Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Int J Cardiol ; 227: 225-228, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27866867

RESUMO

AIM: To analyze whether PPM affects QOL and functional status in patients after isolated AVR for aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF). METHODS: Consecutive patients who underwent AVR in University Hospital Center Zagreb for isolated severe symptomatic AS and preserved EF were enrolled. Echo data was obtained from complete transthoracic examinations prior and after surgery by offline analysis. Patients were divided into two groups according to the presence of PPM (effective orifice area (EOA)/body surface area (BSA)<0,85cm2/m2). QOL was assessed by telephone interview using Short Form 36-Item Health Survey (SF-36) along with functional NYHA status estimation. RESULTS: A total of 45 pts were included (23 female), and divided in PPM (n=26), and non-PPM group (n=19). Both groups were similar in pts age, LVEF, AVA/BSA prior surgery. After surgery, 57% of pts had PPM categorized as mild PPM. During follow-up of 2,5years, 3 pts had died and 10 were lost from following. There was no difference in NYHA status after surgery between groups (p=0,758). SF36 results showed no difference between groups. However, there was a significant improvement in Physical functioning (47,50% vs 75,47%,p=0,000) and Role limitation due to physical health (41,41% vs 81,25%, p=0,007) scores in the whole study population after AVR. Males had significantly better Energy/fatigue (p=0,034), Social functioning (p=0,004) and Pain (p=0,017) scores. CONCLUSIONS: Mild to moderate PPM showed no clinical relevance. All patients revealed improvement in QOL after AVR, while male sex was related to better functioning scores irrespectively of PPM.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/psicologia , Qualidade de Vida , Volume Sistólico/fisiologia , Idoso , Análise de Variância , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Ajuste de Prótese , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
2.
Transplant Proc ; 49(7): 1675-1677, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28838462

RESUMO

Percutaneous coronary intervention in patients with cardiac allograft vasculopathy is burdened with a lot of difficulties. Although they have allowed significant progress in comparison with plain balloon angioplasty and bare metal stents, drug-eluting stents have not fully overcome problems of diffuse lesions and small-vessel disease that are so common in transplant coronary artery disease. There is growing evidence that drug-eluting balloons might be a better choice for patients with small vessel atherosclerotic coronary disease and yet there is no experience with this technology in patients with cardiac allograft vasculopathy. Herein we report a case series of successful percutaneous coronary interventions in patients with cardiac allograft vasculopathy.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença da Artéria Coronariana/cirurgia , Transplante de Coração/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/cirurgia , Adulto , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA