Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Liver Int ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38591767

RESUMO

BACKGROUND: The optimal cardiovascular assessment of liver transplant (LT) candidates is unclear. We aimed to evaluate the performance of CT-based coronary tests (coronary artery calcium score [CACS] and coronary CT angiography [CCTA]) and a modification of the CAD-LT score (mCAD-LT, excluding family history of CAD) to diagnose significant coronary artery disease (CAD) before LT and predict the incidence of post-LT cardiovascular events (CVE). METHODS: We retrospectively analysed a single-centre cohort of LT candidates who underwent non-invasive tests; invasive coronary angiography (ICA) was performed depending on the results of non-invasive tests. mCAD-LT was calculated in all patients. RESULTS: Six-hundred-and-thirty-four LT candidates were assessed and 351 of them underwent LT. CACS, CCTA and ICA were performed in 245, 123 and 120 LT candidates, respectively. Significant CAD was found in 30% of patients undergoing ICA. The AUROCs of mCAD-LT (.722) and CCTA (.654) were significantly higher than that of CACS (.502) to predict the presence of significant CAD. Specificity of the tests ranged between 31% for CCTA and 53% for CACS. Among patients who underwent LT, CACS ≥ 400 and mCAD-LT were independently associated with the incidence of CVE; in patients who underwent CCTA before LT, significant CAD at CCTA also predicted post-LT CVE. CONCLUSION: In this cohort, mCAD-LT score and CT-based tests detect the presence of significant CAD in LT candidates, although they tend to overestimate it. Both mCAD-LT score and CT-based tests classify LT recipients according to their risk of post-LT CVE and can be used to improve post-LT risk mitigation.

2.
Medicina (Kaunas) ; 60(1)2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38256411

RESUMO

Background and Objectives: Left atrial (LA) remodelling and dilatation predicts atrial fibrillation (AF) recurrences after catheter ablation. However, whether right atrial (RA) remodelling and dilatation predicts AF recurrences after ablation has not been fully evaluated. Materials and Methods: This is an observational study of 85 consecutive patients (aged 57 ± 9 years; 70 [82%] men) who underwent cardiac magnetic resonance before first catheter ablation for AF (40 [47.1%] persistent AF). Four-chamber cine-sequence was selected to measure LA and RA area, and ventricular end-systolic image phase to obtain atrial 3D volumes. The effect of different variables on event-free survival was investigated using the Cox proportional hazards model. Results: In patients with persistent AF, combined LA and RA area indexed to body surface area (AILA + RA) predicted AF recurrences (HR = 1.08, 95% CI 1.00-1.17, p = 0.048). An AILA + RA cut-off value of 26.7 cm2/m2 had 72% sensitivity and 73% specificity for predicting recurrences in patients with persistent AF. In this group, 65% of patients with AILA + RA > 26.7 cm2/m2 experienced AF recurrence within 2 years of follow-up (median follow-up 11 months), compared to 25% of patients with AILA + RA ≤ 26.7 cm2/m2 (HR 4.28, 95% CI 1.50-12.22; p = 0.007). Indices of LA and RA dilatation did not predict AF recurrences in patients with paroxysmal AF. Atrial 3D volumes did not predict AF recurrences after ablation. Conclusions: In this pilot study, the simple measurement of AILA + RA may predict recurrences after ablation of persistent AF, and may outperform measurements of atrial volumes. In paroxysmal AF, atrial dilatation did not predict recurrences. Further studies on the role of RA and LA remodelling are needed.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Projetos Piloto , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração
3.
Eur J Appl Physiol ; 122(12): 2585-2596, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36088588

RESUMO

PURPOSE: Athlete's heart encompasses multiple physiological cardiac adaptations, although less is known at atrial level. How sex may influence the type and extent of atrial adaptations to exercise stimuli is also unknown. Our objective was to compare gender differences of echocardiographic atrial function indices in response to exercise in endurance athletes (EAs). METHODS: Highly trained (> 10 h/week) endurance athletes performed a maximal cardiopulmonary exercise test (CPET). Echocardiographic evaluation was performed at rest and immediately after exercise. Atria analysis consisted of standard and speckle-tracking echocardiographic assessment of atrial dimensions and contractile, reservoir, and conduit functions with myocardial deformation. RESULTS: 80 EAs (55% women) were enrolled and performed excellent CPET (129.6% of predicted VO2 maximal consumption). At rest, left atrial (LA) volumes and strain were similar between men and women. Women had lower right atrial (RA) volumes (26.7 vs 32.9 ml/m2, p < 0.001) and higher reservoir and conduit strain absolute values. After exercise, women exhibited a larger improvement in reservoir and conduit LA strain, and the same trend was observed for the RA. In EAs with LA dilatation on baseline (~ 50%), women persistently showed higher increase in reservoir and conduit strain profile with exercise compared to men. CONCLUSION: In highly trained EAs, women have similar or even lower atrial dimensions remodelling compared to men, but better function based on reservoir and conduit strain values both at rest and in response to exercise. This phenomenon should be confirmed in larger studies and its potential role in the development of supraventricular arrhythmias, addressed in a specifically designed protocol.


Assuntos
Função Atrial , Átrios do Coração , Masculino , Humanos , Feminino , Átrios do Coração/diagnóstico por imagem , Função Atrial/fisiologia , Ecocardiografia , Exercício Físico , Atletas
4.
J Cardiovasc Electrophysiol ; 31(3): 638-646, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31957087

RESUMO

INTRODUCTION: Ablation with second-generation cryoballoon technology evolves as an effective and safe alternative to radiofrequency for atrial fibrillation ablation procedures. Nevertheless, the optimal freezing strategy remains unknown. Our objective was to identify the procedural cryoablation parameters predicting successful peri-pulmonary vein (PV) lesions by directly analyzing Postablation gaps in late-gadolinium-enhanced cardiac magnetic resonance (LGE-CMR). METHODS AND RESULTS: Forty-nine consecutive patients (196 PVs) undergoing ablation with second-generation cryoballoon at our center were included. The number and duration of cryoballoon application to achieve PV isolation were left to operator discretion. Gap number and length were quantified in all patients with a LGE-CMR performed 3 months postablation. Application time (420 ± 217 seconds), number of applications (2.1 ± 1.2), application time after electrical isolation (311 ± 194 seconds) and minimum temperature (-45.8 ± 6.5°C) were similar in the 4 PVs. Gaps were observed in 148 PVs (76%), averaging 1.3 ± 1 gaps per vein. Gaps were longer and more frequent in the right PVs (91% vs 59% in left PVs, P < .001). Neither the number, total duration of applications, nor postisolation application time predicted relative length or number of gaps. CONCLUSIONS: After successful PV isolation was achieved in patients undergoing cryoablation, increasing the number of applications, the total application time or application time postisolation did not result in a reduction in the number or the relative length of gaps.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Potenciais de Ação , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Meios de Contraste/administração & dosagem , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 22(4): 598-606, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32101605

RESUMO

AIMS: Ventricular tachycardia (VT) substrate-based ablation has become a standard procedure. Electroanatomical mapping (EAM) detects scar tissue heterogeneity and define conduction channels (CCs) that are the ablation target. Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) is able to depict CCs and increase ablation success. Most patients undergoing VT ablation have an implantable cardioverter-defibrillator (ICD) that can cause image artefacts in LGE-CMR. Recently wideband (WB) LGE-CMR sequence has demonstrated to decrease these artefacts. The aim of this study is to analyse accuracy of WB-LGE-CMR in identifying the CC entrances. METHODS AND RESULTS: Thirteen consecutive ICD-patients who underwent VT ablation after WB-LGE-CMR were included. Number and location of CC entrances in three-dimensional EAM and in WB-LGE-CMR reconstruction were compared. Concordance was compared with a historical cohort matched by cardiomyopathy, scar location, and age (26 patients) with LGE-CMR prior to ICD and VT ablation. In WB-CMR group, 101 and 93 CC entrances were identified in EAM and WB-LGE-CMR, respectively. In historical cohort, 179 CC entrances were identified in both EAM and LGE-CMR. The EAM/CMR concordance was 85.1% and 92.2% in the WB and historical group, respectively (P = 0.66). There were no differences in false-positive rate (CC entrances detected in CMR and absent in EAM: 7.5% vs 7.8% in WB vs. conventional CMR, P = 0.92) nor in false-negative rate (CC entrances present in EAM not detected in CMR: 14.9% vs.7.8% in WB vs. conventional CMR, P = 0.23). Epicardial CCs was predictor of poor CMR/EAM concordance (OR 2.15, P = 0.031). CONCLUSION: Use of WB-LGE-CMR sequence in ICD-patients allows adequate VT substrate characterization to guide VT ablation with similar accuracy than conventional LGE-CMR in patients without an ICD.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Miocárdio/patologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
6.
J Cardiovasc Electrophysiol ; 29(8): 1065-1072, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29722466

RESUMO

INTRODUCTION: The purpose of this study was to compare the anatomical characteristics of scar formation achieved by visual-guided laser balloon (Laser) and radiofrequency (RF) pulmonary vein isolation (PVI), using late-gadolinium-enhanced cardiac magnetic resonance imaging (LGE-CMR). METHODS AND RESULTS: We included 17 patients with paroxysmal or early persistent drug resistant AF who underwent Laser ablation; 2 were excluded due to procedure-related complications. The sample was matched with a historical group of 15 patients who underwent PVI using RF. LGE-CMR sequences were acquired before and 3 months post-PVI. Ablation gaps were defined as pulmonary vein (PV) perimeter sections showing no gadolinium enhancement. The number of ablation gaps was lower in Laser versus RF ablations (median 7 vs. 14, P  =  0.015). Complete anatomical PVI (circumferential scar around PV, without gaps) was more frequently achieved with Laser than with RF (39% vs. 19% of PVs, P  =  0.025). Fewer gaps were present at the superior and anterior left PV and posterior right PV antral regions in the Laser group, compared to RF. Scar extension into the PVs was similar in both groups, although RF produced more extensive ablation scar toward the LA body. AF recurrences at 1 year were similar in both groups (Laser 36% vs. RF 27%, P  =  1.00). CONCLUSIONS: Compared to RF, Laser ablation achieved more complete anatomical PVI, with less LA scar extension. However, AF recurrence appears to be similar after Laser compared to RF ablation. Further studies are needed to assess whether the anatomical advantages of Laser ablation translate into clinical benefit in patients with AF.


Assuntos
Gadolínio , Imagem Cinética por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ablação por Radiofrequência/tendências , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Coortes , Feminino , Seguimentos , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/tendências , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos
7.
Europace ; 20(12): 1959-1965, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29860416

RESUMO

Aims: Left atrial (LA) fibrosis can be identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) in patients with atrial fibrillation (AF). However, there is limited information about anatomical fibrosis distribution in the left atrium. The aim is to determine whether there is a preferential spatial distribution of fibrosis in the left atrium in patients with AF. Methods and results: A 3-Tesla LGE-CMR was performed in 113 consecutive patients referred for AF ablation. Images were post-processed and analysed using ADAS-AF software (Galgo Medical), which allows fibrosis identification in 3D colour-coded shells. A regional semiautomatic LA parcellation software was used to divide the atrial wall into 12 segments: 1-4, posterior wall; 5-6, floor; 7, septal wall; 8-11, anterior wall; 12, lateral wall. The presence and amount of fibrosis in each segment was obtained for analysis. After exclusions for artefacts and insufficient image quality, 76 LGE-MRI images (68%) were suitable for fibrosis analysis. Segments 3 and 5, closest to the left inferior pulmonary vein, had significantly higher fibrosis (40.42% ± 23.96 and 25.82% ± 21.24, respectively; P < 0.001), compared with other segments. Segments 8 and 10 in the anterior wall contained the lowest fibrosis (2.54% ± 5.78 and 3.82% ± 11.59, respectively; P < 0.001). Age >60 years was significantly associated with increased LA fibrosis [95% confidence interval (CI) 0.19-8.39, P = 0.04] and persistent AF approached significance (95% CI -0.19% to 7.83%, P = 0.08). Conclusion: In patients with AF, the fibrotic area is preferentially located at the posterior wall and floor around the antrum of the left inferior pulmonary vein. Age >60 years was associated with increased fibrosis.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo , Remodelamento Atrial , Meios de Contraste/administração & dosagem , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/diagnóstico por imagem , Fatores Etários , Idoso , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Feminino , Fibrose , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Fatores de Risco
8.
J Cardiovasc Electrophysiol ; 27(7): 804-10, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27027899

RESUMO

BACKGROUND: Left atrial (LA) sphericity (LASP) is a new remodeling parameter based on LA shape analysis, with independent predictive value for recurrence after atrial fibrillation (AF) ablation. OBJECTIVES: To evaluate the association between LASP and thromboembolic events (TE) in patients with AF. METHODS: Twenty-nine AF patients and prior TE and 29 age- and gender-matched controls were included. LASP was calculated using a 3D-LA reconstruction. The LA appendage (LAA) volume and morphology were assessed. ROC curve analysis was performed for LASP, LA volume, LAA volume, and CHAD/CHA2 D-VASc scores (Stroke2 -the grouping variable-was excluded). RESULTS: Mean age of the study population was 61 ± 11 years (79.3% males, 53.4% hypertension, 8.6% diabetes). Patients with prior TE had higher LASP than those without (82.5 ± 3.3% vs. 80.2 ± 3.1%, P = 0.008); there were no differences in CHAD or CHA2 D-VASc scores, LA volume, LAA volume, or LAA morphology. The C-statistic was higher for LASP (0.71) than for other tested variables (CHAD score = 0.58, CHA2 D-VASc score = 0.59, LA volume = 0.50, LAA volume = 0.46; P < 0.01 for all vs. LASP). The best cutoff value for LASP was 83.6% (sensitivity 0.52, specificity 0.90). Logistic regression analysis showed predictive value for LASP (OR 1.26 per each 1% increase [1.85-52.20], P = 0.013), but not for clinical risk scores. The addition of LASP to the CHAD and CHA2 D-VASc scores increased the predictive value over the risk scores alone (P = 0.004), and reclassified 45.5% of patients with CHAD = 0 (no anticoagulation indicated) to moderate-risk (anticoagulation indicated). CONCLUSION: LA sphericity is associated with prior TE in AF patients and improves the performance of the CHAD and CHA2 D-VASc scores alone.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Função do Átrio Esquerdo , Remodelamento Atrial , Coagulação Sanguínea , Angiografia Coronária/métodos , Angiografia por Ressonância Magnética , Acidente Vascular Cerebral/etiologia , Tromboembolia/etiologia , Idoso , Área Sob a Curva , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Espanha , Acidente Vascular Cerebral/diagnóstico , Tromboembolia/sangue , Tromboembolia/diagnóstico , Utah
9.
J Cardiovasc Magn Reson ; 18(1): 78, 2016 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-27814739

RESUMO

BACKGROUND: Chronic total occlusion percutaneous coronary intervention (CTO-PCI) can improve angina and left ventricular ejection fraction (LVEF). These benefits were not assessed in populations with heart failure with reduced ejection fraction (HFrEF). We studied the effect of CTO-PCI on left ventricular function and clinical parameters in patients with HFrEF. METHODS: Using cardiovascular magnetic resonance (CMR), we studied 29 patients with HFrEF and evidence of viability and/or ischemia in the territory supplied by a CTO who were successfully treated with CTO-PCI. In patients with multi-vessel disease, non-CTO PCI was also performed. Imaging parameters, clinical status, and brain natriuretic peptide (BNP) levels were evaluated before and 6 months after CTO-PCI. RESULTS: A decrease in left ventricular end-systolic volume (160 ± 54 ml vs. 143 ± 58 ml; p = 0.029) and an increase in LVEF (31.3 ± 7.4 % vs. 37.7 ± 8 %; p < 0.001) were observed. There were no differences in LVEF improvement between patients who underwent non-CTO PCI (n = 11) and those without this intervention (n = 18); (p = 0.73). The number of segments showing perfusion defects was significantly reduced (0.5 ± 1 vs. 0.2 ± 0.5; p = 0.043). Angina (p = 0.002) and NYHA functional class (p = 0.004) improved, and BNP levels decreased (p = 0.004) after CTO-PCI. CONCLUSIONS: In this group of patients with HFrEF showing CMR evidence of viability and/or ischemia within the territory supplied by the CTO, an improvement in ejection fraction, left ventricular end-systolic volume and ischemia burden was observed after CTO-PCI. Clinical and laboratory parameters also improved. TRIAL REGISTRATION: ClinicalTrials.gov NCT02570087 . Registered 6 October 2015.


Assuntos
Oclusão Coronária/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Intervenção Coronária Percutânea , Volume Sistólico , Função Ventricular Esquerda , Idoso , Biomarcadores/sangue , Doença Crônica , Meios de Contraste/administração & dosagem , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/patologia , Oclusão Coronária/fisiopatologia , Feminino , Nível de Saúde , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Peptídeo Natriurético Encefálico/sangue , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Sobrevivência de Tecidos , Resultado do Tratamento
10.
J Heart Valve Dis ; 25(1): 1-7, 2016 01.
Artigo em Inglês | MEDLINE | ID: mdl-29505225

RESUMO

BACKGROUND AIM OF THE STUDY: The real burden of valvular heart disease (VHD) is scarcely known, as several factors may potentially lead to its increased prevalence. The study aim was to assess the prevalence of VHD and its treatment in the authors' environment to plan the healthcare requisites for optimal management of the condition. METHODS: A retrospective analysis was conducted of data acquired from patients who had been assessed at different consultation levels for cardiovascular disorders during a six-month period between January and June 2014 in public health referral area of 500,00 inhabitants. Patients included were those admitted to hospital cardiology, cardiac surgery and geriatric care units (n = 1,083), as well as ambulatory patients attending cardiology-specific outpatient clinics at the authors' hospital or at two ascribed primary care centers (n = 852). Data were registered regarding the epidemiology, etiology, echocardiography and treatment of patients in whom VHD was detected. RESULTS: Among a total of 1,935 adult patients, moderate or severe valve disease was identified in 453 cases (23.4%) who were evaluated for cardiovascular disease. The prevalence of VHD increased with age. Multivalvular moderate-severe dysfunction was present in two valves in 33% and in three valves in 5.7% of patients. Significant mitral valve disease was present in 39% and aortic valve disease in 48% of patients. The etiology of the valvular lesions was degenerative in 60%, functional in 15.5%, rheumatic in almost 10%, congenital in 6%, due to endocarditis in only 3%. Patients with VHD represented up to 24.2% of the in-hospital admissions. An interventional treatment was required in 55% of the patients (mostly surgical valve procedures). CONCLUSION: The present study results showed that VHD is a frequent occurrence and is increasingly prevalent with age, constituting up to one-fourth of all in-hospital admissions for cardiovascular disease. VHD is a growing public health problem that should be addressed with appropriate resources to improve research into its nature, diagnosis and treatment.


Assuntos
Serviço Hospitalar de Cardiologia/estatística & dados numéricos , Geriatria/estatística & dados numéricos , Doenças das Valvas Cardíacas/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/epidemiologia , Estenose da Valva Mitral/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia
11.
Europace ; 17(6): 938-45, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25616406

RESUMO

AIMS: Non-invasive depiction of conducting channels (CCs) is gaining interest for its usefulness in ventricular tachycardia (VT) ablation. The best imaging approach has not been determined. We compared characterization of myocardial scar with late-gadolinium enhancement cardiac magnetic resonance using a navigator-gated 3D sequence (3D-GRE) and conventional 2D imaging using either a single shot inversion recovery steady-state-free-precession (2D-SSFP) or inversion-recovery gradient echo (2D-GRE) sequence. METHODS AND RESULTS: We included 30 consecutive patients with structural heart disease referred for VT ablation. Preprocedural myocardial characterization was conducted in a 3 T-scanner using 2D-GRE, 2D-SSFP and 3D-GRE sequences, yielding a spatial resolution of 1.4 × 1.4 × 5 mm, 2 × 2 × 5 mm, and 1.4 × 1.4 × 1.4 mm, respectively. The core and border zone (BZ) scar components were quantified using the 60% and 40% threshold of maximum pixel intensity, respectively. A 3D scar reconstruction was obtained for each sequence. An electrophysiologist identified potential CC and compared them with results obtained with the electroanatomic map (EAM). We found no significant differences in the scar core mass between the 2D-GRE, 2D-SSFP, and 3D-GRE sequences (mean 7.48 ± 6.68 vs. 8.26 ± 5.69 and 6.26 ± 4.37 g, respectively, P = 0.084). However, the BZ mass was smaller in the 2D-GRE and 2D-SSFP than in the 3D-GRE sequence (9.22 ± 5.97 and 9.39 ± 6.33 vs. 10.92 ± 5.98 g, respectively; P = 0.042). The matching between the CC observed in the EAM and in 3D-GRE was 79.2%; when comparing the EAM and the 2D-GRE and the 2D-SSFP sequence, the matching decreased to 61.8% and 37.7%, respectively. CONCLUSION: 3D scar reconstruction using images from 3D-GRE sequence improves the overall delineation of CC prior to VT ablation.


Assuntos
Cardiomiopatias/patologia , Cicatriz/patologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Miocárdio/patologia , Taquicardia Ventricular/cirurgia , Idoso , Cardiomiopatias/complicações , Ablação por Cateter/métodos , Cicatriz/etiologia , Estudos de Coortes , Meios de Contraste , Feminino , Fibrose , Gadolínio DTPA , Humanos , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Isquemia Miocárdica/complicações , Isquemia Miocárdica/patologia , Cirurgia Assistida por Computador , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/patologia
12.
Eur Heart J ; 35(20): 1316-26, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24394378

RESUMO

AIMS: The endocardial vs. epicardial origin of ventricular arrhythmia (VA) can be inferred from detailed electrocardiogram (ECG) analysis. However, despite its clinical usefulness, ECG has limitations. Alternatively, scarred tissue sustaining VAs can be identified by contrast-enhanced cardiac magnetic resonance (ce-CMR). The objective of this study was to determine the clinical value of analysing the presence and distribution pattern of scarred tissue in the ventricles to identify the VA site of origin and the ablation approach required. METHODS AND RESULTS: A ce-CMR study was carried out before the index ablation procedure in a cohort of 80 patients with non-idiopathic VA. Hyper-enhancement (HE) in each ventricular segment was coded as absent, subendocardial, transmural, mid-myocardial, or epicardial. The endocardial or epicardial VA site of origin was also assigned according to the approach needed for ablation. The clinical VA was successfully ablated in 77 (96.3%) patients, all of them showing HE on ce-CMR. In segments with successful ablation of the clinical ventricular tachycardia, HE was absent in 3 (3.9%) patients, subendocardial in 19 (24.7%), transmural in 36 (46.7%), mid-myocardial in 8 (10.4%), and subepicardial in 11 (14.3%) patients. Epicardial ablation of the index VA was necessary in 3 (6.1%) ischaemic and 12 (42.9%) non-ischaemic patients. The presence of subepicardial HE in the successful ablation segment had 84.6% sensitivity and 100% specificity in predicting an epicardial origin of the VA. CONCLUSION: Contrast-enhanced cardiac magnetic resonance is helpful to localize the target ablation substrate of non-idiopathic VA and also to plan the approach needed, especially in non-ischaemic patients.


Assuntos
Arritmias Cardíacas/diagnóstico , Ablação por Cateter/métodos , Arritmias Cardíacas/cirurgia , Meios de Contraste , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
13.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37819047

RESUMO

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Miocárdio/patologia , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Cicatriz/patologia , Estudos Prospectivos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/patologia , Espectroscopia de Ressonância Magnética
14.
Heart Rhythm ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636930

RESUMO

BACKGROUND: Atrial arrhythmogenic substrate is a key determinant of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI), and reduced conduction velocities have been linked to adverse outcome. However, a noninvasive method to assess such electrophysiologic substrate is not available to date. OBJECTIVE: This study aimed to noninvasively assess regional conduction velocities and their association with arrhythmia-free survival after PVI. METHODS: A consecutive 52 patients scheduled for AF ablation (PVI only) and 19 healthy controls were prospectively included and received electrocardiographic imaging (ECGi) to noninvasively determine regional atrial conduction velocities in sinus rhythm. A novel ECGi technology obviating the need of additional computed tomography or cardiac magnetic resonance imaging was applied and validated by invasive mapping. RESULTS: Mean ECGi-determined atrial conduction velocities were significantly lower in AF patients than in healthy controls (1.45 ± 0.15 m/s vs 1.64 ± 0.15 m/s; P < .0001). Differences were particularly pronounced in a regional analysis considering only the segment with the lowest average conduction velocity in each patient (0.8 ± 0.22 m/s vs 1.08 ± 0.26 m/s; P < .0001). This average conduction velocity of the "slowest" segment was independently associated with arrhythmia recurrence and better discriminated between PVI responders and nonresponders than previously proposed predictors, including left atrial size and late gadolinium enhancement (magnetic resonance imaging). Patients without slow-conduction areas (mean conduction velocity <0.78 m/s) showed significantly higher 12-month arrhythmia-free survival than those with 1 or more slow-conduction areas (88.9% vs 48.0%; P = .002). CONCLUSION: This is the first study to investigate regional atrial conduction velocities noninvasively. The absence of ECGi-determined slow-conduction areas well discriminates PVI responders from nonresponders. Such noninvasive assessment of electrical arrhythmogenic substrate may guide treatment strategies and be a step toward personalized AF therapy.

15.
Eur Heart J Cardiovasc Imaging ; 24(7): 930-937, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-36644919

RESUMO

AIMS: Being born small for gestational age (SGA, 10% of all births) is associated with increased risk of cardiovascular mortality in adulthood together with lower exercise tolerance, but mechanistic pathways are unclear. Central obesity is known to worsen cardiovascular outcomes, but it is uncertain how it affects the heart in adults born SGA. We aimed to assess whether central obesity makes young adults born SGA more susceptible to cardiac remodelling and dysfunction. METHODS AND RESULTS: A perinatal cohort from a tertiary university hospital in Spain of young adults (30-40 years) randomly selected, 80 born SGA (birth weight below 10th centile) and 75 with normal birth weight (controls) was recruited. We studied the associations between SGA and central obesity (measured via the hip-to-waist ratio and used as a continuous variable) and cardiac regional structure and function, assessed by cardiac magnetic resonance using statistical shape analysis. Both SGA and waist-to-hip were highly associated to cardiac shape (F = 3.94, P < 0.001; F = 5.18, P < 0.001 respectively) with a statistically significant interaction (F = 2.29, P = 0.02). While controls tend to increase left ventricular end-diastolic volumes, mass and stroke volume with increasing waist-to-hip ratio, young adults born SGA showed a unique response with inability to increase cardiac dimensions or mass resulting in reduced stroke volume and exercise capacity. CONCLUSION: SGA young adults show a unique cardiac adaptation to central obesity. These results support considering SGA as a risk factor that may benefit from preventive strategies to reduce cardiometabolic risk.


Assuntos
Obesidade Abdominal , Remodelação Ventricular , Recém-Nascido , Gravidez , Feminino , Humanos , Adulto Jovem , Peso ao Nascer , Obesidade Abdominal/diagnóstico por imagem , Obesidade Abdominal/epidemiologia , Idade Gestacional , Recém-Nascido Pequeno para a Idade Gestacional , Obesidade
16.
Rev Esp Cardiol (Engl Ed) ; 76(3): 173-182, 2023 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35809892

RESUMO

INTRODUCTION AND OBJECTIVES: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. METHODS: A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. RESULTS: The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. CONCLUSIONS: An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Cicatriz/patologia , Cicatriz/cirurgia , Meios de Contraste , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/cirurgia , Fibrose , Ablação por Cateter/métodos , Gadolínio , Espectroscopia de Ressonância Magnética
17.
Rev Esp Cardiol (Engl Ed) ; 76(3): 183-196, 2023 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36539182

RESUMO

Magnetic resonance has become a first-line imaging modality in various clinical scenarios. The number of patients with different cardiovascular devices, including cardiac implantable electronic devices, has increased exponentially. Although there have been reports of risks associated with exposure to magnetic resonance in these patients, the clinical evidence now supports the safety of performing these studies under specific conditions and following recommendations to minimize possible risks. This document was written by the Working Group on Cardiac Magnetic Resonance Imaging and Cardiac Computed Tomography of the Spanish Society of Cardiology (SEC-GT CRMTC), the Heart Rhythm Association of the Spanish Society of Cardiology (SEC-Heart Rhythm Association), the Spanish Society of Medical Radiology (SERAM), and the Spanish Society of Cardiothoracic Imaging (SEICAT). The document reviews the clinical evidence available in this field and establishes a series of recommendations so that patients with cardiovascular devices can safely access this diagnostic tool.


Assuntos
Cardiologia , Desfibriladores Implantáveis , Cardiopatias , Humanos , Consenso , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
18.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36654964

RESUMO

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

19.
J Am Heart Assoc ; 11(20): e026028, 2022 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-36216438

RESUMO

Background Left atrial structural remodeling contributes to the arrhythmogenic substrate of atrial fibrillation (AF), but the role of the right atrium (RA) remains unknown. Our aims were to comprehensively characterize right atrial structural remodeling in AF and identify right atrial parameters predicting recurrences after ablation. Methods and Results A 3.0 T late gadolinium enhanced-cardiac magnetic resonance was obtained in 109 individuals (9 healthy volunteers, 100 patients with AF undergoing ablation). Right and left atrial volume, surface, and sphericity were quantified. Right atrial global and regional fibrosis burden was assessed with validated thresholds. Patients with AF were systematically followed after ablation for recurrences. Progressive right atrial dilation and an increase in sphericity were observed from healthy volunteers to patients with paroxysmal and persistent AF; fibrosis was similar among the groups. The correlation between parameters recapitulating right atrial remodeling was mild. Subsequently, remodeling in both atria was compared. The RA was larger than the left atrium (LA) in all groups. Fibrosis burden was higher in the LA than in the RA of patients with AF, whereas sphericity was higher in the LA of patients with persistent AF only. Fibrosis, volume, and surface of the RA and LA, but not sphericity, were strongly correlated. Tricuspid regurgitation predicted right atrial volume and shape, whereas diabetes was associated with right atrial fibrosis burden; sex and persistent AF also predicted right atrial volume. Fibrosis in the RA was mostly located in the inferior vena cava-RA junction. Only right atrial sphericity is significantly associated with AF recurrences after ablation (hazard ratio, 1.12 [95% CI, 1.01-1.25]). Conclusions AF progression associates with right atrial remodeling in parallel with the LA. Right atrial sphericity yields prognostic significance after ablation.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Ablação por Cateter/métodos , Gadolínio , Átrios do Coração , Fibrose , Espectroscopia de Ressonância Magnética
20.
Front Cardiovasc Med ; 8: 719113, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34490379

RESUMO

Background: The cardiac response to endurance exercise has been studied previously, and recent reports have described the extension of this remodeling to the pulmonary vasculature. However, these reports have focused primarily on land-based sports and few data are available on exercise-induced cardio-pulmonary adaptation in swimming. Nor has the impact of sex on this exercise-induced cardio-pulmonary remodeling been studied in depth. The main aim of our study was to evaluate cardiac and pulmonary circulation remodeling in endurance swimmers. Among the secondary objectives, we evaluate the impact of sex and endurance sport discipline on this cardio-pulmonary remodeling promoted by exercise training. Methods:Resting cardiovascular magnetic resonance imaging was performed in 30 healthy well-trained endurance swimmers (83.3% male) and in 19 terrestrial endurance athletes (79% male) to assess biventricular dimensions and function. Pulmonary artery dimensions and flow as well as estimates of pulmonary vascular resistance (PVR) were also evaluated. Results:In relation to the reference parameters for the non-athletic population, male endurance swimmers had larger biventricular and pulmonary artery size (7.4 ± 1.0 vs. 5.9 ± 1.1 cm2, p < 0.001) with lower biventricular ejection fraction (EF) (left ventricular (LV) EF: 58 ± 4.4 vs. 67 ± 4.5 %, p < 0.001; right ventricular (RV) EF: 60 ± 4 vs. 66 ± 6 %, p < 0.001), LV end-diastolic volume (EDV): 106 ± 11 vs. 80 ± 9 ml/m2, p < 0.001; RV EDV: 101 ± 14 vs. 83 ± 12 ml/m2, p < 0.001). Significantly larger LV volume and lower LV EF were also observed in female swimmers (LV EF: 60 ± 5.3 vs. 67 ± 4.6 %, p = 0.003; LV EDV: 90 ± 17.6 vs. 75± 8.7 ml/m2, p = 0.002). Compared to terrestrial endurance athletes, swimmers showed increased LV indexed mass (75.0 ± 12.8 vs. 61.5 ± 10.0 g/m2, p < 0.001). The two groups of endurance athletes had similar pulmonary artery remodeling. Conclusions: Cardiac response to endurance swimming training implies an adaptation of both ventricular and pulmonary vasculature, as in the case of terrestrial endurance athletes. Cardio-pulmonary remodeling seems to be less extensive in female than in male swimmers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA