1.
J Acoust Soc Am ; 150(6): 4095, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34972282

RESUMO

Although X-Ray Computed Tomography (CT) is widely used for detecting pulmonary nodules inside the parenchyma, it cannot be used during video-assisted surgical procedures. Real-time, non-ionizing, ultrasound-based techniques are an attractive alternative for nodule localization to ensure safe resection margins during surgery. Conventional ultrasound B-mode imaging of the lung is challenging due to multiple scattering. However, the multiple scattering contribution can be exploited to detect regions inside the lung containing no scatterers. Pulmonary nodules are homogeneous regions in contrast to the highly scattering parenchyma containing millions of air-filled alveoli. We developed a method relying on mapping the multiple scattering contribution inside the highly scattering lung to detect and localize pulmonary nodules. Impulse response matrices were acquired in ex-vivo pig and dog lungs using a linear array transducer to semi-locally investigate the backscattered field. Extracting the multiple-scattering contribution using singular-value decomposition and combining it with a depression detection algorithm allowed us to detect and localize regions with less multiple scattering, associated with the nodules. The feasibility of this method was demonstrated in five ex-vivo lungs containing a total of 20 artificial nodules. Ninety-five percent of the nodules were detected. Nodule depth and diameter significantly correlated with their ex-vivo CT-estimated counterparts (R = 0.960, 0.563, respectively).


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Animais , Cães , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Suínos , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-32924940

RESUMO

Idiopathic pulmonary fibrosis (IPF) affects 200 000 patients in the United States of America. IPF is responsible for changes in the micro-architecture of the lung parenchyma, such as thickening of the alveolar walls, which reduces compliance and elasticity. In this study, we verify the hypothesis that changes in the microarchitecture of the lung parenchyma can be characterized by exploiting multiple scattering of ultrasound waves by the alveolar structure. Ultrasound propagation in a highly scattering regime follows a diffusion process, which can be characterized using the diffusion constant. We hypothesize that in a fibrotic lung, the thickening of the alveolar wall reduces the amount of air (compared with a healthy lung), thereby minimizing the scattering events. Pulmonary fibrosis is created in Sprague-Dawley rats by instilling bleomycin into the airway. The rats are studied within 3 weeks after bleomycin administration. Using a 128-element linear array transducer operating at 7.8 MHz, in vivo experimental data are obtained from Sprague-Dawley rats and the transport mean free path (L*) and backscatter frequency shift (BFS) are evaluated. Significant differences ( ) in the L* values between control and fibrotic rats and in the BFS values between fibrotic and edematous rats showcase the potential of these parameters for diagnosis and monitoring of IPF.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Edema Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/diagnóstico por imagem , Ultrassonografia/métodos , Animais , Modelos Animais de Doenças , Feminino , Masculino , Ratos , Ratos Sprague-Dawley