Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Science ; 246(4931): 793-6, 1989 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-17748706

RESUMO

Estimates are given of the raw data that are the basis for the claims of excess power production by the electrochemical charging of palladium in deuterium oxide (D(2)O). Calorimetric results are also presented that show no anomalous power production in either 0.1M LiOD/D(2)O or 0.1M LiOH/H(2)O (LiOH is lithium hydroxide). Several possible sources of error in open-system calorimetry are discussed that can confound interpretation of temperature changes in terms of anomalous power production.

2.
Forensic Sci Int ; 268: 131-138, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27750163

RESUMO

Clandestine laboratories pose a serious health risk to first responders, investigators, decontamination companies, and the public who may be inadvertently exposed to methamphetamine and other chemicals used in its manufacture. Therefore there is an urgent need for reliable methods to detect and measure methamphetamine at such sites. The most common method for determining methamphetamine contamination at former clandestine laboratory sites is selected surface wipe sampling, followed by analysis with gas chromatography-mass spectrometry (GC-MS). We are investigating the use of sampling for methamphetamine vapour to complement such wipe sampling. In this study, we report the use of capillary microextraction (CME) devices for sampling airborne methamphetamine, and compare their sampling efficiency with a previously reported dynamic SPME method. The CME devices consisted of PDMS-coated glass filter strips inside a glass tube. The devices were used to dynamically sample methamphetamine vapour in the range of 0.42-4.2µgm-3, generated by a custom-built vapour dosing system, for 1-15min, and methamphetamine was analysed using a GC-MS fitted with a ChromatoProbe thermal desorption unit. The devices showed good reproducibility (RSD<15%), and a curvilinear pre-equilibrium relationship between sampling times and peak area, which can be utilised for calibration. Under identical sampling conditions, the CME devices were approximately 30 times more sensitive than the dynamic SPME method. The CME devices could be stored for up to 3days after sampling prior to analysis. Consecutive sampling of methamphetamine and its isotopic substitute, d-9 methamphetamine showed no competitive displacement. This suggests that CME devices, pre-loaded with an internal standard, could be a feasible method for sampling airborne methamphetamine at former clandestine laboratories.


Assuntos
Fracionamento Químico/métodos , Tráfico de Drogas , Monitoramento Ambiental/métodos , Metanfetamina/análise , Volatilização , Poluentes Ambientais/análise , Humanos , Drogas Ilícitas/análise
3.
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA