Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Clin Pharmacol Ther ; 59(9): 627-629, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34190685

RESUMO

Linezolid is used to treat prosthetic joint infection after total hip arthroplasty. Here, we present a case of linezolid-induced severe neutropenia, which improved after switching to tedizolid. Grade 3 neutropenia developed 5 days after linezolid injection (1,200 mg/day) and 33 days after oral administration of the same dose. However, during the 70 days of treatment with tedizolid, grade 3 neutropenia did not occur, and C-reactive protein levels remained in the normal range. No grade ≥ 1 thrombocytopenia or bleeding event occurred during the course of tedizolid treatment. Tedizolid may be an alternative drug for patients who develop linezolid-induced neutropenia.


Assuntos
Neutropenia , Dermatopatias Bacterianas , Antibacterianos/efeitos adversos , Humanos , Linezolida/efeitos adversos , Testes de Sensibilidade Microbiana , Neutropenia/induzido quimicamente , Neutropenia/diagnóstico , Organofosfatos/efeitos adversos , Oxazóis , Oxazolidinonas , Dermatopatias Bacterianas/tratamento farmacológico , Tetrazóis
2.
J Arthroplasty ; 35(3): 811-817, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31685396

RESUMO

BACKGROUND: Modular stems are useful for total hip arthroplasty (THA) in anatomically difficult dysplasia. Here, we present mean 6.8-year outcomes of cementless primary THA using S-ROM-A (modified modular stem for Asian patients) femoral prosthesis in anatomically difficult cases. METHODS: Charts of 373 patients (461 hips) undergoing THA (mean age, 58 years) were reviewed for clinical evaluation of modified Merle d'Aubigné-Postel score and Kaplan-Meier survivorship with revision for any reason as the end point. For radiographic analysis, 331 patients (412 hips) followed up for ≥5 years were included. Bearing couples were metal-on-metal (n = 145), metal-on-polyethylene (n = 120), and ceramic-on-polyethylene (n = 147). Radiography and multiplanar computed tomography were performed. RESULTS: No postoperative dislocation or deep infection occurred. Mean modified Merle d'Aubigné-Postel score improved significantly (10.9 points preoperatively, 16.7 points at last follow-up; P < .001). Cumulative 5- and 10-year stem survival rates were 100% and 84%, respectively (95% confidence interval, 75%-93%). All stems were classified as bone ingrown fixation. Osteolysis occurred in metal-on-metal (42.8%) and metal-on-polyethylene (15.8%) groups. Mean time to osteolysis was ~3 years, with no significant difference between 3 groups (P = .264). In logistic regression, lower cup inclination angle was significantly associated with osteolysis (odds ratio, 0.914; 95% confidence interval, 0.84-0.99; P = .029). CONCLUSION: S-ROM-A femoral prosthesis achieved excellent midterm fixation, and the modular system was useful in primary THA with severe deformity. Bearing couples are potentially associated with adverse reactions to metal debris. S-ROM-A with ceramic-on-polyethylene bearing couples may be an option for anatomically difficult THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Povo Asiático , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Osteólise/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
3.
Arch Orthop Trauma Surg ; 140(1): 129-137, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31696320

RESUMO

INTRODUCTION: While numerous classifications of hip arthritis have been proposed, none considered the magnitude and direction of femoral head translation relative to the native acetabulum. A more precise classification of architectural hip deformities is necessary to improve preoperative templating and anticipate surgical challenges of total hip arthroplasty (THA). The purpose of the present study was to introduce a classification system to distinguish different types of architectural hip deformities, based on femoral head translation patterns, and to evaluate its repeatability using plain radiographs (qualitative) and Computed Tomography (CT) measurements (quantitative). MATERIALS AND METHODS: We studied pre-operative frontal and lateral hip radiographs and CT scans of 191 hips (184 patients) that received primary THA. The distance between the femoral head center (FC) and the acetabular center (AC) was measured, as well as femoral offset, acetabular offset, head center height, acetabular floor distance and femoral neck angle. The hips were classified qualitatively using frontal plain radiographs, and then quantitatively using CT scans (with an arbitrary threshold of 3 mm as Centered, Medialized, Lateralized, Proximalized or Proximo-lateralized. The agreement between qualitative and quantitative classification methods was compared for applying the same classification. RESULTS: Qualitative classification identified 120 centered (63%), 8 medialized (4%), 49 lateralized (26%), 3 proximalized (2%), and 11 proximo-lateralized (6%) hips, while quantitative classification identified 116 centered (61%), 8 medialized (4%), 51 lateralized (27%), 5 proximalized (3%), and 11 proximo-lateralized (6%) hips. The agreement between the two methods was excellent (0.94; CI 0.90-0.98). Medialization reached 9.7 mm, while lateralization reached 10.9 mm, and proximalization reached 8.5 mm. Proximalized and proximo-lateralized hips had more valgus necks, while medialized hips had more varus necks (p = 0.003). CONCLUSIONS: The classification system enabled repeatable distinction of 5 types of architectural hip deformities. The excellent agreement between quantitative and qualitative methods suggests that plain radiographs are sufficient to classify architectural hip deformities.


Assuntos
Acetábulo , Artroplastia de Quadril/métodos , Cabeça do Fêmur , Articulação do Quadril , Artropatias , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Estudos de Coortes , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Artropatias/classificação , Artropatias/diagnóstico por imagem , Artropatias/cirurgia , Cuidados Pré-Operatórios , Radiografia , Tomografia Computadorizada por Raios X
4.
Arch Orthop Trauma Surg ; 140(10): 1585, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32889564

RESUMO

The original version of this article unfortunately contained a mistake. The spelling of the Geert Pagenstert name was incorrect.

5.
Arch Orthop Trauma Surg ; 140(4): 563-573, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31974695

RESUMO

INTRODUCTION: Few studies evaluated clinical benefits of pre-operative templating in total hip arthroplasty (THA). We investigated whether mismatch between planned and real implant sizes and medio-lateral offsets compromises THA outcomes. MATERIALS AND METHODS: We reviewed records of 184 primary THAs with pre-operative CT scans used for templating. Acetabular offset (AO), femoral offset (FO) and global offset (GO) were measured on pre-operative CT scans, during acetate templating, and post-operative antero-posterior radiographs. Multivariable analyses were performed to determine if Forgotten Joint Score (FJS) and Oxford Hip Score (OHS) at > 2 years were associated with differences between post-operative and planned parameters. RESULTS: The FJS and OHS were not influenced by mismatch of component sizes nor of FO and GO. The FJS was better when the post-operative AO was greater than planned (p = 0.050). The FJS differed among arthritic types (p = 0.015). Multivariable analyses confirmed that older patients had better OHS (beta - 0.16; p = 0.033) and FJS (beta 0.74; p = 0.002), medialized hips had worse FJS (beta - 20.1; p = 0.041) and hips with greater AO than planned had better FJS (beta 1.71; p = 0.024) CONCLUSIONS: Implanting a component of different size than planned did not compromise THA outcomes, but medialized hips had worse scores, and conservative acetabular reaming improved scores.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cuidados Pré-Operatórios , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/estatística & dados numéricos , Humanos , Cuidados Pré-Operatórios/efeitos adversos , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/estatística & dados numéricos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Arch Orthop Trauma Surg ; 140(4): 551-562, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31974697

RESUMO

INTRODUCTION: Pre-operative templating for total hip arthroplasty (THA) remains inaccurate due to improper magnification and alignment. We aimed to describe an improved templating strategy using computed tomography (CT) to predict component sizes and offsets with greater accuracy. MATERIALS AND METHODS: We analysed 184 CT images acquired for pre-operative templating of primary THA. We aimed to restore native (pre-arthritic) femoral offset and limb length, by raising the head center to the level of the templated cup center cranio-caudally, but maintaining the pathologic (pre-operative) head center medio-laterally (except in medialized hips). Acetabular offset (AO) and femoral offset (FO) were measured on pre-operative CT scans, during acetate templating, and on post-operative true antero-posterior radiographs. RESULTS: The post-operative offsets were within ± 5 mm from templated estimates in 174 hips (91%) for AO, in 116 hips (61%) for FO, in 111 hips (58%) for GO, and in 134 hips (70%) for neck cut level. The post-operative hip architecture reproduced the templated hip architecture within ±5 mm in 77 hips (40%). The agreement between planned and post-operative parameters was moderate for stem size (0.57), cup size (0.62), AO (0.50), but fair for FO (0.45). The AO decreased in most arthritic types, notably in lateralized hips (6.6 mm), but remained unchanged in medialized hips. The FO increased in most arthritic types (1.8-3.1 mm) but remained unchanged in medialized and lateralized hips. CONCLUSIONS: We described a strategy for pre-operative templating in THA. Despite the accuracy of CT, the authors found significant variations between planned and post-operative reconstructions, which suggest that pre-operative templating should only be used as an approximate guide.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril , Cuidados Pré-Operatórios/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/patologia , Acetábulo/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/patologia , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia , Humanos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA