Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Hypertens Res ; 46(3): 730-741, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36575229

RESUMO

The effect of arterial stiffening on elevated pulsatile left ventricular afterload patients with aortic stenosis (AS) is pronounced beyond systemic hypertension. Circulatory afterload pulsatile efficiency (CAPE) is a marker of vascular function, defined as the ratio of steady state energy consumption (SEC) to maintain systemic circulation and pulsatile energy consumption (PEC). Twenty patients aged 80 ± 7 years were assessed at baseline and a median of 60 days post transcatheter aortic valve replacement (TAVR), with pulsatile vascular load calculated using simultaneous radial applanation tonometry derived aortic pressure and cardiac magnetic resonance phase-contrast imaging derived ascending aortic flow. Eight out of 20 patients had a reduction in PEC post TAVR, and the reduction of PEC correlated strongly with the number of days post TAVR (R = 0.62, P < 0.01). Patients assessed within the 100 days of TAVR had a rise in their PEC when compared to baseline (0.19 ± 0.09 vs 0.14 ± 0.08 W, P = 0.04). Baseline PEC correlated moderately with baseline SEC (R = 0.49, P = 0.03), and a high baseline PEC was predictive of post TAVR PEC reduction (R = 0.54, P =0.01). Overall, no significant differences were found between baseline and post TAVR for systolic aortic pressure (131 ± 20 vs 131 ± 20 mmHg), systemic vascular resistance (1894 ± 493 vs 2015 ± 519 dynes.s/cm5), aortic valve ejection time (337 ± 22 vs 324 ± 34 ms) or aortic characteristic impedance (120 ± 48 vs 107 ± 41 dynes.s/cm5). Improved flow profiles after TAVR likely unmask the true vascular properties by altering ventriculo-valvulo-arterial coupling, leading to downstream vascular remodelling secondary to flow conditioning, and results in eventual improvement of pulsatile afterload as reflected by our proposed index of CAPE.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Função Ventricular Esquerda , Biomarcadores , Índice de Gravidade de Doença
2.
J Hypertens ; 39(3): 437-446, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33031178

RESUMO

INTRODUCTION: Ventricular function in elderly patients with aortic stenosis is impeded both by restricted aortic flow and arterial stiffening. A number of patients continue to have exertional intolerance after relief of aortic valvular obstruction due to unrecognized ventriculo-arterial coupling mismatch. HYPOTHESIS: Quantification of valvulo-arterial load (VAL), using a simultaneous applanation tonometry/cardiac magnetic resonance (CMR) technique, can accurately assess the relative contributions of aortic stiffness and valve gradient in older patients with aortic stenosis. METHODS: Elderly patients with aortic stenosis underwent a simultaneous applanation tonometry/CMR protocol. CMR provided left ventricular volume and aortic flow simultaneously with radial applanation tonometry pressure acquisition. Central aortic pressure was derived by transformation of the radial applanation tonometry waveform. VAL was determined as the relationship of derived aortic pressure to CMR aortic flow in frequency domain (central illustration). RESULTS: Twenty patients (age 80 ±â€Š9 years; 12 males; blood pressure 140/75 ±â€Š20 mmHg) with aortic stenosis on transthoracic echocardiogram (16 severe; mean gradient 45 ±â€Š16 mmHg; aortic valve area 0.8 ±â€Š0.2 cm2) were enrolled. Derived aortic pressure and flow waveforms correlated well with invasive data. Increased VAL was significantly associated with advanced age (P = 0.04) and raised SBP (P < 0.01), irrespective of aortic stenosis severity. CONCLUSION: Difficulties in the measurement and accuracy of ventriculo-arterial coupling means that it is not routinely measured in patients with aortic stenosis. We describe a new noninvasive index that provides an accurate assessment of valvular and arterial load on the left ventricle. VAL may help detect those at risk of ventriculo-arterial coupling mismatch and assist in selection of those most likely to benefit from an invasive procedure.


Assuntos
Estenose da Valva Aórtica , Rigidez Vascular , Idoso , Aorta , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico por imagem , Pressão Sanguínea , Criança , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA