1.
J Pediatr Endocrinol Metab ; 36(2): 216-222, 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36511758

RESUMO

OBJECTIVES: Hybrid closed loop systems (HCL) improve the management of type 1 diabetes (T1DM). T1DM adolescent patients represent a risk category also if they are in an automated insulin infusion delivery therapy. CASE PRESENTATION: We describe a series of four cases in which adolescent patients have adopted incorrect behaviours in the managing of HCL systems, challenging the algorithm skills. Two patients performed fabricated sensor calibrations. The other two did not perform pre-prandial insulin boluses correctly. Despite these behaviours, the algorithm corrected the glucose values in three out of four patients. Only in one case, where fabricated calibrations were too frequent, the automatic system failed to restore the glycemic balance. CONCLUSIONS: Fabricated calibrations seem to be more important than uncorrected insulin boluses to challenge the HCL systems.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes , Glicemia , Insulina , Automonitorização da Glicemia , Algoritmos , Sistemas de Infusão de Insulina