Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Pacing Clin Electrophysiol ; 44(12): 1963-1971, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34586643

RESUMO

BACKGROUND: Optimization of cardiac resynchronization therapy (CRT) is often time-consuming and therefore underused in a clinical setting. Novel device-based algorithms aiming to simplify optimization include a dynamic atrioventricular delay (AVD) algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott). This study examines the acute effect of SyncAV and MPP on electrical synchrony in patients with newly and chronically implanted CRT devices. METHODS: Patients with SyncAV and MPP enabled devices were prospectively enrolled during implant or scheduled follow-up. Blinded 12-lead electrocardiographic acute measurements of QRS duration (QRSd) were performed for intrinsic QRSd (Intrinsic), bi-ventricular pacing (BiV), MPP, BiV with SyncAV at default offset 50 ms (BiVSyncAVdef ), BiV with SyncAV at patient-specific optimised offset (BiVSyncAVopt ), MPP with SyncAV at default offset 50 ms (MPPSyncAVdef ), and MPP with SyncAV at patient-specific optimised offset (MPPSyncAVopt ). RESULTS: Thirty-three patients were enrolled. QRSd for Intrinsic, BiV, MPP, BiVSyncAVdef , BiVSyncAVopt , MPPSyncAVdef , MPPSyncAVopt were 160.4 ± 20.6 ms, 141.0 ± 20.5 ms, 130.2 ± 17.2 ms, 121.7 ± 20.9 ms, 117.0 ± 19.0 ms, 121.2 ± 17.1 ms, 108.7 ± 16.5 ms respectively. MPPSyncAVopt led to greatest reduction of QRSd relative to Intrinsic (-31.6 ± 11.1%; p < .001), showed significantly shorter QRSd compared to all other pacing configurations (p < .001) and shortest QRSd in every patient. Shortening of QRSd was not significantly different between newly and chronically implanted devices (-51.6 ± 14.7 ms vs. -52.7 ± 21.9 ms; p = .99). CONCLUSION: SyncAV and MPP improved acute electrical synchrony in CRT. Combining both technologies with patient-specific optimization resulted in greatest improvement, regardless of time since implantation. Whats new Novel device-based algorithms like a dynamic AVD algorithm (SyncAV, Abbott) and multipoint pacing (MPP, Abbott) aim to simplify CRT optimization. Our data show that a combination of patient tailored SyncAV optimization and MPP results in greatest improvement of electrical synchrony in CRT measured by QRS duration, regardless if programmed in newly or chronically implanted devices. This is the first study to our knowledge to examine a combination of these device-based algorithms. The results help understanding the ideal ventricular excitation in heart failure.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/terapia , Idoso , Eletrocardiografia , Feminino , Alemanha , Humanos , Masculino , Estudos Prospectivos
3.
Herz ; 46(Suppl 2): 222-227, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33026482

RESUMO

BACKGROUND: The prevalence of aortic valve stenosis is increasing due to the continuously growing geriatric population. Data on procedural success and mortality of very old patients are sparse, raising the question of when this population may be deemed as "too old even for transcatheter aortic valve replacement (TAVR)." We, therefore, sought to evaluate the influence of age on outcome after TAVR and the impact of direct implantation. METHODS: The data of 394 consecutive patients undergoing TF-TAVR were analyzed. Patients were divided into four age groups: ≤75 (group 1, n = 28), 76-80 (group 2, n = 107), 81-85 (group 3, n = 148), and >85 (group 4, n = 111) years. Direct implantation was performed when possible according to current recommendations. Survival was evaluated by Kaplan-Meier analysis. RESULTS: Mortality at 30 days and 1 year was not significantly different between the four age groups (3.6 vs. 6.7 vs. 5.4 vs. 2.7% and 7.6 vs. 17 vs. 14.5 vs. 13%m respectively, log-rank p = 0.59). Direct implantation without balloon aortic valvuloplasty was more frequently performed on patients aged >85 vs. ≤85 years (33.3 vs. 14.1%, p < 0.001). the incidence of procedural complications frequently associated with advanced age (stroke, vascular complications) was not significantly increased in group 4. CONCLUSION: Outcome after TF-TAVR is comparable among different age cohorts, even in very old patients. Direct implantation simplifies the procedure and could therefore play a role in reducing the incidence of peri-interventional complications in patients of advanced age.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Fatores de Risco , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 31(5): 1147-1154, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32162757

RESUMO

INTRODUCTION: The Medtronic Attain Stability Quad lead is a quadripolar left ventricular (LV) lead with an active fixation helix assembly designed to fixate the lead within the coronary sinus and pace nonapical regions of the LV. The primary objective of this study was to determine the safety and effectiveness of this novel active fixation quadripolar LV lead. METHODS: Patients with standard indications for cardiac resynchronization therapy (CRT) were enrolled. All patients were followed at 3 and 6 months post-implant and every 6 months thereafter until study closure. Pacing capture thresholds (PCTs) were measured at implant and each follow-up and adverse events (AEs) were recorded upon occurrence. RESULTS: Of the 440 patients who underwent implant procedures, placement of the Attain Stability Quad lead was successful in 426 (96.8%). LV lead-related complications occurred in 10 patients (2.3%), including LV lead dislodgement in three patients (0.7%). The percentage of patients with at least one LV pacing vector with a PCT ≤2.5 V at a 6-month follow-up was 96.3%. The LV lead was successfully fixated to the prespecified pacing location in 97.4% of cases. CONCLUSIONS: This large, multinational study of the Attain Stability Quad lead demonstrated a high rate of implant success with a low complication rate. The active fixation mechanism allowed precise placement of the pacing electrodes at the desired target region with good PCTs and a very low dislodgement rate.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Rev Cardiovasc Med ; 18(1): 1-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28509888

RESUMO

This article provides a technical description of common implant practice for delivery of cardiac contractility modulation (CCM) therapy to heart failure patients. As of September 2016, the authors of this article collectively have been involved with more than 400 system implantations in five medical centers, beginning with the advent of CCM therapy approximately 12 years ago. CCM therapy has been evaluated in a variety of studies, and was shown to be safe and effective and of benefit to patient quality of life and exercise capacity. As the use of CCM therapy continuously expands among medical centers in Europe, this article describes the technical and practical aspects of the implant procedure, and additional special technical cases based on our cumulative experience.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Contração Miocárdica , Terapia por Estimulação Elétrica/efeitos adversos , Desenho de Equipamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Recuperação de Função Fisiológica , Resultado do Tratamento
6.
Europace ; 19(5): 831-837, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-27230561

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) requires effective left ventricular (LV) pacing (i.e. sufficient energy and appropriate timing to capture). The AdaptivCRT™ (aCRT) algorithm serves to maintain ventricular fusion during LV or biventricular pacing. This function was tested by comparing the morphological consistency of ventricular depolarizations and percentage effective LV pacing in CRT patients randomized to aCRT vs. echo-optimization. METHODS AND RESULTS: Continuous recordings (≥20 h) of unipolar LV electrograms from aCRT (n = 38) and echo-optimized patients (n = 22) were analysed. Morphological consistency was determined by the correlation coefficient between each beat and a template beat. Effective LV pacing of paced beats was assessed by algorithmic analysis of negative initial EGM deflection in each evoked response. The %CRT pacing delivered, %effective LV pacing (i.e. % of paced beats with effective LV pacing), and overall %effective CRT (i.e. product of %CRT pacing and %effective LV pacing) were compared between aCRT and echo-optimized patients. Demographics were similar between groups. The mean correlation coefficient between individual beats and template was greater for aCRT (0.96 ± 0.03 vs. 0.91 ± 0.13, P = 0.07). Although %CRT pacing was similar for aCRT and echo-optimized (median 97.4 vs. 98.6%, P = 0.14), %effective LV pacing was larger for aCRT [99.6%, (99.1%, 99.9%) vs. 94.3%, (24.3%, 99.8%), P=0.03]. For aCRT vs. echo-optimized groups, the proportions of patients with ≥90% effective LV pacing was 92 vs. 55% (P = 0.002), and with ≥90% effective CRT was 79 vs. 45%, respectively (P = 0.018). CONCLUSION: AdaptivCRT™ significantly increased effective LV pacing over echo-optimized CRT.


Assuntos
Algoritmos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Terapia Assistida por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos
7.
Artigo em Inglês | MEDLINE | ID: mdl-27562181

RESUMO

BACKGROUND: The evaluation of the QT interval in the presence of left bundle branch block (LBBB) is associated with the challenge to discriminate native QT interval from the prolongation due to the increase in QRS duration. The newest formula to evaluate QT interval in the presence of LBBB suggests: modified QT during LBBB = measured QT interval minus 50% of LBBB duration. The purpose of this study is therefore to validate the abovementioned formula in the clinical setting. METHODS: Validation in two separate groups of patients: Patients who alternated between narrow QRS and intermittent LBBB and patients with narrow QRS who developed LBBB after transcatheter aortic valve implantation (TAVI). RESULTS: The acquired mean native QTc intervals and those calculated by the presented formula displayed no significant differences (p > .99 and p > .75). CONCLUSIONS: In this study we proved for the first time the validity and applicability of the experimentally acquired formula for the evaluation of the QT interval in the presence of LBBB in a clinical setting.


Assuntos
Bloqueio de Ramo/fisiopatologia , Eletrocardiografia/métodos , Fascículo Atrioventricular/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
8.
Europace ; 18(11): 1719-1725, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27485577

RESUMO

AIMS: A long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial. METHODS AND RESULTS: A total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections). A total of 346 fast ventricular tachycardias (FVT) were detected in 169 patients: 208 in 105 patients with SDI and 138 in 64 patients with LDI. Setting LDI determined a significant reduction in appropriate but unnecessary therapies [208 in SDI vs. 138 in LDI; incidence rate ratio (IRR): 0.61 (95% CI 0.45-0.83), P = 0.002]. Anti-tachycardia pacing determined another 52% reduction in unnecessary shocks [208 in SDI with hypothetical shock-only programming vs. 66 in LDI with ATP; IRR: 0.37 (95% CI 0.25-0.53, P < 0.001)]. The efficacy of ATP in terminating FVT was 63% in SDI and 52% in LDI (P = 0.022). No difference in the safety profile (acceleration/degeneration and death/cardiovascular hospitalizations) was observed between the two groups. CONCLUSION: The combination of LDI and ATP during charging is extremely effective and significantly reduces appropriate but unnecessary therapies. The use of LDI alone yielded a 39% reduction in appropriate but unnecessary therapies; ATP on top of LDI determined another 52% reduction in unnecessary shocks. The strategy of associating ATP and LDI could be considered in the majority of ICD recipients.


Assuntos
Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Taquicardia Ventricular/terapia , Idoso , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prevenção Secundária , Método Simples-Cego , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 39(3): 261-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26643821

RESUMO

BACKGROUND: The impact of right ventricular (RV) lead location on clinical end points in patients undergoing cardiac resynchronization therapy (CRT) is unclear. We evaluated the impact of different RV lead locations on clinical outcome in CRT patients enrolled in the Septal Positioning of ventricular implantable cardioverter-defibrillator (ICD) Electrodes (SPICE) trial, which randomized recipients of implantable cardioverter defibrillators to apical versus midseptal RV lead positioning. METHODS: Ninety-eight CRT recipients were included in the multicenter SPICE trial and followed for 12 months: Fifty-three patients were randomized to receive an apical (A) and 45 to receive a midseptal (S) lead position. We compared echocardiographical and electrocardiographical parameters and outcome. RESULTS: Echocardiographic response with respect to improvement of left ventricular ejection fraction (A: +15.8 ± 14.6%, S: +9.7 ± 12.6%, P = 0.156) and reduction of left ventricular end-diastolic diameter (A: -4.2 ± 10.7 mm, S: -7.5 ± 10.7 mm, P = 0.141) was comparable in apical and midseptal groups. Paced QRS width neither differed at prehospital discharge (A: 129 ± 21 ms, S: 135 ± 21 ms, P = 0.133) nor at 12-month follow-up (A: 131 ± 23 ms, S: 134 ± 28 ms, P = 0.620). No differences were found with respect to the risk of ventricular tachyarrhythmia or ICD therapy. Septal RV lead position, however, was associated with a significant longer time to a first heart failure event (P = 0.040) and a longer survival time (P = 0.019). CONCLUSIONS: In CRT recipients, midseptal RV lead position was not superior with respect to improvement of echocardiographic parameters or paced QRS width. It did not predispose to ventricular arrhythmias or ICD therapy. The finding that midseptal lead position was associated with a longer time to first heart failure event and a longer survival time deserves further investigation.


Assuntos
Eletrodos Implantados , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/prevenção & controle , Ventrículos do Coração/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Desfibriladores Implantáveis , Ecocardiografia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Implantação de Prótese/métodos , Volume Sistólico , Resultado do Tratamento , Estados Unidos , Disfunção Ventricular Esquerda/complicações
10.
Circulation ; 130(4): 308-14, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-24838360

RESUMO

BACKGROUND: Three trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients. METHODS AND RESULTS: Of the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤ 320 ms. Eight-five percent of patients were men, with a mean age of 65 ± 12 years, a previous history of ventricular fibrillation in 37% of the cases, and a mean ejection fraction of 38 ± 13%. The ICD device mix was 37% single chamber, 47% dual chamber, and 16% triple chamber. Over a median period of 12 months, the long detection period was associated with a 25% reduction in the number of overall therapies (115.6 versus 86.8 per 100 patient-years; incidence rate ratio, 0.75; 95% confidence interval, 0.61-0.93; P=0.008) and a 34% reduction in the number of shocks (rate per 100 patient-years, 51.2 versus 38.1; incidence rate ratio, 0.66; 95% confidence interval, 0.48-0.89; P=0.007). Appropriate therapies (89.7 versus 67.7; incidence rate ratio, 0.77; 95% confidence interval, 0.60-0.97; P=0.029) and appropriate shocks (37.1 versus 28.1; incidence rate ratio, 0.64; 95% confidence interval, 0.45-0.93; P=0.018) were also reduced. CONCLUSIONS: ADVANCE III is the first randomized trial to assess a long detection window setting in ICDs in both primary and secondary prevention populations and demonstrates a reduction of overall therapies and shocks in the subgroup of secondary prevention patients. These data suggest that even the secondary prevention population may benefit from programming that combines a long detection period with antitachycardia pacing during charging. CLINICAL TRIAL REGISTRATION URL: http://www/clinicaltrials.gov. Unique identifier: NCT00617175.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/métodos , Taquicardia Ventricular/prevenção & controle , Fibrilação Ventricular/prevenção & controle , Idoso , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Falha de Equipamento , Feminino , Frequência Cardíaca , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prevenção Primária , Prevenção Secundária , Método Simples-Cego , Volume Sistólico , Síncope/epidemiologia , Síncope/etiologia , Taquicardia Ventricular/terapia , Fatores de Tempo , Fibrilação Ventricular/terapia
11.
Europace ; 17(6): 915-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25573656

RESUMO

AIMS: Right ventricular (RV) septum is a non-apical site targeted during lead implantation. Electrocardiographic (ECG) recognition of mid-septal lead location is challenging. The aim of the study is to determine ECG correlates of RV mid-septal pacing. METHODS AND RESULTS: The present study is a pre-specified analysis of a prospective, multicenter study, which randomized recipients of an implantable cardioverter defibrillator to an apical vs. mid-septal RV lead positioning. Following implantation, a 12-lead ECG was recorded during intrinsic rhythm and RV pacing. In total, 227 patients, 121 in the apical group (76.9% males, 67.1 ± 11.3 years) and 106 in the mid-septal group (82.1% males, age 64.7 ± 12.7 years) were included. Apically as compared with septally paced patients had significantly longer paced QRS duration (177.0 ± 25.0 vs. 170.4 ± 21.7, respectively, P = 0.03) and significantly more leftward paced QRS axis (-71.6 ± 33.3° vs. 9.4 ± 86.5°, respectively, P < 0.001). A significantly higher proportion of patients in the mid-septal as compared with the apical group displayed predominantly positive QRS in lead V6 (62.3 vs. 4.1%, P < 0.001), predominantly positive QRS in any of the inferior leads (53.8 vs. 4.1%, P < 0.001), and a QR pattern in lead aVL (53.3 vs. 3.3%, P < 0.001). These ECG correlates were incorporated in a stepwise algorithm with total sensitivity of 87% and specificity of 90% for the identification of a mid-septal lead location. CONCLUSION: A mid-septal lead location may be identified using a simple stepwise algorithm, based on the presence of positive QRS in lead V6, positive QRS in any of the inferior leads, and a QR pattern in lead aVL.


Assuntos
Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Eletrocardiografia , Ventrículos do Coração , Implantação de Prótese/métodos , Septo Interventricular , Idoso , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
J Heart Valve Dis ; 23(5): 537-44, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25799701

RESUMO

BACKGROUND AND AIM OF THE STUDY: The aim of this prospective study was to determine the impact of plasma B-type natriuretic peptide (BNP) on long-term outcome in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: TAVI was performed either transfemorally or transaxillary using either the CoreValve prosthesis or Edwards SAPIEN prosthesis in 226 patients with symptomatic severe aortic valve stenosis and at high surgical risk. The examinations included measurements of plasma BNP and echocardiography before and at 30 days after TAVI. The primary study end-point was death from any cause after TAVI; the secondary end-point was defined as cardiovascular death. RESULTS: During a mean follow up of 728 ± 549 days, 72 patients died; 52 deaths were cardiovascular-related. Those patients who died had higher preprocedural plasma BNP levels compared to those who survived (1,305 ± 1,238 pg/ml versus 716 ± 954 pg/ml; p < 0.001). Plasma BNP was the strongest independent predictor of all-cause mortality (BNP > 475 pg/ml, hazard risk [HR] 3.049; 95% confidence interval [CI] 1.804-5.151; p < 0.001) and cardiovascular mortality (BNP > 475 pg/ml, HR 3.479; 95% CI 1.817-6.662; p < 0.001). In surviving patients, plasma BNP levels were decreased by 30 days after TAVI (pre-TAVI 874 ± 1,122 pg/ml; post TAVI 471 ± 569 pg/ml; p < 0.001). A plasma BNP level > 328 pg/ml at 30 days postoperatively was also associated with all-cause mortality (HR 8.125; 95% CI 3.097-21.318; p < 0.001). CONCLUSION: In patients undergoing TAVI, plasma BNP is the strongest independent predictor of all-cause mortality and cardiovascular mortality. Plasma BNP levels at 30 days after TAVI may provide prognostic information that should, potentially, lead to a more intensive therapy of these patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Peptídeo Natriurético Encefálico/sangue , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Causas de Morte , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Análise Multivariada , Prognóstico , Estudos Prospectivos
13.
Artigo em Inglês | MEDLINE | ID: mdl-38383674

RESUMO

BACKGROUND: The aim of the present study was to evaluate the long-term safety and effectiveness of the subcutaneous implantable cardioverter defibrillator (S-ICD) when implanted intermuscularly in patients with end-stage renal disease and hemodialysis. METHODS: This study is a retrospective analysis of 21 consecutive patients implanted with S-ICDs at three experienced centers in Germany with comorbid renal insufficiency requiring hemodialysis, as well as being at risk of sudden cardiac death. The S-ICD was placed intermuscularly in all patients. Follow-ups (FUs) were performed every 6 months. RESULTS: The mean ± standard deviation FU duration was 60.0 ± 11.4 months, with a range of 39 to 78 months. There were no deaths due to arrhythmia, or device-associated infections and complications. Four patients (19.1%) died during FU due to respiratory insufficiency during dialysis, systolic heart failure, septic infection of the urogenital tract, and colorectal cancer, respectively. There were six non-device-related hospitalizations with a duration of 12.7 ± 5.1 days and a hospitalization rate of 4.1 per 100 patient years. CONCLUSIONS: In the long-term FU of this small population of seriously compromised hemodialysis patients at risk of sudden cardiac death, the intermuscularly implanted S-ICD system was safe and effective. No arrhythmic complications, device-associated infections, or complications compromised survival. These data are encouraging and support testing in a larger group of similarly compromised patients.

14.
Front Cardiovasc Med ; 11: 1397138, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660482

RESUMO

Background: Patients with progressive chronic kidney disease (CKD) are at higher risk of infections and complications from cardiac implantable electronic devices (CIED). In patients with a primary or secondary prophylactic indication, implantable cardiac defibrillators (ICD) can prevent sudden cardiac deaths (SCD). We retrospectively compared transvenous-ICD (TV-ICD) and intermuscularly implanted subcutaneous-ICD (S-ICD) associated infections and complication rates together with hospitalizations in recipients with stage 4 kidney disease. Methods: We retrospectively analyzed 70 patients from six German centers with stage 4 CKD who received either a prophylactic TV-ICD with a single right ventricular lead, 49 patients, or a S-ICD, 21 patients. Follow-Ups (FU) were performed bi-annually. Results: The TV-ICD patients were significantly older. This group had more patients with a history of atrial arrhythmias and more were prescribed anti-arrhythmic medication compared with the S-ICD group. There were no significant differences for other baseline characteristics. The median and interquartile range of FU durations were 55.2 (57.6-69.3) months. During FU, patients with a TV-ICD system experienced significantly more device associated infections (n = 8, 16.3% vs. n = 0; p < 0.05), device-associated complications (n = 13, 26.5% vs. n = 1, 4.8%; p < 0.05) and device associated hospitalizations (n = 10, 20.4% vs. n = 1, 4.8%; p < 0.05). Conclusion: In this long-term FU of patients with stage 4 CKD and an indication for a prophylactic ICD, the S-ICD was associated with significantly fewer device associated infections, complications and hospitalizations compared with TV-ICDs.

15.
J Clin Med ; 13(4)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38398357

RESUMO

BACKGROUND: Cephalic vein cutdown (CVC) and subclavian vein puncture (SVP) are the most commonly used access sites for transvenous lead placement of cardiac implantable electronic devices (CIEDs). Limited knowledge exists about the long-term patency of the vascular lumen housing the leads. METHODS: Among the 2703 patients who underwent CIED procedures between 2005 and 2013, we evaluated the phlebographies of 162 patients scheduled for an elective CIED replacement (median of 6.4 years after the first operation). The phlebographies were divided into four stenosis types: Type I = 0%, Type II = 1-69%, Type III = 70-99%, and Type IV = occlusion. Due to the fact that no standardized stenosis categorization exists, experienced physicians in consensus with the involved team made the applied distribution. The primary endpoint was the occurrence of stenosis Type III or IV in the CVC group and in the SVP group. RESULTS: In total, 162 patients with venography were enrolled in this study. The prevalence of high-degree stenosis was significantly lower in the CVC group (7/89, 7.8%) than in the SVP group (15/73, 20.5%, p = 0.023). In the CVC group, venographies showed a lower median stenosis (33%) than in the SVP group (median 42%). CONCLUSIONS: The present study showed that the long-term patency of the subclavian vein is higher after CVC than after SVP for venous access in patients with CIED.

16.
J Emerg Med ; 44(6): 1077-82, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23419213

RESUMO

BACKGROUND: The survival of in-hospital cardiac arrest (8-25%) has not changed substantially in the past. Until now, most hospitals in Germany had no standardized protocols available for a course of action in case of emergency, and there are no continuous registry data for in-hospital cardiac arrest and survival. OBJECTIVE: Our aim was to improve survival and receive outcomes data, so we implemented a structured hospital-wide automated first-responder system in the hospital. Here our 5-year experience with 443 emergency calls is outlined. METHODS: Throughout the hospital, 15 automated external defibrillator (AED) "access spots," which can be easily reached within 30 s, were identified. AEDs were then installed at these locations (Lifepak 500 and Lifepak 1000, Medtronic equipped with a Biolog 3000i portable ECG monitor). At the same time, a training program was initiated in which the employees of the hospital participated once a year. Participants learned how to apply and activate an AED in case of cardiac arrest even before the designated Cardiac Arrest Team arrived at the scene. RESULTS: A witnessed cardiac arrest event was confirmed in 126 cases. In 56 of the 126 cases, the primary arrest rhythm was either ventricular tachycardia or ventricular fibrillation and the AED delivered a shock. In this group, spontaneous circulation was reached in 44 cases (79%) and 23 patients (41%) were discharged. In 44% (24 from 55 patients) of the cases, a shock was recommended by AED and delivered by the first responders before the rescue team arrived. CONCLUSIONS: The first-responder AED program successfully gave training lessons to the hospital staff. The training included how to initiate the cardiac arrest call, how to use the AED, and how to start immediate resuscitation. As a result, a higher survival rate after in-hospital cardiac arrest can be accomplished.


Assuntos
Reanimação Cardiopulmonar , Desfibriladores , Socorristas , Parada Cardíaca/terapia , Idoso , Reanimação Cardiopulmonar/educação , Feminino , Alemanha , Humanos , Masculino , Recursos Humanos em Hospital/educação , Avaliação de Programas e Projetos de Saúde , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
17.
JAMA ; 309(18): 1903-11, 2013 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-23652522

RESUMO

IMPORTANCE: Using more intervals to detect ventricular tachyarrhythmias has been associated with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. OBJECTIVE: To determine whether using 30 of 40 intervals to detect ventricular arrhythmias (VT) (long detection) during spontaneous fast VT episodes reduces antitachycardia pacing (ATP) and shock delivery more than 18 of 24 intervals (standard detection). DESIGN, SETTING, AND PARTICIPANTS: Randomized, single-blind, parallel-group trial that enrolled 1902 primary and secondary prevention patients (mean [SD] age, 65 [11] years; 84% men; 75% primary prevention ICD) with ischemic and nonischemic etiology undergoing first ICD implant at 1 of 94 international centers (March 2008-December 2010). INTERVENTIONS: Patients were randomized 1:1 to programming with long- (n = 948) or standard-detection (n = 954) intervals. MAIN OUTCOMES AND MEASURES: Total number of ATPs and shocks delivered for all episodes (primary outcomes) and inappropriate shocks, mortality, and syncopal rate (secondary outcomes). RESULTS: During a median follow-up of 12 months (interquartile range, 11-13), long-detection group had 346 delivered therapies (42 therapies per 100 person-years, 95% CI, 38-47) vs 557 in the standard-detection group (67 therapies per 100 person-years [95% CI, 62-73]; incident rate ratio [IRR], 0.63 [95% CI, 0.51-0.78]; P < .001). The long- vs the standard-detection group experienced 23 ATPs per 100 person-years (95% CI, 20-27) vs 37 ATPs per 100 person-years (95% CI, 33-41; IRR, 0.58 [95% CI, 0.47-0.72]; P < .001); 19 shocks per 100 person-years (95% CI, 16-22) vs 30 shocks per 100 person-years (95% CI, 26-34; IRR, 0.77 [95% CI, 0.59-1.01]; P = .06), with a significant difference in the probability of therapy occurrence (P < .001); and a reduction in first occurrence of inappropriate shock (5.1 per 100 patient-years [95% CI, 3.7-6.9] vs 11.6 [95% CI, 9.4-14.1]; IRR, 0.55 [95% CI, 0.36-0.85]; P = .008). Mortality (5.5 [95% CI, 4.0-7.2] vs 6.3 [95% CI, 4.8-8.2] per 100 patient-years; HR, 0.87; P = .50) and arrhythmic syncope rates (3.1 [95% CI, 2.6-4.6] vs 1.9 [95% CI, 1.1-3.1] per 100 patient-years; IRR, 1.60 [95% CI, 0.76-3.41]; P = .22) did not differ significantly between groups. CONCLUSIONS AND RELEVANCE: Among patients receiving an ICD, the use of a long- vs standard-detection interval resulted in a lower rate of ATP and shocks, and inappropriate shocks. This programming strategy may be an appropriate alternative. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00617175.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/métodos , Idoso , Algoritmos , Arritmias Cardíacas/mortalidade , Estimulação Cardíaca Artificial , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Prevenção Primária , Qualidade de Vida , Prevenção Secundária , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
18.
Herzschrittmacherther Elektrophysiol ; 34(4): 333-338, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37874381

RESUMO

In recent years, imaging techniques have improved enormously. This leads to a decrease in stress testing indication for diagnosis and management of coronary artery diseases. However, stress testing remains an indispensable diagnostic tool for assessing patients' physical activity and their circulatory behavior during exercise. Using stress testing helps to assess patients' heart rate behavior or even to detect or trigger cardiac arrhythmias, for example, assessment of chronotropic competency, tachycardia-triggering or detection of a sudden heart rate drop with relevant bradycardia. The present review focuses on the assessment of stress testing in rhythmology. Since abnormal findings, which may indicate the presence of coronary heart disease, may occur during exercise testing, relevant ischemic criteria are also briefly addressed.


Assuntos
Doença da Artéria Coronariana , Eletrocardiografia , Humanos , Teste de Esforço , Arritmias Cardíacas/diagnóstico , Taquicardia
19.
J Clin Med ; 12(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38137682

RESUMO

BACKGROUND: Infection, lead dysfunction and system upgrades are all reasons that transvenous lead extraction is being performed more frequently. Many centres focus on a single method for lead extraction, which can lead to either lower success rates or higher rates of major complications. We report our experience with a systematic approach from a less invasive to a more invasive strategy without the use of laser sheaths. METHODS: Consecutive extraction procedures performed over a period of seven years in our electrophysiology laboratory were included. We performed a stepwise approach with careful traction, lead locking stylets (LLD), mechanical non-powered dilator sheaths, mechanical powered sheaths and, if needed, femoral snares. RESULTS: In 463 patients (age 69.9 ± 12.3, 31.3% female) a total of 780 leads (244 ICD leads) with a mean lead dwelling time of 5.4 ± 4.9 years were identified for extraction. Success rates for simple traction, LLD, mechanical non-powered sheaths and mechanical powered sheaths were 31.5%, 42.7%, 84.1% and 92.6%, respectively. A snare was used for 40 cases (as the primary approach for 38 as the lead structure was not intact and stepwise approach was not feasible) and was successful for 36 leads (90.0% success rate). Total success rate was 93.1%, clinical success rate was 94.1%. Rate for procedural failure was 1.1%. Success for less invasive steps and overall success for extraction was associated with shorter lead dwelling time (p < 0.001). Major procedure associated complications occurred in two patients (0.4%), including one death (0.2%). A total of 36 minor procedure-associated complications occurred in 30 patients (6.5%). Pocket hematoma correlated significantly with uninterrupted dual antiplatelet therapy (p = 0.001). Pericardial effusion without need for intervention was associated with long lead dwelling time (p = 0.01) and uninterrupted acetylsalicylic acid (p < 0.05). CONCLUSION: A stepwise approach with a progressive invasive strategy is effective and safe for transvenous lead extraction.

20.
Sci Rep ; 13(1): 22964, 2023 12 27.
Artigo em Inglês | MEDLINE | ID: mdl-38151554

RESUMO

There is a rising number in complications associated with more cardiac electrical devices implanted (CIED). Infection and lead dysfunction are reasons to perform transvenous lead extraction. An ideal anaesthetic approach has not been described yet. Most centres use general anaesthesia, but there is a lack in studies looking into deep sedation (DS) as an anaesthetic approach. We report our retrospective experience for a large number of procedures performed with deep sedation as a primary approach. Extraction procedures performed between 2011 and 2018 in our electrophysiology laboratory have been included retrospectively. We began by applying a bolus injection of piritramide followed by midazolam as primary medication and would add etomidate if necessary. For extraction of leads a stepwise approach with careful traction, locking stylets, dilator sheaths, mechanical rotating sheaths and if needed snares and baskets has been used. A total of 780 leads in 463 patients (age 69.9 ± 12.3, 31.3% female) were extracted. Deep sedation was successful in 97.8% of patients. Piritramide was used as the main analgesic medication (98.5%) and midazolam as the main sedative (94.2%). Additional etomidate was administered in 15.1% of cases. In 2.2% of patients a conversion to general anaesthesia was required as adequate level of DS was not achieved before starting the procedure. Sedation related complications occurred in 1.1% (n = 5) of patients without sequalae. Deep sedation with piritramide, midazolam and if needed additional etomidate is a safe and feasible strategy for transvenous lead extraction.


Assuntos
Anestésicos , Sedação Profunda , Desfibriladores Implantáveis , Etomidato , Marca-Passo Artificial , Humanos , Feminino , Masculino , Midazolam/efeitos adversos , Estudos Retrospectivos , Pirinitramida , Sedação Profunda/efeitos adversos , Sedação Profunda/métodos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA