Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ann Ig ; 27(5): 769-76, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26661918

RESUMO

INTRODUCTION: Patient mobility, driven by patient preference is an indirect indicator of perception of hospital quality. Patients' choices depend on their previous healthcare experiences, the reputation of the hospital staff and the network of relationships between the patient, hospital doctors, general practitioners/reference specialists, etc. Therefore, the analysis of patient preferences provides an idea of hospital quality as well as qualitative and quantitative lack of services. The aim of the present research was to describe and analyze patient mobility for bone marrow transplantation regarding the Hospital of Perugia, which represents the second most important structure for bone marrow transplant in Italy. METHODS: Data have been collected from hospital discharge records in the ordinary regime related to the Diagnosis Related Group 481 "bone marrow transplant" since 2000 to 2013. We included autologous and allogenic transplant, in the adult and the child. Analysis of escaped, attracted and resident patients flows was undertaken using Gandy's nomogram which detects, through repeated time investigations, patients' movement inside and outside their catchment area. RESULTS: Between 2000 and 2013, 1782 patients were admitted to hospital with a DRG 481 "bone marrow transplant". Nine hundred and nineteen (51,5%) were resident in Umbria region, 799 (44,8%) in other regions, 64 (0,3%) abroad. Escapes were 158. The high percentage of admissions represented by patients that live out of Umbria, shows a high attractive power of the hospital. For "distant regions" this situation was maintained from 2000 to 2003, with a mild decrease from 2004 and, from 2010, the situation is stable. Only for "bordering regions" the attraction, which was stable up to 2010, seems to decrease. Gandy's nomogram shows also that the hospital was able to satisfy the health needs of the Umbria residents between 2004 and 2009 with a reductions in the escapes; then, in the last four years there is an increase in Umbria residents who seek care outside the catchment area and, in the last two years a reduction in the attraction power also. CONCLUSIONS: During the analyzed period of time, the Hospital of Perugia has been a choice for patients needing a bone marrow transplant. In the last period of the analysis it seems that patients preferences have changed. The increased availability of new hematologic centers explains two phenomena: on the one hand patients tend to not move for the examined DRG, so that there is a reduction in incoming patients from bordering regions; on the other hand the competition to attract patients from the catchment area leads to an increase in the quality of the service.


Assuntos
Transplante de Medula Óssea/métodos , Hospitais/estatística & dados numéricos , Preferência do Paciente , Viagem , Adulto , Transplante de Medula Óssea/estatística & dados numéricos , Criança , Coleta de Dados , Necessidades e Demandas de Serviços de Saúde , Humanos , Itália , Nomogramas , Transplante Autólogo/métodos , Transplante Autólogo/estatística & dados numéricos , Transplante Homólogo/métodos , Transplante Homólogo/estatística & dados numéricos
2.
Anal Chem ; 80(9): 3445-9, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18345691

RESUMO

Contamination of water resources by organochlorine pesticides (OCPs) continues to receive widespread attention because of the increasing concern regarding their high persistence and bioaccumulation. These organic pollutants are not amenable by liquid chromatography (LC) coupled to atmospheric pressure ionization-mass spectrometry, which represents the method of choice for the characterization of pesticide residues in water. Gas chromatography-mass spectrometry provides excellent response for OCPs, but it falls short when complex, multiresidue analyses are required. As recently demonstrated, an efficient EI-based LC-MS interface can generate very good spectra for an extremely wide range of small-medium molecular weight molecules of different polarity and can represent a valid tool in solving the analytical challenge of analyzing OCPs by LC-MS. Based on this assumption, we present a new approach for the determination of 12 OCPs in water samples. The method requires a solid-phase extraction preconcentration step followed by nanoscale liquid chromatography coupled to a direct-electron ionization direct interface (Direct-EI). Direct-EI is a miniaturized interface for efficiently coupling a liquid chromatograph with an EI mass spectrometer. The capability to acquire high-quality EI spectra in a wide range of concentrations, and to operate in selected ion monitoring mode during analyses, allowed a precise quantification of the OCPs. Without sample injection enrichment, limits of detection of the method span from 0.044 to 0.33 microg/L, corresponding to an instrumental detection limit of 120-850 pg. In addition, a careful evaluation of the matrix effect showed that the response of the Direct-EI interface was never affected by sample interferences. From our knowledge, the proposed method represents the first application of LC-MS in the analysis of organochlorine pesticides.


Assuntos
Cromatografia Líquida/métodos , Hidrocarbonetos Clorados/análise , Espectrometria de Massas/métodos , Praguicidas/análise , Poluentes Químicos da Água/análise
3.
J Clin Invest ; 102(8): 1627-33, 1998 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-9788977

RESUMO

Corticosteroid-induced osteoporosis is the most common secondary cause of osteoporosis. We conducted a 12-mo, randomized clinical trial of human parathyroid hormone 1-34 (hPTH 1-34) in postmenopausal women (mean age was 63 yr) with osteoporosis who were taking corticosteroids and hormone replacement therapy. Response to the treatment was assessed with bone mineral density (BMD) measurements of the lumbar spine by quantitative computed tomography (QCT); BMD measurements of the lumbar spine, hip, and forearm by dual-energy x-ray absorptiometry (DXA); and biochemical markers of bone turnover. The mean (+/-SE) changes in BMD of the lumbar spine by QCT and DXA in the PTH group were 35+/-5.5% and 11+/-1.4%, respectively, compared with a relatively small change of 1.7+/-1.8% and 0+/-0.9% in the estrogen-only group. The differences in mean percentage between the groups at 1 yr were 33.5% for the lumbar spine by QCT (P < 0.001) and 9.8% for the lumbar spine by DXA (P < 0.001). The changes in the hip and forearm were not significantly different between or within the groups. During the first 3 mo of PTH treatment, markers of bone formation increased to nearly 150%, whereas markers of bone resorption increased only 100%, suggesting an early uncoupling of bone turnover in favor of formation. These results suggest that parathyroid hormone dramatically increases bone mass in the central skeleton of postmenopausal women with corticosteroid- induced osteoporosis who are taking hormone replacement.


Assuntos
Corticosteroides/efeitos adversos , Osteoporose/induzido quimicamente , Osteoporose/tratamento farmacológico , Pós-Menopausa/metabolismo , Teriparatida/uso terapêutico , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Reabsorção Óssea , Calcificação Fisiológica , Estrogênios/uso terapêutico , Feminino , Humanos , Pessoa de Meia-Idade , Fraturas da Coluna Vertebral , Tomografia , Urina/química
4.
J Bone Miner Res ; 15(5): 944-51, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10804025

RESUMO

Glucocorticoid-induced osteoporosis is the most common secondary cause of osteoporosis. In this 24-month study, we report changes in bone turnover and bone mass after 12 months of daily injections of human parathyroid hormone 1-34 [hPTH(1-34)] and 12 months off treatment in postmenopausal women (mean age, 63 years) with osteoporosis treated with glucocorticoid and hormone replacement therapy. Response to the treatment was assessed with bone mineral density (BMD) measurements of the lumbar spine by quantitative computed tomography (QCT); BMD measurements of the lumbar spine, hip, and forearm by dual-energy X-ray absorptiometry (DXA); and biochemical markers of bone turnover. The mean (+/-SEM) change in BMD of the lumbar spine by QCT and DXA in the PTH group at 24 months was 45.9+/-6.4% and 12.6+/-2.2% (p < 0.001). The change in total hip and femoral neck BMD was not significant at 12 months but increased to 4.7+/-0.9% (p < 0.01) and 5.2+/-1.3% at 24 months, respectively, as compared with a relatively small change of 1.3+/-0.9% and 2.6+/-1.7% in the estrogen-only group. The mean percent differences in BMD of the lumbar spine by QCT and DXA between the groups at 24 months were 43.1% and 11.9%, respectively (p < 0.001). The mean percent differences over the estrogen-only group in hip BMD were 3.4% for total hip (p < 0.01) and 2.6% for femoral neck at 24 months. Biochemical markers of bone turnover increased to more than 150% during the first 6 months of therapy, remained elevated throughout the 12-month treatment period, and returned to baseline values within 6 months of discontinuing the PTH treatment. These results suggest that PTH dramatically increases bone mass in the lumbar spine and hip in postmenopausal women with glucocorticoid-induced osteoporosis who are taking hormone replacement therapy. However, the maximum effect of this anabolic agent on bone mass at the hip after 12 months of treatment requires at least 6-12 months after the PTH treatment is discontinued.


Assuntos
Densidade Óssea/efeitos dos fármacos , Osteoporose/tratamento farmacológico , Hormônio Paratireóideo/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Prednisona/efeitos adversos , Absorciometria de Fóton , Idoso , Idoso de 80 Anos ou mais , Cálcio/metabolismo , Feminino , Humanos , Pessoa de Meia-Idade , Osteoporose/induzido quimicamente
5.
J Chromatogr A ; 855(2): 593-600, 1999 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-10519096

RESUMO

The performance of a new kind of multi-sorbent trap for use in the simultaneous determination of compounds of different volatility and polarity was investigated. The adsorbents employed for this purpose were Carbograph 2 and Carbograph 5. The performance of this trap was evaluated in terms of thermal desorption and solvent extraction recoveries of substances belonging to the main classes of organic compounds, at different amounts and volumes of air sampled corresponding to concentrations ranging from 0.1 to 1000 mg/m3. The tubes examined allowed the trapping of the compounds used and their complete desorption with the procedure best suited to the analytical problem.


Assuntos
Ar/análise , Compostos Orgânicos/análise , Estudos de Avaliação como Assunto
6.
Anal Chem ; 79(14): 5364-72, 2007 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17569502

RESUMO

Major progress in interfacing liquid chromatography and electron ionization mass spectrometry is presented. The minimalism of the first prototype, called the Direct-EI interface, has been widely refined, improved, and applied to modern instrumentation. The simple interfacing principle is based on the straight connection between a nanoHPLC system and a mass spectrometer equipped with an EI source forming a solid and reliable unicum resembling the immediacy and straightforwardness of GC/MS. The interface shows a superior performance in the analysis of small-medium molecular weight compounds, especially when compared to its predecessors, and a unique trait that excels particularly in the following aspects: (1) It delivers high-quality, fully library matchable mass spectra of most sub-1 kDa molecules amenable by HPLC. (2) It is a chemical ionization free interface (unless operated intentionally) with accurate reproduction of the expected isotope ion abundances. (3) Response is never influenced by matrix components in the sample or in the mobile phase (nonvolatile salts are also well accepted). A deep evaluation of these aspects is presented and discussed in detail. Other characteristics of the interface performance such as limits of detections, range of linear response, and intra- and interday signal stability were also considered. The usefulness of the interface has been tested in a few real-world applications where matrix components played a detrimental role with other LC/MS techniques.

7.
Water Res ; 41(13): 2911-20, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17521695

RESUMO

The massive accumulation of organic matter, which periodically occurs in the northern Adriatic Sea, and in other locations worldwide, is presently thought to be the results of the aggregation of dissolved organic matter (DOM) into particulate organic matter (POM). This phenomenon is the result of human activities and propitious weather conditions. Although many aspects of the phenomenon are well understood, the trigger mechanisms leading to mucilage formation have not been clarified yet, probably as a consequence of inadequate analytical approaches. In this context, the recent advancements in LC-MS interfacing might contribute in clarifying the mechanism of mucilage formation. In the present paper, hydrophilic interaction liquid chromatography coupled with electrospray tandem mass spectrometry (HILC-ESI-MS/MS) is proposed as an innovative method for the investigation of underivatized oligosaccharides in mucilage samples. Recent findings suggest that the significant presence of these compounds in seawater can play an important role in the initial steps of the agglomeration processes forming gelatinous material. Our results reveal the presence of several maltodextrines in the water-soluble fraction of mucilage macroaggregates, collected in various locations of the northern Adriatic Sea. In our knowledge, the proposed method is the first application of LC-MS in the investigation of marine mucilage.


Assuntos
Adesivos/química , Oligossacarídeos/química , Água do Mar/química , Espectrometria de Massas por Ionização por Electrospray , Cromatografia Líquida , Oceanos e Mares , Poluição da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA