Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chemistry ; : e202401403, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38818578

RESUMO

Our society largely relies on inorganic semiconductor devices which are, so far, fabricated using expensive and complex processes requiring ultra-high vacuum equipment. Here we report on the possibility of growing a p-n junction taking advantage of electrochemical processes based on the use of aqueous solutions. The growth of the junction has been carried out using the Electrochemical Atomic Layer Deposition (E-ALD) technique, which allowed to sequentially deposit two different semiconductors, CdS and Cu2S, on an Ag(111) substrate, in a single procedure. The growth process was monitored in situ by Surface X-Ray Diffraction (SXRD) and resulted in the fabrication of a thin double-layer structure with a high degree of crystallographic order and a well-defined interface. The high-performance electrical characteristics of the device were analysed ex-situ and show the characteristic feature of a diode.

2.
Molecules ; 27(10)2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35630562

RESUMO

Recently, the new updates in legislation about drinking water control and human health have increased the demand for novel electrochemical low-cost sensors, such as potentiometric ones. Nowadays, the determination of chloride ion in aqueous solutions has attracted great attention in several fields, from industrial processes to drinking water control. Indeed, chloride plays a crucial role in corrosion, also influencing the final taste of beverages, especially coffee. The main goal is to obtain devices suitable for continuous and real-time analysis. For these reasons, we investigated the possibility to develop an easy, low-cost potentiometric chloride sensor, able to perform analysis in aqueous mediums for long immersion time and reducing the need of periodic calibration. We realized a chloride ion selective electrode made of Ag/AgCl sintered pellet and we tested its response in model solutions compatible with drinking water. The sensor was able to produce a stable, reproducible, and accurate quantification of chloride in 900 s, without the need for a preliminary calibration test. This opens the route to potential applications of this sensor in continuous, in situ, and real time measurement of chloride ions in industrial processes, with a reduced need for periodic maintenance.


Assuntos
Cloretos , Água Potável , Cloretos/análise , Água Potável/análise , Eletrodos , Halogênios/análise , Humanos , Potenciometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA