Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Echocardiography ; 38(3): 394-401, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33586263

RESUMO

BACKGROUND AND AIMS: Complications of bicuspid aortic valve commonly include aortic stenosis, aortic regurgitation, and ascending aortic dilation. The progression of these lesions is not well described. MATERIALS AND METHODS: We reviewed 249 bicuspid aortic valve patients with at least two echocardiograms from 2006 to 2016. Valve morphology (right-left or right-noncoronary cusp fusion) was confirmed by visual inspection, and aortic stenosis and regurgitation were quantified according to current guidelines; the ascending aorta was measured at end-systole 2-3 cm above the sinotubular junction. Annualized progression of stenosis, regurgitation, and aortic dilation from first to most recent echocardiogram were compared between right-left and right-nonfused valves using multivariable logistic regression to adjust for baseline differences in groups. RESULTS: Among 249 bicuspid aortic valve patients (mean age 47.6 ± 13.5 years, 66.3% male), 75.9% had right-left cusp fusion. At baseline, aortic stenosis was absent or mild in 80.3%; aortic regurgitation was absent or mild in 80.7%; and aortic diameters were 35.0 ± 5.7 mm (sinuses of Valsalva) and 37.4 ± 6.2 mm (ascending). Mean annualized decrease in aortic valve area was 0.07 cm2 /year, with 30% of bicuspid aortic valve patients progressing ≥0.1 cm2 /year. Aortic regurgitation progressed ≥1 grade in 37 patients. Mean annualized increase in ascending aorta diameter was 0.36 mm/year in right-left and 0.65 mm/year in right-nonbicuspid valves. CONCLUSIONS: In this serial echocardiographic study of bicuspid aortic valve patients, cusp orientation was not associated with progression of valve dysfunction. Right-noncoronary cusp fusion was associated with ascending aortic diameter progression.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Dilatação , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Catheter Cardiovasc Interv ; 94(1): 70-81, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30593731

RESUMO

OBJECTIVES: This updated meta-analysis evaluated outcomes with multi-vessel (MV-PCI) vs culprit lesion-only percutaneous coronary intervention (CL-PCI), in patients with acute myocardial infarction (AMI) complicated by cardiogenic shock (CS). BACKGROUND: There is considerable debate regarding the optimal revascularization strategy in patients with AMI and CS, particularly regarding management of non-culprit lesions. METHODS: Databases were searched for studies comparing MV-PCI and CL-PCI in patients with AMI and CS. The primary outcome of interest was short-term all-cause mortality. Secondary outcomes included long-term mortality, repeat revascularization and myocardial reinfarction. Safety outcomes were stroke, acute renal failure and major bleeding. Pooled odds ratios (OR) and 95% confidence intervals (CI) were estimated using random-effects models. RESULTS: Our meta-analysis consisting of 14 studies (13 observational, 1 RCT) involving 8,552 patients showed that in comparison to CL-PCI, MV-PCI was associated with similar short-term mortality (OR 1.14; 95% CI 0.9-1.43), as well as similar long-term mortality (OR 0.94; 95% CI 0.68-1.28). There was no significant difference in the risk of myocardial reinfarction (OR 1.19; 95% CI 0.76-1.86), or repeat revascularization (OR 0.79; 95% CI 0.41-1.55) between the two groups. Compared to CL-PCI, MV-PCI was associated with a similar risk of bleeding (OR 1.13; 95% CI 0.91-1.40) and stroke (OR 1.28; 95% CI 0.84-1.96), but a higher risk of developing renal failure (OR 1.32; 95% CI 1.05-1.65). CONCLUSIONS: Our meta-analysis suggests that there is a higher risk of renal failure with no additional benefit in efficacy outcomes with MV-PCI, compared to CL-PCI in patients with AMI and CS.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Choque Cardiogênico/etiologia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Recidiva , Medição de Risco , Fatores de Risco , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 91(2): 203-212, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471093

RESUMO

OBJECTIVES: This meta-analysis evaluated the effectiveness of hybrid coronary revascularization (HCR) compared to coronary artery bypass grafting (CABG) for the treatment of multivessel coronary artery disease (MVCAD). BACKGROUND: HCR involves a combination of surgical and percutaneous techniques, which in selected patients may present an alternative to conventional CABG. METHODS: Databases were searched through June 30, 2016, and studies comparing HCR with CABG for treatment of MVCAD were selected. We calculated summary odds ratios (ORs) and 95% CIs with the random-effects model. The primary outcome of interest was the occurrence of major adverse cardiac and cerebrovascular events (MACCE), defined as a composite of all cause mortality, myocardial infarction, and stroke. RESULTS: The analysis included 2,245 patients from 8 studies (1 randomized controlled trial and 7 observational studies). The risk of MACCE with HCR and CABG were 3.6% and 5.4%, respectively (OR, 0.53; 95% CI, 0.24-1.16). Compared to CABG group, patients in HCR group had similar risk of all cause mortality (OR, 0.85; 95% CI, 0.38-1.88), myocardial infarction (OR, 0.72; 95% CI, 0.31-1.64), stroke (OR, 0.53; 95% CI, 0.23-1.20), and repeat revascularization (OR, 1.28; 95% CI, 0.58-2.83). The need for postoperative blood transfusions (OR, 0.29; 95% CI, 0.14-0.59) and hospital stay (weighted mean difference -1.20 days; 95% CI -1.52 to -0.88 days) was significantly lower in the HCR group. CONCLUSION: HCR appears to be safe, and has similar outcomes when compared with conventional CABG. HCR can be a suitable alternative to conventional CABG in select patients with MVCAD. © 2017 Wiley Periodicals, Inc.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea , Tomada de Decisão Clínica , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Humanos , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Resultado do Tratamento
5.
Curr Cardiol Rep ; 20(4): 26, 2018 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-29520510

RESUMO

PURPOSE OF REVIEW: Variant angina, which is characterized by recurrent chest pain and transient ECG changes along with angiographic evidence of coronary artery spasm, generally has a favorable prognosis. However, episodes of ischemia caused by vasospasm may lead to potentially life-threatening ventricular arrhythmias and cardiac arrest, even in patients with no history of prior cardiac disease. This review describes the epidemiology, pathogenesis, clinical spectrum, and management of variant angina, as well as outcomes in patients who present with aborted sudden cardiac death (ASCD). RECENT FINDINGS: Contrary to prior opinions, evidence from recent observational studies indicate that patients with variant angina presenting with ASCD face a worse prognosis than those without this type of presentation. Predictors of ASCD include age, hypertension, hyperlipidemia, family history of sudden cardiac death, multi-vessel spasm, and left anterior descending artery spasm. Medical therapy alone with calcium channel blockers and nitrates may not be sufficiently protective in these patients and there is lack of concrete data on the optimal management strategy. Current guidelines recommend implantable cardiac defibrillator (ICD) therapy in patients who are survivors of cardiac arrest caused by ventricular fibrillation or unstable ventricular tachycardia after reversible causes are excluded, and should strongly be considered in these patients. Although medical therapy is absolutely imperative for patients with variant angina and a history of ASCD, ICD therapy in these patients is justified. Further large-scale studies are required to determine whether ICD therapy can improve survival in this high-risk group of patients.


Assuntos
Angina Pectoris Variante/complicações , Vasoespasmo Coronário/complicações , Morte Súbita Cardíaca/epidemiologia , Parada Cardíaca/prevenção & controle , Angina Pectoris Variante/diagnóstico , Bloqueadores dos Canais de Cálcio/uso terapêutico , Vasoespasmo Coronário/diagnóstico , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Humanos , Guias de Prática Clínica como Assunto , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia
6.
Curr Cardiol Rep ; 20(5): 28, 2018 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-29572680

RESUMO

PURPOSE OF REVIEW: This review describes the dynamic relationship between diabetes mellitus (DM) and coronary artery disease (CAD) with respect to different revascularization strategies and how angiographic tools such as the Synergy between PCI with Taxus and Cardiac Surgery (SYNTAX) score can supplement clinical decision-making. RECENT FINDINGS: The SYNTAX score characterizes the anatomical extent of CAD in terms of the number of lesions, functional importance, and complexity. Studies not limited to patients with DM suggest that percutaneous coronary intervention (PCI) is a reasonable alternative to coronary artery bypass grafting (CABG) in patients with low-medium SYNTAX scores, while patients with high SYNTAX scores should be revascularized with CABG if operable. Similar findings were also observed for diabetes patients with multivessel disease in retrospective pooled analysis. The SYNTAX II score combines anatomical and clinical risk to improve upon the decision regarding the optimal revascularization strategy. The SYNTAX II score can be applied to patients with DM. The SYNTAX scores provide guidance to clinicians faced with determining the optimal revascularization strategy in patients with DM and advanced CAD. Using a heart team approach, the information can be considered along with other factors that influence PCI or CABG risk.


Assuntos
Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Cardiomiopatias Diabéticas/mortalidade , Revascularização Miocárdica/métodos , Sistemas de Apoio a Decisões Clínicas , Cardiomiopatias Diabéticas/fisiopatologia , Cardiomiopatias Diabéticas/cirurgia , Humanos , Revascularização Miocárdica/mortalidade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 90(2): 205-212, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28112470

RESUMO

OBJECTIVES: Ascertaining risk of contrast induced acute kidney injury (CI-AKI) in ST-segment elevation myocardial infarction (STEMI) patients undergoing multi-vessel percutaneous coronary intervention (MV-PCI). BACKGROUND: Complete revascularization may improve outcomes in STEMI patients with multi-vessel disease. However, a practice of MV-PCI may be associated with a higher risk of CI-AKI. We aimed to evaluate the risk of CI-AKI in patients with STEMI and MV-PCI and examine the accuracy of a validated risk score. METHODS: We searched PubMed, Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from inception through August 31, 2016 for randomized studies comparing CI-AKI rates with MV-PCI and infarct-related artery (IRA) only PCI during index hospitalization. A random effects model was used to estimate the risk ratio (RR) and respective 95% confidence intervals (CI). We queried the Nationwide Inpatient Sample (NIS) to assess the ability of the Mehran risk score to accurately predict the incidence of CI-AKI in patients undergoing MV-PCI. RESULTS: Four randomized studies (N = 1,602) were included in the final analysis. The risk of CI-AKI was low and no difference was observed with MV-PCI (1.45%) compared with IRA-only (1.94%) (RR 0.73, 95% CI 0.34-1.57; P = 0.57). From 2009 to 2012, excluding shock, there were 11,454 MV-PCI for STEMI patients in the NIS. The Mehran risk score accurately discriminated 78% of the patients who developed CI-AKI in this cohort (c-statistic of 0.78, P = 0.002). CONCLUSIONS: MV-PCI in STEMI is not associated with a higher risk of CI-AKI and the Mehran risk score can identify patients at higher risk for this complication. © 2017 Wiley Periodicals, Inc.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/efeitos adversos , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/mortalidade , Idoso , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Bases de Dados Factuais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/mortalidade , Radiografia Intervencionista/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
8.
Catheter Cardiovasc Interv ; 90(3): 504-515, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28398671

RESUMO

OBJECTIVES: We performed a meta-analysis to evaluate the efficacy and safety of transcatheter aortic valve replacement (TAVR) in comparison to surgical aortic valve replacement (SAVR) in intermediate-risk patients. BACKGROUND: TAVR is an established treatment option in high-risk patients with severe aortic valve stenosis (AS). There are fewer data regarding efficacy of TAVR in intermediate-risk patients. METHODS: Databases were searched through April 30, 2016 for studies that compared TAVR with SAVR for the treatment of intermediate-risk patients with severe AS. We calculated summary risk ratios (RRs) and 95% confidence intervals (CIs) with the random-effects model. RESULTS: The analysis included 4,601 patients from 7 studies (2 randomized and 5 observational). There was no significant difference in all-cause mortality between the two groups after mean follow-up of 1.15 years [14.7% with TAVR vs 15.4% with SAVR; RR 0.93; 95% CI 0.77-1.12]. TAVR resulted in lower rates of acute kidney injury [number needed to treat (NNT) = 26], major bleeding (NNT = 4), and atrial-fibrillation (NNT = 6), but higher rates of major vascular complications [number needed to harm (NNH)= 18], and moderate/severe aortic regurgitation (NNH = 13). The rate of permanent-pacemaker implantation was significantly higher with TAVR in observational studies (RR 2.31; 95% CI 1.22-2.81), but not in RCTs (RR 1.21; 95% CI 0.93-1.56). No significant difference in the rate of stroke or myocardial infarction was observed. CONCLUSIONS: Our analysis of mid-term results showed that TAVR has similar clinical efficacy to SAVR in intermediate-risk patients with severe AS, and can be a suitable alternative to surgical valve replacement. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Razão de Chances , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
10.
Eur Heart J ; 36(35): 2373-80, 2015 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-26071599

RESUMO

AIMS: Evidence from randomized controlled trials (RCTs) evaluating possible benefits of endovascular therapy (EVT) for acute ischaemic stroke has shown conflicting results. The purpose of this meta-analysis was to systematically examine clinical outcomes in RCTs comparing the use of intravenous (IV) fibrinolysis alone to IV fibrinolysis plus EVT, for the treatment of acute ischaemic stroke. METHODS AND RESULTS: We selected English language RCTs, comparing EVT plus IV tissue-type plasminogen activator (tPA) (if eligible) with IV tPA alone in eligible patients for the treatment of acute ischaemic stroke. The primary endpoint was good functional outcome [modified Rankin Scale (mRS) of 0-2]. Other major endpoints of interest were all-cause mortality and symptomatic intracerebral haemorrhage (sICH). The meta-analysis included 8 RCTs that randomized 2423 patients with large-vessel, anterior-circulation stroke. EVT significantly improved the rate of functional independence (90-day mRS of 0-2) when compared with IV fibrinolysis [odds ratio (OR) 1.73, 95% confidence interval (CI) 1.18-2.53, number needed to treat (NNT) = 9.3]. The all-cause mortality was lower with EVT compared with the control group; however, the result did not reach statistical significance (OR 0.89, 95% CI 0.68-1.15). The rate of sICH was not higher with EVT (OR 1.07, 95% CI 0.73-1.56). Analyses from only the recent trials (reported in 2014-15) showed further benefit (OR of mRS 0-2: 2.42, 95% CI 1.91-3.08, NNT = 5) with similar safety results. CONCLUSION: In centres with advanced systems of stroke care, EVT significantly improved functional outcomes (without compromising safety) in patients with acute ischaemic stroke due to anterior circulation, large artery occlusion, compared with standard therapy.


Assuntos
Procedimentos Endovasculares/métodos , Acidente Vascular Cerebral/terapia , Fibrinolíticos/uso terapêutico , Humanos , Infusões Intravenosas , Ensaios Clínicos Controlados Aleatórios como Assunto , Terapia Trombolítica/métodos , Ativador de Plasminogênio Tecidual/uso terapêutico , Resultado do Tratamento
11.
Curr Cardiol Rep ; 17(2): 1, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25612925

RESUMO

A disparity between evidence and practice in the management of ischemic heart disease is frequently observed. Guideline adherence and clinical outcomes are influenced by system, provider, and patient factors. Recently, performance improvement measures for cardiovascular disease have gained a lot of popularity worldwide. These measures may facilitate the uptake of evidence-based recommendations and improve patient outcomes. While apparently valid as quality metrics, their impacts on clinical outcomes remain limited and are areas of further research. Several methods for optimizing performance have been instituted and essentially involve three different approaches­improvement in the reporting of data on guideline adherence, providing infrastructure and tools, and providing incentives to improve guideline adherence. Public reporting of quality metrics and "pay-for-performance" are some novel performance improvement tools. The impact of these approaches on patient outcomes will be pivotal in improving cardiovascular outcomes in the future.


Assuntos
Fidelidade a Diretrizes , Recursos em Saúde/normas , Isquemia Miocárdica/terapia , Medicina Baseada em Evidências , Recursos em Saúde/estatística & dados numéricos , Humanos , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/normas , Resultado do Tratamento
13.
Cardiovasc Revasc Med ; 61: 52-61, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37872022

RESUMO

BACKGROUND: Bivalirudin is an alternative accepted therapy to unfractionated heparin for patients with myocardial infarction (MI) undergoing percutaneous coronary intervention (PCI). We aimed in this meta-analysis to compare bivalirudin versus unfractionated heparin in patients with MI undergoing PCI. METHODS: We have screened PubMed/MEDLINE, Cochrane Library, and ClinicalTrials.gov (inception through January 8th, 2023) for randomized controlled trials (RCTs) evaluating bivalirudin versus unfractionated heparin in patients with MI undergoing PCI. The DerSimonian and Laird method was used for estimation of tau2 to calculate the risk ratio (RR) and 95 % confidence interval (CI). RESULTS: Ten RCTs with a total of 40,069 participants were included in our analysis. Bivalirudin as compared with unfractionated heparin was associated with significant decrease in major bleeding (RR 0.64 [0.52 to 0.79]; p < 0.01; I2 = 69 %) and cardiovascular mortality (RR 0.79 [0.67 to 0.92]; p < 0.01; I2 = 0 %). There was no significant difference between bivalirudin and unfractionated heparin groups in terms of major adverse cardiovascular events (RR 1.02 [0.91 to 1.14]; p = 0.73; I2 = 52 %), all-cause mortality (RR 0.89 [0.77 to 1.04]; p = 0.15; I2 = 23 %), MI (RR 1.02 [0.87 to 1.19]; p = 0.80; I2 = 36 %), stent thrombosis (RR 1.12 [0.52 to 2.40]; p = 0.77; I2 = 82 %), or stroke (RR 0.97 [0.73 to 1.29]; p = 0.85; I2 = 0 %). CONCLUSION: Our meta-analysis suggests that bivalirudin compared with unfractionated heparin in patients with MI undergoing PCI was associated with lower rates of major bleeding and cardiovascular mortality without a significant difference in major adverse cardiovascular events, all-cause mortality, MI, stroke, or stent thrombosis.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Trombose , Humanos , Heparina/efeitos adversos , Antitrombinas/efeitos adversos , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Hirudinas/efeitos adversos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Infarto do Miocárdio/complicações , Fragmentos de Peptídeos/efeitos adversos , Hemorragia/induzido quimicamente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Proteínas Recombinantes/efeitos adversos , Anticoagulantes/efeitos adversos
14.
BMJ Case Rep ; 16(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914173

RESUMO

Non-bacterial thrombotic endocarditis, characterised by sterile vegetations, is commonly caused by systemic lupus erythematosus and is known to be complicated with embolic cerebrovascular disease. Embolic myocardial infarction with non-bacterial thrombotic endocarditis is extremely rare. We report a case of ventricular fibrillation arrest from presumed coronary embolisation in non-bacterial thrombotic endocarditis. While there are no standardised guidelines on the management of embolic myocardial infarction in endocarditis, it requires a multidisciplinary approach unique for every encountered clinical scenario.


Assuntos
Embolia , Endocardite não Infecciosa , Endocardite , Parada Cardíaca , Infarto do Miocárdio , Humanos , Endocardite não Infecciosa/diagnóstico , Endocardite não Infecciosa/diagnóstico por imagem , Infarto do Miocárdio/complicações , Endocardite/complicações , Endocardite/diagnóstico , Parada Cardíaca/complicações , Embolia/complicações , Embolia/diagnóstico por imagem
15.
Cardiovasc Revasc Med ; 28S: 127-131, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33500228

RESUMO

BACKGROUND: Subacute total occlusion in the setting of a tortuous vessel can be a therapeutic challenge. we demonstrate a safe and successful approach to deploy drug eluting stent of this complex lesion by using angled microcatheter. CASE PRESENTATION: A 61-year-old male with multiple atherosclerotic risk factors diagnosed with NSTEMI secondary to subacute total occlusion of the mid right coronary artery (RCA) with collaterals filling from septal perforators arising from mid left anterior descending artery. Due to severe tortuosity of RCA, the wire inside of Corsair microcatheter kept directing away from the lumen. Therefore, Corsair was exchanged for 90-degree SuperCross™ angled microcatheter that was rotated to direct its opening towards the lumen. A Confianza pro 12 wire was used to puncture into the lumen from the subinitimal position. SuperCross™ microcatheter was advanced over the wire into the lumen and eventually drug eluting stents were deployed successfully. CONCLUSION: While facing subacute total occlusion with proximal end in a tortuous artery, SuperCross™ microcatheter assisted dissection reentry could be attempted after failure of antegrade wire escalation technique. LEARNING OBJECTIVE: Facilitate the use of SuperCross™ microcatheter assisted dissection reentry as a successful approach for subacute total occlusion in tortuous vessels.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária , Stents Farmacológicos , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Dissecação , Humanos , Masculino , Pessoa de Meia-Idade , Stents
16.
Artigo em Inglês | MEDLINE | ID: mdl-34234910

RESUMO

Vas deferens calcification is a chronic arterio-sclerotic process that develops over many years and is strongly associated with infertility. Incidental findings on imaging are the most common means of diagnosing this condition. We report a case of a 56-year man who likely has male factor infertility and was found to have bilateral vas deferens calcification on CT imaging. This was performed during pre-procedural workup for transcatheter aortic valve replacement (TAVR) for management of severe aortic stenosis (AS). The patient was also had severe calcific multi-vessel coronary artery disease requiring percutaneous coronary intervention with atherectomy. This case highlights a novel clinical association linking infertility with coronary and valvular heart disease. It is possible that this association exists in larger numbers than previously recognized. Closer monitoring of pelvic imaging for TAVR access planning in patients with severe AS may bring more cases to light.

17.
Acad Radiol ; 28(12): 1669-1674, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-32972842

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) procedural success relies heavily on volumetric reconstruction imaging, particularly ECG-gated multi-detector row computed tomography. We postulated that single examination using fast low-angle shot (FLASH) dual source CT scanning (DS-CTA) could provide lower dose than ECG-gated CTA while maintaining the image quality. METHODS: In this single-centre cohort study, all patients who underwent ECG-gated and FLASH DS-CTA were evaluated. Volumetric reconstructions were performed for both ECG-gated and FLASH DS-CTA to obtain nonsagittal views of the structures. ECG-gated cardiac CT was obtained to evaluate the aortic annular size while FLASH DS-CTA was obtained to examine the aortic and iliac vasculature as part of TAVR imaging protocol. We evaluated measures of aortic annulus, coronaries and sinus of Valsalva using ECG-gated and FLASH DS-CTA scanning protocols. Image quality assessments were performed using aortic root region-of-interest signal-to-noise ratio. RESULTS: A total of 130 patients (mean age 81.5 ± 9.2 years, 46.2% female, and 99.2% white) underwent both ECG-gated CT and FLASH DS-CTA. There were excellent correlations between aortic annular area (R2 = 0.934) and aortic annular perimeter (R2 = 0.923) measured by the two protocols. Only 2 (1.5%) patients had >10% difference between aortic annular measurements by ECG-gated and FLASH DS-CTA, while none of the patients had a >10% difference between aortic annular perimeter measured by ECG-gated and FLASH DS-CT scans. There was no significant difference in signal-to-noise ratio between the two methods (mean difference 13.4; 95% CI -2.1-28.8, p = 0.09). There was significantly lower radiation dose for FLASH DS-CTA than ECG-gated CT scan (mean dose-length product difference 404.38; 95% CI 328.9-479.87, p <0.001). The measurements by the two scans led to the same transcatheter valve size selection in majority of the 128 (98.5%) patients by balloon expandable valve sizing recommendations and 130 (100%) of patients by self-expanding valve sizing recommendations. CONCLUSION: Overall, FLASH DS-CTA and ECG-gated CT scans provided comparable image quality and aortic annular dimensions for pre-TAVR evaluation. DS-CTA additionally provided the necessary angiographic imaging of the aorta and peripheral access vessels while still maintaining a lower radiation dose. We propose that a single non-ECG gated FLASH DS-CTA could be utilized to provide all the necessary pre-TAVR imaging information without a gated CT scan.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Coortes , Angiografia por Tomografia Computadorizada , Eletrocardiografia , Feminino , Humanos , Masculino , Tomografia Computadorizada Multidetectores
18.
Cardiovasc Revasc Med ; 28S: 253-258, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32863191

RESUMO

We report 4 cases of post myocardial infarction complications due to the delay in presentation during COVID-19 era. We highlighted the need for auscultating the chest for early diagnosis. Through this case series, we urge to raise awareness among cardiac patients to access healthcare despite the fear of COVID-19.


Assuntos
COVID-19 , Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico , Pandemias , SARS-CoV-2
19.
Expert Rev Cardiovasc Ther ; 19(6): 565-574, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33896312

RESUMO

BACKGROUND: The change in practice of transcatheter aortic valve replacement (TAVR) to a minimalist approach is a debate. METHODS: Online database search for studies that compared the minimalist approach with the standard approach for TAVR were searched from inception through September 2020. We calculated pooled odds ratios (ORs) and 95% confidence intervals (CIs) using the fixed or random-effects model. RESULTS: A total of 9 studies with 2,880 TAVR patients (minimalist TAVR;1066 and standard TAVR; 1,814) were included. Compared to standard approach, there were no significant differences in in-hospital mortality, 30-day mortality, or hospital readmissions. However, there was a reduced risk of acute kidney injury (OR0.49;95%CI0.27-0.89), major bleeding (OR0.21;95%CI0.12-0.38) and major vascular complications (OR0.60,95%CI0.39-0.91) associated with the minimalist TAVR group. There was comparatively shorter hospital length of stay (mean difference -2.41;95%CI-2.99,-1.83) days, procedural time (mean difference -43.99;95%CI-67.25,-20.75) minutes, fluoroscopy time (mean difference -2.69;95%CI-3.44,-1.94) minutes and contrast volume (mean difference -26.98;95%CI-42.18,-11.79) ml in the minimalist TAVR group. CONCLUSIONS: This meta-analysis demonstrated potential benefits of the minimalist TAVR approach over the standard approach regarding some adverse clinical outcomes as well as procedural outcomes without significant differences in mortality or readmission rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/etiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Fluoroscopia , Hemorragia/etiologia , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Readmissão do Paciente , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Doenças Vasculares/etiologia
20.
Cardiovasc Revasc Med ; 21(4): 453-460, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31669113

RESUMO

BACKGROUND: TAVR is an established treatment option in high and intermediate-risk patients with severe AS. There is less data regarding the efficacy of TAVR in low-risk patients. This meta-analysis evaluated efficacy and safety outcomes of transcatheter aortic valve replacement (TAVR) in comparison to surgical aortic valve replacement (SAVR) in low-risk patients with severe aortic stenosis (AS). METHODS: Databases were searched for randomized controlled trials (RCTs) that compared TAVR with SAVR for the treatment of low-risk patients with severe AS. We calculated pooled odds ratios (ORs) and 95% confidence intervals (CIs) using the random-effects model. RESULTS: The final analysis included 2953 patients from 5 studies. Compared to SAVR, TAVR was associated with similar mid-term mortality [OR 0.67; 95% CI 0.37-1.21; p = 0.18], as well as similar short-term mortality [OR 0.51; 95% CI 0.24-1.11; p = 0.09]. Randomization to TAVR was associated with a reduced risk of developing acute kidney injury [OR 0.26; 95% CI 0.13-0.52; p < 0.001], short-term major bleeding [OR 0.27; 95% CI 0.12-0.60; p < 0.001] and new-onset atrial fibrillation [OR 0.17; 95% CI 0.14-0.21; p < 0.001]. However, TAVR was associated with a higher risk of requiring permanent pacemaker implantation [OR 4.25; 95% CI 1.86-9.73; p < 0.001]. There was no significant difference in the risk of myocardial infarction, stroke, endocarditis or aortic valve re-intervention between the two groups. CONCLUSIONS: Our meta-analysis showed that TAVR has similar clinical efficacy to SAVR, with a more favorable safety profile, in patients with severe AS who are at low-surgical risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Tomada de Decisão Clínica , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Seleção de Pacientes , Complicações Pós-Operatórias/mortalidade , Ensaios Clínicos Controlados Aleatórios como Assunto , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA