Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BJU Int ; 119(1): 164-170, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27597563

RESUMO

OBJECTIVES: To assess the safety and acceptability of early infant circumcision (EIC) provided by trained clinical officers (COs) and registered nurse midwives (RNMWs) in rural Uganda. SUBJECTS AND METHODS: We conducted a randomised trial of EIC using the Mogen clamp provided by newly trained COs and RNMWs in four health centres in rural Rakai, Uganda. The trial was registered with clinicaltrials.gov # NCT02596282. In all, 501 healthy neonates aged 1-28 days with normal birth weight and gestational age were randomised to COs (n = 256) and RNMWs (n = 245) for EIC, and were followed-up at 1, 7 and 28 days. RESULTS: In all, 701 mothers were directly invited to participate in the trial, 525 consented to circumcision (74.9%) and 23 were found ineligible on screening (4.4%). The procedure took an average of 10.5 min. Adherence to follow-up was >90% at all scheduled visits. The rates of moderate/severe adverse events were 2.4% for COs and 1.6% for RNMWs (P = 0.9). All wounds were healed by 28 days after circumcision. Maternal satisfaction with the procedure was 99.6% for infants circumcised by COs and 100% among infants circumcised by RNMWs. CONCLUSIONS: EIC was acceptable in this rural Ugandan population and can be safely performed by RNMWs who have direct contact with the mothers during pregnancy and delivery. EIC services should be made available to parents who are interested in the service.


Assuntos
Circuncisão Masculina/instrumentação , Pessoal de Saúde , Humanos , Recém-Nascido , Masculino , Enfermeiros Obstétricos , Enfermeiras e Enfermeiros , Uganda
2.
BJU Int ; 119(4): 631-637, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27753243

RESUMO

OBJECTIVE: To assess acquisition of knowledge and competence in performing Early Infant Male Circumcision (EIMC) by non-physicians trained using a structured curriculum. SUBJECTS AND METHODS: Training in provision of EIMC using the Mogen clamp was conducted for 10 Clinical Officers (COs) and 10 Registered Nurse Midwives (RNMWs), in Rakai, Uganda. Healthy infants whose mothers consented to study participation were assigned to the trainees, each of whom performed at least 10 EIMCs. Ongoing assessment and feedback for competency were done, and safety assessed by adverse events. RESULTS: Despite similar baseline knowledge, COs acquired more didactic knowledge than RNMWs (P = 0.043). In all, 100 EIMCs were assessed for gain in competency. The greatest improvement in competency was between the first and third procedures, and all trainees achieved 80% competency and retention of skills by the seventh procedure. The median (interquartile range) time to complete a procedure was 14.5 (10-47) min for the COs, and 15 (10-50) min for the RNMWs (P = 0.180). The procedure times declined by 2.2 min for each subsequent EIMC (P = 0.005), and rates of improvement were similar for COs and RNMWs. Adverse events were comparable between providers (3.5%), of which 1% were of moderate severity. CONCLUSION: Competence-based training of non-physicians improved knowledge and competency in EIMC performed by COs and RNMWs in Uganda.


Assuntos
Circuncisão Masculina/educação , Circuncisão Masculina/métodos , Competência Clínica/normas , Instrumentos Cirúrgicos , Atitude do Pessoal de Saúde , Currículo , Humanos , Recém-Nascido , Masculino , Uganda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA