Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Dig Endosc ; 33(7): 1139-1145, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33284467

RESUMO

BACKGROUND: Long-term placement of lumen apposing metal stents (LAMS) with high lumen apposing force may result in adverse events. The aim of the current study was to assess the long-term efficacy and safety of a self-approximating LAMS with lower lumen apposing force for endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) and -gallbladder drainage (EUS-GBD). METHODS: Five Asian institutions participated in this study. Consecutive patients suffering from obstructive jaundice with failed ERCP or acute cholecystitis that were at high risk for cholecystectomy were recruited. We evaluated the technical and clinical success rates, adverse events rates, types of interventions through the stent and the patency profile. RESULTS: From June 2017 to Oct 2018, a total of 53 patients received EUS-CDS (26) and EUS-GBD (27). The technical and clinical success rates were similar between the two groups (88.5% vs 88.9%, P = 1 and 88.5% vs 88.9%, P = 1 respectively). The differences in 30-day mortality rates [2 (7.7%) vs 2 (7.7%), P = 1] and adverse events [3 (11.5%) vs 3 (11.5%), P = 1] did not reach significance. Regarding long-term outcomes, two patients in each group suffered from adverse events (P = 1). One patient in the EUS-GBD group who was on direct oral anticoagulant suffered from stent induced bleeding. CONCLUSION: The self-approximating LAMS with lower lumen apposing force was effective and safe with a low risk of buried stent syndrome and bleeding in the longer term. The ClinicalTrials.gov Identifier was NCT03002051.


Assuntos
Drenagem , Vesícula Biliar , Ductos Biliares , Endossonografia , Vesícula Biliar/diagnóstico por imagem , Humanos , Estudos Prospectivos , Stents , Resultado do Tratamento
2.
Dig Endosc ; 32(3): 391-398, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31343773

RESUMO

BACKGROUND: A novel self-approximating lumen-apposing metallic stent (LAMS; Niti-S Spaxus, Taewoong Medical, Gyeonggi-do, Korea) has recently become available. The aim of the present study was to evaluate the outcomes for drainage of pancreatic fluid collections (PFC). METHODS: This was a prospective international multicentered study conducted in six high-volume institutions across Asia. Consecutive patients suffering from pancreatic pseudocyst or walled-off pancreatic necrosis (WOPN) requiring endoscopic ultrasonography-guided drainage were recruited. Outcomes included technical and clinical success, adverse events, procedural events, interventions through the stent and recurrence rates. RESULTS: Between August 2016 and November 2017, 59 patients were recruited to this study. Thirty-nine patients (66.1%) had WOPN and mean (SD) size of PFC was 11.5 (5.1) cm. Technical and clinical success rates were 100%. Mean (SD) procedural time was 35.0 (17.2) minutes. Sixteen-millimeter stents were used in 66.1% of the patients. Fifty-four sessions of necrosectomy were carried out with the stent in situ in 17 patients. Stent-related adverse event (AE) rate was 6.8%. Three patients (5.1%) suffered from bleeding after stenting and one required angiographic embolization. Two patients (3.4%) suffered from recurrence during a mean (SD) follow-up time of 325.6 (355.5) days. There were no differences in outcomes between those with pseudocysts or WOPN except for the duration of hospital stay (P = 0.012). CONCLUSION: Use of a self-approximating LAMS for drainage of PFC was safe and effective. Endoscopic necrosectomy could be carried out through the stent with ease. The device was associated with a low rate of stent-related AE.


Assuntos
Drenagem/instrumentação , Endoscopia/instrumentação , Pseudocisto Pancreático/cirurgia , Pancreatite Necrosante Aguda/cirurgia , Stents , Adulto , Endossonografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pseudocisto Pancreático/diagnóstico por imagem , Pancreatite Necrosante Aguda/diagnóstico por imagem , Estudos Prospectivos
3.
VideoGIE ; 8(2): 60-63, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36820262

RESUMO

Video 1Demonstration of the modified technique of peroral endoscopic myotomy in a small child with achalasia cardia wherein a standard gastroscope could not be used because of anatomical constraints.

4.
Endosc Int Open ; 7(11): E1371-E1378, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31673607

RESUMO

Background and aim Accurate estimation of the distance to the gastroesophageal junction (GEJ) through a tunnel during per oral endoscopic myotomy (POEM) is technically challenging. The methods currently employed are often insufficient, and resultant errors may lead to incomplete myotomy and/or prolonged procedure times. Our hypothesis states that the additional distance while traversing the tunnel is directly proportional to the widest esophageal diameter; and is calculated by the formula X = Y + CZ (X = distance to the GEJ through the tunnel, Y = distance to the GEJ through the lumen, Z = widest esophageal diameter, C = arithmetic constant). This study evaluates the validity and accuracy of this hypothesis. Patients and methods This was a prospective single-center study with 80 patients, 12 in the pilot group and 68 in the study group. In the pilot group, Y was recorded during esophagogastroduodenoscopy (EGD) before POEM, Z on barium swallow/contrast enhanced computed tomography (CECT), and X was measured during POEM. Using the formula, mean C (SD) was calculated. In the study group, 'C' was substituted in the equation to predict the GEJ distance through the tunnel (Xp) before POEM. The operator was blinded to Xp and recorded the true Xt during POEM. The correlation between Xp and Xt was calculated. Results In the pilot group, the mean distances (cm, SD) for X, Y, and Z were 42.58 (3.33), 39.83 (3.08), and 4.39 (1.16), respectively. The calculated mean C was 0.63 (0.11). In the study group, the mean distances (cm, SD) for Y, Z, Xp, and Xt were 40.45 (2.58), 4.99 (1.43), 43.57 (2.68), and 43.54 (2.78), respectively. The Xp and Xt values demonstrated a high correlation (r = 0.97, P  = 0.000). Conclusions Formula X = Y + CZ reliably predicts the GEJ distance through a tunnel during POEM. It is user friendly and requires no additional resources.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA