Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 76(5): 668-72, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20690154

RESUMO

OBJECTIVES: We aimed to assess the efficiency of a long hydrophilic sheath in reducing radial spasm for transradial approach. BACKGROUND: Despite a lower access site complication rate, cardiac catheterization using transradial approach is not widely used. Radial spasm is one of the main issues for transradial angiography and percutaneous interventions. We assumed that radial artery protection using a long hydrophilic-coated sheath would reduce radial spasm compared to a bare short sheath. METHODS: Three hundred and fifty one patients (pts) admitted for transradial coronary angiography ± percutaneous coronary interventions were randomly assigned to a long hydrophilic-coated or a short sheath (control group). Primary end point was the occurrence of a radial spasm defined by significant patient pain evaluated by scale score (>4) or significant catheter frictions during manipulation. Procedure failure, radial occlusion, and local complications were also assessed. RESULTS: Radial spasm was significantly reduced when using the long-coated compared to the short sheath in 7 (4%) vs. 32 pts (18%) P < 0.001. No difference was found regarding procedure failure respectively 1.2% vs. 0.6%, local complication 0.6% vs. 1.2%, and radial occlusion 3.5% vs. 3.5%. CONCLUSION: Radial artery protection using the long hydrophilic-coated sheath was efficient in the prevention of radial spasm for transradial approach. © 2010 Wiley-Liss, Inc.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Angiografia Coronária/efeitos adversos , Artéria Radial , Espasmo/prevenção & controle , Idoso , Angioplastia Coronária com Balão/instrumentação , Arteriopatias Oclusivas/etiologia , Cateterismo Cardíaco/instrumentação , Distribuição de Qui-Quadrado , Angiografia Coronária/instrumentação , Desenho de Equipamento , Feminino , França , Fricção , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Dor/prevenção & controle , Medição da Dor , Punções , Medição de Risco , Fatores de Risco , Espasmo/etiologia
2.
Eur Heart J ; 29(17): 2133-40, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18385120

RESUMO

AIMS: We evaluated the accuracy of 64-slice computed tomography (CT) to identify ischaemic aetiology of heart failure (IHF). METHODS AND RESULTS: Ninety-three consecutive patients in sinus rhythm with dilated cardiomyopathy but without suspicion of coronary artery disease (CAD) were enrolled when admitted for angiography. Accuracy of CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. IHF was defined as a significant stenosis on left main or proximal left anterior descending artery or two or more vessels. Forty-three out of 1395 segments (3%) were heavily calcified and excluded. CT correctly assessed 103 of 142 (73%) significant stenosis and identified 46 of 50 (92%) patients without and 42 of 43 (98%) patients with CAD, 60 of 62 (97%) patients without and 28 of 31 (90%) patients with IHF. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of CT for identifying CAD by segment was 96, 73, 99, 92, and 97%, respectively; by patient was 95, 98, 92, 91, and 98%, respectively; and for identifying IHF was 95, 90, 97, 93, and 95%, respectively. CONCLUSION: Non-invasive 64-slice CT assessment of the extent of CAD may offer a valid alternative to angiography for the diagnosis of IHF.


Assuntos
Estenose Coronária/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Calcinose/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/etiologia , Angiografia Coronária/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
J Heart Valve Dis ; 16(3): 216-24, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17578038

RESUMO

BACKGROUND AND AIM OF THE STUDY: The study aim was to compare, prospectively, the planimetry of aortic stenosis on 64-slice computed tomography (CT), with the area calculated by Doppler transthoracic echocardiography (TTE) in symptomatic patients evaluated before potential aortic valve replacement. METHODS: Fifty-two consecutive patients (27 males, 25 females; mean age 74 +/- 10 years) admitted to the authors' institution during 2005 were evaluated with 64-slice CT and Doppler TTE. The time interval between the two evaluations was 2 +/- 1 weeks. Planimetry of the anatomic orifice area (AOA) drawn on 64-slice CT was compared to the effective area determined by Doppler TTE by Bland and Altman analysis, and the anatomic area threshold value corresponding to a significant effective aortic stenosis (50.75 cm2) was determined by receiver operating characteristic (ROC) analysis. RESULTS: The aortic orifice area measured by 64-slice CT correlated well with the effective area (r = 0.76; p <0.0001), but was significantly greater, with a systematic overestimation (0.132 cm(2)) and a variability of 0.239 cm(2). There was good agreement between planimetry determined by two independent radiologists (difference = 0.002, variability = 0.115 cm(2)). ROC analysis showed that a threshold value of 0.95 cm(2) as measured by 64-slice CT planimetry identifies significant aortic stenosis with sensitivity, specificity, accuracy, positive and negative predictive values of 82%, 77%, 81%, 91% and 59%, respectively. CONCLUSION: 64-slice CT is a reproducible and reliable non-invasive method to evaluate aortic valve stenosis compared to the reference method of Doppler TTE. Indeed, the CT approach could replace the latter evaluation when measurements used in the continuity equation are inadequate.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Tomografia Computadorizada por Raios X/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
4.
Am J Cardiol ; 98(7): 871-6, 2006 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16996865

RESUMO

The present study assessed 64-slice computed tomographic accuracy to quantify minimal lumen area (MLA) and determine lesion severity in intermediate stenosis by angiography compared with intravascular ultrasound (IVUS). Sixty-four-slice computed tomography (CT) has been shown to be effective in coronary stenotic assessment by visual estimation compared with angiography. However, angiography is not an accurate gold standard for intermediate stenotic quantification compared with IVUS. Forty patients (54 lesions) with 30% to 70% coronary stenosis by angiography in a major coronary branch were included. All patients underwent quantitative angiography, retrospective electrocardiographically gated 64-slice CT (Siemens), and IVUS (40-MHz Atlantis; Boston Scientific). MLA was manually traced by 2 blinded and independent operators on 64-slice computed tomographic cross-sectional reconstruction and compared with IVUS MLA. A lesion was considered significant if the MLA was

Assuntos
Estenose Coronária/patologia , Vasos Coronários/patologia , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção , Angiografia Coronária , Eletrocardiografia , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Índice de Gravidade de Doença
5.
Am J Cardiol ; 96(4): 524-8, 2005 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16098305

RESUMO

We aimed to quantify ambiguous coronary stenosis using the minimal lumen area with 16-slice computed tomography compared with intravascular ultrasound. The sensitivity, specificity, and accuracy for significant lesion classification was 68%, 86%, and 78%, respectively. The correlation between intravascular ultrasound and CT minimal lumen area was r = 0.73 (p <0.001), and the 95% confidence interval for CT measurement was -72% to +56%.


Assuntos
Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Endossonografia , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia Coronária , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
6.
Am J Cardiol ; 92(7): 849-52, 2003 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-14516892

RESUMO

Nonsignificant coronary artery plaque rupture or erosion may be the origin of acute myocardial infarction (AMI). The aim of our study was to assess the ability of multislice computed tomography (MSCT) to detect coronary plaques responsible for near normal coronary angiography AMI. Eight patients with presentation of AMI and no significant coronary narrowing by angiography were enrolled. Two groups were defined: (1) true AMI and (2) myocarditis. MSCT was able to detect nonsignificant coronary soft plaques responsible for AMI and has provided information on plaque volume, eccentricity, and density. In patients with myocarditis, there was no evidence of plaque.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Doença da Artéria Coronariana/complicações , Eletrocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Miocardite/complicações , Miocardite/diagnóstico , Ultrassonografia de Intervenção
7.
Am J Cardiol ; 94(1): 99-104, 2004 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-15219516

RESUMO

We compared 16-slice computed tomography with intravascular ultrasound in the detection of unstable component characteristics of nonstenotic plaque responsible for acute coronary syndrome. Computed tomography accurately assessed plaque eccentricity, calcification, and remodeling, and intraplaque hypodensity correlated with intravascular ultrasound echolucent area.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
8.
EuroIntervention ; 6(6): 717-21, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21205594

RESUMO

AIMS: Conventional quantitative coronary angiography approaches are limited to quantify complex aorto-ostial stenosis. Multislice CT was able to detect and classify coronary plaques, compared with intravascular ultrasound (IVUS). The aim of the present study was to determine the accuracy of multislice computed tomography (CT) in addition to conventional angiography to identify aorto-ostial coronary stenosis characteristics before revascularisation. METHODS AND RESULTS: Patients with coronary ostial stenosis were selected for the study. All patients had selective coronary angiography and retrospectively ECG-gated multislice CT (Siemens AG, Munich, Germany). IVUS was performed in patients with ambiguous ostial stenosis revealed by angiography. Forty significant aorto-ostial lesions (38 patients) were analysed by two independent observers in comparison with an expert consensus blinded or not to the coronary CT data sets. Using CT in addition to angiography permitted observers to obtain a strong agreement for assessment of calcified lesions (kappa value 0.75), a good agreement for aortic plaques location and ideal stent position in aorto-ostial coronary stenosis. CONCLUSIONS: This study shows that CT associated with an angiogram allows a better identification of aorto-ostial plaques morphology and ideal stent position in aorto-ostial coronary stenosis before angioplasty.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Eletrocardiografia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Stents , Ultrassonografia de Intervenção
10.
J Thorac Cardiovasc Surg ; 140(1): 73-9, 79.e1-2, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19944433

RESUMO

OBJECTIVE: The aim of this study was to assess the angiographic results of the radial artery as a coronary bypass conduit at long term (>5 years). METHODS: Radial artery grafts were controlled in 202 patients at 10.1 years by conventional angiography (n = 79) and computed tomography (n = 123). Clinical or paraclinical evidence of ischemia was noted in 81 patients, whereas 121 patients were asymptomatic. Some 520 conduits were controlled: radial artery (n = 230), left internal thoracic artery (n = 190), right internal thoracic artery (n = 30), and veins (n = 70). Radial arteries were anastomosed to the right coronary (24%), marginal (58%), diagonal (16%), and left anterior descending (<1%) arteries, whereas left internal thoracic arteries were primarily anastomosed to the left anterior descending artery (95%). The mean number of antithrombotic and anti-anginal medications was 1.2 and 1.9 per patient, respectively. RESULTS: The ejection fraction was slightly decreased compared with its preoperative value (54% +/- 11% vs 57% +/- 9%; P = .009). Nine reoperations were required at 10.5 years for valve replacement (n = 8) and isolated bypass (n = 1). Percutaneous intervention was performed in 48 patients (24%) at 7.6 years on a graft (28%) or a native coronary artery (72%). The 10-year patency of radial artery grafts was 83%, which was lower than the patency of left internal thoracic arteries (95%, P < .001) and similar to the patency of right internal thoracic arteries (87%, P = .66) and veins (81%, P = .50). No medication seemed to influence radial artery graft patency (aspirin: P = .26; calcium blockers: P = .36). All graft patency was lower when clinical or paraclinical evidence of ischemia was present than in asymptomatic cases (83% vs 90% P = .02). The patency of left anterior descending grafts was higher than that of non-left anterior descending grafts (96% vs 82% P < .001). CONCLUSION: The radial artery-to-coronary bypass conduit provided a low coronary reoperation rate with an excellent patency (83%) up to 20 years postoperatively.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Oclusão de Enxerto Vascular/etiologia , Artéria Radial/transplante , Grau de Desobstrução Vascular , Idoso , Angioplastia Coronária com Balão , Fármacos Cardiovasculares/uso terapêutico , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Anastomose de Artéria Torácica Interna-Coronária/efeitos adversos , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Reoperação , Volume Sistólico , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
11.
Eur Radiol ; 17(2): 331-8, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16953372

RESUMO

The aim of the study was to determine the potential diagnostic value of contrast-enhanced echocardiogram (ECG)-gated multidetector computed tomography (MDCT) in the setting of suspected acute myocarditis compared with contrast-enhanced magnetic resonance imaging (MRI). The study group consisted of 12 consecutive patients admitted for suspected acute myocarditis less than 10 days after onset of symptoms. All patients had clinical, electrocardiographic signs, and laboratory findings consistent with the diagnosis. All patients but one (severe claustrophobia) underwent cardiac MRI using T1-weighted delayed-enhancement images after injection of gadolinium. ECG-gated MDCT was performed in all patients and included a first-pass contrast-enhanced acquisition and a delayed acquisition. MRI revealed abnormal focal or multifocal myocardial enhancement and confirmed the diagnosis in 11 patients. The first-pass MDCT acquisition showed homogenous left-ventricle contrast enhancement and absence of coronary stenosis in all patients. Delayed MDCT acquisition, performed 5 min later without reinjection of contrast medium revealed multiple areas of myocardial hyperenhancement in a focal or a multifocal pattern (six and six patients, respectively). Extent and location of hyperenhancement at MDCT correlated well with that observed at MR examination for all 11 patients evaluated by both techniques (r=0.9167, p=0.0004). These preliminary results show that ECG-gated MDCT could be a useful alternative noninvasive diagnostic test in the early phase of acute myocarditis.


Assuntos
Eletrocardiografia , Imageamento por Ressonância Magnética , Miocardite/diagnóstico por imagem , Miocardite/patologia , Tomografia Computadorizada por Raios X , Doença Aguda , Adolescente , Adulto , Análise de Variância , Proteína C-Reativa/metabolismo , Meios de Contraste , Creatina Quinase/sangue , Feminino , Seguimentos , Gadolínio DTPA , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Projetos de Pesquisa , Sensibilidade e Especificidade , Fatores de Tempo , Troponina I/sangue
12.
Ann Thorac Surg ; 83(6): 2098-102, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17532406

RESUMO

BACKGROUND: The internal thoracic artery (ITA) is considered to be the conduit of choice for coronary artery bypass grafting surgery (CABG). In triple-vessel-disease patients, CABG can be performed exclusively using both ITAs in a Y fashion with multiple sequential side-to-side coronary anastomoses. The aim of this prospective study was to evaluate by early postoperative angiographic control, the patency and particularly the quality of ITA grafts and coronary anastomoses in this configuration. METHODS: Between October 2002 and October 2003, 92 triple-vessel-disease patients underwent CABG with this technique and consented to immediate postoperative angiographic control. The right ITA was divided at its origin and connected to the in-situ left ITA (ITA-Y anastomosis). The left ITA was anastomosed to anterior coronary arteries and the right ITA was anastomosed to lateral and inferior coronary arteries, for a total of 374 coronary anastomoses (4.1 anastomoses per patient; range, 3 to 6). RESULTS: There was 1 hospital death by septic shock. Two patients were reoperated on for superficial wound infection. There was no postoperative myocardial infarction or stroke. On postoperative angiograms, all ITA-Y (92) and ITA-coronary anastomoses (374) were patent. Competition of flow in right ITA to the moderately stenosed right coronary artery was observed in 9 patients, and there were 4 distal ITA-coronary stenoses, both without clinical consequences. CONCLUSIONS: In triple-vessel-disease patients, this procedure allows CABG without increasing operative risk. ITA-Y anastomoses and multiple sequential side-to-side ITA-coronary anastomoses are safe to perform and demonstrate excellent patency and quality in early postoperative angiographic control, particularly when coronary artery stenoses are significant (>70%).


Assuntos
Estenose Coronária/diagnóstico por imagem , Estenose Coronária/cirurgia , Anastomose de Artéria Torácica Interna-Coronária/métodos , Idoso , Anastomose Cirúrgica , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Artéria Torácica Interna/cirurgia , Pessoa de Meia-Idade , Estudos Prospectivos , Grau de Desobstrução Vascular
13.
J Am Coll Cardiol ; 49(11): 1178-85, 2007 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-17367662

RESUMO

OBJECTIVES: Early evaluation of myocardial viability in acute myocardial infarction is useful to guide therapy. Therefore, we assessed 64-slice computed tomography (CT) immediately after coronary angiography in this setting. BACKGROUND: Recent preliminary studies have shown the promising usefulness of late hyperenhancement multislice computed tomography (MSCT) for non-viability assessment. METHODS: Thirty-six patients admitted for a first acute myocardial infarction had a coronary angiogram early after admission followed by 64-slice CT without iodine reinjection. The 16 segments of the left ventricle depicted by the American Society of Echocardiography were graded: no, subendocardial, or transmural hyperenhancement. No or subendocardial hyperenhancement were expected to reflect viability. Two to 4 weeks later, the same segments' contractility was evaluated at rest. Low-dose dobutamine echocardiography was performed in case of akinetic segment at rest. RESULTS: Mean delay between coronary angiography and MSCT was 24 +/- 11 min (range 7 to 51 min). We compared 576 segments evaluated by each method. Agreement was noted for 560 segments (97%) and disagreement for 16 segments (3%). Thus, 64-slice CT after coronary angiography for an acute myocardial infarction had 98% sensitivity, 94% specificity, 97% accuracy, and 99% positive and 79% negative predictive values for detecting viable myocardial segments at a very early stage of an acute myocardial infarction. On a per-patient analysis, sensitivity, specificity, accuracy, and positive and negative predictive values were 92%, 100%, 94%, and 100% and 85%, respectively. CONCLUSIONS: A 64-slice CT after coronary angiography for an acute myocardial infarction is a promising method for early evaluation of viable myocardium.


Assuntos
Dobutamina , Ecocardiografia Doppler/métodos , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/métodos , Estudos de Coortes , Angiografia Coronária/métodos , Relação Dose-Resposta a Droga , Eletrocardiografia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Infarto do Miocárdio/terapia , Probabilidade , Medição de Risco , Sensibilidade e Especificidade , Volume Sistólico , Função Ventricular Esquerda/fisiologia
14.
Eur Heart J ; 27(9): 1054-60, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16569652

RESUMO

AIMS: In acute myocardial infarction (AMI), primary percutaneous transluminal angioplasty (PTCA) is the preferred option when it can be performed rapidly. Because of the limited access to high PTCA volume centres in some areas, it has been suggested that PTCA could be performed in low-volume centres on AMI patients. Little data exist on the validity of this strategy in modern era PTCA. METHODS AND RESULTS: The Greater Paris area comprises 11 million inhabitants and accounts for 18% of the French population. In 2001, the hospital agency of the Greater Paris area set up a registry of all PTCAs performed in this region. Data from 2001 and 2002 was analysed. Hospitals performing <400 PTCAs per year were classified as low-volume. A case-control analysis (propensity score) compared in-hospital mortality in low- and high-volume centres. A total of 37 848 angioplasty procedures were performed in 44 centres during the study period; 24.7% were performed in low-volume centres. A non-statistically significant trend towards reduced in-hospital mortality was noted in high-volume centres as opposed to low-volume centres: 2.01 vs. 2.42%, P = 0.057. In-hospital mortality rates were significantly different in the sub-group of emergency procedures: 6.75% in high- vs. 8.54% in low-volume centres, P = 0.028. No difference was noted between low- and high-volume centres in non-emergency procedures (0.62 vs. 0.62%, P = 0.99). CONCLUSION: In the era of modern stenting, a clear inverse relationship exists between hospital PTCA volume and in-hospital mortality after emergency procedures. Tolerance of low-volume thresholds for angioplasty centres with the purpose of providing primary PTCA in AMI should not be recommended, even in underserved areas.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Infarto do Miocárdio/terapia , Stents , Reanimação Cardiopulmonar/estatística & dados numéricos , Estenose Coronária/complicações , Estenose Coronária/mortalidade , Serviços Médicos de Emergência/estatística & dados numéricos , Feminino , Parada Cardíaca/etiologia , Parada Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Paris/epidemiologia , Sistema de Registros , Análise de Regressão , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade
15.
J Am Coll Cardiol ; 48(10): 1929-34, 2006 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-17112979

RESUMO

OBJECTIVES: The goal of this study was to evaluate the diagnostic accuracy of 64-slice computed tomography (CT) to identify coronary artery disease (CAD) in patients with complete left bundle branch block (LBBB). BACKGROUND: Left bundle branch block increases risk of cardiac mortality, and prognosis is primarily determined by the underlying coronary disease. Non-invasive stress tests have limited performance, and conventional coronary angiography (CCA) is usually required. METHODS: Sixty-six consecutive patients with complete LBBB and sinus rhythm admitted for CCA were enrolled. Computed tomography was performed 3 +/- 3.9 days before CCA. The accuracy of 64-slice CT to detect significant stenosis (>50% lumen narrowing) was compared with quantitative coronary angiography. All segments were analyzed regardless of image quality from coronary calcification or motion artifacts. Results were analyzed by patient and by coronary segment (990) using the American Heart Association 15-segment model. RESULTS: Lower heart rates were associated with improved image quality. Computed tomography correctly identified 35 of 37 (95%) patients without significant stenosis and 28 of 29 (97%) patients with significant stenosis on CCA. Computed tomography correctly assessed 68 of 94 (72%) significant stenosis. Overall, accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 64-slice CT for identifying CAD by patient was 95%, 97%, 95%, 93%, and 97%, respectively, and by segment was 97%, 72%, 99%, 91%, and 97%, respectively. CONCLUSIONS: In a routine clinical practice, 64-slice CT detects with excellent accuracy a significant CAD in patients with complete LBBB. A normal CT in this clinical setting is a robust tool to act as a filter and avoid invasive diagnostic procedures.


Assuntos
Bloqueio de Ramo/complicações , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia Coronária , Estenose Coronária/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
16.
Radiology ; 236(2): 485-9, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15972333

RESUMO

PURPOSE: To prospectively assess the accuracy of multi-detector row computed tomography (CT) in the prediction of infarct size after successful reperfusion of acute myocardial infarction (MI) by using single photon emission computed tomography (SPECT) images obtained 6 weeks later as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. A total of 34 patients (29 men and five women; mean age, 56 years +/- 13) underwent dual-phase 16-detector row CT within 3 days +/- 3 after successful reperfusion of acute MI. Iodinated contrast medium (1.5 mL per kilogram of body weight) was injected at a flow rate of 3.5 mL/sec. A first arterial phase acquisition was followed 5 minutes later by a late acquisition, without reinjection of contrast medium. A radiologist and a cardiologist used a 17-segment model in a blind analysis of images obtained during late acquisition. For each segment, presence of late defect or late enhancement was recorded. Findings were compared with SPECT studies analyzed by a nuclear medicine physician and a cardiologist 6 weeks after the acute event. CT defects were compared with SPECT defects on a segmental and per-patient basis. Mean number of segments with late defects on multi-detector row CT scans was compared with infarct size on SPECT images by using the t test. RESULTS: All patients had late enhancement in the infarcted myocardium. In 27 of 34 patients, a late defect surrounded by a subepicardial late enhancement was detected. Segments with late defect on CT scans were predictive of residual perfusion defects at 6-week follow-up, with sensitivity of 78%, specificity of 91%, and accuracy of 90%. On a per-patient basis, sensitivity was 93%, specificity was 100%, and accuracy was 94%. Mean number of segments with late defects on multi-detector row CT scans (ie, 3.1 segments) was not significantly different from infarct size on SPECT images (eg, 2.5 segments) (P = .2). CONCLUSION: Late defect on multi-detector row CT scans indicates residual perfusion SPECT defect and infarct size after successfully reperfused MI, with sensitivity of 93%, specificity of 100%, and accuracy of 94%.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Reperfusão Miocárdica , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
17.
Int J Cardiovasc Intervent ; 5(4): 206-10, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14630564

RESUMO

In order to reduce vascular complications, the authors assessed safety and feasability of a new percutaneous transluminal coronary angioplasty (PTCA) strategy consisting of direct stenting with 3000 i.u. heparin and immediate sheath removal. Predicting factors of vascular complications during PTCA include heparin dosages, sheath dwell time and use of anti-glycoprotein (GP) IIb/IIIa. A simplified PTCA with direct stenting technique may allow the use of very low doses of heparin without anti-GPIIb/IIIa in selected cases. From April 1999 to April 2000 all patients who underwent PTCA in the authors' center were screened. Exclusion criteria comprised a contraindication for direct stenting, primary PTCA for acute myocardial infarction (MI) and a TIMI (thrombolysis in myocardial infarction) grade zero flow. All other patients were included. They received 3000 i.u. heparin before direct stenting whatever their current anticoagulation and their weight. The sheath was immediately removed using manual compression. Out of 716 consecutive PTCA patients, 171 (24%) were enrolled in the study (198 sites). Complete protocol was achieved in 150 patients (88%). Activated clotting time during the procedure was 179 +/- 32 seconds. No subacute thrombosis or creatine kinase elevation was observed before discharge. Only two uncomplicated groin hematomas and two false aneurysms (one surgical repair) were noted. This study shows that direct stenting with 3000 iu heparin is safe. Immediate sheath removal can be performed with a low rate of major vascular complications.


Assuntos
Angioplastia Coronária com Balão/métodos , Heparina/administração & dosagem , Stents , Anticoagulantes/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Segurança
18.
Catheter Cardiovasc Interv ; 58(3): 285-91, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12594688

RESUMO

Clinical trials have shown that coronary stenting is associated with a high level of complications at the access site. Arterial sealing devices have proven their efficacy in obtaining immediate hemostasis after sheath removal, in allowing early ambulation, and in improving patient comfort. However, there is no report showing a reduction of local complications related to their use. The purpose of this multicenter study was to compare randomly the efficacy of Angio-Seal versus compression methods of hemostasis in reducing the rate of access site complications after coronary angioplasty in 612 selected patients with higher risk of local events satisfying at least one of the following high-risk criteria: age > 70, previous puncture at the same site, history of hypertension, treatment with ticlopidine at least 2 days before the procedure, use of abciximab, 8 Fr access, prolonged heparin treatment after the angioplasty, and use of lytics if fibrinogen > 1 g/l. Group A (n = 306) had immediate sheath removal, Angio-Seal implantation, and cessation of bed rest 4 hr after the intervention. Group B (n = 306) had sheath removal according to local practice and cessation of bed rest 6-18 hr after the hemostasis procedure, also according to local practice. Clinical follow-up was done at 1 hr, 4 hr, 24 hr, discharge, and 7 days and a systematic color flow duplex sonography was performed to confirm diagnosis of access site complication. In group A, device deployment and immediate hemostasis were obtained in, respectively, 96.8% and 87% of patients. Time to hemostasis was shorter in group A: 5 vs. 52 min (P < 0.001). Cessation of bed rest was dramatically reduced in group A (438 +/- 450 min) vs. group B (952 +/- 308 min; P < 0.001). The cumulative rate of complications, using a composite primary endpoint, at 7 days was significantly different between the two groups: 5.9% of group A patients and 18% of group B patients (P < 0.001). This difference was mainly due to the dramatic reduction of prolonged bleeding in group A patients. Angio-Seal device use in high-local-risk patients allows immediate sheath removal and hemostasis with a reduction of local event rate despite a higher level of anticoagulation, compared to regular compression techniques, directly related to a dramatic decrease of prolonged bleeding.


Assuntos
Angioplastia/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Cateteres de Demora/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Hemostasia Cirúrgica/instrumentação , Complicações Pós-Operatórias , Stents/efeitos adversos , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA