Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39350327

RESUMO

INTRODUCTION: Pericardial effusion, a known complication to implantation of cardiac implantable electronic devices (CIED), may cause life-threatening cardiac tamponade. Limited knowledge is available about risk factors for clinically relevant procedural pericardial effusion. The aim is to identify the patient- and procedure-related risk factors associated with clinically relevant procedural pericardial effusion. METHOD: A nationwide observational cohort study based on data on 55 121 patients from the Danish Pacemaker Register between 2000 and 2018. We defined a clinically relevant procedural pericardial effusion related to the implantation if it occurred within 90 days after the primary CIED-procedure. Prespecified risk factors were analysed by multivariable logistic regression models to estimate the association with pericardial effusion. RESULTS: There were 115 (0.21%) patients diagnosed with clinically relevant procedural pericardial effusion, with a median age of 75 years and 38.3% were females. Of these, 80.9% lead to a subsequent pericardiocentesis procedure. In adjusted logistic regression analysis, an increased risk of clinically relevant pericardial effusion was associated with female sex (OR:1.49 [95%CI: 1.03-2.16]), heart failure (OR:1.54 [95%CI: 1.06-2.23]), previous cardiac surgery (OR:1.63 [95%CI: 1.05-2.55]), CRT-device (OR:2.05 [95%CI: 1.23-3.41]), tertiary-centres (OR:1.8 [95%CI: 1.18-2.73]), increased procedural volume per year (>1000) (OR:1.85 [95%CI: 1.03-3.30]), indication of device-implantation (atrioventricular block) (OR:2.37 [95CI: 1.45-3.87]), and increasing number of leads implanted (two leads (OR:2.39 [95%CI: 1.43-4.00]), three leads (OR:4.77 [95%CI: 2.50-9.10])). CONCLUSION: Clinically relevant procedural pericardial effusion is a rare complication after CIED-implantation in Denmark. This study reveals important patient- and procedure-related risk factors associated with clinically relevant procedural pericardial effusion.

2.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39345160

RESUMO

AIMS: The decisions about placing an ICD in a child are more difficult than in an adult due to longer expected lifespan and the complication risk. Young patients gain the most years from ICDs, despite higher risk of device-related complications. The secondary prevention ICD indication is clear, and device is implanted regardless of potential complications. For primary prevention, risk of sudden cardiac death and complications need to be evaluated. We aimed to compare outcomes for primary and secondary prevention ICDs. METHODS AND RESULTS: Retrospective nationwide cohort study including paediatric patients identified from the Danish ICD registry with ICD implanted at an age ≤ 15 from 1982-21. Demographics, complications (composite of device-related infections or lead-failure requiring re-operation, mortality because of arrhythmia, or unknown cause), and mortality were retrieved from medical charts. Endpoint was appropriate therapy (shock or anti-tachycardia pacing for ventricular tachycardia or fibrillation). Of 72 receiving an ICD, the majority had channelopathies (n = 34) or structural heart diseases (n = 28). ICDs were implanted in 23 patients for primary prevention and 49 for secondary prevention, at median ages of 13.8 and 11.6 years (P-value 0.01), respectively. Median follow-up was 9.0 (interquartile ranges: 4.7-13.5) years. The 10-year cumulative incidence of first appropriate therapy was 70%, with complication and inappropriate therapy rates at 41% and 15%, respectively. No difference was observed between prevention groups for all outcomes. Six patients died during follow-up. CONCLUSION: In children, two-thirds are secondary prevention ICDs. Children have higher appropriate therapy and complication rates than adults, while the inappropriate therapy rate was low.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Prevenção Primária , Sistema de Registros , Prevenção Secundária , Humanos , Masculino , Criança , Estudos Retrospectivos , Prevenção Secundária/métodos , Adolescente , Feminino , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Dinamarca/epidemiologia , Resultado do Tratamento , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Fatores de Risco , Pré-Escolar , Taquicardia Ventricular/terapia , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Fatores Etários , Arritmias Cardíacas/terapia , Arritmias Cardíacas/mortalidade , Fibrilação Ventricular/prevenção & controle , Fibrilação Ventricular/terapia , Fibrilação Ventricular/mortalidade , Medição de Risco
3.
Eur Heart J ; 44(9): 752-761, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36433808

RESUMO

AIMS: The present study aimed to determine the association between Type 2 diabetes mellitus (T2DM) and third-degree (complete) atrioventricular block. METHODS AND RESULTS: This nationwide nested case-control study included patients older than 18 years, diagnosed with third-degree atrioventricular block between 1 July 1995 and 31 December 2018. Data on medication, comorbidity, and outcomes were collected from Danish registries. Five controls, from the risk set of each case of third-degree atrioventricular block, were matched on age and sex to fit a Cox regression model with time-dependent exposure and time-dependent covariates. Subgroup analysis was conducted with Cox regression models for each subgroup. We located 25 995 cases with third-degree atrioventricular block that were matched with 130 004 controls. The mean age was 76 years and 62% were male. Cases had more T2DM (21% vs. 11%), hypertension (69% vs. 50%), atrial fibrillation (25% vs. 10%), heart failure (20% vs. 6.3%), and myocardial infarction (19% vs. 9.2%), compared with the control group. In Cox regression analysis, adjusting for comorbidities and atrioventricular nodal blocking agents, T2DM was significantly associated with third-degree atrioventricular block (hazard ratio: 1.63, 95% confidence interval: 1.57-1.69). The association remained in several subgroup analyses of diseases also suspected to be associated with third-degree atrioventricular block. There was a significant interaction with comorbidities of interest including hypertension, atrial fibrillation, heart failure, and myocardial infarction. CONCLUSION: In this nationwide study, T2DM was associated with a higher rate of third-degree atrioventricular block compared with matched controls. The association remained independent of atrioventricular nodal blocking agents and other comorbidities known to be associated with third-degree atrioventricular block.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Hipertensão , Infarto do Miocárdio , Humanos , Masculino , Idoso , Feminino , Estudos de Casos e Controles , Sistema de Registros , Dinamarca
4.
Circulation ; 145(10): 754-764, 2022 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-34889650

RESUMO

BACKGROUND: Identification of patients with nonischemic cardiomyopathy who may benefit from prophylactic implantation of a cardioverter-defibrillator. We hypothesized that periodic repolarization dynamics (PRD), a marker of repolarization instability associated with sympathetic activity, could be used to identify patients who will benefit from prophylactic implantable cardioverter defibrillator (ICD) implantation. METHODS: We performed a post hoc analysis of DANISH (Danish ICD Study in Patients With Dilated Cardiomyopathy), in which patients with nonischemic cardiomyopathy, left ventricular ejection fraction (LVEF) ≤35%, and elevated NT-proBNP (N-terminal probrain natriuretic peptides) were randomized to ICD implantation or control group. Patients were included in the PRD substudy if they had a 24-hour Holter monitor recording at baseline with technically acceptable ECG signals during the night hours (00:00-06:00). PRD was assessed using wavelet analysis according to previously validated methods. The primary end point was all-cause mortality. Cox regression models were adjusted for age, sex, NT-proBNP, estimated glomerular filtration rate, LVEF, atrial fibrillation, ventricular pacing, diabetes, cardiac resynchronization therapy, and mean heart rate. We proposed PRD ≥10 deg2 as an exploratory cut-off value for ICD implantation. RESULTS: A total of 748 of the 1116 patients in DANISH qualified for the PRD substudy. During a mean follow-up period of 5.1±2.0 years, 82 of 385 patients died in the ICD group and 85 of 363 patients died in the control group (P=0.40). In Cox regression analysis, PRD was independently associated with mortality (hazard ratio [HR], 1.28 [95% CI, 1.09-1.50] per SD increase; P=0.003). PRD was significantly associated with mortality in the control group (HR, 1.51 [95% CI, 1.25-1.81]; P<0.001) but not in the ICD group (HR, 1.04 [95% CI, 0.83-1.54]; P=0.71). There was a significant interaction between PRD and the effect of ICD implantation on mortality (P=0.008), with patients with higher PRD having greater benefit in terms of mortality reduction. ICD implantation was associated with an absolute mortality reduction of 17.5% in the 280 patients with PRD ≥10 deg2 (HR, 0.54 [95% CI, 0.34-0.84]; P=0.006; number needed to treat=6), but not in the 468 patients with PRD <10 deg2 (HR, 1.17 [95% CI, 0.77-1.78]; P=0.46; P for interaction=0.01). CONCLUSIONS: Increased PRD identified patients with nonischemic cardiomyopathy in whom prophylactic ICD implantation led to significant mortality reduction.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Desfibriladores Implantáveis , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Dinamarca/epidemiologia , Humanos , Volume Sistólico , Função Ventricular Esquerda
5.
Circulation ; 145(5): 321-329, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34779221

RESUMO

BACKGROUND: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) showed noninferiority of subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous implantable cardioverter defibrillator (TV-ICD) with regard to inappropriate shocks and complications. In contrast to TV-ICD, S-ICD cannot provide antitachycardia pacing for monomorphic ventricular tachycardia. This prespecified secondary analysis evaluates appropriate therapy and whether antitachycardia pacing reduces the number of appropriate shocks. METHODS: The PRAETORIAN trial was an international, investigator-initiated randomized trial that included patients with an indication for implantable cardioverter defibrillator (ICD) therapy. Patients with previous ventricular tachycardia <170 bpm or refractory recurrent monomorphic ventricular tachycardia were excluded. In 39 centers, 849 patients were randomized to receive an S-ICD (n=426) or TV-ICD (n=423) and were followed for a median of 49.1 months. ICD programming was mandated by protocol. Appropriate ICD therapy was defined as therapy for ventricular arrhythmias. Arrhythmias were classified as discrete episodes and storm episodes (≥3 episodes within 24 hours). Analyses were performed in the modified intention-to-treat population. RESULTS: In the S-ICD group, 86 of 426 patients received appropriate therapy, versus 78 of 423 patients in the TV-ICD group, during a median follow-up of 52 months (48-month Kaplan-Meier estimates 19.4% and 17.5%; P=0.45). In the S-ICD group, 83 patients received at least 1 shock, versus 57 patients in the TV-ICD group (48-month Kaplan-Meier estimates 19.2% and 11.5%; P=0.02). Patients in the S-ICD group had a total of 254 shocks, compared with 228 shocks in the TV-ICD group (P=0.68). First shock efficacy was 93.8% in the S-ICD group and 91.6% in the TV-ICD group (P=0.40). The first antitachycardia pacing attempt successfully terminated 46% of all monomorphic ventricular tachycardias, but accelerated the arrhythmia in 9.4%. Ten patients with S-ICD experienced 13 electrical storms, versus 18 patients with TV-ICD with 19 electrical storms. Patients with appropriate therapy had an almost 2-fold increased relative risk of electrical storms in the TV-ICD group compared with the S-ICD group (P=0.05). CONCLUSIONS: In this trial, no difference was observed in shock efficacy of S-ICD compared with TV-ICD. Although patients in the S-ICD group were more likely to receive an ICD shock, the total number of appropriate shocks was not different between the 2 groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/normas , Idoso , Arritmias Cardíacas/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
6.
J Card Fail ; 29(6): 883-892, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36708755

RESUMO

BACKGROUND: Patients with nonischemic systolic heart failure have an increased risk of malignant ventricular arrhythmias and sudden cardiovascular death. Because the risk is less pronounced than for patients with ischemic cause of heart failure more discriminating tools are needed to identify patients most likely to benefit from implantable cardioverter-defibrillator (ICD) implantation. Right ventricular (RV) dysfunction is associated with a worse prognosis, but whether RV free wall strain (RV-FWS) measured with echocardiography can identify the patients most likely to benefit from ICD implantation is not known. METHODS AND RESULTS: In this extended follow-up analysis of the Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischemic Systolic Heart Failure on Mortality (DANISH) trial, RV-FWS was measured with echocardiography in 445 patients before randomization. RV dysfunction was defined as an RV-FWS of greater than -20%. The primary end point was all-cause mortality. The median RV-FWS was -18% (quartiles -23% to -14%), and RV dysfunction was measured in 255 patients (57%). During a median follow-up of 5.7 years, 170 patients (38%) died. There was a statistically significant interaction between RV dysfunction and the effect of ICD implantation (P = .003), also after adjusting for known cardiovascular risk factors (P = .01). ICD implantation significantly decreased all-cause mortality in patients with RV dysfunction (hazard ratio 0.54, 95% confidence interval 0.36-0.80, P = .002), but not in patients with normal RV function (hazard ratio 1.34, 95% confidence interval 0.84-2.12, P = .22). CONCLUSIONS: In patients with nonischemic systolic heart failure, RV dysfunction on echocardiography was associated with a greater effect of ICD implantation and could be used to select patients with benefit from ICD treatment.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca Sistólica , Humanos , Insuficiência Cardíaca Sistólica/diagnóstico por imagem , Insuficiência Cardíaca Sistólica/terapia , Morte Súbita Cardíaca/etiologia , Coração , Desfibriladores Implantáveis/efeitos adversos , Prognóstico
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37129985

RESUMO

AIMS: Reduced psychological health is associated with adverse patient outcomes and higher mortality. We aimed to examine if a Brugada syndrome (BrS) diagnosis and symptomatic disease presentation were associated with an increased risk of new-onset depression or anxiety and all-cause mortality. METHODS AND RESULTS: All Danish patients diagnosed with BrS (2006-2018) with no history of psychiatric disease and available for ≥6 months follow-up were identified using nationwide registries and followed for up to 5 years after diagnosis. The development of clinical depression or anxiety was evaluated using the prescription of medication and diagnosis codes. Factors associated with developing new-onset depression or anxiety were determined using a multivariate Cox proportional hazards regression model. Disease manifestation was categorized as symptomatic (aborted cardiac arrest, ventricular tachycardia, or syncope) or asymptomatic/unspecified at diagnosis. A total of 223 patients with BrS and no history of psychiatric disease were identified (72.6% male, median age at diagnosis 46 years, 45.3% symptomatic). Of these, 15.7% (35/223) developed new-onset depression or anxiety after BrS diagnosis (median follow-up 5.0 years). A greater proportion of symptomatic patients developed new-onset depression or anxiety compared with asymptomatic patients [21/101 (20.8%) and 14/122 (11.5%), respectively, P = 0.08]. Symptomatic disease presentation (HR 3.43, 1.46-8.05) and older age (lower vs. upper tertile: HR 4.41, 1.42-13.63) were significantly associated with new-onset depression or anxiety. All-cause mortality in this group of patients treated according to guidelines was low (n = 4, 1.8%); however, 3/4 developed depression or anxiety before death. CONCLUSION: Approximately, one-sixth of patients with BrS developed new-onset depression or anxiety following a diagnosis of BrS. Symptomatic BrS disease manifestation was significantly associated with new-onset depression or anxiety.


Assuntos
Síndrome de Brugada , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/complicações , Depressão/diagnóstico , Depressão/epidemiologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia/métodos , Medição de Risco/métodos , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Dinamarca/epidemiologia
8.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335977

RESUMO

AIMS: To date, potential differences in outcomes for immigrants and non-immigrants with a cardiac resynchronization therapy (CRT), in a European setting, remain underutilized and unknown. Hence, we examined the efficacy of CRT measured by heart failure (HF)-related hospitalizations and all-cause mortality among immigrants and non-immigrants. METHODS AND RESULTS: All immigrants and non-immigrants who underwent first-time CRT implantation in Denmark (2000-2017) were identified from nationwide registries and followed for up to 5 years. Differences in HF related hospitalizations and all-cause mortality were evaluated by Cox regression analyses. From 2000 to 2017, 369 of 10 741 (3.4%) immigrants compared with 7855 of 223 509 (3.5%) non-immigrants with a HF diagnosis underwent CRT implantation. The origins of the immigrants were Europe (61.2%), Middle East (20.1%), Asia-Pacific (11.9%), Africa (3.5%), and America (3.3%). We found similar high uptake of HF guideline-directed pharmacotherapy before and after CRT and a consistent reduction in HF-related hospitalizations the year before vs. the year after CRT (61% vs. 39% for immigrants and 57% vs. 35% for non-immigrants). No overall difference in 5-year mortality among immigrants and non-immigrants was seen after CRT [24.1% and 25.8%, respectively, P-value = 0.50, hazard ratio (HR) = 1.2, 95% confidence interval (CI): 0.8-1.7]. However, immigrants of Middle Eastern origin had a higher mortality rate (HR = 2.2, 95% CI: 1.2-4.1) compared with non-immigrants. Cardiovascular causes were responsible for the majority of deaths irrespective of immigration status (56.7% and 63.9%, respectively). CONCLUSION: No overall differences in efficacy of CRT in improving outcomes between immigrants and non-immigrants were identified. Although numbers were low, a higher mortality rate among immigrants of Middle Eastern origin was identified compared with non-immigrants.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Modelos de Riscos Proporcionais , Desfibriladores Implantáveis/efeitos adversos
9.
Pacing Clin Electrophysiol ; 46(7): 721-728, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37120825

RESUMO

BACKGROUND: Reduced systolic myocardial function in the inferior region of the left ventricle has been suggested to be associated with malignant arrhythmias. We tested this hypothesis in patients with non-ischemic heart failure. METHODS: Patients with non-ischemic heart failure (left ventricular ejection fraction [LVEF] < 35%) were evaluated by 2D-speckle-tracking echocardiography. The regional longitudinal strain was calculated for each of the six left ventricular walls. The reduced regional function was defined as strain below the median. The outcome was a composite of sudden cardiac death, admission with sustained ventricular arrhythmia, resuscitated cardiac arrest, and appropriate therapy from a primary prophylactic implantable cardioverter defibrillator. Time-to-first-event analysis was performed using a Cox model. RESULTS: From two centers, 401 patients were included (median age: 63 years, 72% male) with a median LVEF of 25% (interquartile range [IQR] 20;30), and a median inferior wall strain of -9.0% (-12.5; -5.4). During a median follow-up of 4.0 years, 52 outcomes occurred. After multivariate adjustment for clinical and electrocardiographic parameters, inferior wall strain was independently associated with the outcome (HR 2.50 [1.35; 4.62], p = .003). No independent association was found between the composite outcome and reduced strain in any of the other left ventricular walls, Global Longitudinal Strain (HR 1.66 [0.93; 2.98], p = .09), or LVEF (HR 1.33 [0.75; 2.33], p = .33). CONCLUSIONS: Below median strain in the left ventricular inferior region was independently associated with a 2.5-fold increase in the risk of malignant arrhythmias and sudden cardiac death in patients with non-ischemic heart failure.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Função Ventricular Esquerda , Volume Sistólico , Fatores de Risco , Valor Preditivo dos Testes , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/complicações
10.
Eur Heart J ; 43(47): 4946-4956, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36263789

RESUMO

AIMS: Cardiac implantable electronic device (CIED) infection is a severe complication to modern management of cardiac arrhythmias. The CIED type and the type of surgery are recognized as risk factors for CIED infections, but knowledge of patient-related risk factors is scarce. This study aimed to identify lifelong patient-related risk factors for CIED infections. METHODS AND RESULTS: Consecutive Danish patients undergoing a CIED implantation or reoperation between January 1996 and April 2018 were included. The cohort consisted of 84 429 patients undergoing 108 494 CIED surgeries with a combined follow-up of 458 257 CIED-years. A total of 1556 CIED explantations were classified as either pocket (n = 1022) or systemic CIED infection (n = 534). Data were cross-linked with records from the Danish National Patient Registry and the Danish National Prescription Registry. Using multiple-record and multiple-event per subject proportional hazard analysis, specific patient-related risk factors were identified but with several variations amongst the subtypes of CIED infection. CIED reoperations were associated with the highest risk of pocket CIED infection but also CIED type, young age, and prior valvular surgery [hazard ratio (HR): 1.62, 95% confidence interval (CI): 1.29-2.04]. Severe renal insufficiency/dialysis (HR: 2.40, 95% CI: 1.65-3.49), dermatitis (HR: 2.80, 95% CI: 1.92-4.05), and prior valvular surgery (HR: 2.09, 95% CI: 1.59-2.75) were associated with the highest risk of systemic CIED infections. Congestive heart failure, ischaemic heart disease, malignancy, chronic obstructive pulmonary disease, and temporary pacing were not significant at multivariate analysis. CONCLUSION: Specific comorbidities and surgical procedures were associated with a higher risk of CIED infections but with variations amongst pocket and systemic CIED infection. Pocket CIED infections were associated with CIED reoperations, young age and more complex type of CIED, whereas systemic CIED infections were associated with risk factors predisposing to bacteraemia.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Incidência , Fatores de Risco , Eletrônica , Dinamarca/epidemiologia , Estudos Retrospectivos
11.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-36030464

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Humanos , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos
12.
Heart Lung Circ ; 32(3): 364-372, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36513581

RESUMO

AIM: The COVID-19 pandemic resulted in a significant decrease in the number of hospital admissions for severe emergent cardiovascular diseases during lockdowns worldwide. This study aimed to determine the impact of both the first and the second Danish nationwide lockdown on the implantation rate of cardiac implantable electronic devices (CIEDs). METHODS: We retrospectively analysed the number of CIED implantations performed in Denmark and stratified them into 3-week intervals. RESULTS: The total number of de novo CIED implantations decreased during the first lockdown by 15.5% and during the second by 5.1%. Comparing each 3-week interval using rate ratios, a significant decrease in the daily rates of the total number of de novo and replacement CIEDs (0.82, 95% CI [0.70, 0.96]), de novo CIEDs only (0.82, 95% CI [0.69, 0.98]), and non-acute pacemaker implantations (0.80, 95% CI [0.63, 0.99]) was observed during the first interval of the first lockdown. During the second lockdown (third interval), a significant decrease was seen in the daily rates of de novo CIEDs (0.73, 95% CI [0.55, 0.97]), and of pacemakers in total during both the second (0.78, 95% CI [0.62, 0.97]) and the third (0.60, 95% CI [0.42, 0.85]) intervals. Additionally, the daily rates of acute pacemaker implantation decreased during the second interval (0.47, 95% CI [0.27, 0.79]) and of non-acute implantation during the third interval (0.57, 95% CI [0.38, 0.84]). A significant increase was observed in the number of replacement procedures during the first interval of the second lockdown (1.70, 95% CI [1.04, 2.85]). CONCLUSIONS: Our study found only modest changes in CIED implantations in Denmark during two national lockdowns.


Assuntos
COVID-19 , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Estudos Retrospectivos , Pandemias , Fatores de Risco , COVID-19/epidemiologia , Controle de Doenças Transmissíveis
13.
Eur Heart J ; 42(35): 3529-3537, 2021 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-33954626

RESUMO

AIMS: Patients are restricted from driving following implantable cardioverter defibrillator (ICD) implantation or shock. We sought to investigate how many patients are aware of, and adhere to, the driving restrictions, and what proportion experience an ICD shock or other cardiac symptoms while driving. METHODS AND RESULTS: We performed a nationwide survey of all living Danish residents 18 years or older who received a first-time ICD between 2013 and 2016 (n = 3913) and linked their responses with nationwide registers. Of 2741 respondents (47% primary prevention, 83% male, median age 67 years), 2513 (92%) held a valid driver's license at ICD implantation, 175 (7%) of whom had a license for professional driving. Many drivers were unaware of driving restrictions: primary prevention 58%; secondary prevention 36%; post-appropriate shock 28%; professional drivers 55%. Almost all (94%) resumed non-professional driving after ICD implantation, more than one-third during the restricted period; 35% resumed professional driving. During a median follow-up of 2.3 years, 5 (0.2%) reported receiving an ICD shock while driving, one of which resulted in a traffic accident. The estimated risk of harm was 0.0002% per person-year. CONCLUSION: In this nationwide study, many ICD patients were unaware of driving restrictions, and more than one third resumed driving during a driving restriction period. However, the rate of reported ICD shocks while driving was very low.


Assuntos
Condução de Veículo , Desfibriladores Implantáveis , Acidentes de Trânsito , Idoso , Morte Súbita Cardíaca , Feminino , Humanos , Masculino , Prevenção Primária , Inquéritos e Questionários
14.
Am Heart J ; 232: 61-70, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33144085

RESUMO

BACKGROUND: Atrial fibrillation (AF) in heart failure (HF) patients has been associated with a worse outcome. Similarly, excessive supraventricular ectopic activity (ESVEA) has been linked to development of AF, stroke, and death. This study aimed to investigate AF and ESVEA's association with outcomes and effect of prophylactic implantable cardioverter defibrillator (ICD) implantation in nonischemic HF patients. METHODS: A total of 850 patients with nonischemic HF, left ventricle ejection fraction ≤35%, and elevated N-terminal pro-brain natriuretic peptides underwent 24 hours Holter recording. The presence of AF (≥30 seconds) and ESVEA (≥30 supraventricular ectopic complexes (SVEC) per hour or run of SVEC ≥20 beats) were registered. Outcomes were all-cause mortality, cardiovascular death (CVD), and sudden cardiac death (SCD). RESULTS: AF was identified in 188 patients (22%) and ESVEA in 84 patients (10%). After 4 years and 11 months of follow-up, a total of 193 patients (23%) had died. AF was associated with all-cause mortality (hazard ratio [HR] 1.44; confidence interval [CI] 1.04-1.99; P = .03) and CVD (HR 1.59; CI 1.07-2.36; P = .02). ESVEA was associated with all-cause mortality (HR 1.73; CI 1.16-2.57; P = .0073) and CVD (HR 1.76; CI 1.06-2.92; P = .03). Neither AF nor ESVEA was associated with SCD. ICD implantation was not associated with an improved prognosis for neither AF (P value for interaction = .17), nor ESVEA (P value for interaction = .68). CONCLUSIONS: Both AF and ESVEA were associated with worsened prognosis in nonischemic HF. However, ICD implantation was not associated with an improved prognosis for either group.


Assuntos
Fibrilação Atrial/fisiopatologia , Complexos Atriais Prematuros/fisiopatologia , Morte Súbita Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Mortalidade , Idoso , Fibrilação Atrial/complicações , Complexos Atriais Prematuros/complicações , Doenças Cardiovasculares/mortalidade , Causas de Morte , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Dinamarca , Eletrocardiografia Ambulatorial , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Volume Sistólico
15.
Europace ; 23(4): 587-595, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33257933

RESUMO

AIMS: Improved risk stratification to identify non-ischaemic heart failure patients who will benefit from primary prophylactic implantable cardioverter-defibrillator (ICD) is needed. We examined the potential of ventricular arrhythmia to identify patients who could benefit from an ICD. METHODS AND RESULTS: A total of 850 non-ischaemic systolic heart failure patients with left ventricle ≤35% and elevated N-terminal pro-brain natriuretic peptides had a 24-h Holter monitor recording performed. We examined present non-sustained ventricular tachycardia (NSVT), defined as ≥3 consecutive premature ventricular contractions (PVCs) with a rate of ≥100/min, and number of PVCs per hour stratified into low (<30) and high burden (≥30) groups. Outcome measures were overall mortality, sudden cardiac death (SCD), and cardiovascular death (CVD). In total, 193 patients died, 49 from SCD and 125 from CVD. Non-sustained ventricular tachycardia (365 patients) was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.47; 95% confidence interval (CI) 1.07-2.03; P = 0.02] and to CVD (HR 1.89; CI 1.25-2.87; P = 0.003). High burden PVC (352 patients) was associated with increased all-cause mortality (HR1.38; CI 1.00-1.90; P = 0.046) and with CVD (HR 1.78; CI 1.19-2.66; P = 0.005). There was no statistically significant association with SCD for neither NSVT nor PVC. In interaction analyses, neither NSVT (P = 0.56) nor high burden of PVC (P = 0.97) was associated with survival benefit from ICD implantation. CONCLUSION: Ventricular arrhythmia in non-ischaemic heart failure patients was associated with a worse prognosis but could not be used to stratify patients to ICD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca Sistólica , Insuficiência Cardíaca , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Dinamarca/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Prevalência , Prognóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia
16.
Scand Cardiovasc J ; 55(4): 205-212, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33749460

RESUMO

Objectives. Implantable cardioverter defibrillator (ICD) implantation in patients resuscitated from out-of-hospital cardiac arrest (OHCA) due to acute myocardial infarction (AMI) is controversial. Design. Consecutive OHCA-survivors due to AMI from two Danish tertiary heart centers from 2007 to 2011 were included. Predictors of ICD-implantation, ICD-therapy and long-term survival (5 years) were investigated. Patients with and without ICD-implantation during the index hospital admission were included (later described as early ICD-implantation). Patients with an ICD after hospital discharge were censored from further analyses at time of implantation. Results. We identified 1,457 consecutive OHCA-patients, and 292 (20%) of the cohort met the inclusion criteria. An ICD was implanted during hospital admission in 78 patients (27%). STEMI and successful revascularization were inversely and independently associated with ICD-implantation (ORSTEMI = 0.37, 95% CI: 0.14-0.94, ORrevasc = 0.11, 0.03-0.36) whereas age, sex, LVEF <35%, comorbidity burden or shockable first OHCA-rhythm were not associated with ICD-implantation. Appropriate ICD-shock therapy during the follow-up period was noted in 15% of patients (n = 12). Five-year mortality-rate was significantly lower in ICD-patients (18% vs. 28%, plogrank = 0.02), which was persistent after adjustment for prognostic factors (HR = 0.44 (95% CI: 0.23-0.88)). This association was no longer found when using first event (death or appropriate shock whatever came first) as outcome variable (plogrank = 0.9). Conclusions. Mortality after OHCA due to AMI was significantly lower in patients with early ICD-implantation after adjustment for prognostic factors. When using appropriate shock and death as events, ICD-patients had similar outcome as patients without an ICD, which may suggest a survival benefit due to appropriate device therapy.


Assuntos
Síndrome Coronariana Aguda , Desfibriladores Implantáveis , Parada Cardíaca , Sobreviventes , Síndrome Coronariana Aguda/cirurgia , Desfibriladores Implantáveis/estatística & dados numéricos , Parada Cardíaca/epidemiologia , Humanos , Análise de Sobrevida , Sobreviventes/estatística & dados numéricos
17.
Europace ; 22(12): 1830-1840, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33106878

RESUMO

AIMS: To investigate (i) the prevalence of anxiety and depression and (ii) the association between indication for implantable cardioverter-defibrillator (ICD) implantation and sex in relation to anxiety and depression up to 24 months' follow-up. METHODS AND RESULTS: Patients with a first-time ICD, participating in the national, multi-centre, prospective DEFIB-WOMEN study (n = 1496; 18% women) completed the Hospital Anxiety and Depression Scale at baseline, 3, 6, 12, and 24 months. Data were analysed using linear mixed modelling for longitudinal data. Patients with a secondary prophylactic indication (SPI) had higher mean anxiety scores than patients with a primary prophylactic indication (PPI) at baseline, 3, and 12 months and higher mean depression scores at all-time points, except at 24 months. Women had higher mean anxiety scores as compared to men at all-time points; however, only higher mean depression scores at baseline. Overall, women with SPI had higher anxiety and depression symptom scores than men with SPI. Symptoms decreased over time in both women and men. From baseline to follow-up, the prevalence of anxiety (score ≥8) was highest in patients with SPI (13.3-20.2%) as compared to patients with PPI (range 10.0-14.7%). The prevalence of depression was stable over the follow-up period in both groups (range 8.5-11.1%). CONCLUSION: Patients with a SPI reported higher anxiety and depression scores as compared to patients with PPI. Women reported higher anxiety scores than men, but only higher depression scores at baseline. Women with SPI reported the highest anxiety and depression scores overall.


Assuntos
Desfibriladores Implantáveis , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Dinamarca/epidemiologia , Depressão/diagnóstico , Depressão/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Estudos Prospectivos
18.
Europace ; 22(7): 1097-1102, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32447372

RESUMO

AIMS: Commonly, a dysfunctional defibrillator lead is abandoned and a new lead is implanted. Long-term follow-up data on abandoned leads are sparse. We aimed to investigate the incidence and reasons for extraction of abandoned defibrillator leads in a nationwide cohort and to describe extraction procedure-related complications. METHODS AND RESULTS: All abandoned transvenous defibrillator leads were identified in the Danish Pacemaker and ICD Register from 1991 to 2019. The event-free survival of abandoned defibrillator leads was studied, and medical records of patients with interventions on abandoned defibrillator leads were audited for procedure-related data. We identified 740 abandoned defibrillator leads. Meantime from implantation to abandonment was 7.2 ± 3.8 years with mean patient age at abandonment of 66.5 ± 13.7 years. During a mean follow-up after abandonment of 4.4 ± 3.1 years, 65 (8.8%) abandoned defibrillator leads were extracted. Most frequent reason for extraction was infection (pocket and systemic) in 41 (63%) patients. Procedural outcome after lead extraction was clinical success in 63 (97%) patients. Minor complications occurred in 3 (5%) patients, and major complications in 1 (2%) patient. No patient died from complication to the procedure during 30-day follow-up after extraction. CONCLUSION: More than 90% of abandoned defibrillator leads do not need to be extracted during long-term follow-up. The most common indication for extraction is infection. Abandoned defibrillator leads can be extracted with high clinical success rate and low risk of major complications at high-volume centres.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Seguimentos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
19.
J Electrocardiol ; 58: 33-36, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31710872

RESUMO

BACKGROUND: Following an observation of pacing markers being placed after the beginning of the paced QRS complex when using the analyzer module 2290 of the Medtronic 2090 programmer, we decided to determine the delay between the EGM and the ECG channels and comparing it to the St Jude Merlin® programmer. METHODS: We obtained ECG lead I simultaneously from both the ECG cable and by attaching the atrial clamps of the EGM cable on the left and right shoulder. We were then able to directly measure any delay. Then we compared measurements of start QRS to LV sense (qLV) in patients implanted with CRT in the last year where we had data on qLV at implant and at 6-month follow-up. At implant qLV was measured by the analyzer modules and at 6-month follow-up, it was measured in the pacing devices. RESULTS: We found that the delay between the EGM and ECG channels was 59 ±â€¯4 ms in the Medtronic analyzer (ECG first) and 4 ±â€¯3 ms in the St Jude analyzer (EGM first). In 16 CRT patients where the Medtronic analyzer had been used, the difference between qLV at implant and qLV at 6 months was 60 ±â€¯27 ms whereas this difference was 2 ±â€¯28 ms in 34 CRT patients where the St Jude analyzer had been used (p < 10-7). CONCLUSION: There is a delay of about 60 ms between the EGM and ECG channels of 2290 analyzer module of the Medtronic 2090 programmer making it unsuitable for determining timing measurements between QRS and EGM.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
20.
Eur Heart J ; 40(23): 1862-1869, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-31155647

RESUMO

AIMS: Device-related infection (DRI) is a severe complication to cardiac implantable electronic devices (CIED) therapy. Device-related infection incidence and its risk factors differ between previous studies. We aimed to define the long-term incidence and incidence rates of DRI for different types of CIEDs in the complete Danish device-cohort and identify patient-, operation- and device-related risk factors for DRI. METHODS AND RESULTS: From the Danish Pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Register, we included consecutive Danish patients undergoing CIED implantation or reoperation from January 1982 to April 2018, resulting in 97 750 patients, 128 045 operations and follow-up of in total 566 275 device years (DY). We identified 1827 DRI causing device removals. Device-related infection incidence during device lifetime was 1.19% (1.12-1.26) for PM, 1.91% (1.71-2.13) for ICD, 2.18% (1.78-2.64) for cardiac resynchronization therapy (CRT)-pacemakers (CRT-P), and 3.35% (2.92-3.83) for CRT-defibrillators (CRT-D). Incidence rates in de novo implantations were 2.04/1000 DY for PM, 3.84 for ICD, 4.38 for CRT-P, and 6.76 for CRT-D. Using multiple-record and multiple-event per subject proportional hazard analysis, we identified implantation of complex devices (ICD and CRT), reoperations, prior DRI, male sex, and younger age as significantly associated with higher DRI risk. CONCLUSION: Overall risk of infection was low in PM implantations but considerably higher in CRT systems and after reinterventions. These data support the importance of evaluating all patients considered for CIED therapy thoroughly, in order to identify potential modifiable risk factors and reduce the risk of early reoperations.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/estatística & dados numéricos , Dinamarca/epidemiologia , Remoção de Dispositivo , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA