2): 86-93, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32011580

RESUMO

SIGNIFICANCE: Icare HOME rebound tonometry is increasingly adopted into clinical practice for IOP phasing of glaucoma patients and suspects. Because of measurement differences with applanation tonometry and diurnal fluctuations, interpretation of the IOP measured with Icare HOME phasing can be challenging. PURPOSE: The purpose of this study was to use a large patient cohort to develop a practical, analytical tool for interpreting Icare HOME measurements with respect to applanation pressure. METHODS: IOP measurements using the Icare HOME and an applanation tonometer were taken prospectively in 498 consecutive patients. Bland-Altman, frequency distribution, and linear regression analysis were applied to determine measurement differences. A novel criterion, Threshold Icare HOME IOP, was developed to assist identification of elevation above target applanation pressure, considering the expected diurnal variation and measurement variability. RESULTS: Icare HOME tended to underestimate applanation tonometry (mean bias, -1.7 mmHg; 95% limits of agreement, -7.0 to +3.6). Overall, differences were within ±3 mmHg in 71.5% and ±5 mmHg in 92% of patients. Based on the novel criterion developed, Icare HOME measurements that exceed target applanation pressure by 6 mmHg or greater are generally outside the 95% limit of expected observations. CONCLUSIONS: The Threshold Icare HOME IOP is a novel and practical criterion that can assist clinicians in their interpretation of Icare HOME phasing measurements with respect to target applanation pressures. Elevation above the expected thresholds may prompt closer monitoring or even modifications to glaucoma management.


Assuntos
Pressão Intraocular/fisiologia , Hipertensão Ocular/diagnóstico , Autocuidado/métodos , Tonometria Ocular/métodos , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Hipertensão Ocular/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA