Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Magn Reson Med ; 92(6): 2535-2545, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39129199

RESUMO

PURPOSE: To implement rosette readout trajectories with compressed sensing reconstruction for fast and motion-robust CEST and magnetization transfer contrast imaging with inherent correction of B0 inhomogeneity. METHODS: A pulse sequence was developed for fast saturation transfer imaging using a stack of rosette trajectories with a higher sampling density near the k-space center. Each rosette lobe was segmented into two halves to generate dual-echo images. B0 inhomogeneities were estimated using the phase difference between the images and corrected subsequently. The rosette-based imaging was evaluated in comparison to a fully sampled Cartesian trajectory and demonstrated on CEST phantoms (creatine solutions and egg white) and healthy volunteers at 3 T. RESULTS: Compared with the conventional Cartesian acquisition, compressed sensing reconstructed rosette images provided image quality with overall higher contrast-to-noise ratio and significantly faster readout time. Accurate B0 map estimation was achieved from the rosette acquisition with a negligible bias of 0.01 Hz between the rosette and dual-echo Cartesian gradient echo B0 maps, using the latter as ground truth. The water-saturation spectra (Z-spectra) and amide proton transfer weighted signals obtained from the rosette-based sequence were well preserved compared with the fully sampled data, both in the phantom and human studies. CONCLUSIONS: Fast, motion-robust, and inherent B0-corrected CEST and magnetization transfer contrast imaging using rosette trajectories could improve subject comfort and compliance, contrast-to-noise ratio, and provide inherent B0 homogeneity information. This work is expected to significantly accelerate the translation of CEST-MRI into a robust, clinically viable approach.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Movimento (Física) , Compressão de Dados/métodos , Voluntários Saudáveis , Razão Sinal-Ruído , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Aumento da Imagem/métodos
2.
Magn Reson Med ; 92(6): 2641-2651, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39086185

RESUMO

PURPOSE: To evaluate the influence of the confounding factors, direct water saturation (DWS), and magnetization transfer contrast (MTC) effects on measured Z-spectra and amide proton transfer (APT) contrast in brain tumors. METHODS: High-grade glioma patients were scanned using an RF saturation-encoded 3D MR fingerprinting (MRF) sequence at 3 T. For MRF reconstruction, a recurrent neural network was designed to learn free water and semisolid macromolecule parameter mappings of the underlying multiple tissue properties from saturation-transfer MRF signals. The DWS spectra and MTC spectra were synthesized by solving Bloch-McConnell equations and evaluated in brain tumors. RESULTS: The dominant contribution to the saturation effect at 3.5 ppm was from DWS and MTC effects, but 25%-33% of the saturated signal in the gadolinium-enhancing tumor (13%-20% for normal tissue) was due to the APT effect. The APT# signal of the gadolinium-enhancing tumor was significantly higher than that of the normal-appearing white matter (10.1% vs. 8.3% at 1 µT and 11.2% vs. 7.8% at 1.5 µT). CONCLUSION: The RF saturation-encoded MRF allowed us to separate contributions to the saturation signal at 3.5 ppm in the Z-spectrum. Although free water and semisolid MTC are the main contributors, significant APT contrast between tumor and normal tissues was observed.


Assuntos
Neoplasias Encefálicas , Glioma , Imageamento por Ressonância Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Glioma/patologia , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Meios de Contraste/química , Imageamento Tridimensional , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Gadolínio/química
3.
NMR Biomed ; 37(1): e5042, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37767769

RESUMO

Magnetic resonance spectroscopic imaging (MRSI) provides information about the spatial distribution of metabolites in the brain. These metabolite maps can be valuable in diagnosing central nervous system pathology. However, MRSI generally suffers from a long acquisition time, poor spatial resolution, and a low metabolite signal-to-noise ratio (SNR). Ultrahigh field strengths (≥ 7 T) can benefit MRSI with an improved SNR and allow high-resolution metabolic mapping. Non-Cartesian spatial-spectral encoding techniques, such as rosette spectroscopic imaging, can efficiently sample spatial and temporal domains, which significantly reduces the imaging time and enables high-resolution metabolic mapping in a clinically relevant scan time. In the current study, high-resolution (in-plane resolution of 2 × 2 mm2 ) mapping of proton (1 H) metabolites in the human brain at 7 T, is demonstrated. Five healthy subjects participated in the study. Using a time-efficient rosette trajectory and short TR/TE free induction decay MRSI, high-resolution maps of 1 H metabolites were obtained in a clinically relevant imaging time (6 min). Suppression of the water signal was achieved with an optimized water suppression enhanced through T1 effects approach and lipid removal was performed using L2 -regularization in the postprocessing. Spatial distributions of N-acetyl-aspartate, total choline, creatine, N-acetyl-aspartyl glutamate, myo-inositol, and glutamate were generated with Cramer-Rao lower bounds of less than 20%.


Assuntos
Encéfalo , Prótons , Humanos , Espectroscopia de Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Imageamento por Ressonância Magnética/métodos , Mapeamento Encefálico/métodos , Água/metabolismo , Glutamatos/metabolismo
4.
NMR Biomed ; 36(5): e4872, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36349386

RESUMO

The purpose of the present study was to demonstrate a new sequence and determine the repeatability of simultaneous dynamic measurements of blood flow, venous oxygen saturation (SvO2 ), and relative perfusion (change from resting perfusion) in calf muscle during recovery from plantar flexion exercise. The feasibility of near simultaneous measurement of bio-energetic parameters was also demonstrated. A sequence was developed to simultaneously measure arterial blood flow using flow-encoded projection, SvO2 using susceptibility-based oximetry, and relative perfusion using arterial spin labeling in combination with dynamic plantar flexion exercise. The parameters were determined at rest and during recovery from single leg plantar flexion exercise. Test-retest repeatability was analyzed using Bland-Altman analysis and intraclass correlation coefficients (ICC). The mitochondrial capacity of skeletal muscle was also measured immediately afterwards with dynamic phosphorus magnetic resonance spectroscopy. Eight healthy subjects participated in the study for test-retest repeatability. Popliteal artery blood flow at rest was 1.79 ± 0.58 ml/s and increased to 11.18 ± 3.02 ml/s immediately after exercise. Popliteal vein SvO2 decreased to 45.93% ± 6.5% from a resting value of 70.46% ± 4.76% following exercise. Relative perfusion (change from rest value) was 51.83 ± 15.00 ml/100 g/min at the cessation of exercise. The recovery of blood flow and SvO2 was modeled as a single exponential with time constants of 38.03 ± 6.91 and 71.19 ± 14.53 s, respectively. All the measured parameters exhibited good repeatability with ICC ranging from 0.8 to 0.95. Bioenergetics measurements were within normal range, demonstrating the feasibility of near simultaneous measurement of hemodynamic and energetic parameters. Clinical feasibility was assessed with Barth syndrome patients, demonstrating reduced oxygen extraction from the blood and reduced mitochondrial oxidative capacity compared with healthy controls. The proposed protocol allows rapid imaging of multiple parameters in skeletal muscle that might be affected in disease.


Assuntos
Oximetria , Saturação de Oxigênio , Humanos , Fluxo Sanguíneo Regional/fisiologia , Hemodinâmica , Músculo Esquelético/fisiologia , Perfusão
5.
NMR Biomed ; 36(7): e4908, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36650646

RESUMO

Blood-brain barrier (BBB) dysfunction is associated with a number of central nervous system diseases. This study demonstrates the application of a novel noninvasive technique to measure the BBB permeability in the human brain at 7 T. The technique exploits the fact that, when tissue macromolecules are saturated by off-resonance RF pulse, the intravascular and the extravascular (tissue) water experience different magnetization transfer effects. This principle was combined with arterial spin labeling to distinguish between the intravascular and the tissue water, and was used to calculate perfusion, water extraction fraction (E), and BBB permeability surface area product for water (PS). Simultaneous coregistered magnetization transfer ratio maps were also generated that can provide valuable additional information. Eighteen healthy volunteers (seven females), age = 27 ± 11 years and weight = 65 ± 9 kg, participated in the study. Average perfusion was 67 ± 5 and 29 ± 4 ml/100 g/min (p < 0.05); and E was 0.921 ± 0.025 and 0.962 ± 0.015 (p < 0.05) in the gray matter (GM) and the white matter (WM), respectively. PS was higher in the GM (171 ± 20 ml/100 g/min) compared with the WM (95 ± 18 ml/100 g/min) (p < 0.05). The parameters exhibited good reliability with test re-test experiments. The sensitivity of this technique was demonstrated by 200 mg caffeine intake, which resulted in a decrease in the resting PS by ~31%.


Assuntos
Barreira Hematoencefálica , Imageamento por Ressonância Magnética , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Marcadores de Spin , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Água , Permeabilidade , Circulação Cerebrovascular/fisiologia
6.
Sci Rep ; 13(1): 8777, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37258697

RESUMO

MRI is a valuable diagnostic tool to investigate spinal cord (SC) pathology. SC MRI can benefit from the increased signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at ultra-high fields such as 7 T. However, SC MRI acquisitions with routine Cartesian readouts are prone to image artifacts caused by physiological motion. MRI acquisition techniques with non-Cartesian readouts such as rosette can help reduce motion artifacts. The purpose of this study was to demonstrate the feasibility of high-resolution SC imaging using rosette trajectory with magnetization transfer preparation (MT-prep) and compressed sensing (CS) at 7 T. Five healthy volunteers participated in the study. Images acquired with rosette readouts demonstrated reduced motion artifacts compared to the standard Cartesian readouts. The combination of multi-echo rosette-readout images improved the CNR by approximately 50% between the gray matter (GM) and white matter (WM) compared to single-echo images. MT-prep images showed excellent contrast between the GM and WM with magnetization transfer ratio (MTR) and cerebrospinal fluid normalized MT signal (MTCSF) = 0.12 ± 0.017 and 0.74 ± 0.013, respectively, for the GM; and 0.18 ± 0.011 and 0.58 ± 0.009, respectively, for the WM. Under-sampled acquisition using rosette readout with CS reconstruction demonstrated up to 6 times faster scans with comparable image quality as the fully-sampled acquisition.


Assuntos
Processamento de Imagem Assistida por Computador , Medula Espinal , Humanos , Processamento de Imagem Assistida por Computador/métodos , Estudos de Viabilidade , Medula Espinal/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
7.
Sci Rep ; 10(1): 6342, 2020 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-32286372

RESUMO

Impairments in oxygen delivery and consumption can lead to reduced muscle endurance and physical disability. Perfusion, a measure of microvascular blood flow, provides information on nutrient delivery. T2* provides information about relative tissue oxygenation. Changes in these parameters following stress, such as exercise, can yield important information about imbalance between delivery and consumption. In this study, we implemented novel golden angle radial MRI acquisition technique to simultaneously quantify muscle perfusion and T2* at 7T with improved temporal resolution, and demonstrated assessment of spatial and temporal changes in these parameters within calf muscles during recovery from plantar flexion exercise. Nine healthy subjects participated the studies. At rest, perfusion and T2* in gastrocnemius muscle group within calf muscle were 5 ± 2 mL/100 g/min and 21.1 ± 3 ms respectively. Then the subjects performed plantar flexion exercise producing a torque of ~8ft-lb. Immediately after the exercise, perfusion was elevated to 79.3 ± 9 mL/100 g/min and T2* was decreased by 6 ± 3%. The time constants for 50% perfusion and T2* recovery were 54.1 ± 10 s and 68.5 ± 7 s respectively. These results demonstrate successful simultaneous quantification of perfusion and T2* in skeletal muscle using the developed technique.


Assuntos
Exercício Físico , Músculo Esquelético/fisiologia , Consumo de Oxigênio , Fluxo Sanguíneo Regional , Adolescente , Adulto , Feminino , Humanos , Perna (Membro)/fisiologia , Imageamento por Ressonância Magnética , Masculino , Contração Muscular , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA