Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 38(12): 2222-2230, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28705821

RESUMO

Cardiac implantable electronic devices are frequently encountered in clinical practice in patients being screened for MR imaging examinations. Traditionally, the presence of these devices has been considered a contraindication to undergoing MR imaging. Growing evidence suggests that most of these patients can safely undergo an MR imaging examination if certain conditions are met. This document will review the relevant cardiac implantable electronic devices encountered in practice today, the background physics/technical factors related to scanning these devices, the multidisciplinary screening protocol used at our institution for scanning patients with implantable cardiac devices, and our experience in safely performing these examinations since 2010.


Assuntos
Contraindicações de Procedimentos , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/efeitos adversos , Marca-Passo Artificial , Humanos , Imageamento por Ressonância Magnética/métodos
2.
Circulation ; 99(23): 3024-7, 1999 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-10368120

RESUMO

BACKGROUND: Conversion of chronic atrial fibrillation (AF) is associated with atrial stunning, but the short-term effect of a brief episode of AF on left atrial appendage (LAA) emptying velocity is unknown. The purpose of this study was to determine whether a short episode of AF affects left atrial function and whether verapamil modifies this effect. METHODS AND RESULTS: The subjects of this study were 19 patients without structural heart disease undergoing an electrophysiology procedure. In 13 patients, LAA emptying velocity was measured by transesophageal echocardiography in the setting of pharmacological autonomic blockade before, during, and after a short episode of AF. During sinus rhythm, the baseline LAA emptying velocity was measured 5 times and averaged. AF was then induced by rapid right atrial pacing. After either spontaneous or electrical conversion, LAA emptying velocity was measured immediately on resumption of sinus rhythm and every minute thereafter. The mean duration of AF was 15.3+/-3.8 minutes. The mean baseline emptying velocity was 70+/-20 cm/s. The first post-AF emptying velocity was 63+/-20 cm/s (P=0.02 versus baseline emptying velocity). The post-AF emptying velocity returned to the baseline emptying velocity value after 3.0 minutes. The mean percent reduction in post-AF emptying velocity was 9.7+/-21% (range, 15% increase to 56% decrease). A second group of 6 patients were pretreated with verapamil (0.1-mg/kg IV bolus followed by an infusion of 0.005 mg. kg-1. min-1). In these patients, the first post-AF emptying velocity, 58+/-14 cm/s, was not significantly different from the pre-AF emptying velocity, 60+/-13 cm/s (P=0.08). CONCLUSIONS: In humans, several minutes of AF may be sufficient to induce atrial contractile dysfunction after cardioversion. When atrial contractile dysfunction occurs, there is recovery of AF within several minutes. AF-induced contractile dysfunction is attenuated by verapamil and may be at least partially mediated by cellular calcium overload.


Assuntos
Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo/fisiologia , Bloqueadores dos Canais de Cálcio/farmacologia , Verapamil/farmacologia , Adulto , Fibrilação Atrial/prevenção & controle , Função do Átrio Esquerdo/efeitos dos fármacos , Função do Átrio Direito , Estimulação Cardíaca Artificial , Ablação por Cateter , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Fatores de Tempo
3.
Circulation ; 102(20): 2503-8, 2000 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-11076824

RESUMO

BACKGROUND: Atrial fibrillation (AF) shortens the atrial effective refractory period (ERP) and predisposes to further episodes of AF. The acute changes in atrial refractoriness may be related to tachycardia-induced intracellular calcium overload. The purpose of this study was to determine whether digoxin, which increases intracellular calcium, potentiates the acute effects of AF on atrial refractoriness in humans. METHODS AND RESULTS: In 38 healthy adults, atrial ERP was measured at basic drive cycle lengths (BDCLs) of 350 and 500 ms after autonomic blockade. Nineteen patients had been treated with digoxin for 2 weeks. After a several-minute episode of AF, atrial ERP was measured serially at alternating BDCLs. Compared with pre-AF ERPs, the first post-AF ERPs were significantly shorter in both the digoxin and the control groups (P:<0.001). The post-AF ERP at a BDCL of 350 ms shortened to a greater degree in the digoxin group (37+/-16 ms) than in the control group (20+/-13 ms, P:<0.001); similar changes occurred at a BDCL of 500 ms. During post-AF determinations of the atrial ERP, secondary AF episodes occurred significantly more often in the digoxin group (32% versus 16%; P:<0. 04). CONCLUSIONS: After a brief episode of AF, digoxin augments the shortening that occurs in atrial refractoriness and predisposes to the reinduction of AF. These effects occur in the setting of autonomic blockade and therefore are more likely to be due to the effects of digoxin on intracellular calcium than to its vagotonic effects.


Assuntos
Fibrilação Atrial/metabolismo , Cálcio/metabolismo , Digoxina/farmacologia , Taquicardia Supraventricular/metabolismo , Taquicardia Ventricular/metabolismo , Administração Oral , Antagonistas Adrenérgicos beta/administração & dosagem , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Cardiotônicos/farmacologia , Eletrocardiografia/efeitos dos fármacos , Feminino , Átrios do Coração/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Infusões Intravenosas , Líquido Intracelular/metabolismo , Masculino , Parassimpatolíticos/administração & dosagem , Tempo de Reação/efeitos dos fármacos , Taquicardia Supraventricular/complicações , Taquicardia Supraventricular/terapia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia
4.
J Am Coll Cardiol ; 32(4): 1068-73, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9768734

RESUMO

OBJECTIVES: The purpose of this study was to assess the utility of inhaled nitric oxide (NO), a selective pulmonary vasodilator, for predicting the safety and acute hemodynamic response to high-dose oral nifedipine in primary pulmonary hypertension (PPH). BACKGROUND: A significant decrease in pulmonary vascular resistance with an oral nifedipine challenge is predictive of an improved prognosis, and potential clinical efficacy in PPH. However, the required nifedipine trial carries significant first-dose risk of hypotension. While inhaled NO has been recommended for assessing pulmonary vasodilator reserve in PPH, it is not known whether it predicts the response to nifedipine. METHODS: Seventeen patients with PPH undergoing a nifedipine trial were assessed for hemodynamic response to inhaled NO at 80 parts per million for 5 minutes. The nifedipine trial consisted of 20 mg of nifedipine hourly for 8 hours unless limited by hypotension or intolerable side effects. Patients were classified as responders and nonresponders with positive response defined as > or =20% reduction in mean pulmonary artery pressure (mPA) or pulmonary vascular resistance (PVR) with the vasodilator administration. RESULTS: NO was safely administered to all participants. Seven of 17 (41.2%) responded to NO, and 8 of the 17 to nifedipine (47.1%). Nifedipine was safely administered in 14 of the 17. Three suffered either mild or severe hypotension, including one death. All NO responders also responded to nifedipine, and 9 of the 10 NO nonresponders were nifedipine nonresponders, representing a sensitivity of 87.5%, specificity of 100%, and overall predictive accuracy of 94%. All NO responders tolerated a full nifedipine trial without hypotension. There was a highly significant correlation between the effects of NO and nifedipine on PVR (r=0.67, p=0.003). CONCLUSIONS: The pulmonary vascular response to inhaled NO accurately predicts the acute hemodynamic response to nifedipine in PPH, and a positive response to NO is associated with a safe nifedipine trial. In patients comparable with those evaluated, a trial of nifedipine in NO nonresponders appears unwarranted and potentially dangerous.


Assuntos
Bloqueadores dos Canais de Cálcio/uso terapêutico , Hipertensão Pulmonar/tratamento farmacológico , Nifedipino/uso terapêutico , Óxido Nítrico/administração & dosagem , Vasodilatadores/uso terapêutico , Administração por Inalação , Administração Oral , Bloqueadores dos Canais de Cálcio/efeitos adversos , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Hipertensão Pulmonar/fisiopatologia , Hipotensão/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Nifedipino/efeitos adversos , Circulação Pulmonar/efeitos dos fármacos , Resistência Vascular/efeitos dos fármacos , Vasodilatadores/efeitos adversos
5.
J Am Coll Cardiol ; 35(7): 1915-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10841243

RESUMO

OBJECTIVES: The purpose of this randomized study was to evaluate the prevalence of pocket hematomas in patients treated with heparin 6 h or 24 h after pacemaker or defibrillator implantation. BACKGROUND: The risks of pocket hematoma and need for evacuation after device implantation have not been defined in patients who require anticoagulation. METHODS: Forty-nine consecutive patients with an indication for anticoagulation with heparin after implantable defibrillator or pacemaker implantation were randomized to receive intravenous heparin either 6 h (n = 26) or 24 h (n = 23) postoperatively. Both groups also received warfarin on a daily basis starting the evening of surgery. Twenty-eight patients who received postoperative warfarin alone and 115 patients who did not receive anticoagulation were followed up in a study registry. RESULTS: A pocket hematoma developed in 6 of 26 patients (22%) who were treated with intravenous heparin 6 h postoperatively, as compared with 4 of 23 patients (17%) who were treated with intravenous heparin 24 h postoperatively (p = 0.7). In total, a pocket hematoma developed in 10 of 49 patients (20%) treated with heparin, 1 of 28 patients (4%) treated with warfarin alone and 2 of 115 (2%) patients who received no anticoagulation (p < 0.001). CONCLUSIONS: Intravenous heparin initiation 6 h or 24 h after pacemaker or defibrillator implantation is associated with a 20% prevalence of pocket hematoma formation. Warfarin therapy or no anticoagulation is associated with only a 2% to 4% risk of pocket hematoma formation.


Assuntos
Anticoagulantes/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Hematoma/etiologia , Hematoma/prevenção & controle , Heparina/uso terapêutico , Marca-Passo Artificial/efeitos adversos , Varfarina/uso terapêutico , Esquema de Medicação , Feminino , Hematoma/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Fatores de Tempo
6.
J Am Coll Cardiol ; 35(2): 414-21, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10676689

RESUMO

OBJECTIVES: The purpose of this study was to describe a computerized mapping system that utilizes a noncontact, 64 electrode balloon catheter to compute virtual electrograms simultaneously at 3,360 left ventricular (LV) sites and to assess the clinical utility of this system for mapping and ablating ventricular tachycardia (VT). BACKGROUND: Mapping VT in the electrophysiology laboratory conventionally is achieved by sequentially positioning an electrode catheter at multiple endocardial sites. METHODS: Fifteen patients with VT underwent 18 electrophysiology procedures using the noncontact, computerized mapping system. A 9F 64 electrode balloon catheter and a conventional 7F electrode catheter for mapping and ablation were positioned in the LV using a retrograde aortic approach. Using a boundary element inverse solution, 3,360 virtual endocardial electrograms were computed and used to derive isopotential maps. An incorporated locator system was used in conjunction with or instead of fluoroscopy to position the conventional electrode catheter. RESULTS: A total of 21 VTs, 12 of which were hemodynamically-tolerated and 9 of which were not, were mapped. Isolated diastolic potentials, presystolic areas, zones of slow conduction and exit sites during VT were identified using virtual electrograms and isopotential maps. Among 19 targeted VTs, radiofrequency ablation guided by the computerized mapping system and the locator signal was successful in 15. CONCLUSIONS: The computerized mapping system described in this study computes accurate isopotential maps that are a useful guide for ablation of hemodynamically stable or unstable VT.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Processamento de Imagem Assistida por Computador , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Eletrofisiologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Resultado do Tratamento , Interface Usuário-Computador
7.
J Am Coll Cardiol ; 33(7): 1964-70, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10362200

RESUMO

OBJECTIVES: The purpose of this study was to determine the outcome of patients with nonischemic dilated cardiomyopathy, unexplained syncope and a negative electrophysiology test who are treated with an implantable defibrillator. BACKGROUND: Patients with nonischemic cardiomyopathy and unexplained syncope may be at high risk for sudden cardiac death, and they are sometimes treated with an implantable defibrillator. METHODS: This study prospectively determined the outcome of 14 consecutive patients who had a nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test and who underwent defibrillator implantation (Syncope Group). Nineteen consecutive patients with a nonischemic cardiomyopathy and a cardiac arrest who were treated with a defibrillator (Arrest Group) served as a control group. RESULTS: Seven of 14 patients (50%) in the Syncope Group received appropriate shocks for ventricular arrhythmias during a mean follow-up of 24+/-13 months, compared with 8 of 19 patients (42%) in the Arrest Group during a mean follow-up of 45+/-40 months (p = 0.1). The mean duration from device implantation until the first appropriate shock was 32+/-7 months (95% confidence interval [CI], 18 to 45 months) in the Syncope Group compared to 72+/-12 months (95% CI, 48 to 96 months) in the Arrest Group (p = 0.1). Among patients who received appropriate shocks, the mean time from defibrillator implantation to the first appropriate shock was 10+/-14 months in the Syncope Group, compared with 48+/-47 months in the Arrest Group (p = 0.06). Recurrent syncope was always associated with ventricular tachyarrhythmias. CONCLUSIONS: The high incidence of appropriate defibrillator shocks and the association of recurrent syncope with ventricular arrhythmias support the treatment of patients with nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test with an implantable defibrillator.


Assuntos
Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Síncope/terapia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/mortalidade , Eletrocardiografia , Feminino , Seguimentos , Parada Cardíaca/etiologia , Parada Cardíaca/mortalidade , Parada Cardíaca/terapia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Taxa de Sobrevida , Síncope/etiologia , Síncope/mortalidade , Taquicardia Ventricular/complicações , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Resultado do Tratamento
8.
J Am Coll Cardiol ; 36(2): 574-82, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10933374

RESUMO

OBJECTIVES: The purpose of this prospective study was to quantitate the diagnostic value of several tachycardia features and pacing maneuvers in patients with paroxysmal supraventricular tachycardia (PSVT) in the electrophysiology laboratory. BACKGROUND: No study has prospectively compared the value of multiple diagnostic tools in a large group of patients with PSVT. METHODS: One hundred ninety-six consecutive patients who had 200 inducible sustained PSVTs during an electrophysiology procedure were included. The diagnostic values of four baseline electrophysiologic parameters, nine tachycardia features and five diagnostic pacing maneuvers were quantified. RESULTS: The only tachycardia characteristic that was diagnostic of atrioventricular (AV) nodal reentry was a septal ventriculoatrial (VA) time of <70 ms, and no pacing maneuver was diagnostic for AV nodal reentry. An increase in the VA interval with the development of a bundle branch block was the only tachycardia characteristic that was diagnostic for orthodromic tachycardia, but it occurred in only 7% of all tachycardias. An atrial-atrial-ventricular response upon cessation of ventricular overdrive pacing was diagnostic of atrial tachycardia, and this maneuver could be applied to 78% of all tachycardias. Burst ventricular pacing excluded atrial tachycardia when the tachycardia terminated without depolarization of the atrium, but the result could be obtained only in 27% of patients. CONCLUSIONS: This prospective study quantitates the diagnostic value of multiple observations and pacing maneuvers that are commonly used during PSVT in the electrophysiology laboratory. The findings demonstrate that diagnostic techniques rarely provide a diagnosis when used individually. Therefore, careful observations and multiple pacing maneuvers are often required for an accurate diagnosis during PSVT. The results of this study provide a useful reference with which new diagnostic techniques can be compared.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Taquicardia Paroxística/diagnóstico , Taquicardia Supraventricular/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Paroxística/fisiopatologia , Taquicardia Supraventricular/fisiopatologia
9.
J Am Coll Cardiol ; 30(2): 505-13, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9247525

RESUMO

OBJECTIVES: The goal of this study was to determine whether isolated diastolic potentials (IDPs) recorded during ventricular tachycardia (VT) are generated in zones of slow conduction and whether the arcs of block that bound these zones of slow conduction are functional or anatomic in nature. BACKGROUND: No previous studies have systematically investigated the response to pacing during VT and sinus rhythm at sites where IDPs are recorded. METHODS: The study included 11 patients with a previous infarction who underwent radiofrequency catheter ablation of 15 hemodynamically stable, sustained VTs and in whom an IDP that could not be dissociated from the VT was detected during mapping. RESULTS: Pacing during VT at the site where the IDP was recorded resulted in concealed entrainment in each of the 15 VTs. In 10 of the 15 VTs, an IDP was present during sinus rhythm at the same site at which a diastolic potential was recorded during VT. In nine VTs, the isolated potential occurred early in diastole; in these cases, the QRS configuration during pacing in the setting of sinus rhythm was different from that during VT. In six VTs, the isolated potential occurred later in diastole, and in these cases, the QRS configuration during pacing in the setting of sinus rhythm was the same as that during VT. CONCLUSIONS: Isolated diastolic potentials may often be generated in an area of slow conduction bounded by arcs of block that are anatomically determined and present during sinus rhythm.


Assuntos
Estimulação Cardíaca Artificial , Infarto do Miocárdio/complicações , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter , Diástole/fisiologia , Eletrocardiografia , Eletrofisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
J Am Coll Cardiol ; 29(1): 113-21, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8996303

RESUMO

OBJECTIVES: The purpose of this study was to describe the long-term follow-up results in 62 patients with atrial fibrillation and an uncontrolled ventricular rate, who underwent radiofrequency modification of the atrioventricular (AV) node. BACKGROUND: Previous studies in small numbers of patients have suggested that radiofrequency modification may be effective in controlling the ventricular rate in patients with atrial fibrillation, but long-term follow-up data have been lacking. METHODS: The subjects of this study were 62 consecutive patients (mean age +/- SD 65 +/- 14 years; 43 with structural heart disease) who underwent an attempt at radiofrequency modification of the AV node because of symptomatic, drug-refractory atrial fibrillation with an uncontrolled ventricular rate. The atrial fibrillation was chronic in 46 patients and paroxysmal in 16. Radiofrequency energy was applied to the posteroseptal or mid-septal right atrium to lower the ventricular rate in atrial fibrillation to 120 to 130 beats/min during an infusion of 4 micrograms/min of isoproterenol. RESULTS: Short-term control of the ventricular rate was successfully achieved without the induction of pathologic AV block in 50 (81%) of 62 patients. Inadvertent high degree AV block occurred in 10 (16%) of 62 patients, with the AV block occurring at the time of the procedure in 6 patients and 36 to 72 h after the procedure in 4. During 19 +/- 8 months of follow-up (range 4 to 33), 5 (10%) of 50 patients had a symptomatic recurrence of an uncontrolled rate during atrial fibrillation. Overall, adequate rate control at rest and during exertion, without pathologic AV block, was achieved long term in 45 (73%) of 62 patients. Among 37 patients with a successful outcome, left ventricular ejection fraction increased from (mean +/- SD) 0.44 +/- 0.14 to 0.51 +/- 0.10 one year later (p < 0.001). Complications other than AV block included polymorphic ventricular tachycardia 10 to 24 h after the procedure in two patients who had a predisposing factor for ventricular tachycardia and sudden death 1 to 5 months after the procedure in two patients with idiopathic dilated cardiomyopathy, one of whom had a pacemaker for AV block. CONCLUSIONS: In approximately 70% of properly selected patients with atrial fibrillation and an uncontrolled ventricular rate, radiofrequency modification of the AV node results in excellent long-term control of the ventricular rate at rest and during exertion.


Assuntos
Fibrilação Atrial/cirurgia , Nó Atrioventricular/cirurgia , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Nó Atrioventricular/fisiopatologia , Ablação por Cateter/efeitos adversos , Doença Crônica , Eletrocardiografia Ambulatorial , Teste de Esforço , Feminino , Seguimentos , Bloqueio Cardíaco/etiologia , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
11.
J Am Coll Cardiol ; 33(3): 775-81, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10080480

RESUMO

OBJECTIVE: The purpose of this study was to determine if the atrial response upon cessation of ventricular pacing associated with 1:1 ventriculoatrial conduction during paroxysmal supraventricular tachycardia is a useful diagnostic maneuver in the electrophysiology laboratory. BACKGROUND: Despite various maneuvers, it can be difficult to differentiate atrial tachycardia from other forms of paroxysmal supraventricular tachycardia. METHODS: The response upon cessation of ventricular pacing associated with 1:1 ventriculoatrial conduction was studied during four types of tachycardia: 1) atrioventricular nodal reentry (n = 102), 2) orthodromic reciprocating tachycardia (n = 43), 3) atrial tachycardia (n = 19) and 4) atrial tachycardia simulated by demand atrial pacing in patients with inducible atrioventricular nodal reentry or orthodromic reciprocating tachycardia (n = 32). The electrogram sequence upon cessation of ventricular pacing was, categorized as "atrial-ventricular" (A-V) or "atrial-atrial-ventricular" (A-A-V). RESULTS: The A-V response was observed in all cases of atrioventricular nodal reentrant and orthodromic reciprocating tachycardia. In contrast, the A-A-V response was observed in all cases of atrial tachycardia and simulated atrial tachycardia, even in the presence of dual atrioventricular nodal pathways or a concealed accessory atrioventricular pathway. CONCLUSIONS: In conclusion, an A-A-V response upon cessation of ventricular pacing associated with 1:1 ventriculoatrial conduction is highly sensitive and specific for the identification of atrial tachycardia in the electrophysiology laboratory.


Assuntos
Eletrofisiologia/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Paroxística/diagnóstico , Adolescente , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Gravidez , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia Atrial Ectópica/fisiopatologia , Taquicardia Paroxística/fisiopatologia
12.
J Am Coll Cardiol ; 38(3): 750-5, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11527628

RESUMO

OBJECTIVES: The purpose of this study was to determine the characteristics of double potentials (DPs) that are helpful in guiding ablation within the cavo-tricuspid isthmus. BACKGROUND: Double potentials have been considered a reliable criterion of cavo-tricuspid isthmus block in patients undergoing radiofrequency ablation of typical atrial flutter (AFL). However, the minimal degree of separation of the two components of DPs needed to indicate complete block has not been well defined. METHODS: Radiofrequency ablation was performed in 30 patients with isthmus-dependent AFL. Bipolar electrograms were recorded along the ablation line during proximal coronary sinus pacing at sites at which radiofrequency ablation resulted in incomplete or complete isthmus block. RESULTS: Double potentials were observed at 42% of recording sites when there was incomplete isthmus block, compared with 100% of recording sites when the block was complete. The mean intervals separating the two components of DPs were 65 +/- 21 ms and 135 +/- 30 ms during incomplete and complete block, respectively (p < 0.001). An interval separating the two components of DPs (DP(1-2) interval) <90 ms was always associated with a local gap, whereas a DP(1-2) interval > or =110 ms was always associated with local block. When the DP(1-2) interval was between 90 and 110 ms, an isoelectric segment within the DP and a negative polarity in the second component of the DP were helpful in indicating local isthmus block. A DP(1-2) interval > or =90 ms with a maximal variation of 15 ms along the entire ablation line was an indicator of complete block in the cavo-tricuspid isthmus. CONCLUSIONS: Detailed analysis of DPs is helpful in identifying gaps in the ablation line and in distinguishing complete from incomplete isthmus block in patients undergoing radiofrequency ablation of typical AFL.


Assuntos
Flutter Atrial/cirurgia , Função Atrial , Ablação por Cateter , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação/fisiologia , Idoso , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Valva Tricúspide/fisiopatologia , Veias Cavas/fisiopatologia
13.
J Am Coll Cardiol ; 38(4): 1163-7, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11583898

RESUMO

OBJECTIVES: The purpose of this study was to determine whether the response to ventricular pacing during tachycardia is useful for differentiating atypical atrioventricular node re-entrant tachycardia (AVNRT) from orthodromic reciprocating tachycardia (ORT) using a septal accessory pathway. BACKGROUND: Although it is usually possible to differentiate atypical AVNRT from ORT using a septal accessory pathway, a definitive diagnosis is occasionally elusive. METHODS: In 30 patients with atypical AVNRT and 44 patients with ORT using a septal accessory pathway, the right ventricle was paced at a cycle length 10 to 40 ms shorter than the tachycardia cycle length (TCL). The ventriculo-atrial (VA) interval and TCL were measured just before pacing. The interval between the last pacing stimulus and the last entrained atrial depolarization (stimulus-atrial [S-A] interval) and the post-pacing interval (PPI) at the right ventricular apex were measured on cessation of ventricular pacing. RESULTS: All 30 patients with atypical AVNRT and none of the 44 patients with ORT using a septal accessory pathway had an S-A-VA interval >85 ms and PPI-TCL >115 ms. CONCLUSIONS: The S-A-VA interval and PPI-TCL are useful in distinguishing atypical AVNRT from ORT using a septal accessory pathway.


Assuntos
Estimulação Cardíaca Artificial , Sistema de Condução Cardíaco , Septos Cardíacos/inervação , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Paroxística/diagnóstico , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Paroxística/terapia
14.
J Am Coll Cardiol ; 34(5): 1595-601, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10551711

RESUMO

OBJECTIVES: We compared the efficacy of a novel rectilinear biphasic waveform, consisting of a constant current first phase, with a damped sine wave monophasic waveform during transthoracic defibrillation. BACKGROUND: Multiple studies have shown that for endocardial defibrillation, biphasic waveforms have a greater efficacy than monophasic waveforms. More recently, a 130-J truncated exponential biphasic waveform was shown to have equivalent efficacy to a 200-J damped sine wave monophasic waveform for transthoracic ventricular defibrillation. However, the optimal type of biphasic waveform is unknown. METHODS: In this prospective, randomized, multicenter trial, 184 patients who underwent ventricular defibrillation were randomized to receive a 200-J damped sine wave monophasic or 120-J rectilinear biphasic shock. RESULTS: First-shock efficacy of the biphasic waveform was significantly greater than that of the monophasic waveform (99% vs. 93%, p = 0.05) and was achieved with nearly 60% less delivered current (14 +/- 1 vs. 33 +/- 7 A, p < 0.0001). Although the efficacy of the biphasic and monophasic waveforms was comparable in patients with an impedance < 70 ohms (100% [biphasic] vs. 95% [monophasic], p = NS), the biphasic waveform was significantly more effective in patients with an impedance > or = 70 ohms (99% [biphasic] vs. 86% [monophasic], p = 0.02). CONCLUSIONS: This study demonstrates a superior efficacy of rectilinear biphasic shocks as compared with monophasic shocks for transthoracic ventricular defibrillation, particularly in patients with a high transthoracic impedance. More important, biphasic shocks defibrillated with nearly 60% less current. The combination of increased efficacy and decreased current requirements suggests that biphasic shocks as compared with monophasic shocks are advantageous for transthoracic ventricular defibrillation.


Assuntos
Arritmias Cardíacas/terapia , Cardioversão Elétrica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
15.
Am J Med ; 105(4): 275-80, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9809687

RESUMO

PURPOSE: Adenosine is a useful agent for the diagnosis and termination of tachycardias. The purpose of this study was to identify the rhythms for which adenosine is prescribed in hospitalized adults and to identify the reasons for its misuse. PATIENTS AND METHODS: Data were collected from the medical records of 100 patients who received intravenous adenosine while hospitalized at a university medical center. The characteristics of the patients, rhythms treated with adenosine, and dosages of adenosine were analyzed. In addition, internal medicine house officers were administered a questionnaire referring to an electrocardiogram of atrial fibrillation with a rapid ventricular response. RESULTS: The arrhythmias for which adenosine was administered consisted of regular, narrow-QRS complex tachycardias in 33% of patients; atrial fibrillation in 32% of patients; regular, wide-QRS complex tachycardias in 23% of patients; atrial flutter in 10% of patients, and multifocal atrial tachycardia in 2% of patients. The mean (+/-SD) number of doses of adenosine given to each patient was 1.6+/-0.8, and the mean dose of adenosine was 7.8+/-2.8 mg. Internal medicine house officers prescribed 70% of the doses of adenosine and were as likely to use it for patients with atrial fibrillation as were surgical house officers. There was a 2% incidence of proarrhythmia, including asystole and polymorphic ventricular tachycardia. Thirty-one percent of the 100 house officers in our survey misdiagnosed a 12-lead electrocardiogram of rapid atrial fibrillation as paroxysmal supraventricular tachycardia, suggesting that adenosine may have been misused for atrial fibrillation because of errors in rhythm diagnosis. Only 5% of those who correctly diagnosed atrial fibrillation also answered that adenosine would be likely to terminate the arrhythmia, suggesting that a misunderstanding that adenosine terminates atrial fibrillation is not a common reason for its misuse. CONCLUSIONS: Approximately 40% of hospitalized adults who are treated with adenosine receive the medication unnecessarily for atrial fibrillation or atrial flutter, and this misuse results in unnecessary expenses and risks of adverse effects. The primary reason that adenosine is misused for atrial fibrillation is the inability to recognize that rhythm on an electrocardiogram. House officers need additional education on the electrocardiographic recognition of atrial fibrillation.


Assuntos
Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Sistema de Condução Cardíaco/efeitos dos fármacos , Taquicardia/tratamento farmacológico , Adulto , Idoso , Fibrilação Atrial/tratamento farmacológico , Flutter Atrial/tratamento farmacológico , Eletrocardiografia/efeitos dos fármacos , Feminino , Hospitalização , Hospitais Universitários , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Taquicardia/fisiopatologia
16.
Am J Med ; 110(5): 335-8, 2001 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-11286946

RESUMO

BACKGROUND: Patients who are misdiagnosed with ventricular tachycardia because of electrocardiographic artifact may be subjected to unnecessary procedures. The purpose of this study was to determine how often electrocardiographic artifact is misdiagnosed as ventricular tachycardia. METHODS: Physicians (n = 766) were surveyed with a case simulation that included a two-lead electrocardiographic monitor tracing of artifact simulating a wide-complex tachycardia. RESULTS: The rhythm strip was not recognized as artifact by 52 of the 55 internists (94%), 128 of the 221 cardiologists (58%), and 186 of the 490 electrophysiologists (38%). One hundred fifty-six of the 181 electrophysiologists (88%), 67 of the 126 cardiologists (53%), and 14 of the 15 internists (31%) who misdiagnosed the rhythm as ventricular tachycardia recommended an invasive procedure for further evaluation or therapy. CONCLUSIONS: This physician survey suggests that electrocardiographic artifact that mimics ventricular tachycardia may frequently result in patients being subjected to unnecessary invasive cardiac procedures. Physicians should include artifact in their differential diagnosis of wide complex tachycardias to minimize unneeded procedures.


Assuntos
Artefatos , Competência Clínica/estatística & dados numéricos , Erros de Diagnóstico , Eletrocardiografia , Médicos/normas , Taquicardia Ventricular/diagnóstico , Procedimentos Desnecessários , Cardiologia , Certificação , Diagnóstico Diferencial , Eletrofisiologia , Humanos , Medicina Interna , Médicos/estatística & dados numéricos , Taquicardia Ventricular/fisiopatologia , Estados Unidos
17.
Am J Cardiol ; 80(2): 226-7, 1997 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-9230170

RESUMO

This study determined the efficacy of single- and multisite atrial pacing for terminating episodes of atrial fibrillation induced in patients in the electrophysiology laboratory. One- to 5-second bursts of atrial pacing at a cycle length of 20 ms were not effective in terminating atrial fibrillation, when delivered either in the high right atrium or when delivered simultaneously at the high right atrium, midseptum, and coronary sinus.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Tratamento
18.
Am J Cardiol ; 78(12): 1433-6, 1996 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-8970422

RESUMO

Impairment of cardiac function in atrial fibrillation has been attributed to loss of atrial contraction and to a rapid ventricular rate. The results of this study suggest that irregularity of the ventricular rhythm, independent of the ventricular rate, may also contribute to impairment of cardiac function during atrial fibrillation.


Assuntos
Fibrilação Atrial/fisiopatologia , Débito Cardíaco/fisiologia , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiologia , Pressão Propulsora Pulmonar/fisiologia , Volume Sistólico
19.
Am J Cardiol ; 84(10): 1266-8, A9, 1999 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-10569344

RESUMO

Among various electrocardiographic variables, the QRS duration in V2 was found to be the best discriminator of outcome in patients undergoing radiofrequency catheter ablation of the right ventricular outflow tract tachycardia and/or bigeminy. If the QRS duration is <160 ms in lead V2, the probability of successful ablation is lower than if the QRS duration is longer.


Assuntos
Ablação por Cateter , Eletrocardiografia , Taquicardia/diagnóstico , Taquicardia/terapia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/terapia , Adulto , Feminino , Sistema de Condução Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA