Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Ann Vasc Surg ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986839

RESUMO

OBJECTIVE: Fusion imaging systems have proved to reduce radiation exposure mostly in hybrid rooms but reports with mobile C-arms are few. The aim of this study was to analyse the impact of the Endonaut® navigation system on radiation exposure in endovascular aneurysm repair (EVAR) performed with mobile C-arms. METHODS: All patients undergoing EVAR and/or iliac branched devices implantation between January 2016 and August 2022 were included. All procedures were performed with a mobile C-arm (Siemens Avantic® or GE Elite® until March 2018, Siemens Cios Alpha® thereafter). The Endonaut® navigation system has been used since January 2021. Two groups were therefore compared : before (control group) and after the use of Endonaut®. Radiation data including Dose Area Product (DAP) values, Air Kerma (AK) and fluoroscopy time (FT) were collected retrospectively. RESULTS: Overall, 153 patients were included: control group (CGr), n = 121; Endonaut® group (EnGr), n = 32. No significant difference was found between the two groups regarding demographic data. DAP values were significantly lower in the EnGr (38 Gy.cm2 ± 24) vs. the CGr (76 Gy.cm2 ± 51) (p<.05) despite a significantly higher number of complex procedures such as iliac branched devices (p<.05). AK values were not significantly different between the EnGr and the CGr (196 mGy ± 114 vs. 209 mGy ± 138) as well as FT (33 minutes ± 18 vs. 33 minutes ± 16). Technical success was 97% (31/32) in the EnGr vs. 96% (116/121) in the CGr (p=.79). The volume of contrast media was significantly lower in the EnGr (94 cc ± 41) vs. the CGr (143 cc ± 66) (p<.05). CONCLUSION: In this study, the use of the Endonaut® angio-navigation system when performing EVAR with mobile C-arms led to a radiation dose reduction without compromising technical success or procedural time.

2.
Eur J Vasc Endovasc Surg ; 60(6): 925-931, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32893103

RESUMO

OBJECTIVE: Radiation dose in mesenteric stenting (MS) remains under evaluated. Yet, MS can lead to high levels of radiation mainly because lateral angulation is needed. The aim of this study was to evaluate the efficacy of an extra low dose protocol (ELDP) to reduce radiation exposure in MS. METHODS: From November 2017 to November 2019, all patients presenting with either acute or chronic atherosclerotic mesenteric ischaemia treated by antegrade MS using either fixed or mobile imaging systems in three university hospitals were included. In November 2018, an ELDP including ≤3 frames/s fluoroscopy and digital subtraction angiography (DSA) was introduced. Prospectively enrolled ELDP patients (Nov 2018-Nov 2019) were compared with retrospectively captured patients (Historical group, Nov 2017-Nov 2018). Radiation data including dose area product (DAP), cumulative air kerma (CAK), and fluoroscopy time (FT) were analysed. RESULTS: Overall, 46 patients (median age 73 years [63-72], 59% males) were included (ELDP group, n = 21; Historical group, n = 25). Thirty-three patients (72%) underwent MS in a hybrid room. Median DAP (ELDP group, 10 [4.7-26] Gy.cm2vs. Historical group, 45 [24-88] Gy.cm2, p = .002), median CAK (ELDP group, 170 [58-260] vs. Historical group, 262 [152-460], p = .037), and median number of DSA runs (ELDP group, 4 [1.5-5] vs. Historical group, 5.5 [3.7-5], p = .030) were statistically significantly lower in patients receiving the ELDP, whereas median FT (ELDP group, 16 min [11-23] vs. Historical group, 14 min [9-25], p = .71) and technical success (ELDP group, 95%; Historical group, 92%, p = .65) were not statistically significantly different between groups. CONCLUSION: MS exposes both patients and physicians to a high ionising radiation dose. Awareness of radiation safety and seeking dose reduction is paramount in these highly irradiating procedures. The use of ELDP significantly reduces radiation without compromising technical success.


Assuntos
Pessoal de Saúde , Oclusão Vascular Mesentérica/cirurgia , Exposição Ocupacional/prevenção & controle , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/métodos , Idoso , Angiografia Digital , Procedimentos Endovasculares , Feminino , Fluoroscopia , Humanos , Masculino , Artéria Mesentérica Superior , Oclusão Vascular Mesentérica/diagnóstico por imagem , Pessoa de Meia-Idade , Segurança do Paciente , Estudos Prospectivos , Implantação de Prótese , Doses de Radiação , Stents
3.
Ann Vasc Surg ; 64: 33-42, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31629123

RESUMO

BACKGROUND: The purpose of this study was to compare cryopreserved arterial allograft (CAA) to heparin-bonded prosthesis (HBP) in infragenicular bypasses for patients with chronic limb-threatening ischemia (CLTI). METHODS: This retrospective study took place in 2 university hospitals and included 41 consecutive patients treated for CLTI. In the absence of a suitable saphenous vein, an infragenicular bypass was performed using either CAA (24 cases) or HBP (17 cases). Kaplan-Meyer analysis compared primary and secondary patency and amputation-free survival rates. Binomial logistic regression analyzed risk factors for major amputation and thrombosis. RESULTS: The mean followup was 18.5 months (±14.3) in the CAA group, 17.6 (±6.1) in the HBP group. In the CAA group, primary and secondary patency rates at 12 months were 52% (±10.6) and 61% (±10.3), compared to 88% (±7.8) and 94% (±5.7) in the HBP group, respectively. The difference in patency rates was not statistically different (P = 0.27 and P = 0.28, respectively). The statistically significant factors of graft thrombosis were, a stage 4 from the WIfI classification (Wound Ischemia foot Infection) with a 6 times higher risk (P = 0.04), and a distal anastomosis on a leg artery with a 9 times higher risk of thrombosis (P = 0.03). Amputation-free survival rates at 18 months were similar between the groups (CCA: 75% (±9) versus HBP: 94% (±6), P = 0.11). Patients classified as WIfI stage 4 had 13 times higher odds to undergo major amputation than patients with WIfI stage 2 or 3 (95% CI, 1.16-160.93; P = 0.04). The intervention was longer in the CCA group of 74 min (278 min ± 86) compared to the HBP group (203 min ± 69). This difference was statistically significant (95% CI, 17.86-132.98), t(35) = 2.671, P = 0.01. CONCLUSIONS: CCA is not superior to HBP in infragenicular bypasses for CLTI, and may not be worth the extra cost and the longer operative duration.


Assuntos
Anticoagulantes/administração & dosagem , Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Materiais Revestidos Biocompatíveis , Heparina/administração & dosagem , Isquemia/cirurgia , Doença Arterial Periférica/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aloenxertos , Amputação Cirúrgica , Anticoagulantes/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Doença Crônica , Criopreservação , Feminino , França , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/cirurgia , Heparina/efeitos adversos , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Intervalo Livre de Progressão , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Trombose/etiologia , Trombose/fisiopatologia , Trombose/cirurgia , Fatores de Tempo , Grau de Desobstrução Vascular
4.
Ann Vasc Surg ; 58: 45-53.e1, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30738151

RESUMO

BACKGROUND: Fenestrated endovascular aortic repair (FEVAR) of complex aneurysm can require the coverage of polar renal artery. The aim of this study was to investigate the impact of the procedure on postoperative outcomes in patients with juxtarenal or thoracoabdominal aortic aneurysms. METHODS: Patients who had FEVAR for juxtarenal or type IV thoracoabdominal aortic aneurysm were retrospectively included between January 2010 and October 2017. The estimated glomerular filtration rate (eGFR) was recorded before and at 1 day, 7 days after surgery, and at the last follow-up. The occurrence of renal infarct was analyzed on the injected computed tomography scan images. RESULTS: Forty-three patients deemed at high-risk for open repair underwent FEVAR; 10 patients (23.3%) had polar renal artery coverage and were compared to patients without polar renal artery. The eGFR did not differ between the groups at 1 day and 7 days after FEVAR (69 vs 61.6 mL/mn/1.73 m2, P = 0.8708 and 68.4 mL/mn/1.73 m2 vs 68, P = 0.9440, respectively). For a median follow-up of 233 days, the eGFR at the latest follow-up was 38 mL/mn/1.73 m2 (21.8-56.3) in patients who had polar renal artery covered and 57 mL/mn/1.73 m2 (46.5-76) in patients without polar renal artery (P = 0.0748). Patients who had polar renal artery had a higher rate of postoperative kidney renal infarct (60% vs 21.2%, P = 0.0441). The proportion of vascular complications did not differ (30% vs 30.3%, P = 0.9999). No endoleak related to polar renal artery coverage was observed. The 30-day postoperative mortality was 4.7%. CONCLUSIONS: Polar renal artery coverage during FEVAR is not associated with critical renal and vascular short-term outcomes but could impact long-term renal function.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Rim/irrigação sanguínea , Artéria Renal/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Taxa de Filtração Glomerular , Humanos , Infarto/diagnóstico por imagem , Infarto/etiologia , Infarto/fisiopatologia , Masculino , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
5.
J Stroke Cerebrovasc Dis ; 28(1): 76-83, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30268367

RESUMO

INTRODUCTION: The neutrophil to lymphocyte ratio (NLR) and the platelet to lymphocyte ratio (PLR) have been identified as predictive factors in several cardiovascular diseases but their significance in patients with internal carotid artery (ICA) stenosis is still poorly known. The aim of this study was to determine the clinical significance of the preoperative NLR and PLR in patients with ICA stenosis undergoing carotid endarterectomy. MATERIAL AND METHODS: Consecutive patients who underwent carotid endarterectomy for ICA stenosis were retrospectively included (n = 270). The population was divided into 2 series of 4 groups based on the quartile values of the preoperative NLR and PLR: group Ia (NLR < 1.5), IIa (1.50 < NLR < 2.07), IIIa (2.07 < NLR < 2.95), IVa (NLR>2.95), and group Ib (PLR < 86.6), IIb (86.6 < PLR < 111.7), IIIb (111.7 < PLR < 148.3), IVb (PLR > 148.3). Clinical characteristics and 30-day postoperative outcomes were compared among the groups. RESULTS: One death (.4%) was reported during the 30-day postoperative period and the overall stroke and death rate was 1.5%. The proportion of patients with symptomatic ICA stenosis were significantly higher in group IVa compared to groups Ia, IIa, IIIa (64.2% vs 33.8%, 44.8% and 45.6%, respectively, P = .005), and higher in group IVb compared to groups Ib, IIb, IIIb (59.7% vs 47.1%, 35.8%, 45.6%, P = .051). No significant difference on 30-day postoperative all-cause complications was observed among the groups. CONCLUSIONS: A high preoperative NLR and PLR is significantly associated with symptomatic ICA stenosis. Further studies are required to determine their interest as predictors of postoperative outcomes in patients undergoing carotid endarterectomy.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas/sangue , Idoso , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/epidemiologia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Feminino , Humanos , Contagem de Linfócitos , Masculino , Neutrófilos , Contagem de Plaquetas , Complicações Pós-Operatórias/sangue , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/epidemiologia
7.
Angiology ; 72(6): 539-549, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32851875

RESUMO

Rupture of splenic artery aneurysms (SAAs) is associated with a high mortality rate. The aim of this study was to identify the features of SAAs. Tissue sections from SAAs were compared to nonaneurysmal splenic arteries using various stains. The presence of intraluminal thrombus (ILT), vascular smooth muscle cells (VSMCs), cluster of differentiation (CD)-68+ phagocytes, myeloperoxidase+ neutrophils, CD3+, and CD20+ adaptive immune cells were studied using immunofluorescence microscopy. Analysis of SAAs revealed the presence of atherosclerotic lesions, calcifications, and ILT. Splenic artery aneurysms were characterized by a profound vascular remodeling with a dramatic loss of VSMCs, elastin degradation, adventitial fibrosis associated with enhanced apoptosis, and increased matrix metalloproteinase 9 expression. We observed an infiltration of immune cells comprising macrophages, neutrophils, T, and B cells. The T and B cells were found in the adventitial layer of SAAs, but their organization into tertiary lymphoid organs was halted. We failed to detect germinal centers even in the most organized T/B cell follicles and these lymphoid clusters lacked lymphoid stromal cells. This detailed histopathological characterization of the vascular remodeling during SAA showed that lymphoid neogenesis was incomplete, suggesting that critical mediators of their development must be missing.


Assuntos
Aneurisma/imunologia , Aneurisma/patologia , Leucócitos/imunologia , Macrófagos/imunologia , Artéria Esplênica/imunologia , Artéria Esplênica/patologia , Remodelação Vascular , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma/metabolismo , Aneurisma/cirurgia , Apoptose , Linfócitos B/imunologia , Biomarcadores/análise , Feminino , Fibrose , Humanos , Macrófagos/química , Masculino , Pessoa de Meia-Idade , Neutrófilos/imunologia , Estudos Retrospectivos , Artéria Esplênica/química , Artéria Esplênica/cirurgia , Linfócitos T/imunologia
8.
Vasc Endovascular Surg ; 53(1): 5-11, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30021492

RESUMO

INTRODUCTION:: The predictive value of the platelet to lymphocyte ratio (PLR) has been demonstrated in several cardiovascular diseases. The aim of this study was to investigate the interest of the preoperative PLR as a predictor of 30-day postoperative outcome in patients with abdominal aortic aneurysm (AAA) undergoing open or endovascular surgical repair. MATERIAL AND METHODS:: Two hundred twenty-four consecutive patients with infrarenal AAA were retrospectively included and divided into 4 quartiles according to the value of the preoperative PLR: PLR < 91.5 (group I), 91.5 < PLR < 120.8 (group II), 120.8 < PLR < 163.3 (group III), and PLR > 163.3 (group IV). RESULTS:: The AAA diameter was similar among the groups (54.9 mm vs 58.6, 57.5, and 58.7 mm; P = .4655). The proportion of symptomatic AAA and the procedural characteristics did not differ. Patients from group I and IV had significantly higher rates of all-cause postoperative complications compared to group II and III (55.4% and 64.3% vs 39.3% and 46.4%, respectively; P = .0478). The all-cause mortality tended to be higher in group I and IV (7.1% and 8.9% vs 0% and 3.6%, respectively; P = .1305). CONCLUSION:: Extreme values of PLR are associated with a higher risk of complications following AAA surgical repair, suggesting its interest as a biomarker to evaluate the surgical risk.


Assuntos
Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/cirurgia , Plaquetas , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Linfócitos , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA