Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Environ Manage ; 92(1): 178-84, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20869158

RESUMO

Activated carbons were prepared from flamboyant pods by NaOH activation at three different NaOH:char ratios: 1:1 (AC-1), 2:1 (AC-2), and 3:1 (AC-3). The properties of these carbons, including BET surface area, pore volume, pore size distribution, and pore diameter, were characterized from N(2) adsorption isotherms. The activated carbons obtained were essentially microporous and had BET surface area ranging from 303 to 2463 m(2) g(-1).(13)C (CP/MAS and MAS) solid-state NMR shows that the lignocellulosic structures were completely transformed into a polycyclic material after activation process, thermogravimetry shows a high thermal resistance, Boehm titration and Fourier-transform infrared spectroscopy allowed characterizing the presence of functional groups on the surface of activated carbons. Scanning electron microscopy images showed a high pore development. The experimental results indicated the potential use of flamboyant pods as a precursor material in the preparation of activated carbon.


Assuntos
Carbono/química , Fabaceae/química , Lignina/química , Porosidade , Sementes , Temperatura
2.
Food Chem ; 138(1): 574-80, 2013 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-23265526

RESUMO

This study proposes a FRAP assay adapted to FIA system with a merging zones configuration. The FIA system conditions were optimised with the response surface methodology using the central composite rotatable design. The optimisation parameters studied were: the carrier flow rate, the lengths of the sample and reagent loops, and reactor length. The conditions selected in accordance with the results were: carrier flow rate of 1.00 ml/min, length of the loops 18.2 cm and length of the reaction coil 210.1 cm. The detection and quantification limits were, respectively, 28.6 and 86.8 µmol/l Fe(2+), and the precision was 1.27%. The proposed method had an analytical frequency of 30 samples/h and about 95% less volume of FRAP reagent was consumed. The FRAP assay adapted to the FIA system under the optimised conditions was utilised to determine the antioxidant activity of tea samples.


Assuntos
Antioxidantes/análise , Técnicas de Química Analítica/métodos , Compostos Férricos/química , Análise de Injeção de Fluxo/métodos , Chá/química , Oxirredução
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA