Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 122(12): 123606, 2019 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-30978050

RESUMO

We demonstrate quantum control of ^{9}Be^{+} ions directly implemented by an optical frequency comb. Based on numerical simulations of the relevant processes in ^{9}Be^{+} for different magnetic field regimes, we demonstrate a wide applicability when controlling the comb's spectral properties. We introduce a novel technique for the selective and efficient generation of a spectrally tailored narrow-bandwidth optical frequency comb near 313 nm. We experimentally demonstrate internal state control and internal-motional state coupling of ^{9}Be^{+} ions implemented by stimulated-Raman manipulation using a spectrally optimized optical frequency comb. Our pulsed laser approach is a key enabling step for the implementation of quantum logic and quantum information experiments in Penning traps.

3.
Biophys J ; 110(8): 1777-1788, 2016 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-27119638

RESUMO

Superwarfarins are modified analogs of warfarin with additional lipophilic aromatic rings, up to 100-fold greater potency, and longer biological half-lives. We hypothesized that increased hydrophobicity allowed interactions with amphiphilic membranes and modulation of biological responses. We find that superwarfarins brodifacoum and difenacoum increase lactate production and cell death in neuroblastoma cells. In contrast, neither causes changes in glioma cells that have higher cholesterol content. After choleterol depletion, lactate production was increased and cell viability was reduced. Drug-membrane interactions were examined by surface X-ray scattering using Langmuir monolayers of dipalmitoylphosphatidylcholine and/or cholesterol. Specular X-ray reflectivity data revealed that superwarfarins, but not warfarin, intercalate between dipalmitoylphosphatidylcholine molecules, whereas grazing incidence X-ray diffraction demonstrated changes in lateral crystalline order of the film. Neither agent showed significant interactions with monolayers containing >20% cholesterol. These findings demonstrate an affinity of superwarfarins to biomembranes and suggest that cellular responses to these agents are regulated by cholesterol content.


Assuntos
4-Hidroxicumarinas/toxicidade , Membrana Celular/efeitos dos fármacos , Membrana Celular/metabolismo , Colesterol/metabolismo , 1,2-Dipalmitoilfosfatidilcolina/química , 1,2-Dipalmitoilfosfatidilcolina/metabolismo , Animais , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Humanos , Ratos
5.
Opt Lett ; 40(11): 2469-72, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26030534

RESUMO

We perform a proof-of-principle demonstration of chemically specific standoff gas sensing, in which a coherent stimulated Raman signal is detected in the direction anticollinear to a two-color laser excitation beam traversing the target volume. The proposed geometry is intrinsically free space as it does not involve back-scattering (reflection) of the signal or excitation beams at or behind the target. A beam carrying an intense mid-IR femtosecond (fs) pulse and a parametrically generated picosecond (ps) UV Stokes pulse is fired in the forward direction. A fs filament, produced by the intense mid-IR pulse, emits a backward-propagating narrowband ps laser pulse at the 337 and 357 nm transitions of excited molecular nitrogen, thus supplying a counter-propagating Raman pump pulse. The scheme is linearly sensitive to species concentration and provides both transverse and longitudinal spatial resolution.

6.
Prenat Diagn ; 33(2): 109-15, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23280487

RESUMO

OBJECTIVE: This study aims to compare outcomes of active management of monochorionic diamniotic twin pregnancies complicated with severe intrauterine growth restriction (IUGR) of one twin before 24 weeks with continuous or intermittent absent or reversed end-diastolic flow (AREDF) in the umbilical artery, with or without twin-to-twin transfusion syndrome (TTTS). METHOD: This study is a retrospective comparison of 45 consecutive cases of severe selective IUGR (s-IUGR) defined as an estimated fetal weight at or below the fifth centile with a >25% weight discordance and AREDF in the umbilical artery before 24 weeks and 166 consecutive cases of TTTS stage III, with AREDF in the donor (TTTS3D) and also with s-IUGR. These were treated by either selective laser photocoagulation of chorionic vessels (SLPCV) or cord coagulation (CC). RESULTS: The 166 cases of TTTS3D were treated by SLPCV, whereas 23 and 22 cases of s-IUGR were treated by SLPCV and CC, respectively. Overall survival was 52.17% or 45.45% in s-IUGR treated by SLPCV or CC, respectively, and 48.49% in TTTS3D. The survival of appropriately grown for gestational age (AGA) twins following CC (90.9%) was higher than that following SLPCV in s-IUGR (74%) or in recipient twins of TTTS3D (55.42%) (p = 0.001). Survival of the IUGR twin was 30% and 41.56% with SLPCV in s-IUGR and TTTS3D, respectively. CONCLUSIONS: Active management of severe IUGR with AREDF in the umbilical artery seems beneficial. Survival rates with SLPCV were similar in s-IUGR and TTTS3D. However, there was a trend for higher survival rates in the AGA twin for CC. The choice of the technique should be driven by objective counseling on survival of both IUGR and AGA twins and therefore by the utility-based ethical values expressed by the pregnant woman.


Assuntos
Retardo do Crescimento Fetal/mortalidade , Transfusão Feto-Fetal/mortalidade , Gravidez de Gêmeos , Adulto , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Retardo do Crescimento Fetal/etiologia , Retardo do Crescimento Fetal/cirurgia , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/cirurgia , Humanos , Fotocoagulação a Laser , Gravidez , Segundo Trimestre da Gravidez , Estudos Retrospectivos , Taxa de Sobrevida , Gêmeos Monozigóticos , Ultrassonografia
7.
Opt Express ; 20(22): 24880-5, 2012 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-23187255

RESUMO

We report on a comprehensive theoretical and experimental analysis of the feed-forward method for external frequency stabilization of a continuous wave laser against a frequency comb. Application of the method to a distributed feedback diode laser at 1.55 µm allows line narrowing from 800 to 10 kHz, with frequency noise reduction by more than 2 decades up to a Fourier frequency of 100 kHz and a maximum control bandwidth of 0.8 MHz. The results are consistent with a relative phase fluctuation of 1.4 rad rms, as limited by uncompensated high-frequency noise of the slave laser.

8.
Opt Express ; 20(17): 18784-94, 2012 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-23038518

RESUMO

By combining tunable broadband pulse generation with the technique of nonlinear spectral compression we demonstrate a prototype scheme for highly selective detection of air molecules by backward stimulated Raman scattering. The experimental results allow to extrapolate the laser parameters required for standoff sensing based on the recently demonstrated backward atmospheric lasing.


Assuntos
Algoritmos , Atmosfera/análise , Atmosfera/química , Gases/análise , Lasers , Modelos Teóricos , Análise Espectral Raman/instrumentação , Análise Espectral Raman/métodos , Simulação por Computador , Espalhamento de Radiação
9.
Opt Lett ; 37(13): 2592-4, 2012 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-22743465

RESUMO

Wide-bandwidth phase lock between the tooth of a frequency comb and a CW extended-cavity diode laser at 1.55 µm is achieved by the use of an acousto-optical frequency shifter in a feed-forward configuration. The coherence properties of the comb are efficiently transferred to the CW laser, whose linewidth is narrowed down to the ∼10 KHz comb level. A maximum control bandwidth of ∼0.6 MHz has been experimentally achieved, limited by the transit time of the acoustic wave inside the frequency shifter.

10.
Opt Express ; 19(16): 15143-8, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21934875

RESUMO

We introduce a novel configuration for broadband, time-resolved CARS spectroscopy/microscopy in which pump, Stokes and probe pulses are all derived from a single femtosecond Yb:KYW laser. The 1-MHz repetition rate of the system allows very intense CARS signals to be obtained over short acquisition times, while a delayed probe pulse ensures an efficient non-resonant background suppression.


Assuntos
Análise Espectral Raman/métodos , Análise Espectral/métodos , Itérbio/química , Desenho de Equipamento , Lasers , Luz , Metanol/química , Óptica e Fotônica , Solventes , Fatores de Tempo , Água/química
11.
Opt Express ; 19(2): 1107-12, 2011 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-21263650

RESUMO

Multi-µJ narrow-bandwidth (≈ 10 cm(-1)) picosecond pulses, broadly tunable in the visible-UV range (320-520 nm), are generated by spectral compression of femtosecond pulses emitted by an amplified Ti:sapphire system. Such pulses provide the ideal Raman pump for broadband femtosecond stimulated Raman spectroscopy, as here demonstrated on a heme protein.


Assuntos
Heme/química , Lasers , Análise Espectral Raman/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Heme/análise
12.
Opt Express ; 19(18): 17520-7, 2011 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-21935118

RESUMO

This work presents a very simple yet effective way to obtain direct referencing of a quantum-cascade-laser at 4.3 µm to a near-IR frequency-comb. Precise tuning of the comb repetition-rate allows the quantum-cascade-laser to be scanned across absorption lines of a CO2 gaseous sample and line profiles to be acquired with extreme reproducibility and accuracy. By averaging over 50 acquisitions, line-centre frequencies are retrieved with an uncertainty of 30 kHz in a linear interaction regime. The extension of this methodology to other lines and molecules, by the use of widely tunable extended-cavity quantum-cascade-lasers, paves the way to a wide availability of high-quality and traceable spectroscopic data in the most crucial region for molecular detection and interrogation.

13.
Opt Lett ; 36(19): 3921-3, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21964142

RESUMO

The low-frequency tail of an octave-spanning supercontinuum (SC) generated by an Er:fiber comb is enhanced by a multipass Ho:YLF amplifier and used in a sum-frequency-generation scheme to obtain absolute referencing of a single-mode Tm-Ho:YAG laser tunable around 2.09 µm. By tuning the comb repetition frequency, the probing laser is scanned across the absorption lines of a CO(2) gas sample and highly accurate absorption profiles are measured. This approach can be readily scaled to any wavelength above ~2 µm.

14.
Opt Lett ; 35(15): 2645-7, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20680086

RESUMO

Phase-locked single-cycle transients with frequency components between 1 and 60THz and peak fields of up to 12MV/cm are generated as the idler wave of a parametric amplifier. To achieve broadband conversion in GaSe nonlinear crystals, we match the group velocities of signal and idler components. The influence of group-velocity dispersion is minimized by long-wavelength pumping at 1.18mum. Free-space electro-optic sampling monitors the multiterahertz waveforms with direct field resolution.

17.
Neuroradiol J ; 32(4): 309-314, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31018761

RESUMO

PURPOSE: Multiphase computed tomography angiography (MP-CTA) is an innovative imaging tool that can give those managing acute ischemic stroke temporal information on degree and extent of pial collateral arterial filling in the affected brain. We sought to estimate the incidence of false-positive or -negative evaluation of the carotid bifurcation or intracranial thrombus on single-phase CTA (SP-CTA) compared with MP-CTA. MATERIAL AND METHODS: A single-center, retrospective consecutive review was conducted of imaging and clinical records of 150 patients in two months who presented with neurological symptoms with a National Institutes of Health Stroke Scale score ≥ 2 and who received an MP-CTA as part of their investigative work-up. The cohort consisted of 52.3% male and 47.7% female patients. Median individual age was 68 years (interquartile range 60-79). Extracranial and intracranial vessel images of the initial early arterial phase were evaluated and compared with late arterial and early venous phase images. RESULTS: In the cohort of 150 patients, in three patients (2%) SP-CTA would have led to an incorrect diagnosis and management without MP-CTA-acquired source imaging. The three scenarios represented differentiating a carotid string sign from internal carotid artery occlusion, determining the appearance and extent of thrombus in carotid T-occlusion, and differentiating slow flow and contrast mixing-related artifacts from intraluminal thrombus. CONCLUSIONS: In addition to improving assessment of collateral circulation in acute stroke patients, MP-CTA is also useful in assessing specific flow-related scenarios for which SP-CTA may give spurious results.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Trombose Intracraniana/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Isquemia Encefálica/fisiopatologia , Angiografia Cerebral/métodos , Circulação Colateral/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Trombose Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/fisiopatologia
18.
Opt Express ; 16(16): 11727-34, 2008 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-18679442

RESUMO

An extremely compact and versatile near-infrared two-color femtosecond pump-probe spectroscopy apparatus based on an amplified Erfiber laser system is presented and applied to the characterization of the relaxation dynamics of single-wall carbon nanotubes with fundamental absorption in the 2 microm spectral region. By implementing a fast-scan technique, dynamics as long as 3 ps are acquired in 5 s with a relative sensitivity of 10(-4) and a temporal resolution below 100 fs at 2 microm.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Nanotubos de Carbono/química , Nanotubos de Carbono/ultraestrutura , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
19.
Opt Express ; 15(23): 15035-40, 2007 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-19550785

RESUMO

We report on the direct generation of broadband mid-IR pulses from an optical parametric amplifier. Several crystals with extended IR transparency, when pumped at 800 nm, display a broad phase-matching bandwidth around 1 mum, allowing for the generation of idler pulses spanning the 3-5 mum wavelength range. Using LiIO(3), we produce 2muJ pulses tunable in the 3-4 mum range with bandwidth supporting 30-fs transform-limited duration.

20.
Opt Express ; 15(14): 8884-91, 2007 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-19547226

RESUMO

We introduce a simple approach for the efficient generation of tunable narrow-bandwidth picosecond pulses synchronized to broadband femtosecond ones. Second harmonic generation in the presence of large group velocity mismatch between the interacting pulses transfers a large fraction of the energy of a broadband fundamental frequency pulse into a narrowband second harmonic one. Using a periodically poled stoichiometric lithium tantalate crystal coupled to an infrared optical parametric amplifier, we generated 200-nJ pulses with spectral width lower than 8.5 cm(-1) and tunability from 720 to 890 nm. Energy scaling and extension of the tuning range are straightforward.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA