1.
Am J Orthod Dentofacial Orthop ; 153(6): 895-904, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29853247

RESUMO

INTRODUCTION: The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. METHODS: Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. RESULTS: Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. CONCLUSIONS: Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery.


Assuntos
Avanço Mandibular , Maxila/cirurgia , Apneia Obstrutiva do Sono/fisiopatologia , Humanos , Hidrodinâmica , Faringe , Projetos Piloto , Estudos Retrospectivos
2.
Angle Orthod ; 86(6): 976-982, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27120198

RESUMO

OBJECTIVE: To analyze and compare pharyngeal airflow characteristics pre- and post-mandibular setback surgery in patients with Class III skeletal dysplasia using cone beam computed tomography (CBCT) and computational fluid dynamics (CFD). MATERIALS AND METHODS: Records of 29 patients who had received orthodontic treatment along with mandibular setback surgery were obtained. CBCT scans were obtained at three time points: T1 (before surgery), T2 (average of 6 months after surgery), and T3 (average of 1 year after surgery). Digitized pharyngeal airway models were generated from these scans. CFD was used to simulate and characterize pharyngeal airflow. RESULTS: Mean airway volume was significantly reduced from 35,490.324 mm3 at T1 to 24,387.369 mm3 at T2 and 25,069.459 mm3 at T3. Significant increase in mean negative pressure was noted from 3.110 Pa at T1 to 6.116 Pa at T2 and 6.295 Pa at T3. There was a statistically significant negative correlation between the change in airway volume and the change in pressure drop at both the T2 and T3 time points. There was a statistically significant negative correlation between the amount of mandibular setback and change in pressure drop at the T2 time point. CONCLUSIONS: Following mandibular setback surgery, pharyngeal airway volume was decreased and relative mean negative pressure was increased, implying an increased effort required from a patient for maintaining constant pharyngeal airflow. Thus, high-risk patients undergoing a large amount of mandibular setback surgery should be evaluated for obstructive sleep apnea and the proposed treatment plan be revised based on the risk for potential airway compromise.


Assuntos
Hidrodinâmica , Má Oclusão Classe III de Angle/cirurgia , Faringe/anatomia & histologia , Adolescente , Adulto , Cefalometria , Tomografia Computadorizada de Feixe Cônico , Feminino , Seguimentos , Humanos , Masculino , Mandíbula , Pessoa de Meia-Idade , Adulto Jovem