Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Bioanalysis ; 10(9): 633-644, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29749254

RESUMO

AIM: Coproporphyrins (CP-I and CP-III) have been identified as possible biomarkers to predict human hepatic organic anion-transporting polypeptides-mediated-drug-interactions for a new drug entering clinical development. RESULTS: The method is applicable to quantify plasma CP-I and CP-III within 0.078-15.0 nM. The results identify and address a number of challenges encountered with porphyrin assays such as photodegradation and interferences. To overcome interferences from ubiquitous porphyrins, a surrogate matrix was used to prepare calibration standards. Quality controls were prepared in plasma and surrogate matrix to ensure parallelism between surrogate matrix and plasma. CONCLUSION: A robust UHPLC-MS/MS assay was developed and validated for CP-I and CP-III in plasma, and is currently applied to clinical studies to confirm suitability of Coproporphyrins as a potential substitute for drug-drug interaction study.


Assuntos
Biomarcadores Farmacológicos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Coproporfirinas/sangue , Transportadores de Ânions Orgânicos/metabolismo , Espectrometria de Massas em Tandem/métodos , Biomarcadores Farmacológicos/química , Coproporfirinas/química , Desenho de Fármacos , Interações Medicamentosas , Humanos , Transportadores de Ânions Orgânicos/química , Rifampina/sangue , Rifampina/química , Rosuvastatina Cálcica/sangue , Rosuvastatina Cálcica/química
2.
Artigo em Inglês | MEDLINE | ID: mdl-23542721

RESUMO

Clopidogrel is prescribed for the treatment of Acute Coronary Syndrome and recent myocardial infarction, recent stroke, or established peripheral arterial disease. A sensitive and reliable high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) assay was developed and validated to enable reliable quantification of four diastereomeric and chemically reactive thiol metabolites, two of which are pharmacologically active, in human plasma. The metabolites were stabilized by alkylation of their reactive thiol moieties with 2-bromo-3'-methoxyacetophenone (MPB). Following organic solvent mediated-protein precipitation in a 96-well plate format, chromatographic separation was achieved by gradient elution on an Ascentis Express RP-amide column. Chromatographic conditions were optimized to ensure separation of the four derivatized active metabolites. Derivatized metabolites and stable isotope-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The HPLC-MS/MS assay was validated over concentration ranges of 0.125-125 ng/mL for metabolites H1-H3 and 0.101-101 ng/mL for H4. Intra- and inter-assay precision values for replicate quality control samples were within 14.3% for all analytes during the assay validation. Mean quality control accuracy values were within ±6.3% of nominal values for all analytes. Assay recoveries were high (>79%). The four derivatized analytes were stable in human blood for at least 2 h at room temperature and on ice. The analytes were also stable in human plasma for at least 25 h at room temperature, 372 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of all four thiol metabolites in human plasma in support of a human pharmacokinetic study.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores da Agregação Plaquetária/farmacocinética , Espectrometria de Massas em Tandem/métodos , Ticlopidina/análogos & derivados , Clopidogrel , Humanos , Inibidores da Agregação Plaquetária/sangue , Ticlopidina/sangue , Ticlopidina/farmacocinética
3.
J Pharm Biomed Anal ; 70: 574-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22709607

RESUMO

Carvedilol is widely prescribed for the treatment of hypertension, heart failure and left ventricular dysfunction following myocardial infarction. A sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated to enable reliable and efficient bioanalysis of the (R)- and (S)-enantiomers of carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma. Following plasma extraction using supported liquid extraction (SLE) in a 96-well plate format, extracted samples were derivatized with 2,3,4,6-tetra-O-acetyl-ß-D-glucopyranosyl isothiocyanate (GITC). Chromatographic separation was achieved by gradient elution on an ACQUITY UPLC HSS T3 analytical column. The impact of several potentially interfering isobaric metabolites on the quantification of the 4'-hydroxyphenyl metabolite (R)- and (S)-enantiomers was minimized by implementation of a combination of chromatographic and mass spectrometric techniques. Derivatized analytes and stable-labeled internal standards were detected by positive ion electrospray tandem mass spectrometry. The assay was validated over concentration ranges of 0.200-100 ng/mL for (R)- and (S)-carvedilol and 0.0200-10.0 ng/mL for (R)- and (S)-4'-hydroxyphenyl carvedilol. Intra- and inter-assay precision values for replicate quality control samples were within 11.9% for all analytes during the assay validation. Mean quality control accuracy values were within ±9.4% of nominal values for all analytes. Assay recoveries were high (>76%) and internal standard normalized matrix effects were minimal. The four analytes were stable in human plasma for at least 24 h at room temperature, 89 days at -20 °C and -70 °C, and following at least five freeze-thaw cycles. The validated assay was successfully applied to the quantification of the (R)- and (S)-enantiomers of both carvedilol and its pharmacologically active 4'-hydroxyphenyl metabolite in human plasma in support of a human pharmacokinetic study.


Assuntos
Antagonistas Adrenérgicos/sangue , Antagonistas Adrenérgicos/farmacocinética , Carbazóis/sangue , Carbazóis/farmacocinética , Cromatografia de Fase Reversa , Propanolaminas/sangue , Propanolaminas/farmacocinética , Espectrometria de Massas em Tandem , Administração Oral , Antagonistas Adrenérgicos/administração & dosagem , Antagonistas Adrenérgicos/química , Biotransformação , Calibragem , Carbazóis/administração & dosagem , Carbazóis/química , Carvedilol , Cromatografia de Fase Reversa/normas , Estabilidade de Medicamentos , Humanos , Hidroxilação , Isomerismo , Isotiocianatos/química , Limite de Detecção , Modelos Lineares , Estrutura Molecular , Propanolaminas/administração & dosagem , Propanolaminas/química , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Espectrometria de Massas em Tandem/normas , Temperatura
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(5-6): 525-37, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-20083444

RESUMO

A sensitive method was developed and validated for the measurement of ixabepilone (BMS-247550, Ixempra) using a demethylated analogue of ixabepilone (BMS-212188) as an internal standard. A 0.050 mL portion of each plasma sample was extracted with 0.450 mL of acetonitrile containing the internal standard via protein precipitation. The supernatant was analyzed on a LC-MS/MS system. Chromatography was carried out on a 2.0 mm x 100 mm YMC ODS-AQ 3 microm column using an isocractic mobile phase consisting of acetonitrile:10 mM ammonium acetate, pH 5.0 (70:30, v/v) at a flow rate of 0.30 mL/min. The mass spectrometer was fitted with a TurboIonSpray source and operated in negative ionization mode. Detection of ixabepilone and BMS-212188 were accomplished using multiple reaction monitoring (MRM) of precursor>product ion pairs of m/z 505.2>405.2, and 492.1>392.1, respectively. The assay range was 2.00-500 ng/mL and was fitted to a 1/x(2) weighted quadratic regression model. Replicate sample analysis indicated that intra- and inter-day accuracy and precision are within +/-15.0%. The recovery of ixabepilone from 0.050 mL of plasma containing 5.00 and 400 ng/mL was greater than 94%. The method was demonstrated to be sensitive, selective and robust, and was successfully used to support clinical studies. This paper also discussed approaches used for resolving a curve splitting issue observed during quantitative analysis of ixabepilone in biological matrices. Finally, to adapt the methodology to pharmacokinetics of ixabepilone after oral administration, the potential interference of chemical degradants on the determination of ixabepilone was evaluated.


Assuntos
Cromatografia Líquida/métodos , Epotilonas/sangue , Espectrometria de Massas em Tandem/métodos , Moduladores de Tubulina/sangue , Epotilonas/administração & dosagem , Humanos , Sensibilidade e Especificidade , Moduladores de Tubulina/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA