Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Small ; 20(9): e2304747, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37847909

RESUMO

All-solid-state lithium batteries (ASSLBs) are considered promising alternatives to current lithium-ion batteries that employ liquid electrolytes due to their high energy density and enhanced safety. Among various types of solid electrolytes, sulfide-based electrolytes are being actively studied, because they exhibit high ionic conductivity and high ductility, which enable good interfacial contacts in solid electrolytes without sintering at high temperatures. To improve the energy density of the sulfide-based ASSLBs, it is essential to increase the loading of active material in the composite cathode. In this study, the Ni-rich LiNix Coy Mn1-x-y O2 (NCM) materials are explored with different Ni content, particle size, and crystalline form to probe suitable cathode active materials for high-performance ASSLBs with high energy density. The results reveal that single-crystalline LiNi0.82 Co0.10 Mn0.08 O2 material with a small particle size exhibits the best cycling performance in the ASSLB assembled with a high mass loaded cathode (active mass loading: 26 mg cm-2 , areal capacity: 5.0 mAh cm-2 ) in terms of discharge capacity, capacity retention, and rate capability.

2.
Acta Neurochir (Wien) ; 166(1): 42, 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38280083

RESUMO

OBJECTIVE: The effectiveness of revascularization for complex aneurysms is well-established. This study aimed to describe the technical characteristics and clinical efficacy of intracranial-to-intracranial (IC-IC) bypass for the treatment of complex intracranial aneurysms. METHODS: We retrospectively reviewed all patients with aneurysms who underwent a preplanned combination of surgical or endovascular treatment and IC-IC bypass at our institution between January 2006 and September 2023. IC-IC bypass techniques included four strategies: type A (end-to-end reanastomosis), type B (end-to-side reimplantation), type C (in situ side-to-side anastomosis), and type D (IC-IC bypass with a graft vessel). RESULTS: During the study period, ten patients with aneurysms each underwent IC-IC bypass surgery. Aneurysms were located in the middle cerebral artery (60.0%), anterior temporal artery (10.0%), anterior cerebral artery (20.0%), and vertebral artery (10.0%). There were three saccular aneurysms (30.0%), two fusiform aneurysms (20.0%), one dissecting aneurysm (10.0%), and four pseudoaneurysms (40.0%). We performed the type A strategy on five patients (50.0%), type B on one (10.0%), type C on one (10.0%), and type D on three (30.0%). During a mean period of 68.3 months, good clinical outcomes (modified Rankin Scale score, 0-2) were observed in all patients. Follow-up angiography demonstrated complete aneurysmal obliteration in all patients and good bypass patency in nine of ten patients (90.0%). CONCLUSION: The treatment of complex aneurysms remains a challenge with conventional surgical or endovascular treatments. IC-IC bypass surgery is a useful technique, associated with favorable clinical outcomes, for treating complex aneurysms.


Assuntos
Revascularização Cerebral , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Revascularização Cerebral/métodos , Estudos Retrospectivos , Resultado do Tratamento , Artéria Cerebral Média/cirurgia
3.
J Am Chem Soc ; 145(47): 25815-25823, 2023 11 29.
Artigo em Inglês | MEDLINE | ID: mdl-37963186

RESUMO

Living systems create remarkable complexity from a limited repertoire of biological building blocks by controlling assembly dynamics at the molecular, cellular, and multicellular level. An open question is whether simplified synthetic cells can gain similar complex functionality by being driven away from equilibrium. Here, we describe a dynamic synthetic cell system assembled using artificial lipids that are responsive to both light and chemical stimuli. Irradiation of disordered aggregates of lipids leads to the spontaneous emergence of giant cell-like vesicles, which revert to aggregates when illumination is turned off. Under irradiation, the synthetic cell membranes can interact with chemical building blocks, remodeling their composition and forming new structures that prevent the membranes from undergoing retrograde aggregation processes. The remodeled light-responsive synthetic cells reversibly alter their shape under irradiation, transitioning from spheres to rodlike shapes, mimicking energy-dependent functions normally restricted to living materials. In the presence of noncovalently interacting multivalent polymers, light-driven shape changes can be used to trigger vesicle cross-linking, leading to the formation of functional synthetic tissues. By controlling light and chemical inputs, the stepwise, one-pot transformation of lipid aggregates to multivesicular synthetic tissues is feasible. Our results suggest a rationale for why even early protocells may have required and evolved simple mechanisms to harness environmental energy sources to coordinate hierarchical assembly processes.


Assuntos
Células Artificiais , Membrana Celular , Lipídeos
4.
Sensors (Basel) ; 23(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36992066

RESUMO

Lightning strikes can cause significant damage to critical infrastructure and pose a serious threat to public safety. To ensure the safety of facilities and investigate the causes of lightning accidents, we propose a cost-effective design method for a lightning current measuring instrument that uses a Rogowski coil and dual signal conditioning circuits to detect a wide range of lightning currents, ranging from hundreds of A to hundreds of kA. To implement the proposed lightning current measuring instrument, we design signal conditioning circuits and software capable of detecting and analyzing lightning currents from ±500 A to ±100 kA. By employing dual signal conditioning circuits, it offers the advantage of detecting a wide range of lightning currents compared to existing lightning current measuring instruments. The proposed instrument has the following features: First, the peak current, polarity, T1 (front time), T2 (time to half value), and Q (amount of energy of the lightning current) can be analyzed and measured with a fast sampling time of 380 ns. Second, it can distinguish whether a lightning current is induced or direct. Third, a built-in SD card is provided to save the detected lightning data. Finally, it provides Ethernet communication capability for remote monitoring. The performance of the proposed instrument is evaluated and validated by applying induced and direct lightning using a lightning current generator.

5.
Chemistry ; 28(30): e202200533, 2022 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-35302689

RESUMO

The photophysical behaviors of fluorescent molecules largely determine their major utility in biological studies. Despite their well-defined characteristics, classical fluorophores have often been challenged by their limited synthetic methodology and tunability in adjusting intrinsic optical properties. A novel heterocyclic core equipped with modular functional groups could offer the flexibility to control its photophysical properties with a minimum synthetic effort. By conducting a systematic analysis guided by quantum calculations, we proposed the furoindolizine-based molecular framework as a unique fluorescent platform capable of providing versatile photophysical properties with minimal structural modification. A broad tunability of furoindolizine derivatives' photophysical properties such as emission wavelength, Stokes shift, fluorescent brightness, and charge transfer characteristics was achieved through synergistic interaction between two functional moieties. Furthermore, this modular platform led to live-cell imaging probes with two distinct optical features simply by reorganizing a pair of functional moieties.


Assuntos
Corantes Fluorescentes , Corantes Fluorescentes/química , Ionóforos
6.
BMC Public Health ; 22(1): 476, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35272663

RESUMO

BACKGROUND: Participation in exercise, and dietary and nutritional intakes have an impact on the risk and prevalence of metabolic syndrome (MetS), but these effects may differ according to whether a person lives alone or in a multi-person household. We analyzed differences in physical activity (PA) levels and energy intake according to household-type and MetS presence among young adults, to investigate the relationships among these factors. METHODS: Data of 3974 young adults (aged > 19 years and < 40 years) were obtained from the Korean National Health and Nutrition Examination Survey (2016-2018). We analyzed PA levels (occupational and recreational PA, and transport) and energy intake (total, carbohydrate, protein, and fat). RESULTS: Logistic regression data showed that low PA levels and higher energy intake were associated with MetS incidence and its components in young adults, after adjusting for body mass index, smoking, household-type, and sex. Overall, there was no significant difference in PA level between the MetS and non-MetS group. The total energy intake was higher in the MetS than in the non-MetS group (p <  0.05). These results were similar to those found in multi-person households. In single-person households, the MetS group had significantly lower PA levels (p <  0.01) and total energy intake (p <  0.05) than the non-MetS group. CONCLUSIONS: We found significant association among low PA levels, high energy intake, and MetS components in young Korean adults, but with patterns differing according to household type. Energy intake was higher in young adults with than those without MetS, who lived in multi-person households, while young adults with MetS who lived alone had lower PA levels and lower energy intake than those without MetS. These findings highlight the need for different approaches of implementing PA and nutrition strategies according to the type of household in order to prevent MetS.


Assuntos
Síndrome Metabólica , Estudos Transversais , Ingestão de Energia , Exercício Físico , Humanos , Síndrome Metabólica/etiologia , Inquéritos Nutricionais , Prevalência , República da Coreia/epidemiologia , Fatores de Risco , Adulto Jovem
7.
Int J Mol Sci ; 23(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36555546

RESUMO

In this study, we propose the use of artificial synaptic transistors with coplanar-gate structures fabricated on paper substrates comprising biocompatible and low-cost potato-starch electrolyte and indium-gallium-zinc oxide (IGZO) channels. The electrical double layer (EDL) gating effect of potato-starch electrolytes enabled the emulation of biological synaptic plasticity. Frequency dependence measurements of capacitance using a metal-insulator-metal capacitor configuration showed a 1.27 µF/cm2 at a frequency of 10 Hz. Therefore, strong capacitive coupling was confirmed within the potato-starch electrolyte/IGZO channel interface owing to EDL formation because of internal proton migration. An electrical characteristics evaluation of the potato-starch EDL transistors through transfer and output curve resulted in counterclockwise hysteresis caused by proton migration in the electrolyte; the hysteresis window linearly increased with maximum gate voltage. A synaptic functionality evaluation with single-spike excitatory post-synaptic current (EPSC), paired-pulse facilitation (PPF), and multi-spike EPSC resulted in mimicking short-term synaptic plasticity and signal transmission in the biological neural network. Further, channel conductance modulation by repetitive presynaptic stimuli, comprising potentiation and depression pulses, enabled stable modulation of synaptic weights, thereby validating the long-term plasticity. Finally, recognition simulations on the Modified National Institute of Standards and Technology (MNIST) handwritten digit database yielded a 92% recognition rate, thereby demonstrating the applicability of the proposed synaptic device to the neuromorphic system.


Assuntos
Solanum tuberosum , Óxido de Zinco , Prótons , Transistores Eletrônicos , Óxido de Zinco/química , Eletrólitos/química
8.
Int J Mol Sci ; 23(9)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35563402

RESUMO

Renal fibrosis is an irreversible and progressive process that causes severe dysfunction in chronic kidney disease (CKD). The progression of CKD stages is highly associated with a gradual reduction in serum Klotho levels. We focused on Klotho protein as a key therapeutic factor against CKD. Urine-derived stem cells (UDSCs) have been identified as a novel stem cell source for kidney regeneration and CKD treatment because of their kidney tissue-specific origin. However, the relationship between UDSCs and Klotho in the kidneys is not yet known. In this study, we discovered that UDSCs were stem cells that expressed Klotho protein more strongly than other mesenchymal stem cells (MSCs). UDSCs also suppressed fibrosis by inhibiting transforming growth factor (TGF)-ß in HK-2 human renal proximal tubule cells in an in vitro model. Klotho siRNA silencing reduced the TGF-inhibiting ability of UDSCs. Here, we suggest an alternative cell source that can overcome the limitations of MSCs through the synergetic effect of the origin specificity of UDSCs and the anti-fibrotic effect of Klotho.


Assuntos
Rim , Proteínas Klotho , Insuficiência Renal Crônica , Células-Tronco , Feminino , Fibrose , Glucuronidase/metabolismo , Humanos , Rim/metabolismo , Rim/patologia , Masculino , Regeneração , Insuficiência Renal Crônica/metabolismo , Transdução de Sinais , Células-Tronco/metabolismo , Fator de Crescimento Transformador beta/metabolismo , Fator de Crescimento Transformador beta1/metabolismo , Urina
9.
Molecules ; 27(19)2022 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-36235052

RESUMO

Target protein degradation has emerged as a promising strategy for the discovery of novel therapeutics during the last decade. Proteolysis-targeting chimera (PROTAC) harnesses a cellular ubiquitin-dependent proteolysis system for the efficient degradation of a protein of interest. PROTAC consists of a target protein ligand and an E3 ligase ligand so that it enables the target protein degradation owing to the induced proximity with ubiquitin ligases. Although a great number of PROTACs has been developed so far using previously reported ligands of proteins for their degradation, E3 ligase ligands have been mostly limited to either CRBN or VHL ligands. Those PROTACs showed their limitation due to the cell type specific expression of E3 ligases and recently reported resistance toward PROTACs with CRBN ligands or VHL ligands. To overcome these hurdles, the discovery of various E3 ligase ligands has been spotlighted to improve the current PROTAC technology. This review focuses on currently reported E3 ligase ligands and their application in the development of PROTACs.


Assuntos
Ubiquitina-Proteína Ligases , Ubiquitina , Ligantes , Proteínas/metabolismo , Proteólise , Ubiquitina/metabolismo , Ubiquitina-Proteína Ligases/metabolismo
10.
Surg Endosc ; 35(3): 1156-1163, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32144557

RESUMO

BACKGROUND: Laparoscopic distal gastrectomy for early gastric cancer has been widely accepted, but laparoscopic total gastrectomy has still not gained popularity because of technical difficulty and unsolved safety issue. We conducted a single-arm multicenter phase II clinical trial to evaluate the safety and the feasibility of laparoscopic total gastrectomy for clinical stage I proximal gastric cancer in terms of postoperative morbidity and mortality in Korea. The secondary endpoint of this trial was comparison of surgical outcomes among the groups that received different methods of esophagojejunostomy (EJ). METHODS: The 160 patients of the full analysis set group were divided into three groups according to the method of EJ, the extracorporeal circular stapling group (EC; n = 45), the intracorporeal circular stapling group (IC; n = 64), and the intracorporeal linear stapling group (IL; n = 51). The clinicopathologic characteristics and the surgical outcomes were compared among these three groups. RESULTS: There were no significant differences in the early complication rates among the three groups (26.7% vs. 18.8% vs. 17.6%, EC vs. IC vs. IL; p = 0.516). The length of mini-laparotomy incision was significantly longer in the EC group than in the IC or IL group. The anastomosis time was significantly shorter in the EC group than in the IL group. The time to first flatus was significantly shorter in the IL group than in the EC group. The long-term complication rate was not significantly different among the three groups (4.4% vs. 12.7% vs. 7.8%; EC vs. IC vs. IL; p = 0.359), however, the long-term incidence of EJ stenosis in IC group (10.9%) was significantly higher than in EC (0%) and IL (2.0%) groups (p = 0.020). CONCLUSIONS: The extracorporeal circular stapling and the intracorporeal linear stapling were safe and feasible in laparoscopic total gastrectomy, however, intracorporeal circular stapling increased EJ stenosis.


Assuntos
Esofagostomia/métodos , Gastrectomia/métodos , Jejunostomia/métodos , Laparotomia/métodos , Neoplasias Gástricas/cirurgia , Idoso , Anastomose Cirúrgica/métodos , Constrição Patológica/etiologia , Esofagostomia/efeitos adversos , Feminino , Gastrectomia/efeitos adversos , Humanos , Jejunostomia/efeitos adversos , Laparoscopia/métodos , Laparotomia/efeitos adversos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , República da Coreia , Estudos Retrospectivos , Neoplasias Gástricas/patologia , Resultado do Tratamento
11.
Sensors (Basel) ; 20(8)2020 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-32325632

RESUMO

In this study, a low-cost surge current detection sensor (SCDS) that can measure high current surges using a low-current toroidal coil is proposed for maintenance of a surge protective device (SPD). The proposed SCDS is designed to display the predicted lifetime of the SPD based on the magnitude of surge current and number of surges. In addition, a method for measuring high surge current using a toroidal coil that can usually measure only low current is proposed. A lightning strike counter consists of a microcontroller with a low-power liquid crystal display (LCD) driver, 3 VDC lithium battery, and signal conditioning circuit that converts amplitude information of the surge current into duration information of a negative pulse to facilitate processing in the microcontroller. In this paper, we propose a software algorithm that can calculate the remaining lifetime of SPD based on the amplitude and number of surge currents. There is also an option to select the capacity of the surge protective device and the number of phase lines, allowing it to assess the predicted lifetime for various types of Class II SPDs. The proposed SCDS is measured as 7.2 µA from the battery power consumption test, and the service life is calculated to be 11.1 years. It meets the International Standard IEC62561-6 test conditions of the lightning strike counter and is expected to be useful in the maintenance of SPDs and lightning protection systems.

12.
Stroke ; 50(6): 1490-1496, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31043149

RESUMO

Background and Purpose- Based on its mechanism, the use of balloon guide catheters (BGCs) may be beneficial during endovascular treatment, regardless of the type of mechanical recanalization modality used-stent retriever thrombectomy or thrombaspiration. We evaluated whether the use of BGCs can be beneficial regardless of the first-line mechanical endovascular modality used. Methods- We retrospectively reviewed consecutive acute stroke patients who underwent stent retriever thrombectomy or thrombaspiration from the prospectively maintained registries of 17 stroke centers nationwide. Patients were assigned to the BGC or non-BGC group based on the use of BGCs during procedures. Endovascular and clinical outcomes were compared between the BGC and non-BGC groups. To adjust the influence of the type of first-line endovascular modality on successful recanalization and favorable outcome, multivariable analyses were also performed. Results- This study included a total of 955 patients. Stent retriever thrombectomy was used as the first-line modality in 526 patients (55.1%) and thrombaspiration in 429 (44.9%). BGC was used in 516 patients (54.0%; 61.2% of stent retriever thrombectomy patients; 45.2% of thrombaspiration patients). The successful recanalization rate was significantly higher in the BGC group compared with the non-BGC group (86.8% versus 74.7%, respectively; P<0.001). Furthermore, the first-pass recanalization rate was more frequent (37.0% versus 14.1%; P<0.001), and the number of device passes was fewer in the BGC group (2.5±1.9 versus 3.3±2.1; P<0.001). The procedural time was also shorter in the BGC group (54.3±27.4 versus 67.6±38.2; P<0.001). The use of BGC was an independent factor for successful recanalization (odds ratio, 2.18; 95% CI, 1.54-3.10; P<0.001) irrespective of the type of first-line endovascular modality used. The use of BGC was also an independent factor for a favorable outcome (odds ratio, 1.40; 95% CI, 1.02-1.92; P=0.038) irrespective of the type of first-line endovascular modality used. Conclusions- Regardless of the first-line mechanical endovascular modality used, the use of BGC in endovascular treatment was beneficial in terms of both recanalization success and functional outcome.


Assuntos
Angioplastia com Balão , Sistema de Registros , Acidente Vascular Cerebral/cirurgia , Trombectomia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia
13.
Gastric Cancer ; 22(1): 214-222, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30128720

RESUMO

BACKGROUND: With improved short-term surgical outcomes, laparoscopic distal gastrectomy has rapidly gained popularity. However, the safety and feasibility of laparoscopic total gastrectomy (LTG) has not yet been proven due to the difficulty of the technique. This single-arm prospective multi-center study was conducted to evaluate the use of LTG for clinical stage I gastric cancer. METHODS: Between October 2012 and January 2014, 170 patients with pathologically proven, clinical stage I gastric adenocarcinoma located at the proximal stomach were enrolled. Twenty-two experienced surgeons from 19 institutions participated in this clinical trial. The primary end point was the incidence of postoperative morbidity and mortality at postoperative 30 days. The severity of postoperative complications was categorized according to Clavien-Dindo classification, and the incidence of postoperative morbidity and mortality was compared with that in a historical control. RESULTS: Of the enrolled patients, 160 met criteria for inclusion in the full analysis set. Postoperative morbidity and mortality rates reached 20.6% (33/160) and 0.6% (1/160), respectively. Fifteen patients (9.4%) had grade III or higher complications, and three reoperations (1.9%) were performed. The incidence of morbidity after LTG in this trial did not significantly differ from that reported in a previous study for open total gastrectomy (18%). CONCLUSIONS: LTG performed by experienced surgeons showed acceptable postoperative morbidity and mortality for patients with clinical stage I gastric cancer.


Assuntos
Adenocarcinoma/cirurgia , Gastrectomia/métodos , Laparoscopia/métodos , Complicações Pós-Operatórias/epidemiologia , Neoplasias Gástricas/cirurgia , Adenocarcinoma/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Gastrectomia/mortalidade , Humanos , Incidência , Laparoscopia/mortalidade , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias Gástricas/mortalidade , Resultado do Tratamento , Adulto Jovem
14.
Neuroradiology ; 61(3): 265-274, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30415319

RESUMO

PURPOSE: White matter hyperintensities (WMH) and cerebral microbleeds (CMBs) are known to be associated with small vessel diseases (SVD) and neuroinflammation. The purpose was to investigate the relationship between CMBs and WMH in patients with systemic lupus erythematosus (SLE). METHODS: Thirty-one SLE patients with WMH and 27 SLE patients with normal brain MRI were compared. The presence, location, and grading of CMBs were assessed using susceptibility-weighted images. WMH volume was quantitatively measured. Clinical characteristics and serologic markers were compared. We also performed two separate subgroup analyses after (1) dividing WMH into inflammatory lesion vs. SVD subgroups and (2) dividing WMH into those with vs. without CMB subgroups. RESULTS: The WMH group showed more frequent CMBs than the normal MR group (p < 0.001). The WMH group showed higher SLE disease activity index, longer disease duration, and a higher incidence of antiphospholipid syndrome than the normal MR group (p = 0.02, 0.04, and 0.04, respectively). There was a moderate correlation between WMH volume and CMB grading (r = 0.49, p = 0.006). Within the WMH group, the inflammatory lesion subgroup showed more frequent CMBs and larger WMH volume than the SVD subgroup (p < 0.001 and 0.02, respectively). The WMH with CMB subgroup had larger WMH volume than the WMH without CMB subgroup (p = 0.004). CONCLUSION: In patients with SLE, CMBs could be related to large-volume WMH and inflammatory lesions. CMBs along with severe WMH could be used as an imaging biomarker of vasculitis in patients with SLE.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Lúpus Eritematoso Sistêmico/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Hemorragia Cerebral/patologia , Criança , Feminino , Humanos , Lúpus Eritematoso Sistêmico/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Substância Branca/patologia
15.
Sensors (Basel) ; 19(19)2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31590337

RESUMO

In this study, a new submersion detection sensor with improved reliability and stability is proposed. The new sensor uses two Resistance Temperature Detectors (RTDs) and operates on the thermal equilibrium principle. The submersion detection sensor controls two RTDs that maintain a constant temperature difference between them in the surrounding environment. The first RTD is used as a reference sensor to measure ambient temperature and the second RTD is supplied with higher current than the reference sensor for self-heating. When submerged, because the thermal conductivity and convective heat transfer coefficient of water are higher than that of air, the temperature difference between the two RTDs is lower in water than in air based on the thermal equilibrium principle. Under these conditions, a submersion detector with a signal conditioning circuit detects these temperature differences. The static performance of the proposed sensor was evaluated by checking whether malfunctions occurred at varying ambient temperatures, differing humidities, and when there was rainfall. In addition, the dynamic performance was evaluated using the response time at varying ambient air temperatures before submersion and with changing water temperatures after submersion, as a metric. The proposed submersion detection sensor is expected to find useful application in aircrafts, ships, and various other industrial fields.

16.
Stroke ; 49(9): 2088-2095, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30354993

RESUMO

Background and Purpose- Stent retriever (SR) thrombectomy has become the mainstay of treatment of acute intracranial large artery occlusion. However, it is still not much known about the optimal limit of SR attempts for favorable outcome. We evaluated whether a specific number of SR passes for futile recanalization can be determined. Methods- Patients who were treated with a SR as the first endovascular modality for their intracranial large artery occlusion in anterior circulation were retrospectively reviewed. The recanalization rate for each SR pass was calculated. The association between the number of SR passes and a patient's functional outcome was analyzed. Results- A total of 467 patients were included. Successful recanalization by SR alone was achieved in 82.2% of patients. Recanalization rates got sequentially lower as the number of passes increased, and the recanalization rate achievable by ≥5 passes of the SR was 5.5%. In a multivariable analysis, functional outcomes were more favorable in patients with 1 to 4 passes of the SR than in patients without recanalization (odds ratio [OR] was 8.06 for 1 pass; OR 7.78 for 2 passes; OR 6.10 for 3 passes; OR 6.57 for 4 passes; all P<0.001). However, the functional outcomes of patients with ≥5 passes were not significantly more favorable than found among patients without recanalization (OR 1.70 with 95% CI, 0.42-6.90 for 5 passes, P=0.455; OR 0.33 with 0.02-5.70, P=0.445 for ≥6 passes). Conclusions- The likelihood of successful recanalization got sequentially lower as the number of SR passes increased. Five or more passes of the SR became futile in terms of the recanalization rate and functional outcomes.


Assuntos
Procedimentos Endovasculares/estatística & dados numéricos , Acidente Vascular Cerebral/cirurgia , Trombectomia/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Infarto da Artéria Cerebral Média , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Retrospectivos , Acidente Vascular Cerebral/fisiopatologia , Falha de Tratamento
17.
Stroke ; 49(4): 958-964, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29581342

RESUMO

BACKGROUND AND PURPOSE: Effective rescue treatment has not yet been suggested in patients with mechanical thrombectomy (MT) failure. This study aimed to test whether rescue stenting (RS) improved clinical outcomes in MT-failed patients. METHODS: This is a retrospective analysis of the cohorts of the 16 comprehensive stroke centers between September 2010 and December 2015. We identified the patients who underwent MT but failed to recanalize intracranial internal carotid artery or middle cerebral artery M1 occlusion. Patients were dichotomized into 2 groups: patients with RS and without RS after MT failure. Clinical and laboratory findings and outcomes were compared between the 2 groups. It was tested whether RS is associated with functional outcome. RESULTS: MT failed in 148 (25.0%) of the 591 patients with internal carotid artery or middle cerebral artery M1 occlusion. Of these 148 patients, 48 received RS (RS group) and 100 were left without further treatment (no stenting group). Recanalization was successful in 64.6% (31 of 48 patients) of RS group. Compared with no stenting group, RS group showed a significantly higher rate of good outcome (modified Rankin Scale score, 0-2; 39.6% versus 22.0%; P=0.031) without increasing symptomatic intracranial hemorrhage (16.7% versus 20.0%; P=0.823) or mortality (12.5% versus 19.0%; P=0.360). Of the RS group, patients who had recanalization success had 54.8% of good outcome, which is comparable to that (55.4%) of recanalization success group with MT. RS remained independently associated with good outcome after adjustment of other factors (odds ratio, 3.393; 95% confidence interval, 1.192-9.655; P=0.022). Follow-up vascular imaging was available in the 23 (74.2%) of 31 patients with recanalization success with RS. The stent was patent in 20 (87.0%) of the 23 patients. Glycoprotein IIb/IIIa inhibitor was significantly associated with stent patency but not with symptomatic intracranial hemorrhage. CONCLUSIONS: RS was independently associated with good outcomes without increasing symptomatic intracranial hemorrhage or mortality. RS seemed considered in MT-failed internal carotid artery or middle cerebral artery M1 occlusion.


Assuntos
Artéria Carótida Interna/cirurgia , Procedimentos Endovasculares/métodos , Infarto da Artéria Cerebral Média/cirurgia , Stents , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral , Estudos de Coortes , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Hemorragias Intracranianas/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Tomografia Computadorizada por Raios X , Falha de Tratamento , Resultado do Tratamento
18.
J Am Chem Soc ; 140(3): 974-983, 2018 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-29240995

RESUMO

Fluorogenic bioorthogonal probes are ideal for fluorescent imaging in live cell conditions. By taking advantage of the dual functionality of tetrazine (Tz), as a bioorthogonal reaction unit as well as a fluorescence quencher, a fluorophore-Tz conjugate (FLTz) has been utilized for fluorescent live cell imaging via inverse electron-demand Diels-Alder (iEDDA) type bioorthogonal reactions. However, most FLTz strategies rely on a donor-acceptor-type energy transfer mechanism, which limits red-shifting of probes' emission wavelength without deterioration of the fluorescent turn-on/off ratio. To address this constraint, herein we present a monochromophoric design strategy for making a series of FLTzs spanning a broad range of emission colors. For the systematic comparison of design strategies with minimized structural differences, we selected indolizine-based emission-tunable Seoul-Fluor (SF) as a model fluorophore system. As a result, by inducing strong electronic coupling between Tz and π-conjugation systems of an indolizine core, we efficiently quench the fluorescence of SF-tetrazine conjugates (SFTzs) and achieved more than 1000-fold enhancement in fluorescence after iEDDA reaction with trans-cyclooctene (TCO). Importantly, we were able to develop a series of colorful SFTzs with a similar turn-on/off ratio regardless of their emission wavelength. The applicability as bioorthogonal probes was demonstrated with fluorescence bioimaging of innate microtubule and mitochondria using docetaxel-TCO and triphenylphosphonium-TCO in live cells without washing steps. We believe this study could provide new insight for the reliable and generally applicable molecular design strategy to develop bioorthogonal fluorogenic probes having an excellent turn-on ratio, regardless of their emission wavelength.


Assuntos
Corantes Fluorescentes/química , Compostos Heterocíclicos/química , Imagem Óptica/métodos , Linhagem Celular Tumoral , Reação de Cicloadição , Corantes Fluorescentes/síntese química , Células HeLa , Compostos Heterocíclicos/síntese química , Humanos , Mitocôndrias/ultraestrutura , Modelos Moleculares
19.
J Neurol Neurosurg Psychiatry ; 89(9): 903-909, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29519900

RESUMO

OBJECTIVE: To characterise the time window in which endovascular thrombectomy (EVT) is associated with good outcome, and to test the differential relationship between functional outcome and onset-to-reperfusion time (ORT), depending on collateral status. METHODS: This was a retrospective analysis of clinical and imaging data of 554 consecutive patients, who had recanalisation success by EVT for anterior circulation large artery occlusion, from the prospectively maintained registries of 16 comprehensive stroke centres between September 2010 and December 2015. The patients were dichotomised into good and poor collateral groups, based on CT angiography. We tested whether the likelihood of good outcome (modified Rankin Scale, 0-2) by ORT was different between two groups. RESULTS: ORT was 298 min±113 min (range, 81-665 min), and 84.5% of patients had good collaterals. Age, diabetes mellitus, previous infarction, National Institutes of Health Stroke Scale, good collaterals (OR 40.766; 95% CI 10.668 to 155.78; p<0.001) and ORT (OR 0.926 every 30 min delay; 95% CI 0.862 to 0.995; p=0.037) were independently associated with good outcome. The drop in likelihood of good outcome associated with longer ORT was significantly faster in poor collateral group (OR 0.305 for every 30 min; 95% CI 0.113 to 0.822) than in good collateral group (OR 0.926 for every 30 min; 95% CI 0.875 to 0.980). CONCLUSIONS: Earlier successful recanalisation was strongly associated with good outcome in poor collateral group; however, this association was weak during the tested time window in good collateral group. This suggests that the ORT window for good outcome can be adjusted according to collateral status.


Assuntos
Circulação Cerebrovascular/fisiologia , Circulação Colateral/fisiologia , Procedimentos Endovasculares , Trombose Intracraniana/terapia , Reperfusão , Trombectomia , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral , Feminino , Humanos , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , Fatores de Tempo , Resultado do Tratamento
20.
J Nanosci Nanotechnol ; 18(9): 6565-6569, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29677835

RESUMO

The detection and monitoring of colorless and odorless chemical warfare agents (CWAs) has become important due to the increasing threat of terrorist activities. To enhance the sensitivity and selectivity of CWAs a number of sensing materials have been developed, including the widely used polyvinylidene fluoride (PVDF). However, PVDF is limited by its low sensitivity and selectivity for many CWAs. In this study, polyhedral oligomeric silsesquioxane (POSS) was used as a sensing material for dimethyl methylphosphonate (DMMP) a simulant of sarin nerve gas. Sensitivity, selectivity, and reusability were investigated with an AT-cut 5 MHz quartz crystal microbalance. At room temperature, POSS exhibited a strong response for DMMP vapor at different concentrations from 20 ppm to 120 ppm leading to fast chemical adsorption and desorption. To investigate selectivity the volatile organic compounds (VOCs) ethanol, water, toluene, ACN, methanol, and n-hexane were tested at a fixed flow rate. Targeted VOCs showed lower responses than DMMP as measured with a quartz crystal microbalance (QCM) sensor, demonstrating the high selectivity of the method. POSS can be considered a potentially useful material for sensing nerve simulants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA