Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 229
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 386(9): 827-836, 2022 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-35235725

RESUMO

BACKGROUND: Consensus recommendations regarding the threshold levels of cardiac troponin elevations for the definition of perioperative myocardial infarction and clinically important periprocedural myocardial injury in patients undergoing cardiac surgery range widely (from >10 times to ≥70 times the upper reference limit for the assay). Limited evidence is available to support these recommendations. METHODS: We undertook an international prospective cohort study involving patients 18 years of age or older who underwent cardiac surgery. High-sensitivity cardiac troponin I measurements (upper reference limit, 26 ng per liter) were obtained 3 to 12 hours after surgery and on days 1, 2, and 3 after surgery. We performed Cox analyses using a regression spline that explored the relationship between peak troponin measurements and 30-day mortality, adjusting for scores on the European System for Cardiac Operative Risk Evaluation II (which estimates the risk of death after cardiac surgery on the basis of 18 variables, including age and sex). RESULTS: Of 13,862 patients included in the study, 296 (2.1%) died within 30 days after surgery. Among patients who underwent isolated coronary-artery bypass grafting or aortic-valve replacement or repair, the threshold troponin level, measured within 1 day after surgery, that was associated with an adjusted hazard ratio of more than 1.00 for death within 30 days was 5670 ng per liter (95% confidence interval [CI], 1045 to 8260), a level 218 times the upper reference limit. Among patients who underwent other cardiac surgery, the corresponding threshold troponin level was 12,981 ng per liter (95% CI, 2673 to 16,591), a level 499 times the upper reference limit. CONCLUSIONS: The levels of high-sensitivity troponin I after cardiac surgery that were associated with an increased risk of death within 30 days were substantially higher than levels currently recommended to define clinically important periprocedural myocardial injury. (Funded by the Canadian Institutes of Health Research and others; VISION Cardiac Surgery ClinicalTrials.gov number, NCT01842568.).


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Infarto do Miocárdio/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Troponina I/sangue , Idoso , Valva Aórtica/cirurgia , Biomarcadores/sangue , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ponte de Artéria Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Valores de Referência
2.
Clin Chem ; 69(5): 492-499, 2023 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-36762424

RESUMO

BACKGROUND: Myocardial injury after non-cardiac surgery (MINS), based on measurement of troponin T, is associated with perioperative major adverse cardiovascular events (MACE). We therefore determined the high-sensitivity troponin I (hsTnI) thresholds associated with 30 day MACE after non-cardiac surgery. METHODS: We performed a nested biobank cohort study of 4553 patients from the Vascular Events in Non-Cardiac Surgery Patients Cohort Evaluation (VISION) Study. We measured hsTnI (ADVIA Centaur® hsTnI assay) on postoperative days 1 to 3 in patients ≥45 years undergoing non-cardiac surgery. An iterative Cox proportional hazard model determined peak postoperative hsTnI thresholds independently associated with MACE (i.e., death, myocardial infarction occurring on postoperative day 4 or after, non-fatal cardiac arrest, or congestive heart failure) within 30 days after surgery. RESULTS: MACE occurred in 89/4545 (2.0%) patients. Peak hsTnI values of <75 ng/L, 75 ng/L to <1000 ng/L, and ≥1000 ng/L were associated with 1.2% (95% CI, 0.9-1.6), 7.1% (95% CI, 4.8-10.5), and 25.9% (95% CI, 16.3-38.4) MACE, respectively. Compared to peak hsTnI <75 ng/L, values 75 ng/L to <1000 ng/L and ≥1000 ng/L were associated with adjusted hazard ratios (aHR) of 4.53 (95% CI, 2.75-7.48) and 16.17 (95% CI, 8.70-30.07), respectively. MACE was observed in 9% of patients with peak hsTnI ≥75 ng/L vs 1% in patients with peak hsTnI <75 ng/L (aHR 5.76; 95% CI, 3.64-9.11). A peak hsTnI ≥75 ng/L was associated with MACE in the presence (aHR 9.35; 95% CI, 5.28-16.55) or absence (aHR 3.99; 95% CI, 2.19-7.25) of ischemic features of myocardial injury. CONCLUSION: A peak postoperative hsTnI ≥75 ng/L was associated with >5-fold increase in the risk of 30 days MACE compared to levels <75 ng/L. This threshold could be used for MINS diagnosis when the ADVIA Centaur hsTnI assay is used.Clinicaltrials.gov Registration Number: NCT00512109.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Troponina I , Estudos de Coortes , Biomarcadores , Infarto do Miocárdio/diagnóstico
3.
Anesthesiology ; 138(5): 508-522, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37039711

RESUMO

BACKGROUND: The association between growth differentiation factor-15 concentrations and cardiovascular disease has been well described. The study hypothesis was that growth differentiation factor-15 may help cardiac risk stratification in noncardiac surgical patients, in addition to clinical evaluation. METHODS: The objective of the study was to determine whether preoperative serum growth differentiation factor-15 is associated with the composite primary outcome of myocardial injury after noncardiac surgery and vascular death at 30 days and can improve cardiac risk prediction in noncardiac surgery. This is a prospective cohort study of patients 45 yr or older having major noncardiac surgery. The association between preoperative growth differentiation factor-15 and the primary outcome was determined after adjusting for the Revised Cardiac Risk Index. Preoperative N-terminal-pro hormone brain natriuretic peptide was also added to compare predictive performance with growth differentiation factor-15. RESULTS: Between October 27, 2008, and October 30, 2013, a total of 5,238 patients were included who had preoperative growth differentiation factor-15 measured (median, 1,325; interquartile range, 880 to 2,132 pg/ml). The risk of myocardial injury after noncardiac surgery and vascular death was 99 of 1,705 (5.8%) for growth differentiation factor-15 less than 1,000 pg/ml, 161 of 1,332 (12.1%) for growth differentiation factor-15 1,000 to less than 1,500 pg/ml, 302 of 1476 (20.5%) for growth differentiation factor-15 1,500 to less than 3,000 pg/ml, and 247 of 725 (34.1%) for growth differentiation factor-15 concentrations 3,000 pg/ml or greater. Compared to patients who had growth differentiation factor-15 concentrations less than 1,000 pg/ml, the corresponding adjusted hazard ratio for each growth differentiation factor-15 category was 1.93 (95% CI, 1.50 to 2.48), 3.04 (95% CI, 2.41 to 3.84), and 4.8 (95% CI, 3.76 to 6.14), respectively. The addition of growth differentiation factor-15 improved cardiac risk classification by 30.1% (301 per 1,000 patients) compared to Revised Cardiac Risk Index alone. It also provided additional risk classification beyond the combination of preoperative N-terminal-pro hormone brain natriuretic peptide and Revised Cardiac Risk Index (16.1%; 161 per 1,000 patients). CONCLUSIONS: Growth differentiation factor-15 is strongly associated with 30-day risk of major cardiovascular events and significantly improved cardiac risk prediction in patients undergoing noncardiac surgery.


Assuntos
Doenças Cardiovasculares , Peptídeo Natriurético Encefálico , Humanos , Biomarcadores , Fatores de Diferenciação de Crescimento , Valor Preditivo dos Testes , Estudos Prospectivos , Pessoa de Meia-Idade
4.
Clin Chem Lab Med ; 61(7): 1335-1342, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36698327

RESUMO

OBJECTIVES: Confounding factors, including sex, age, and renal dysfunction, affect high-sensitivity cardiac troponin T (hs-cTnT) concentrations and the acute myocardial infarction (AMI) diagnosis. This study assessed the effects of these confounders through logistic regression models and evaluated the diagnostic performance of an optimized, integrated prediction model. METHODS: This retrospective study included a primary derivation cohort of 18,022 emergency department (ED) patients at a US medical center and a validation cohort of 890 ED patients at a Canadian medical center. Hs-cTnT was measured with 0/3 h sampling. The primary outcome was index AMI diagnosis. Logistic regression models were optimized to predict AMI using delta hs-cTnT and its confounders as covariates. The diagnostic performance of model cutoffs was compared to that of the hs-cTnT delta thresholds. Serial logistic regressions were carried out to evaluate the relationship between covariates. RESULTS: The area under the curve of the best-fitted model was 0.95. The model achieved a 90.0% diagnostic accuracy in the validation cohort. The optimal model cutoff yielded comparable performance (90.5% accuracy) to the optimal sex-specific delta thresholds (90.3% accuracy), with 95.8% agreement between the two diagnostic methods. Serial logistic regressions revealed that delta hs-cTnT played a more predominant role in AMI prediction than its confounders, among which sex is more predictive of AMI (total effect coefficient 1.04) than age (total effect coefficient 0.05) and eGFR (total effect coefficient -0.008). CONCLUSIONS: The integrated prediction model incorporating confounding factors does not outperform hs-cTnT delta thresholds. Sex-specific hs-cTnT delta thresholds remain to provide the highest diagnostic accuracy.


Assuntos
Infarto do Miocárdio , Troponina T , Masculino , Feminino , Humanos , Modelos Logísticos , Estudos Retrospectivos , Canadá , Infarto do Miocárdio/diagnóstico , Biomarcadores
5.
N Engl J Med ; 380(26): 2529-2540, 2019 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-31242362

RESUMO

BACKGROUND: Data regarding high-sensitivity troponin concentrations in patients presenting to the emergency department with symptoms suggestive of myocardial infarction may be useful in determining the probability of myocardial infarction and subsequent 30-day outcomes. METHODS: In 15 international cohorts of patients presenting to the emergency department with symptoms suggestive of myocardial infarction, we determined the concentrations of high-sensitivity troponin I or high-sensitivity troponin T at presentation and after early or late serial sampling. The diagnostic and prognostic performance of multiple high-sensitivity troponin cutoff combinations was assessed with the use of a derivation-validation design. A risk-assessment tool that was based on these data was developed to estimate the risk of index myocardial infarction and of subsequent myocardial infarction or death at 30 days. RESULTS: Among 22,651 patients (9604 in the derivation data set and 13,047 in the validation data set), the prevalence of myocardial infarction was 15.3%. Lower high-sensitivity troponin concentrations at presentation and smaller absolute changes during serial sampling were associated with a lower likelihood of myocardial infarction and a lower short-term risk of cardiovascular events. For example, high-sensitivity troponin I concentrations of less than 6 ng per liter and an absolute change of less than 4 ng per liter after 45 to 120 minutes (early serial sampling) resulted in a negative predictive value of 99.5% for myocardial infarction, with an associated 30-day risk of subsequent myocardial infarction or death of 0.2%; a total of 56.5% of the patients would be classified as being at low risk. These findings were confirmed in an external validation data set. CONCLUSIONS: A risk-assessment tool, which we developed to integrate the high-sensitivity troponin I or troponin T concentration at emergency department presentation, its dynamic change during serial sampling, and the time between the obtaining of samples, was used to estimate the probability of myocardial infarction on emergency department presentation and 30-day outcomes. (Funded by the German Center for Cardiovascular Research [DZHK]; ClinicalTrials.gov numbers, NCT00470587, NCT02355457, NCT01852123, NCT01994577, and NCT03227159; and Australian New Zealand Clinical Trials Registry numbers, ACTRN12611001069943, ACTRN12610000766011, ACTRN12613000745741, and ACTRN12611000206921.).


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Medição de Risco/métodos , Troponina/sangue , Adulto , Idoso , Biomarcadores/sangue , Estudos de Coortes , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Sensibilidade e Especificidade , Troponina I/sangue
6.
Clin Chem ; 68(3): 441-449, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-34871358

RESUMO

BACKGROUND: Sex differences in high-sensitivity cardiac troponin (hs-cTn) concentrations from healthy populations have led to the establishment of sex-specific upper reference limits for hs-cTn assays. This study assessed the performance of sex-specific delta (i.e., changes in concentrations) thresholds for the hs-cTnT assay for ruling in acute myocardial infarction (AMI) in different emergency department (ED) populations. METHODS: This retrospective study consisted of 2 cohorts (Cohort 1 derivation and Cohort 2 validation). Cohort 1 consisted of 18 056 ED patients who had serial hs-cTnT measured using a 0-h/3-h algorithm at a US medical center, with Cohort 2 consisting of 1137 ED patients with 0-h/3-h sampling at a Canadian medical center. The primary outcome was AMI diagnosis with sex-specific deltas derived based on the Youden index and specificity estimates (i.e., ≥90%) in Cohort 1 and validated in Cohort 2. RESULTS: In Cohort 1, 42% of all patients had 0-h hs-cTnT above the sex-specific 99th percentile. Males had higher 0-h hs-cTnT (median 17 ng/L) and absolute deltas (median 2 ng/L) than females (0-h median 11 ng/L, P < 0.0001; deltas median 1 ng/L, P < 0.0001) in non-AMI patients but not in patients with AMI. For ruling in AMI, the sex-specific delta thresholds based on 90% specificity (14 ng/L for males, 11 ng/L for females) performed best and resulted in 91% diagnostic accuracy in both males and females. The sex-specific delta thresholds yielding high specificity estimates were confirmed in the validation data set. CONCLUSIONS: Sex-specific absolute delta thresholds can be used to rule in AMI and are robust across different study populations.


Assuntos
Infarto do Miocárdio , Troponina T , Biomarcadores , Canadá , Feminino , Humanos , Masculino , Infarto do Miocárdio/diagnóstico , Estudos Retrospectivos
7.
Clin Chem ; 67(1): 107-113, 2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33045044

RESUMO

BACKGROUND: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that emerged late in 2019 causing COVID-19 (coronavirus disease-2019) may adversely affect the cardiovascular system. Publications from Asia, Europe, and North America have identified cardiac troponin as an important prognostic indicator for patients hospitalized with COVID-19. We recognized from publications within the first 6 months of the pandemic that there has been much uncertainty on the reporting, interpretation, and pathophysiology of an increased cardiac troponin concentration in this setting. CONTENT: The purpose of this mini-review is: a) to review the pathophysiology of SARS-CoV-2 and the cardiovascular system, b) to overview the strengths and weaknesses of selected studies evaluating cardiac troponin in patients with COVID-19, and c) to recommend testing strategies in the acute period, in the convalescence period and in long-term care for patients who have become ill with COVID-19. SUMMARY: This review provides important educational information and identifies gaps in understanding the role of cardiac troponin and COVID-19. Future, properly designed studies will hopefully provide the much-needed evidence on the path forward in testing cardiac troponin in patients with COVID-19.


Assuntos
COVID-19/sangue , Troponina/sangue , Biomarcadores/sangue , COVID-19/complicações , COVID-19/epidemiologia , COVID-19/virologia , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/diagnóstico , Humanos , Pandemias , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
8.
Clin Chem Lab Med ; 59(8): 1431-1443, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33761581

RESUMO

OBJECTIVES: This study compared the independent and combined effects of hemolysis and biotin on cardiac troponin measurements across nine high-sensitivity cardiac troponin (hs-cTn) assays. METHODS: Parallel cTn measurements were made in pooled lithium heparin plasma spiked with hemolysate and/or biotin using nine hs-cTn assays: Abbott Alinity, Abbott ARCHITECT i2000, Beckman Access 2, Ortho VITROS XT 7600, Siemens Atellica, Siemens Centaur, Siemens Dimension EXL cTnI, and two Roche Cobas e 411 Elecsys Troponin T-hs cTnT assays (outside US versions, with and without increased biotin tolerance). Absolute and percent cTn recovery relative to two baseline concentrations were determined in spiked samples and compared to manufacturer's claims. RESULTS: All assays except the Ortho VITROS XT 7600 showed hemolysis and biotin interference thresholds equivalent to or greater than manufacturer's claims. While imprecision confounded analysis of Ortho VITROS XT 7600 data, evidence of biotin interference was lacking. Increasing biotin concentration led to decreasing cTn recovery in three assays, specifically both Roche Cobas e 411 Elecsys Troponin T-hs assays and the Siemens Dimension EXL. While one of the Roche assays was the most susceptible to biotin among the nine studied, a new version showed reduced biotin interference by approximately 100-fold compared to its predecessor. Increasing hemolysis also generally led to decreasing cTn recovery for susceptible assays, specifically the Beckman Access 2, Ortho VITROS XT 7600, and both Roche Cobas e 411 Elecsys assays. Equivalent biotin and hemolysis interference thresholds were observed at the two cTn concentrations considered for all but two assays (Beckman Access 2 and Ortho VITROS XT 7600). When biotin and hemolysis were present in combination, biotin interference thresholds decreased with increasing hemolysis for two susceptible assays (Roche Cobas e 411 Elecsys and Siemens Dimension EXL). CONCLUSIONS: Both Roche Cobas e 411 Elecsys as well as Ortho VITROS XT assays were susceptible to interference from in vitro hemolysis at levels routinely encountered in clinical laboratory samples (0-3 g/L free hemoglobin), leading to falsely low cTn recovery up to 3 ng/L or 13%. While most assays are not susceptible to biotin at levels expected with over-the-counter supplementation, severely reduced cTn recovery is possible at biotin levels of 10-2000 ng/mL (41-8,180 nmol/L) for some assays. Due to potential additive effects, analytical interferences should not be considered in isolation.


Assuntos
Hemólise , Biotina , Humanos , Laboratórios Clínicos , Troponina I , Troponina T
9.
Clin Chem Lab Med ; 59(4): 749-755, 2021 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-33079697

RESUMO

OBJECTIVES: To analytically evaluate Ortho Clinical Diagnostics VITROS high-sensitivity cardiac troponin I (hs-cTnI) assay in specific matrices with comparison to other hs-cTn assays. METHODS: The limit of detection (LoD), imprecision, interference and stability testing for both serum and lithium heparin (Li-Hep) plasma for the VITROS hs-cTnI assay was determined. We performed Passing-Bablok regression analyses between sample types for the VITROS hs-cTnI assay and compared them to the Abbott ARCHITECT, Beckman Access and the Siemens ADVIA Centaur hs-cTnI assays. We also performed Receiver-operating characteristic curve analyses with the area under the curve (AUC) determined in an emergency department (ED)-study population (n=131) for myocardial infarction (MI). RESULTS: The VITROS hs-cTnI LoD was 0.73 ng/L (serum) and 1.4 ng/L (Li-Hep). Stability up to five freeze-thaws was observed for the Ortho hs-cTnI assay, with the analyte stability at room temperature in serum superior to Li-Hep with gross hemolysis also affecting Li-Hep plasma hs-cTnI results. Comparison of Li-Hep to serum concentrations (n=202), yielded proportionally lower concentrations in plasma with the VITROS hs-cTnI assay (slope=0.85; 95% confidence interval [CI]:0.83-0.88). In serum, the VITROS hs-cTnI concentrations were proportionally lower compared to other hs-cTnI assays, with similar slopes observed between assays in samples frozen <-70 °C for 17 years (ED-study) or in 2020. In the ED-study, the VITROS hs-cTnI assay had an AUC of 0.974 (95%CI:0.929-0.994) for MI, similar to the AUCs of other hs-cTn assays. CONCLUSIONS: Lack of standardization of hs-cTnI assays across manufacturers is evident. The VITROS hs-cTnI assay yields lower concentrations compared to other hs-cTnI assays. Important differences exist between Li-Hep plasma and serum, with evidence of stability and excellent clinical performance comparable to other hs-cTn assays.


Assuntos
Bioensaio , Infarto do Miocárdio , Troponina I , Heparina , Humanos , Limite de Detecção , Infarto do Miocárdio/diagnóstico , Curva ROC
10.
Br J Anaesth ; 126(1): 172-180, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32718723

RESUMO

BACKGROUND: Diagnostic criteria for Bleeding Independently associated with Mortality after noncardiac Surgery (BIMS) have been defined as bleeding that leads to a postoperative haemoglobin <70 g L-1, leads to blood transfusion, or is judged to be the direct cause of death. Preoperative prediction guides for BIMS can facilitate informed consent and planning of perioperative care. METHODS: In a prospective cohort study of 16 079 participants aged ≥45 yr having inpatient noncardiac surgery at 12 academic hospitals in eight countries between 2007 and 2011, 17.3% (2782) experienced BIMS. An electronic risk calculator for BIMS was developed and internally validated by logistic regression with bootstrapping, and further simplified to a risk index. Decision curve analysis assessed the potential utility of each prediction guide compared with a strategy of identifying risk of BIMS based on preoperative haemoglobin <120 g L-1. RESULTS: With information about the type of surgery, preoperative haemoglobin, age, sex, functional status, kidney function, history of high-risk coronary artery disease, and active cancer, the risk calculator accurately predicted BIMS (bias-corrected C-statistic, 0.84; 95% confidence interval, 0.837-0.852). A simplified index based on preoperative haemoglobin <120 g L-1, open surgery, and high-risk surgery also predicted BIMS, but less accurately (C-statistic, 0.787; 95% confidence interval, 0.779-0.796). Both prediction guides could improve decision making compared with knowledge of haemoglobin <120 g L-1 alone. CONCLUSIONS: BIMS, defined as bleeding that leads to a postoperative haemoglobin <70 g L-1, leads to blood transfusion, or that is judged to be the direct cause of death, can be predicted by a simple risk index before surgery. CLINICAL TRIAL REGISTRATION: NCT00512109.


Assuntos
Transfusão de Sangue , Hemorragia , Humanos , Modelos Logísticos , Prognóstico , Estudos Prospectivos
11.
Br J Anaesth ; 126(1): 163-171, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32768179

RESUMO

BACKGROUND: We aimed to establish diagnostic criteria for bleeding independently associated with mortality after noncardiac surgery (BIMS) defined as bleeding during or within 30 days after noncardiac surgery that is independently associated with mortality within 30 days of surgery, and to estimate the proportion of 30-day postoperative mortality potentially attributable to BIMS. METHODS: This was a prospective cohort study of participants ≥45 yr old having inpatient noncardiac surgery at 12 academic hospitals in eight countries between 2007 and 2011. Cox proportional hazards models evaluated the adjusted relationship between candidate diagnostic criteria for BIMS and all-cause mortality within 30 days of surgery. RESULTS: Of 16 079 participants, 2.0% (315) died and 36.1% (5810) met predefined screening criteria for bleeding. Based on independent association with 30-day mortality, BIMS was identified as bleeding leading to a postoperative haemoglobin <70 g L-1, transfusion of ≥1 unit of red blood cells, or that was judged to be the cause of death. Bleeding independently associated with mortality after noncardiac surgery occurred in 17.3% of patients (2782). Death occurred in 5.8% of patients with BIMS (161/2782), 1.3% (39/3028) who met bleeding screening criteria but not BIMS criteria, and 1.1% (115/10 269) without bleeding. BIMS was associated with mortality (adjusted hazard ratio: 1.87; 95% confidence interval: 1.42-2.47). We estimated the proportion of 30-day postoperative deaths potentially attributable to BIMS to be 20.1-31.9%. CONCLUSIONS: Bleeding independently associated with mortality after noncardiac surgery (BIMS), defined as bleeding that leads to a postoperative haemoglobin <70 g L-1, blood transfusion, or that is judged to be the cause of death, is common and may account for a quarter of deaths after noncardiac surgery. CLINICAL TRIAL REGISTRATION: NCT00512109.


Assuntos
Hemorragia Pós-Operatória/diagnóstico , Hemorragia Pós-Operatória/mortalidade , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
12.
Ann Intern Med ; 172(2): 96-104, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31869834

RESUMO

Background: Preliminary data suggest that preoperative N-terminal pro-B-type natriuretic peptide (NT-proBNP) may improve risk prediction in patients undergoing noncardiac surgery. Objective: To determine whether preoperative NT-proBNP has additional predictive value beyond a clinical risk score for the composite of vascular death and myocardial injury after noncardiac surgery (MINS) within 30 days after surgery. Design: Prospective cohort study. Setting: 16 hospitals in 9 countries. Patients: 10 402 patients aged 45 years or older having inpatient noncardiac surgery. Measurements: All patients had NT-proBNP levels measured before surgery and troponin T levels measured daily for up to 3 days after surgery. Results: In multivariable analyses, compared with preoperative NT-proBNP values less than 100 pg/mL (the reference group), those of 100 to less than 200 pg/mL, 200 to less than 1500 pg/mL, and 1500 pg/mL or greater were associated with adjusted hazard ratios of 2.27 (95% CI, 1.90 to 2.70), 3.63 (CI, 3.13 to 4.21), and 5.82 (CI, 4.81 to 7.05) and corresponding incidences of the primary outcome of 12.3% (226 of 1843), 20.8% (542 of 2608), and 37.5% (223 of 595), respectively. Adding NT-proBNP thresholds to clinical stratification (that is, the Revised Cardiac Risk Index [RCRI]) resulted in a net absolute reclassification improvement of 258 per 1000 patients. Preoperative NT-proBNP values were also statistically significantly associated with 30-day all-cause mortality (less than 100 pg/mL [incidence, 0.3%], 100 to less than 200 pg/mL [incidence, 0.7%], 200 to less than 1500 pg/mL [incidence, 1.4%], and 1500 pg/mL or greater [incidence, 4.0%]). Limitation: External validation of the identified NT-proBNP thresholds in other cohorts would reinforce our findings. Conclusion: Preoperative NT-proBNP is strongly associated with vascular death and MINS within 30 days after noncardiac surgery and improves cardiac risk prediction in addition to the RCRI. Primary Funding Source: Canadian Institutes of Health Research.


Assuntos
Biomarcadores/sangue , Doenças Cardiovasculares/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Complicações Pós-Operatórias/sangue , Procedimentos Cirúrgicos Operatórios , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Período Pré-Operatório , Estudos Prospectivos , Troponina T/sangue
13.
Am Heart J ; 221: 84-94, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31954328

RESUMO

BACKGROUND: High-sensitivity cardiac troponin (hs-cTn) assays enhance detection of lower circulating troponin concentrations, but the impact on outcomes in clinical practice is unclear. Our objective was to compare outcomes of chest pain patients discharged from emergency departments (EDs) using hs-cTn and conventional troponin (cTn) assays. METHODS: We conducted an observational study of chest pain patients aged 40-105 years who presented to an ED from April 1, 2013, to March 31, 2017, and were discharged home. We compared 30-day and 1-year outcomes of EDs that used hs-cTn versus cTn assays. The primary outcome was a composite of all-cause death, myocardial infarction or unstable angina. Comparisons were conducted with (1) no adjustment; (2) adjustment for demographic, socioeconomic, and hospital characteristics; and (3) full clinical adjustment. RESULTS: Among the 394,910 patients, 62,138 (15.7%) were evaluated at hs-cTn EDs and 332,772 (84.3%) were evaluated at cTn EDs. Patients discharged from hs-cTn EDs were less likely to have diabetes, hypertension, or prior heart disease. At 30 days, the unadjusted primary outcome rate was lower in hs-cTn EDs (0.9% vs 1.0%, P < .001). The 30-day hazard ratios for the primary outcome were 0.84 (95% CI 0.77-0.92) for no adjustment and 0.98 (95% CI 0.88-1.08) for full adjustment. Over 1 year, patients discharged from hs-cTn EDs had significantly fewer primary outcomes (3.7% vs 4.1%, P < .001) and lower hazard ratio (0.93; 95% CI 0.89-0.98) even after full adjustment. CONCLUSIONS: Hs-cTn testing was associated with a significantly lower adjusted hazard of myocardial infarction, angina, and all-cause hospitalization at 1 year but not 30 days.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Angina Instável/epidemiologia , Dor no Peito/etiologia , Técnicas de Laboratório Clínico/métodos , Mortalidade , Infarto do Miocárdio/epidemiologia , Troponina I/análise , Troponina T/análise , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Serviço Hospitalar de Emergência , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Alta do Paciente , Modelos de Riscos Proporcionais , Troponina I/metabolismo , Troponina T/metabolismo
14.
Am Heart J ; 229: 18-28, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32916606

RESUMO

Despite evidence that high-sensitivity cardiac troponin (hs-cTn) levels in women are lower than in men, a single threshold based on the 99th percentile upper reference limit of the overall reference population is commonly used to diagnose myocardial infarction in clinical practice. This trial aims to determine whether the use of a lower female-specific hs-cTn threshold would improve the diagnosis, treatment, and outcomes of women presenting to the emergency department with symptoms suggestive of myocardial ischemia. METHODS/DESIGN: CODE-MI (hs-cTn-Optimizing the Diagnosis of Acute Myocardial Infarction/Injury in Women) is a multicenter, stepped-wedge, cluster-randomized trial of 30 secondary and tertiary care hospitals across 8 Canadian provinces, with the unit of randomization being the hospital. All adults (≥20 years of age) presenting to the emergency department with symptoms suggestive of myocardial ischemia and at least 1 hs-cTn test are eligible for inclusion. Over five, 5-month intervals, hospitals will be randomized to implement lower female hs-cTn thresholds according to the assay being used at each site. Men will continue to be assessed using the overall thresholds throughout. Women with a peak hs-cTn value between the female-specific and the overall thresholds will form our primary cohort. The primary outcome, a 1-year composite of all-cause mortality or readmission for nonfatal myocardial infarction, incident heart failure, or emergent/urgent coronary revascularization, will be compared before and after the implementation of female thresholds using mixed-effects logistic regression models. The cohort and outcomes will be obtained from routinely collected administrative data. The trial is designed to detect a 20% relative risk difference in the primary outcome, or a 2.2% absolute difference, with 82% power. CONCLUSIONS: This pragmatic trial will assess whether adopting lower female hs-cTn thresholds leads to appropriate assessment of women with symptoms suggestive of myocardial infarction, thereby improving treatment and outcomes.


Assuntos
Infarto do Miocárdio , Padrões de Prática Médica/normas , Medição de Risco/métodos , Fatores Sexuais , Adulto , Diagnóstico Diferencial , Precisão da Medição Dimensional , Feminino , Humanos , Masculino , Estudos Multicêntricos como Assunto , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Ensaios Clínicos Pragmáticos como Assunto , Valor Preditivo dos Testes , Melhoria de Qualidade , Troponina I/sangue
16.
Clin Chem ; 65(10): 1221-1227, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31387884

RESUMO

The IFCC Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has directives and initiatives focused on providing evidence-based educational resources to aid and improve understanding around key analytical and clinical aspects of cardiac biomarkers used in clinical practice and the research setting. As a task force, we have previously published position statements and recommendations focused on use and analytical aspects of high-sensitivity cardiac troponin assays. The current educational document is the first from the C-CB highlighting important biochemical, analytical, and clinical aspects as they relate to the natriuretic peptides (NPs), including B-type natriuretic peptide (BNP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP), with a focus on heart failure.


Assuntos
Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Peptídeo Natriurético Encefálico/sangue , Humanos , Imunoensaio/métodos , Fragmentos de Peptídeos/sangue
17.
Clin Chem Lab Med ; 57(5): 745-751, 2019 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-30838842

RESUMO

Background Manufacturers of high-sensitivity cardiac troponin (hs-cTn) assays have restricted use of what sample types or matrices are acceptable to use for measurement. Our goal was to evaluate the comparability of the Siemens ADVIA Centaur hs-cTnI assay across different matrices and under different storage conditions. Methods Three different QC-plasma matrices were evaluated for imprecision <10 ng/L. Passing-Bablok regression and difference plots were determined for cTnI concentrations spanning the reference interval (limit of quantification to male 99th-percentile: 2.5 ng/L to <60 ng/L) between serum and lithium heparin plasma, lithium heparin and EDTA plasma and between the Siemens and Abbott hs-cTnI assays. Stability at room temperature (RT) and 2-8 °C was also assessed across the three matrices. Results Over 16-weeks the SDs were ≤1.0 ng/L for QCs ranging from 5.0 to 8.3 ng/L. Across the reference interval there was excellent agreement between lithium heparin plasma and serum for the Siemens hs-cTnI assay (slope=0.98/intercept=-0.1), however, cTnI concentrations were proportionally lower in EDTA as compared to lithium heparin plasma (slope=0.90, 95% CI: 0.88-0.92). In lithium heparin plasma the Siemens hs-cTnI concentrations were higher than the Abbott hs-cTnI concentrations (slope=1.26/intercept=-0.2). Stability of cTnI in lithium heparin plasma as compared in serum and EDTA plasma appeared more labile, with decreases ≥20% in concentrations evident as early as 1-day in storage at RT. Conclusions There is excellent agreement in concentrations between lithium heparin plasma and serum with the Siemens ADVIA Centaur hs-cTnI assay; however, cTnI concentrations in EDTA plasma are lower. Reference intervals and clinical studies in EDTA plasma for the Centaur hs-cTnI assay are required before clinical use.


Assuntos
Troponina I/sangue , Análise Química do Sangue/normas , Coleta de Amostras Sanguíneas , Ácido Edético/química , Heparina/química , Humanos , Imunoensaio/normas , Controle de Qualidade , Valores de Referência
18.
Clin Chem Lab Med ; 57(5): 633-640, 2019 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-30291783

RESUMO

Two interferences recently brought to the forefront as patient safety issues include hemolysis (hemoglobin) and biotin (vitamin B7). The International Federation for Clinical Chemistry Committee on Cardiac Biomarkers (IFCC-CB) obtained input from a majority of cTn and NP assay manufacturers to collate information related to high-sensitivity (hs)-cTnI, hs-cTnT, contemporary, and POC cTn assays, and NP assays interferences due to hemolysis and biotin. The information contained in these tables was designed as educational tools to aid laboratory professionals and clinicians in troubleshooting cardiac biomarker analytical results that are discordant with the clinical situation.


Assuntos
Análise Química do Sangue/estatística & dados numéricos , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Troponina I/sangue , Troponina T/sangue , Biomarcadores/sangue , Biotina/sangue , Hemólise/fisiologia , Humanos
19.
Clin Chem ; 64(4): 645-655, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29343532

RESUMO

This document is an essential companion to the third iteration of the National Academy of Clinical Biochemistry [NACB,8 now the American Association for Clinical Chemistry (AACC) Academy] Laboratory Medicine Practice Guidelines (LMPG) on cardiac markers. The expert consensus recommendations were drafted in collaboration with the International Federation of Clinical Chemistry and Laboratory Medicine Task Force on Clinical Applications of Bio-Markers (IFCC TF-CB). We determined that there is sufficient clinical guidance on the use of cardiac troponin (cTn) testing from clinical practice groups. Thus, in this expert consensus document, we focused on clinical laboratory practice recommendations for high-sensitivity (hs)-cTn assays. This document utilized the expert opinion class of evidence to focus on the following 10 topics: (a) quality control (QC) utilization, (b) validation of the lower reportable analytical limits, (c) units to be used in reporting measurable concentrations for patients and QC materials, (d) 99th percentile sex-specific upper reference limits to define the reference interval; (e) criteria required to define hs-cTn assays, (f) communication with clinicians and the laboratory's role in educating clinicians regarding the influence of preanalytic and analytic problems that can confound assay results, (g) studies on hs-cTn assays and how authors need to document preanalytical and analytical variables, (h) harmonizing and standardizing assay results and the role of commutable materials, (i) time to reporting of results from sample receipt and sample collection, and (j) changes in hs-cTn concentrations over time and the role of both analytical and biological variabilities in interpreting results of serial blood collections.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Testes de Química Clínica , Troponina I/sangue , Troponina T/sangue , Biomarcadores/sangue , Serviços de Laboratório Clínico , Humanos , Internacionalidade , Controle de Qualidade , Padrões de Referência
20.
CMAJ ; 190(33): E974-E984, 2018 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-30127037

RESUMO

BACKGROUND: Testing for high-sensitivity cardiac troponin (hs-cTn) may assist triage and clinical decision-making in patients presenting to the emergency department with symptoms of acute coronary syndrome; however, this could result in the misclassification of risk because of analytical variation or laboratory error. We sought to evaluate a new laboratory-based risk-stratification tool that incorporates tests for hs-cTn, glucose level and estimated glomerular filtration rate to identify patients at risk of myocardial infarction or death when presenting to the emergency department. METHODS: We constructed the clinical chemistry score (CCS) (range 0-5 points) and validated it as a predictor of 30-day myocardial infarction (MI) or death using data from 4 cohort studies involving patients who presented to the emergency department with symptoms suggestive of acute coronary syndrome. We calculated diagnostic parameters for the CCS score separately using high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT). RESULTS: For the combined cohorts (n = 4245), 17.1% of participants had an MI or died within 30 days. A CCS score of 0 points best identified low-risk participants: the hs-cTnI CCS had a sensitivity of 100% (95% confidence interval [CI] 99.5%-100%), with 8.9% (95% CI 8.1%-9.8%) of the population classified as being at low risk of MI or death within 30 days; the hs-cTnT CCS had a sensitivity of 99.9% (95% CI 99.2%-100%), with 10.5% (95% CI 9.6%-11.4%) of the population classified as being at low risk. The CCS had better sensitivity than hs-cTn alone (hs-cTnI < 5 ng/L: 96.6%, 95% CI 95.0%-97.8%; hs-cTnT < 6 ng/L: 98.2%, 95% CI 97.0%-99.0%). A CCS score of 5 points best identified patients at high risk (hs-cTnI CCS: specificity 96.6%, 95% CI 96.0%-97.2%; 11.2% [95% CI 10.3%-12.2%] of the population classified as being at high risk; hs-cTnT CCS: specificity 94.0%, 95% CI 93.1%-94.7%; 13.1% [95% CI 12.1%-14.1%] of the population classified as being at high risk) compared with using the overall 99th percentiles for the hs-cTn assays (specificity of hs-cTnI 93.2%, 95% CI 92.3-94.0; specificity of hs-cTnT 73.8%, 95% CI 72.3-75.2). INTERPRETATION: The CCS score at the chosen cut-offs was more sensitive and specific than hs-cTn alone for risk stratification of patients presenting to the emergency department with suspected acute coronary syndrome. Study registration: ClinicalTrials.gov, nos. NCT01994577; NCT02355457.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Técnicas de Laboratório Clínico , Miocárdio/química , Troponina I/análise , Troponina T/análise , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Glicemia/análise , Morte , Serviço Hospitalar de Emergência , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA