1.
Basic Res Cardiol ; 119(1): 93-112, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38170280

RESUMO

In recent years, SGLT2 inhibitors have become an integral part of heart failure therapy, and several mechanisms contributing to cardiorenal protection have been identified. In this study, we place special emphasis on the atria and investigate acute electrophysiological effects of dapagliflozin to assess the antiarrhythmic potential of SGLT2 inhibitors. Direct electrophysiological effects of dapagliflozin were investigated in patch clamp experiments on isolated atrial cardiomyocytes. Acute treatment with elevated-dose dapagliflozin caused a significant reduction of the action potential inducibility, the amplitude and maximum upstroke velocity. The inhibitory effects were reproduced in human induced pluripotent stem cell-derived cardiomyocytes, and were more pronounced in atrial compared to ventricular cells. Hypothesizing that dapagliflozin directly affects the depolarization phase of atrial action potentials, we examined fast inward sodium currents in human atrial cardiomyocytes and found a significant decrease of peak sodium current densities by dapagliflozin, accompanied by a moderate inhibition of the transient outward potassium current. Translating these findings into a porcine large animal model, acute elevated-dose dapagliflozin treatment caused an atrial-dominant reduction of myocardial conduction velocity in vivo. This could be utilized for both, acute cardioversion of paroxysmal atrial fibrillation episodes and rhythm control of persistent atrial fibrillation. In this study, we show that dapagliflozin alters the excitability of atrial cardiomyocytes by direct inhibition of peak sodium currents. In vivo, dapagliflozin exerts antiarrhythmic effects, revealing a potential new additional role of SGLT2 inhibitors in the treatment of atrial arrhythmias.


Assuntos
Fibrilação Atrial , Compostos Benzidrílicos , Glucosídeos , Células-Tronco Pluripotentes Induzidas , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Animais , Suínos , Miócitos Cardíacos , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Antiarrítmicos/farmacologia , Antiarrítmicos/uso terapêutico , Potenciais de Ação , Sódio
2.
J Thromb Thrombolysis ; 57(6): 888-897, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38709456

RESUMO

Intraoperative antithrombotic drug removal by haemoadsorption is a novel strategy to reduce perioperative bleeding in patients on antithrombotic drugs undergoing cardiac surgery. The international STAR registry reports real-world clinical outcomes associated with this application. All patients underwent cardiac surgery before completing the recommended washout period. The haemoadsorption device was incorporated into the cardiopulmonary bypass (CPB) circuit. Patients on P2Y12 inhibitors comprised group 1, and patients on direct-acting oral anticoagulants (DOAC) group 2. Outcome measurements included bleeding events according to standardised definitions and 24-hour chest-tube-drainage (CTD). 165 patients were included from 8 institutions in Austria, Germany, Sweden, and the UK. Group 1 included 114 patients (62.9 ± 11.6years, 81% male) operated at a mean time of 33.2 h from the last P2Y12 inhibitor dose with a mean CPB duration of 117.1 ± 62.0 min. Group 2 included 51 patients (68.4 ± 9.4years, 53% male), operated at a mean time of 44.6 h after the last DOAC dose, with a CPB duration of 128.6 ± 48.4 min. In Group 1, 15 patients experienced a BARC-4 bleeding event (13%), including 3 reoperations (2.6%). The mean 24-hour CTD was 651 ± 407mL. In Group 2, 8 patients experienced a BARC-4 bleeding event (16%) including 4 reoperations (7.8%). The mean CTD was 675 ± 363mL. This initial report of the ongoing STAR registry shows that the intraoperative use of a haemoadsorption device is simple and safe, and may potentially mitigate the expected high bleeding risk of patients on antithrombotic drugs undergoing cardiac surgery before completion of the recommended washout period.Clinical registration number: ClinicalTrials.gov identifier: NCT05077124.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Fibrinolíticos , Sistema de Registros , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fibrinolíticos/administração & dosagem , Fibrinolíticos/uso terapêutico , Fibrinolíticos/efeitos adversos , Cuidados Intraoperatórios/métodos , Ponte Cardiopulmonar/métodos , Perda Sanguínea Cirúrgica/prevenção & controle
3.
Artif Organs ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984611

RESUMO

BACKGROUND: Due to its high impact on quality of life and mental health, close monitoring and often psychotherapy is recommended for patients with a ventricular assist device (VAD). This study investigates the psychological comorbidity and the corresponding psychotherapeutic treatment situation of VAD patients. Special attention is also given to the professional perspective VAD team (assistant and senior cardiologists and specialized nurses). METHODS: We conducted a cross-sectional observational study. Data from 50 VAD patients (mean age = 53.52, standard deviation = 13.82 years, 84.0% male) and their VAD team were analyzed. The presence of a psychological disorder was evaluated by structured clinical interviews for DSM-IV (SCID-I-Interviews). Patients answered a questionnaire regarding their current psychotherapeutic treatment status and their attitude towards psychotherapy. The VAD team answered a questionnaire about the patients' needs for psychotherapy and indicated whether they addressed this topic with the patient. Data were analyzed descriptively, by analysis of variance and t-test. RESULTS: A total of 58% of VAD patients suffered from at least one significant psychological disorder, 79.3% of those were not in psychotherapy. The VAD team could not identify the patients who suffered from a psychological disorder (F = 1.90; p = 0.18). They perceived more need for psychotherapy than they addressed with their patients (T = 3.39; p < 0.001). CONCLUSIONS: While there is a high psychological morbidity among VAD patients, only few receive psychotherapy. Psychological comorbidity is not easily detected by the VAD team. Standardized psychosocial care could be implemented by regular psychological assessments and further information of patients and their VAD teams.

4.
J Mol Cell Cardiol ; 184: 26-36, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37793594

RESUMO

RATIONALE: The neurokinin-III receptor was recently shown to regulate atrial cardiomyocyte excitability by inhibiting atrial background potassium currents. TASK-1 (hK2P3.1) two-pore-domain potassium channels, which are expressed atrial-specifically in the human heart, contribute significantly to atrial background potassium currents. As TASK-1 channels are regulated by a variety of intracellular signalling cascades, they represent a promising candidate for mediating the electrophysiological effects of the Gq-coupled neurokinin-III receptor. OBJECTIVE: To investigate whether TASK-1 channels mediate the neurokinin-III receptor activation induced effects on atrial electrophysiology. METHODS AND RESULTS: In Xenopus laevis oocytes, heterologously expressing neurokinin-III receptor and TASK-1, administration of the endogenous neurokinin-III receptor ligands substance P or neurokinin B resulted in a strong TASK-1 current inhibition. This could be reproduced by application of the high affinity neurokinin-III receptor agonist senktide. Moreover, preincubation with the neurokinin-III receptor antagonist osanetant blunted the effect of senktide. Mutagenesis studies employing TASK-1 channel constructs which lack either protein kinase C (PKC) phosphorylation sites or the domain which is regulating the diacyl glycerol (DAG) sensitivity domain of TASK-1 revealed a protein kinase C independent mechanism of TASK-1 current inhibition: upon neurokinin-III receptor activation TASK-1 channels are blocked in a DAG-dependent fashion. Finally, effects of senktide on atrial TASK-1 currents could be reproduced in patch-clamp measurements, performed on isolated human atrial cardiomyocytes. CONCLUSIONS: Heterologously expressed human TASK-1 channels are inhibited by neurokinin-III receptor activation in a DAG dependent fashion. Patch-clamp measurements, performed on human atrial cardiomyocytes suggest that the atrial-specific effects of neurokinin-III receptor activation on cardiac excitability are predominantly mediated via TASK-1 currents.


Assuntos
Fibrilação Atrial , Canais de Potássio de Domínios Poros em Tandem , Humanos , Animais , Fibrilação Atrial/metabolismo , Átrios do Coração/metabolismo , Transdução de Sinais , Proteína Quinase C/metabolismo , Potássio/metabolismo , Xenopus laevis/metabolismo , Oócitos/metabolismo , Canais de Potássio de Domínios Poros em Tandem/genética , Canais de Potássio de Domínios Poros em Tandem/metabolismo
6.
Am J Transplant ; 22(8): 2064-2076, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35426974

RESUMO

Heart transplantation across preformed donor-specific HLA-antibody barriers is associated with impaired short- and long-term survival. Therefore, in recipients with preformed anti-HLA antibodies, waiting for crossmatch-negative donors is standard practice. As an alternative strategy, recipients with preformed anti-HLA donor specific antibodies have been managed at our institutions with a perioperative desensitization regimen. A retrospective analysis was performed comparing heart transplant recipients with preformed donor-specific HLA-antibodies to recipients without donor-specific antibodies. Recipients with a positive virtual crossmatch received a perioperative desensitization protocol including tocilizumab intraoperatively, plasma exchange and rituximab followed by a six-month course of IgGAM. Among the 117 heart-transplanted patients, 19 (16%) patients underwent perioperative desensitization, and the remaining 98 (84%) patients did not. Cold ischemic time, posttransplant extracorporeal life support for primary graft dysfunction, and intensive care unit stay time did not differ between groups. At 1-year follow-up, freedom from pulsed steroid therapy for presumed rejection and biopsy-confirmed acute cellular or humoral rejection did not differ between groups. One-year survival amounted to 94.7% in the treated patients and 81.4% in the control group. Therefore, heart transplantation in sensitized recipients undergoing a perioperative desensitization appears safe with comparable postoperative outcomes as patients with a negative crossmatch.


Assuntos
Transplante de Coração , Transplante de Rim , Anticorpos , Soro Antilinfocitário , Dessensibilização Imunológica/métodos , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/prevenção & controle , Sobrevivência de Enxerto , Antígenos HLA , Teste de Histocompatibilidade/métodos , Humanos , Transplante de Rim/efeitos adversos , Estudos Retrospectivos
7.
Artif Organs ; 46(1): 106-116, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34398476

RESUMO

The resolution of functional mitral valve regurgitation (MR) in patients awaiting left ventricular assist device (LVAD) implantation is discussed controversially. The present study analyzed MR and echocardiographic parameters of the third-generation LVAD HeartMate 3 (HM3) over 3 years. Of 135 LVAD patients (with severe MR, n = 33; with none, mild, or moderate MR, n = 102), data of transthoracic echocardiography were included preoperatively to LVAD implantation, up to 1 month postoperatively, and at 1, 2, and 3 years after LVAD implantation. Demographic data and clinical characteristics were collected. Severe MR was reduced immediately after LVAD implantation in all patients. The echocardiographic parameters left ventricular end-diastolic diameter (P < .001), right ventricular end-diastolic diameter (P < .001), tricuspid annular plane systolic excursion (P < .001), and estimated pulmonary artery pressure (P < .001) decreased after HM3 implantation independently from the grade of MR prior to implantation and remained low during the 2 years follow-up period. Following LVAD implantation, right heart failure, ventricular arrhythmias, ischemic stroke as well as pump thrombosis and bleeding events were comparable between the groups. The incidences of death and cardiac death did not differ between the patient groups. Furthermore, the Kaplan-Meier analysis showed that survival was comparable between the groups (P = .073). HM3 implantation decreases preoperative severe MR immediately after LVAD implantation. This effect is long-lasting in most patients and reinforces the LVAD implantation without MR surgery. The complication rates and survival were comparable between patients with and without severe MR.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Insuficiência da Valva Mitral/fisiopatologia , Adulto , Ecocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/patologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Implantação de Prótese , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
8.
Int J Mol Sci ; 23(18)2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36142161

RESUMO

Non-surgical bleeding (NSB) is one of the major clinical complications in patients under continuous-flow left ventricular assist device (LVAD) support. The increased shear stress leads to an altered platelet receptor composition. Whether these changes increase the risk for NSB is unclear. Thus, we compared the platelet receptor composition of patients with (bleeder group, n = 18) and without NSB (non-bleeder group, n = 18) prior to LVAD implantation. Blood samples were obtained prior to LVAD implantation and after bleeding complications in the post-implant period. Platelet receptor expression of GPIbα, GPIIb/IIIa, P-selectin and CD63 as well as intra-platelet oxidative stress levels were quantified by flow cytometry. Bleeders and non-bleeders were comparable regarding clinical characteristics, von Willebrand factor diagnostics and the aggregation capacity before and after LVAD implantation (p > 0.05). LVAD patients in the bleeder group suffered from gastrointestinal bleeding (33%; n = 6), epistaxis (22%; n = 4), hematuria or hematoma (17%; n = 3, respectively) and cerebral bleeding (11%; n = 2). Prior to LVAD implantation, a restricted surface expression of the platelet receptors P-selectin and GPIIb/IIIa was observed in the bleeder group (P-selectin: 7.2 ± 2.6%; GPIIb/IIIa: 26,900 ± 13,608 U) compared to non-bleeders (P-selectin: 12.4 ± 8.1%, p = 0.02; GPIIb/IIIa: 36,259 ± 9914 U; p = 0.02). We hypothesized that the reduced platelet receptor expression of P-selectin and GPIIb/IIIa prior to LVAD implantation may be linked to LVAD-related NSB.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Plaquetas/metabolismo , Insuficiência Cardíaca/metabolismo , Coração Auxiliar/efeitos adversos , Hemorragia , Humanos , Selectina-P/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/metabolismo , Fator de von Willebrand/metabolismo
9.
Thorac Cardiovasc Surg ; 69(6): 518-525, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33260235

RESUMO

BACKGROUND: The exact monitoring of the therapeutic-range international normalized ratio (INR) after left ventricular assist device (LVAD) implantation is an important aim to reduce the risk of thrombosis or bleeding complications. Service providers offer a telemedical anticoagulation service (CS). METHODS: We compared LVAD patients using the CS (n = 15) to those who received regular medical care (RMC; n = 15) to investigate if telemedicine supervision increased the INR-specific time in the therapeutic range (TTR) during anticoagulation. All patients received self-management training for phenprocoumon medication according to their INR value. INR values were documented for 12 months. A survey (scale: 1 = not satisfied and 10 = very satisfied) was used to determine patient's satisfaction and psychological well-being. RESULTS: A total of 1,798 INR measurements were analyzed. The TTRRosendaal was higher in patients undergoing RMC (78.1 ± 14.3%) compared with that in patients using the CS (58.3 ± 28.0%, p = 0.03). The patient's satisfaction with the coagulation setting at the beginning of the study (RMC: 6.7 ± 3.1, CS: 7.2 ± 3.0, p = 0.74) and psychological wellbeing (RMC: 6.5 ± 1.9, CS: 6.5 ± 2.7, p = 0.97) were comparable between both groups. CONCLUSION: We found that INR self-management is superior regarding the efficiency of post-LVAD anticoagulation therapy when compared with telemedical (CS)-based INR management in a small study cohort. Intensive training by experienced staff was able to replace CS.


Assuntos
Anticoagulantes/uso terapêutico , Monitoramento de Medicamentos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Femprocumona/uso terapêutico , Implantação de Prótese/instrumentação , Autocuidado , Telemedicina , Trombose/prevenção & controle , Função Ventricular Esquerda , Anticoagulantes/efeitos adversos , Alemanha , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemorragia/induzido quimicamente , Humanos , Coeficiente Internacional Normatizado , Satisfação do Paciente , Femprocumona/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Qualidade de Vida , Trombose/diagnóstico , Trombose/etiologia , Resultado do Tratamento
10.
Artigo em Alemão | MEDLINE | ID: mdl-25634374

RESUMO

The use of mechanically circulatory support devices (MCS) will become increasingly important as a therapy option in patients with end-stage heart failure, and emergency physicians will more frequently encounter MCS patients in the next few years. However, emergency management in MCS patients has not yet been standardized. In the following article, common MCS devices are presented and typical emergencies associated with MCS devices are discussed. Furthermore, we try to give recommendations for the management of MCS patients in an emergency situation and present an algorithm in order to facilitate a structured and timely efficient evaluation of the MCS patient.


Assuntos
Algoritmos , Cuidados Críticos/normas , Serviços Médicos de Emergência/métodos , Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar , Serviços Médicos de Emergência/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Alemanha , Humanos , Guias de Prática Clínica como Assunto
11.
ASAIO J ; 70(5): 371-376, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38153977

RESUMO

To reduce adhesions after left ventricular assist device (LVAD) implantation, pericardial closure using an expanded polytetrafluoroethylene (ePTFE) patch has been suggested. However, as foreign material, ePTFE patches could increase the risk of infectious complications. In this single-center retrospective study, we investigated outcomes of pericardial closure using an ePTFE patch in LVAD implantation. We included all patients who underwent LVAD implantation at our center between 2011 and 2020 (n = 166). Primary endpoint was development of mediastinitis at any point of time between LVAD implantation and heart transplantation (HTx) or death. Secondary endpoint was overall survival. Preoperative and postoperative clinical data were collected to ensure comparability between the groups. We included 166 patients with LVAD. A total of 116 patients (70%) underwent pericardial closure using an ePTFE patch. There were significant differences between the groups in treatment setting, previous cardiac surgery, Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level, development of driveline infection, and HTx. Patients with an ePTFE patch developed mediastinitis more frequently (16%) than patients without ePTFE patch (4%) ( p = 0.039). A significant difference in overall survival between the groups could not be confirmed ( p = 0.29). The use of PTFE patches for pericardial closure in LVAD implantation was associated with a higher incidence of mediastinitis, but not with a difference in overall survival.


Assuntos
Coração Auxiliar , Pericárdio , Politetrafluoretileno , Humanos , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Adulto , Mediastinite/etiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia
12.
JTCVS Open ; 15: 252-260, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37808068

RESUMO

Objectives: Patients with ischemic cardiomyopathy undergoing coronary artery bypass grafting (CABG) surgery may develop postcardiotomy cardiogenic shock. In these cases, implantation of an Impella 5.0 or 5.5 microaxial pump offers full hemodynamic support while simultaneously unloading of the left ventricle. Methods: Preoperative, perioperative, and postoperative data of all patients receiving postoperative support with an Impella 5.0 or 5.5 after CABG surgery between September 2017 and October 2022 were retrospectively collected. Cohort built-up was performed according to the timing of Impella implantation, either simultaneous during CABG surgery or delayed. Results: A total of n = 42 patients received postoperative Impella support, of whom 27 patients underwent simultaneous Impella implantation during CABG surgery and 15 patients underwent delayed Impella therapy. Preoperative left ventricular ejection fraction was similarly low in both groups (26.7 ± 0.7% vs 24.8 ± 11.3%; P = .32). In the delayed cohort, Impella implantation was performed after a median of 1 (1; 2) days after CABG surgery. Survival after 30 days (75.6% vs 47.6%, P = .04) and 1 year (69.4% vs 29.8%, P = .03) was better in the cohort receiving simultaneous Impella implantation. Conclusions: The combined advantages of hemodynamic support and LV unloading with microaxial pumps may lead to a favorable survival in patients with left ventricular failure following CABG surgery. Early implantation during the initial surgery shows a trend toward a more favorable survival as compared with patients receiving delayed support.

13.
J Heart Lung Transplant ; 42(6): 778-785, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36710093

RESUMO

BACKGROUND: When advanced heart failure occurs in cardiac amyloidosis, prognosis is poor. In this setting heart transplantation (HTX) is a treatment option for selected patients. We here present the results of post-transplantation outcomes in cardiac amyloidosis within the Eurotransplant area, investigating possible predictors of survival. METHODS: Of 115 patients undergoing HTX due to cardiac amyloidosis in the Eurotransplant region between November 1987 and May 2020, detailed assessment prior to transplantation was available in 85 patients. The present study was conducted in a retrospective approach. Primary endpoint was mortality after HTX. Baseline variables were entered in a Cox proportional hazards model with the primary endpoint as a dependent variable. RESULTS: Median overall survival following HTX was 6.3 years in the overall collective and the subgroup. Univariate Cox proportional hazards model revealed a significant relationship between overall survival and the transplantation period (2008 to 2020 vs 1987 to 2007; median survival 9.7 years vs 1.8 years, hazard ratio 0.45, p = 0.01). Further predictors were albumin concentration (hazard ratio 0.92, p < 0.001), and systolic blood pressure (hazard ratio 0.96, p < 0.001). The transplant period as well as albumin concentration remained significant independent predictors in the AL sub cohort in a multivariate Cox proportional hazards model. CONCLUSIONS: HTX is a viable treatment option for patients at an advanced stage of cardiac amyloidosis as overall survival after transplantation has improved in the modern age. Patients at a very advanced stage of the disease, indicated by low serum albumin and blood pressure, show worse outcomes following HTX. Optimal timing and careful patient selection may therefore be particularly important to further improve post-HTX survival in amyloidosis patients.


Assuntos
Amiloidose , Insuficiência Cardíaca , Transplante de Coração , Humanos , Estudos Retrospectivos , Transplante de Coração/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Amiloidose/complicações , Amiloidose/cirurgia , Albuminas
14.
Antibiotics (Basel) ; 11(5)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35625185

RESUMO

Dalbavancin is emerging as a promising alternative in the ambulant treatment of gram-positive infections that require long-term antibiotic treatment such as osteomyelitis, prosthetic joint infections, and endocarditis. The aim of the current study was to develop and validate a simple, rapid, and cost-effective high-performance liquid chromatography-ultraviolet spectrometry (HPLC-UV) method for the quantification of dalbavancin. Sample clean-up included a protein precipitation protocol, followed by chromatographic separation on a reverse phase HPLC column (C-18) with gradient elution of the mobile phase. Quantification was performed with the internal standard (caffeine) method. Linear relationships between peak area responses and drug concentrations were obtained in the range of 12.5-400 mg/L. The variation coefficient of precision and the bias of accuracy (both inter- and intraday) were less than 10%. The limit of quantification (LOQ) was 12.5 mg/L. The simple and reliable HPLC-UV assay described is a powerful tool for routine therapeutic drug monitoring (TDM) of dalbavancin in human serum in clinical laboratories. With a total process time of approximately 20 min, it allows for accurate and selective quantification up to the expected pharmacokinetic peak concentrations. The method was successfully used to analyze subsequent serum samples of three patients and showed good performance in monitoring serum levels.

15.
Life (Basel) ; 12(10)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36294985

RESUMO

The Berlin Heart® EXCOR is a paracorporeal, pulsatile ventricular assist device used in patients of all age groups. However, adolescent and adult patients on EXCOR support are scarcely explored. Herein, we present a detailed description of infectious complications in this patient cohort. From 2006 to 2020, 58 patients received a biventricular assist device (BiVAD) at our institution and were included in this study. Postoperative infections were assessed after BiVAD implantation and subsequent heart transplantation (HTx). A Berlin Heart® EXCOR BiVAD was implanted as a bridge to transplantation in 58 patients (12-64 years). Most patients were INTERMACS I, and their median age was 49 years. Wound infections (WI) specific to the ventricular assist device (VAD) occurred in 31 (53.4%) patients with a mean time of 113 ± 155 days after BiVAD implantation. HTx was performed in 30 (51.7%) patients and thereof 10 (33.3%) patients developed at least one WI post-HTx. The mean time of WI after HTx was 17 ± 14 days. In four cases, WIs were caused by the same pathogen as before HTx. According to our institutional BiVAD wound classification, the mean wound score was 3. The VAD-specific wound infections were manageable and did not increase mortality nor precluded HTx in Berlin Heart® EXCOR patients. No specific risk factors for VAD-specific wound infections could be identified.

16.
Curr Opin Cardiol ; 26(3): 232-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21430527

RESUMO

PURPOSE OF REVIEW: Destination therapy with a left ventricular assist device (LVAD) has the potential to effectively treat a large number of patients with advanced heart failure who are not eligible for heart transplantation. With the advent of continuous-flow LVADs, safe and effective long-term circulatory support is available for properly identified candidates. RECENT FINDINGS: The highest mortality following LVAD implant is observed in the sickest patients (INTERMACS profile 1); therefore, there is an increasing trend toward selecting patients with INTERMACS profiles 2-5. The less-ill patients will be studied in the planned REVIVE-IT trial. The Heart Failure Survival Score, Seattle Heart Failure Model, and Destination Therapy Risk Score may provide guidance for patient selection and preoperative optimization therapy, but these tools need to be updated for current LVAD technology. The current 1-year survival rate for patients supported for destination therapy with a continuous-flow LVAD is 74%, which represents an increase of 6% since the clinical trial was completed 2 years ago. SUMMARY: Substantial progress has been made concerning survival and quality of life since destination therapy was first introduced 10 years ago. Advances in patient selection, improved LVAD technology, and optimized treatment strategies provide much optimism for the treatment of more heart failure patients in the future.


Assuntos
Insuficiência Cardíaca/terapia , Ventrículos do Coração , Coração Auxiliar , Seleção de Pacientes , Progressão da Doença , Insuficiência Cardíaca/mortalidade , Humanos , Medição de Risco , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
17.
J Thromb Haemost ; 19(5): 1331-1341, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33636040

RESUMO

BACKGROUND: Non-surgical bleeding (NSB) is a major complication after left ventricular assist device (LVAD) implantation. It has been reported that non-physiological shear stress caused by LVADs could alter platelet receptor expression, which leads to bleeding disorders caused by coagulation dysfunctions. OBJECTIVES: Because bleeding diathesis could be multifactorial, we focused on the combined characterization of platelet receptor expression patterns and oxidative stress to compare patients with NSB and patients without coagulation disorder in a monocentric, prospective study. METHODS: Blood samples were obtained from LVAD patients with NSB (bleeder group, n = 19) and without NSB (non-bleeder group, n = 20). The platelet receptors platelet endothelial cell adhesion molecule-1 (PECAM-1), glycoprotein (GP)Ibα, P-selectin, CD63, and GPIIb/IIIa, as well as the production of intraplatelet reactive oxygen species (ROS) were quantified by flow cytometry. Aggregation capacity was evaluated by aggregometry. RESULTS: The surface expression level of P-selectin and GPIbα on platelets was decreased in bleeders (P-selectin: 465 ± 72 U; GPIbα: 435 ± 41 U) compared to non-bleeders (P-selectin: 859 ± 115 U, P < .01; GPIbα: 570 ± 49 U, p = .04). Additionally, the mean fluorescence intensity of ADP-stimulated P-selectin and PECAM-1 expressing platelets were reduced in bleeders (P-selectin: 944 ± 84 U; PECAM-1: 6722 ± 419 U) compared to non-bleeders (P-selectin: 1269 ± 130 U, P = .04; PECAM-1: 8542 ± 665 U, P = .03). Bleeders showed a higher amount of ROS formation in platelets (88.0 ± 2.6%) than non-bleeders (81.5 ± 2.1%, P = .05). CONCLUSIONS: These findings suggested that changes of three platelet receptors (GPIbα, P-selectin, and PECAM-1) and elevated oxidative stress may play a role in patients with bleeding complications following LVAD implantation. These results might help to explain the high incidence of spontaneous hemorrhage during LVAD support through an altered platelet function.


Assuntos
Plaquetas/patologia , Coração Auxiliar , Coração Auxiliar/efeitos adversos , Hemorragia , Humanos , Selectina-P , Molécula-1 de Adesão Celular Endotelial a Plaquetas , Testes de Função Plaquetária , Complexo Glicoproteico GPIb-IX de Plaquetas , Estudos Prospectivos
18.
Artif Organs ; 34(9): 721-5, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20883391

RESUMO

Patient satisfaction with left ventricular assist device (LVAD) external equipment has not yet been reported. We aimed to evaluate the quality of two different systems based on patients' perspective and its interrelationship with quality of life. Differential assessment of the HeartMate II axial flow pump (n = 17; Thoratec, Pleasanton, CA, USA) and the HVAD centrifugal pump (n = 10; HeartWare, Inc., Miramar, FL, USA) was obtained from 27 outpatients by a questionnaire 2 months to 2.9 years after device implantation. In addition, a health-related quality of life questionnaire (Short Form-36 [SF-36]) was completed. Overall patients' satisfaction was high. Severe limitations were attributed to the loudness of the power base unit in HeartMate II patients (P = 0.00), and HVAD patients were dissatisfied by the length of the driveline (P = 0.02). Between HVAD and HeartMate II patients, no significant differences in the quality of life (assessed by SF-36) were reported. While the overall satisfaction of outpatients on LVAD support was high, differences between the systems were found. Patients' perspectives may have an important impact on future modification of external components. Ultimately, this may also contribute to an improvement in the quality of life of chronic LVAD patients.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Satisfação do Paciente , Qualidade de Vida , Adaptação Psicológica , Adulto , Análise de Variância , Feminino , Alemanha , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
19.
Herz ; 34(2): 148-53, 2009 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-19370332

RESUMO

Three generations of left ventricular assist devices are available for the therapy of heart failure. In the current development, pulsatile devices are being displaced by axial flow pumps. Intentions for left ventricular assist device implantations are bridge to transplantation or to recovery and destination therapy. Already the mechanical support has the drop on the conservative medical therapy; furthermore, improvements in the devices are registered. In addition, by implanting a left ventricular assist device the quality of life was improved. Consequently, the importance of left ventricular assist devices in the therapy of heart failure is increasing.


Assuntos
Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/cirurgia , Doença Crônica , Desenho de Equipamento , Humanos , Prognóstico , Medição de Risco , Fatores de Risco
20.
ASAIO J ; 70(4): 257, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38483808
SELEÇÃO DE REFERÊNCIAS