Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Circulation ; 149(9): 644-655, 2024 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-37883682

RESUMO

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/etiologia
2.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
3.
Circulation ; 131(18): 1566-74, 2015 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-25753535

RESUMO

BACKGROUND: We aimed to determine the incidence, predictors, clinical characteristics, management, and outcomes of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: This multicenter registry included 53 patients (mean age, 79±8 years; men, 57%) who suffered IE after TAVI of 7944 patients after a mean follow-up of 1.1±1.2 years (incidence, 0.67%, 0.50% within the first year after TAVI). Mean time from TAVI was 6 months (interquartile range, 1-14 months). Orotracheal intubation (hazard ratio, 3.87; 95% confidence interval, 1.55-9.64; P=0.004) and the self-expandable CoreValve system (hazard ratio, 3.12; 95% confidence interval, 1.37-7.14; P=0.007) were associated with IE (multivariate analysis including 3067 patients with individual data). The most frequent causal microorganisms were coagulase-negative staphylococci (24%), followed by Staphylococcus aureus (21%) and enterococci (21%). Vegetations were present in 77% of patients (transcatheter valve leaflets, 39%; stent frame, 17%; mitral valve, 21%). At least 1 complication of IE occurred in 87% of patients (heart failure in 68%). However, only 11% of patients underwent valve intervention (valve explantation and valve-in-valve procedure in 4 and 2 patients, respectively). The mortality rate in hospital was 47.2% and increased to 66% at the 1-year follow-up. IE complications such as heart failure (P=0.037) and septic shock (P=0.002) were associated with increased in-hospital mortality. CONCLUSIONS: The incidence of IE at 1 year after TAVI was 0.50%, and the risk increased with the use of orotracheal intubation and a self-expandable valve system. Staphylococci and enterococci were the most common agents. Although most patients presented at least 1 complication of IE, valve intervention was performed in a minority of patients, and nearly half of the patients died during the hospitalization period.


Assuntos
Endocardite Bacteriana/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Infecções Relacionadas à Prótese/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Enterococcus , Contaminação de Equipamentos , Feminino , Infecções por Bactérias Gram-Positivas/etiologia , Infecções por Bactérias Gram-Positivas/cirurgia , Insuficiência Cardíaca/etiologia , Mortalidade Hospitalar , Humanos , Incidência , Intubação Intratraqueal/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Sistema de Registros , Estudos Retrospectivos , Risco , Infecções Estafilocócicas/etiologia , Infecções Estafilocócicas/cirurgia , Resultado do Tratamento
4.
Circulation ; 142(15): 1497-1499, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33044863
5.
Int J Cardiol ; 400: 131768, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38211668

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) has become an established treatment for primary and secondary mitral regurgitation (PMR and SMR). The objective of this study was to compare the accuracy of different risk scores for predicting 1-year mortality and the composite endpoint of 1-year mortality and/or heart failure (HF) hospitalization after TEER. METHODS: We analyzed data from 206 patients treated for MR at a tertiary European center between 2011 and 2023 and compared the accuracy of different mitral and surgical risk scores: EuroSCORE II, GRASP, MITRALITY, MitraScore, TAPSE/PASP-MitraScore, and STS for predicting 1-year mortality and the composite of 1-year mortality and/or HF hospitalization in PMR and SMR. A subanalysis of SMR-only patients with the addition of COAPT Risk Score and baseline N-Terminal pro-Brain Natriuretic Peptide (NT-proBNP) list was also performed. RESULTS: MITRALITY had the best discriminative ability for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with an area under the curve (AUC) of 0.74 and 0.74, respectively, in a composed group of PMR and SMR. In a SMR-only population, MITRALITY also presented the best AUC for 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization, with values of 0.72 and 0.72, respectively. CONCLUSION: MITRALITY was the best mitral TEER risk model for both 1-year mortality and the composite endpoint of 1-year mortality and/or HF hospitalization in a population of PMR and SMR patients, as well as in SMR patients only. Surgical risk scores, MitraScore, TAPSE/PASP-MitraScore and NT-proBNP alone showed poor predictive values.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Hospitalização , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
6.
Am J Cardiol ; 214: 8-17, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38104756

RESUMO

This study aimed to evaluate the incidence and clinical implications of myocardial injury, as determined by cardiac biomarker increase, in patients who underwent mitral bioprosthesis dysfunction treatment with transcatheter mitral valve replacement (TMVR) versus surgical mitral valve replacement reoperation (SMVR-REDO). Between 2014 and 2023, 310 patients with mitral bioprosthesis failure were included (90 and 220 patients for TMVR and SMVR-REDO, respectively). Multivariable analysis and propensity score matching were performed to adjust for the intergroup differences in baseline characteristics. Creatinine kinase-MB (CK-MB) and cardiac troponin I (cTn) were collected at baseline and 6 to 12, 24, 48, and 72 hours after intervention. The cardiac biomarkers values were evaluated in relation to their reference values. The outcomes were determined according to the Mitral Valve Academic Research Consortium criteria. CK-MB and cTn increased above the reference level in almost all patients after SMVR-REDO and TMVR (100% vs 94%, respectively), with the peak occurring within 6 to 12 hours. SMVR-REDO was associated with a two- to threefold higher increase in cardiac biomarkers. After 30 days, the mortality rates were 13.3% in the TMVR and 16.8% in the SMVR-REDO groups. At a median follow-up of 19 months, the mortality rates were 21.1% in the TMVR and 17.7% in the SMVR-REDO groups. Left ventricular ejection fraction, estimated glomerular filtration rate, CK-MB, and cTn were predictors of mortality. In conclusion, some degree of myocardial injury occurred systematically after the treatment of mitral bioprosthetic degeneration, especially after SMVR, and higher CK-MB and cTn levels were associated with increased cumulative late mortality, regardless of the approach.


Assuntos
Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Reoperação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Volume Sistólico , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Resultado do Tratamento , Função Ventricular Esquerda , Doenças das Valvas Cardíacas/cirurgia , Biomarcadores , Cateterismo Cardíaco/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
7.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38930026

RESUMO

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

8.
J Thromb Thrombolysis ; 35(4): 450-5, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23269561

RESUMO

Atrial fibrillation (AF) is a common co-morbidity among patients undergoing Transcatheter Aortic Valve Implantation (TAVI). Only recently have the clinical outcomes of patients with chronic or new-onset AF after TAVI been reported. The absence of clinical trials focusing on this cohort of patients has resulted in the lack of evidence based clinical guidelines. We aim to review and discuss the current literature on AF in TAVI, its clinical implications and future perspectives.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Cardiopatias Congênitas/terapia , Doenças das Valvas Cardíacas/terapia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Doença da Válvula Aórtica Bicúspide , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Feminino , Cardiopatias Congênitas/epidemiologia , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
9.
Am J Cardiol ; 205: 259-268, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37619492

RESUMO

Sacubitril-valsartan is an angiotensin receptor-neprilysin inhibitor (ARNI) associated with a decreased risk of death and hospitalization for selected patients with heart failure (HF). However, its association with improved atherosclerotic cardiovascular disease (ASCVD) events remains unclear. We performed a meta-analysis to evaluate the association of ARNI with ASCVD events in patients with HF. We systematically searched PubMed, Embase, Cochrane, and ClinicalTrials.gov for studies comparing ARNIs with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin receptor blockers (ARBs) in terms of myocardial infarction, stroke, angina pectoris, peripheral artery disease, and the composite end point in patients with HF. A total of 8 randomized controlled trials were included, with 17,541 patients assigned to either the ARNI (8,764 patients) or ACEi/ARB (8,777 patients) groups. The incidence of composite end point (risk ratio [RR] 1.03, 95% confidence interval [CI] 0.93 to 1.13, p = 0.63), myocardial infarction (RR 1.02, 95% CI 0.81 to 1.30, p = 0.85), angina pectoris (RR 0.96, 95% CI 0.80 to 1.17, p = 0.70), and stroke (RR 0.99, 95% CI 0.85 to 1.16, p = 0.93) were not statistically different between the ARNI and ACEi/ARB groups. However, ARNI was associated with a higher incidence of peripheral artery disease (RR 1.63, 95% CI 1.05 to 2.52, p = 0.03). In conclusion, this meta-analysis found no association between ARNI therapy and improved ASCVD events in patients with HF.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Insuficiência Cardíaca , Infarto do Miocárdio , Doença Arterial Periférica , Acidente Vascular Cerebral , Humanos , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Neprilisina , Doenças Cardiovasculares/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Aterosclerose/tratamento farmacológico , Aterosclerose/epidemiologia , Anti-Hipertensivos , Angina Pectoris , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/epidemiologia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/epidemiologia , Antivirais
10.
Front Cardiovasc Med ; 10: 1175600, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37388643

RESUMO

Background: Acute kidney injury (AKI) is frequently observed after transcatheter aortic valve implantation (TAVI). Of note, it is associated with a threefold increase in all-cause and cardiac death. We propose a new non-contrast strategy for evaluating and performing the TAVI procedure that can be especially valuable for patients with aortic stenosis (AS) and chronic kidney disease (CKD) to prevent AKI. Methods: Patients with severe symptomatic AS and CKD stage ≥3a were evaluated for TAVI using four non-contrast imaging modalities for procedural planning: transesophageal echocardiogram (TEE), cardiac magnetic resonance, multidetector computed tomography (MDCT), and aortoiliac CO2 angiography. Patients underwent transfemoral (TF) TAVI using the self-expandable Evolut R/Pro, and the procedures were guided by fluoroscopy and TEE. Contrast MDCT and contrast injection at certain checkpoints during the procedure were used in a blinded fashion to guarantee patient safety. Results: A total of 25 patients underwent TF-TAVI with the zero-contrast technique. The mean age was 79.9 ± 6.1 years, 72% in NYHA class III/IV, with a mean STS-PROM of 3.0% ± 1.5%, and creatinine clearance of 49 ± 7 ml/min. The self-expandable Evolut R and Pro were implanted in 80% and 20% of patients, respectively. In 36% of the cases, the transcatheter heart valve (THV) chosen was one size larger than the one by contrast MDCT, but none of these cases presented adverse events. Device success and the combined safety endpoint (at 30 days) both achieved 92%. Pacemaker implantation was needed in 17%. Conclusion: This pilot study demonstrated that the zero-contrast technique for procedural planning and THV implantation was feasible and safe and might become the preferable strategy for a significant population of CKD patients undergoing TAVR. Future studies with a larger number of patients are still needed to confirm such interesting findings.

11.
Front Cardiovasc Med ; 10: 1228305, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028447

RESUMO

Background: Periprocedural myocardial injury (PPMI) frequently occurs after transcatheter aortic valve implantation (TAVI), although its impact on long-term mortality is uncertain. Methods: We performed a pooled analysis of Kaplan-Meier-derived individual patient data to compare survival in patients with and without PPMI after TAVI. Flexible parametric models with B-splines and landmark analyses were used to determine PPMI prognostic value. Subgroup analyses for VARC-2, troponin, and creatine kinase-MB (CK-MB)-defined PPMI were also performed. Results: Eighteen observational studies comprising 10,094 subjects were included. PPMI was associated with lower overall survival (OS) after two years (HR = 1.46, 95% CI 1.30-1.65, p < 0.01). This was also observed when restricting the analysis to overall VARC-2-defined PPMI (HR = 1.23, 95% CI 1.07-1.40, p < 0.01). For VARC-2 PPMI criteria and VARC-2 troponin-only, higher mortality was restricted to the first 2 months after TAVI (HR = 1.64, 95% CI 1.31-2.07, p < 0.01; and HR = 1.32, 95% CI 1.05-1.67, p = 0.02, respectively), while for VARC-2 defined CK-MB-only the increase in mortality was confined to the first 30 days (HR = 7.44, 95% CI 4.76-11.66, p < 0.01). Conclusion: PPMI following TAVI was associated with lower overall survival compared with patients without PPMI. PPMI prognostic impact is restricted to the initial months after the procedure. The analyses were consistent for VARC-2 criteria and for both biomarkers, yet CK-MB was a stronger prognostic marker of mortality than troponin.

12.
Arq Bras Cardiol ; 120(11): e20220496, 2023 Nov.
Artigo em Português, Inglês | MEDLINE | ID: mdl-38126512

RESUMO

BACKGROUND: Central Illustration : Percutaneous Strategies in Structural Heart Diseases: Focus on Chronic Heart Failure Transcatheter devices for monitoring and treating advanced chronic heart failure patients. PA: pulmonary artery; LA: left atrium; AFR: atrial flow regulator; TASS: Transcatheter Atrial Shunt System; VNS: vagus nerve stimulation; BAT: baroreceptor activation therapy; RDN: renal sympathetic denervation; F: approval by the American regulatory agency (FDA); E: approval by the European regulatory agency (CE Mark). BACKGROUND: Innovations in devices during the last decade contributed to enhanced diagnosis and treatment of patients with cardiac insufficiency. These tools progressively adapted to minimally invasive strategies with rapid, widespread use. The present article focuses on actual and future directions of device-related diagnosis and treatment of chronic heart failure.


Assuntos
Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Simpatectomia , Átrios do Coração , Rim
13.
Front Cardiovasc Med ; 10: 1197408, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378406

RESUMO

Introduction: Classical low-flow, low-gradient aortic stenosis (LFLG-AS) is an advanced stage of aortic stenosis, which has a poor prognosis with medical treatment and a high operative mortality after surgical aortic valve replacement (SAVR). There is currently a paucity of information regarding the current prognosis of classical LFLG-AS patients undergoing SAVR and the lack of a reliable risk assessment tool for this particular subset of AS patients. The present study aims to assess mortality predictors in a population of classical LFLG-AS patients undergoing SAVR. Methods: This is a prospective study including 41 consecutive classical LFLG-AS patients (aortic valve area ≤1.0 cm2, mean transaortic gradient <40 mmHg, left ventricular ejection fraction <50%). All patients underwent dobutamine stress echocardiography (DSE), 3D echocardiography, and T1 mapping cardiac magnetic resonance (CMR). Patients with pseudo-severe aortic stenosis were excluded. Patients were divided into groups according to the median value of the mean transaortic gradient (≤25 and >25 mmHg). All-cause, intraprocedural, 30-day, and 1-year mortality rates were evaluated. Results: All of the patients had degenerative aortic stenosis, with a median age of 66 (60-73) years; most of the patients were men (83%). The median EuroSCORE II was 2.19% (1.5%-4.78%), and the median STS was 2.19% (1.6%-3.99%). On DSE, 73.2% had flow reserve (FR), i.e., an increase in stroke volume ≥20% during DSE, with no significant differences between groups. On CMR, late gadolinium enhancement mass was lower in the group with mean transaortic gradient >25 mmHg [2.0 (0.0-8.9) g vs. 8.5 (2.3-15.0) g; p = 0.034), and myocardium extracellular volume (ECV) and indexed ECV were similar between groups. The 30-day and 1-year mortality rates were 14.6% and 43.8%, respectively. The median follow-up was 4.1 (0.3-5.1) years. By multivariate analysis adjusted for FR, only the mean transaortic gradient was an independent predictor of mortality (hazard ratio: 0.923, 95% confidence interval: 0.864-0.986, p = 0.019). A mean transaortic gradient ≤25 mmHg was associated with higher all-cause mortality rates (log-rank p = 0.038), while there was no difference in mortality regarding FR status (log-rank p = 0.114). Conclusions: In patients with classical LFLG-AS undergoing SAVR, the mean transaortic gradient was the only independent mortality predictor in patients with LFLG-AS, especially if ≤25 mmHg. The absence of left ventricular FR had no prognostic impact on long-term outcomes.

14.
Eur Heart J Acute Cardiovasc Care ; 12(11): 755-764, 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37450613

RESUMO

AIMS: Chest pain is a major cause of medical evaluation at emergency department (ED) and demands observation to exclude the diagnosis of acute myocardial infarction (AMI). High-sensitivity cardiac troponin assays used as isolated measure and by 0- and 1-h algorithms are accepted as a rule-in/rule-out strategy, but there is a lack of validation in specific populations. METHODS AND RESULTS: The IN-HOspital Program to systematizE Chest Pain Protocol (IN-HOPE study) is a multicentre study that prospectively included patients admitted to the ED due to suspected symptoms of AMI at 16 sites in Brazil. Medical decisions of all patients followed the standard approach of 0 h/3 h protocol, but, in addition, blood samples were also collected at 0 and 1 h and sent to a central laboratory (core lab) to measure high-sensitivity cardiac troponin T (hs-cTnT). To assess the theoretical performance of 0 h/1 h algorithm, troponin < 12 ng/L with a delta < 3 was considered rule-out while a value ≥ 52 or a delta ≥ 5 was considered a rule-in criterion (the remaining were considered as observation group). The main objective of the study was to assess, in a population managed by the 0 h/3 h protocol, the accuracy of 0 h/1 h algorithm overall and in groups with a higher probability of AMI. All patients were followed up for 30 days, and potential events were adjudicated. In addition to the prospective cohort, a retrospective analysis was performed assessing all patients with hs-cTnT measured during the year of 2021 but not included in the prospective cohort, regardless of the indication of the test. A total of 5.497 patients were included (583 in the prospective and 4.914 in the retrospective analysis). The prospective cohort had a mean age of 57.3 (± 14.8) and 45.6% of females with a mean HEART score of 4.0 ± 2.2. By the core lab analysis, 74.4% would be eligible for a rule-out approach (45.3% of them with a HEART score > 3) while 7.3% would fit the rule-in criteria. In this rule-out group, the negative predictive value for index AMI was 100% (99.1-100) overall and regardless of clinical scores. At 30 days, no death or AMI occurred in the rule-out group of both 0/1 and 0/3 h algorithms while 52.4% of the patients in the rule-in group (0 h/1 h) were considered as AMI by adjudication. In the observation group (grey zone) of 0 h/1 h algorithm, GRACE discriminated the risk of these patients better than HEART score. In the retrospective analysis, 1.091 patients had a troponin value of <5 ng/L and there were no cardiovascular deaths at 30 days in this group. Among all 4.914 patients, the 30-day risk of AMI or cardiovascular death increased according to the level of troponin: 0% in the group < 5 ng/L, 0.6% between 5 and 14 ng/L, 2.2% between 14 and 42 ng/L, 6.3% between 42 and 90 ng/L, and 7.7% in the level ≥ 90 ng/L. CONCLUSION: In this large multicentre study, a 0 h/1 h algorithm had the potential to classify as rule-in or rule-out in almost 80% of the patients. The rule-out protocol had high negative predictive value regardless of clinical risk scores. Categories of levels of hs-cTn T also showed good accuracy in discriminating risk of the patients with a very favourable prognosis for cardiovascular death in the group with value < 5 ng/L. CLINICALTRIALS.GOV: NCT04756362.


Assuntos
Infarto do Miocárdio , Troponina T , Feminino , Humanos , Pessoa de Meia-Idade , Algoritmos , Biomarcadores , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Serviço Hospitalar de Emergência , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/epidemiologia , Estudos Prospectivos , Estudos Retrospectivos , Troponina I , Masculino , Adulto , Idoso
15.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
16.
J Cardiol Cases ; 25(2): 61-64, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079298

RESUMO

Coronary obstruction is an uncommon and severe complication after a transcatheter aortic valve replacement (TAVR), that occurs during the procedure in the vast majority of patients. In the present case even in the absence of classic risk factors, an acute coronary syndrome occurred one day after TAVR. Selective angiography revealed a severe left main ostium obstruction by the bulky native leaflet calcification. This is the first case of delayed presentation of coronary obstruction with a transfemoral balloon-expandable valve using the Inovare bioprosthesis (Braile Biomedica, Brazil). In addition, after drug-eluting stent placement in the left main coronary, intravascular ultrasound revealed severe stent underexpansion, so that a second layer of a bare-metal stent and high-pressure balloon post-dilatation was necessary to improve the final result. The patient was discharged after 7 days, and at the 6-month follow-up remained asymptomatic. .

17.
Arq Bras Cardiol ; 118(6): 1085-1096, 2022.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35703645

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a worldwide adopted procedure with rapidly evolving practices. Regional and temporal variations are expected to be found. OBJECTIVE: To compare TAVR practice in Latin America with that around the world and to assess its changes in Latin America from 2015 to 2020. METHODS: A survey was applied to global TAVR centers between March and September 2015, and again to Latin-American centers between July 2019 and January 2020. The survey consisted of questions addressing: i) center's general information; ii) pre-TAVR evaluation; iii) procedural techniques; iv) post-TAVR management; v) follow-up. Answers from the 2015 survey of Latin-American centers (LATAM15) were compared with those of other centers around the world (WORLD15) and with the 2020 updated Latin-American survey (LATAM20). A 5% level of significance was adopted for statistical analysis. RESULTS: 250 centers participated in the 2015 survey (LATAM15=29; WORLD15=221) and 46 in the LATAM20. Combined centers experience accounted for 73 707 procedures, with WORLD15 centers performing, on average, 6- and 3-times more procedures than LATAM15 and LATAM20 centers, respectively. LATAM centers performed less minimalistic TAVR than WORLD15 centers, but there was a significant increase in less invasive procedures after 5 years in Latin-American centers. For postprocedural care, a lower period of telemetry and maintenance of temporary pacing wire, along with less utilization of dual antiplatelet therapy was observed in LATAM20 centers. CONCLUSION: Despite still having a much lower number of procedures, many aspects of TAVR practice in Latin-American centers have evolved in recent years, followingthe trend observed in developed country centers.


FUNDAMENTO: Implante transcateter de valva aórtica (TAVI) é um procedimento adotado em todo o mundo e suas práticas evoluem rapidamente. Variações regionais e temporais são esperadas. OBJETIVO: Comparar a prática de TAVI na América Latina com aquela no resto do mundo e avaliar suas mudanças na América Latina de 2015 a 2020. MÉTODO: A pesquisa foi realizada em centros de TAVI em todo o mundo entre março e setembro de 2015, e novamente nos centros latino-americanos entre julho de 2019 e janeiro de 2020. As seguintes questões foram abordadas: i) informação geral sobre os centros; ii) avaliação pré-TAVI; iii) técnicas do procedimento; iv) conduta pós-TAVI; v) seguimento. As respostas da pesquisa dos centros latino-americanos em 2015 (LATAM15) foram comparadas àquelas dos centros no resto do mundo (WORLD15) e ainda àquelas da pesquisa dos centros latino-americanos de 2020 (LATAM20). Adotou-se o nível de significância de 5% na análise estatística. RESULTADOS: 250 centros participaram da pesquisa em 2015 (LATAM15=29; WORLD15=221) e 46 na avaliação LATAM20. No total, foram 73.707 procedimentos, sendo que os centros WORLD15 realizaram, em média, 6 e 3 vezes mais procedimentos do que os centros LATAM15 e LATAM20, respectivamente. Os centros latino-americanos realizaram menor número de TAVI minimalista do que os do restante do mundo, mas aumentaram significativamente os procedimentos menos invasivos após 5 anos. Quanto à assistência pós-procedimento, observaram-se menor tempo de telemetria e de manutenção do marca-passo temporário, além de menor uso de terapia dupla antiplaquetária nos centros LATAM20. CONCLUSÃO: A despeito do volume de procedimentos ainda significativamente menor, muitos aspectos da prática de TAVI nos centros latino-americanos evoluíram recentemente, acompanhando a tendência dos centros dos países desenvolvidos.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , América Latina , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
18.
J Cardiol Cases ; 26(3): 181-185, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36091613

RESUMO

Patients presenting with aortic stenosis and atrial fibrillation (AF) undergoing transcatheter aortic valve replacement (TAVR) are commonly at increased risk for stroke and bleeding complications. Concomitant left atrial appendage occlusion (LAAO) after TAVR may be an alternative to oral anticoagulation (OAC).Between 2018 and 2022, 7 consecutive patients who were ineligible for OAC underwent simultaneous TAVR and LAAO. The mean age was 84.9 ±â€¯4.9 years. The mean CHA2DS2-VASc, HAS-BLED, and STS predicted risk of mortality scores were 5.9 ±â€¯0.7, 3.9 ±â€¯1.1, and 8.8 ±â€¯3.4%, respectively. The median follow-up time was 23 (1 to 27) months. All procedures achieved technical success and no adverse events were observed during follow-up. This case series shows that concomitant TAVR and LAAO is feasible and safe among patients with severe aortic stenosis and AF who are deemed ineligible for OAC. Learning objectives: Atrial fibrillation is the most common arrhythmia in the transcatheter aortic valve replacement (TAVR) population. In those who experience major or life-threatening bleeding, mortality is doubled. We report a case series of 7 concomitant left atrial appendage occlusions (LAAO) after TAVR in patients ineligible for oral anticoagulation. All procedures achieved technical success and no adverse events were observed. The simultaneous approach with TAVR and LAAO was feasible and safe in this case series.

19.
Arq Bras Cardiol ; 117(3): 512-517, 2021 09.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34231795

RESUMO

BACKGROUND: Heyde's syndrome is the association of severe aortic stenosis with episodes of gastrointestinal bleeding due to angiodysplastic lesion. Little is known about the factors associated with new episodes of bleeding and long-term outcomes. Furthermore, most data are restricted to case reports and small case series. OBJECTIVE: To assess the clinical, laboratory and echocardiography profile of patients with Heyde's syndrome who underwent valve intervention or drug therapy. METHODS: Prospective cohort of 24 consecutive patients from 2005 to 2018. Clinical, laboratory and echocardiography data were assessed, as well as those related to valve intervention and outcomes after diagnosis. A P <0.05 was used to indicate statistical significance. RESULTS: Half of the 24 patients presented with bleeding requiring blood transfusion on admission. Angiodysplasias were more frequently found in the ascending colon (62%). Valve intervention (surgical or transcatheter) was performed in 70.8% of the patients, and 29.2% remained on drug therapy. News episodes of bleeding occurred in 25% of the cases, and there was no difference between clinical and intervention groups (28.6 vs 23.5%, p = 1.00; respectively). Mortality at 2-year and 5-year was 16% and 25%, with no difference between the groups (log-rank p = 0.185 and 0.737, respectively). CONCLUSIONS: Patients with Heyde's syndrome had a high rate of bleeding requiring blood transfusion on admission, suggesting that it is a severe disease with high mortality risk. No difference was found between clinical and intervention group regarding the rate of rebleeding and late mortality.


FUNDAMENTOS: A síndrome de Heyde é a associação de estenose aórtica importante com episódio de sangramento gastrointestinal por lesões angiodisplásicas. Pouco é conhecido sobre os fatores associados a novos sangramentos e desfechos em longo prazo. Além disso, a maioria dos dados é restrita a relatos de casos e pequenas séries. OBJETIVO: Avaliar o perfil clínico, laboratorial e ecocardiográfico de pacientes com síndrome de Heyde submetidos a intervenção valvar ou tratamento medicamentoso. MÉTODOS: Coorte prospectiva de 24 pacientes consecutivos entre 2005 e 2018. Foram avaliados dados clínicos, laboratoriais, ecocardiográficos e relacionados à intervenção valvar e a desfechos após o diagnóstico. Valor de p<0,05 foi considerado estatisticamente significante. RESULTADOS: Metade dos 24 pacientes apresentou sangramento com necessidade de transfusão sanguínea na admissão. Angiodisplasias foram encontradas mais frequentemente no cólon ascendente (62%). Intervenção valvar (cirúrgica ou transcateter) foi realizada em 70,8% dos pacientes, e 29,2% foram mantidos em tratamento clínico. Novos episódios de sangramento ocorreram em 25% dos casos, e não houve diferença entre os grupos clínico e intervenção (28,6 vs. 23,5%, p=1,00; respectivamente). A mortalidade no seguimento de 2 e 5 anos foi de 16% e 25%, sem diferença entre os grupos (log-rank p = 0,185 e 0,737, respectivamente). CONCLUSÕES: Pacientes com síndrome de Heyde tiveram alta taxa de sangramento com necessidade de transfusão sanguínea na admissão, sugerindo ser uma doença grave e com risco elevado de mortalidade. Não encontramos diferenças entre os grupos submetidos ao tratamento clínico e à intervenção valvar em relação a taxas de ressangramento e mortalidade tardia.


Assuntos
Angiodisplasia , Estenose da Valva Aórtica , Angiodisplasia/complicações , Angiodisplasia/terapia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Humanos , Estudos Prospectivos
20.
Front Cardiovasc Med ; 8: 694339, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34422923

RESUMO

Background: Bioprosthetic heart valve has limited durability and lower long-term performance especially in rheumatic heart disease (RHD) patients that are often subject to multiple redo operations. Minimally invasive procedures, such as transcatheter valve-in-valve (ViV) implantation, may offer an attractive alternative, although data is lacking. The aim of this study was to evaluate the baseline characteristics and clinical outcomes in rheumatic vs. non-rheumatic patients undergoing ViV procedures for severe bioprosthetic valve dysfunction. Methods: Single center, prospective study, including consecutive patients undergoing transcatheter ViV implantation in aortic, mitral and tricuspid position, from May 2015 to September 2020. RHD was defined according to clinical history, previous echocardiographic and surgical findings. Results: Among 106 patients included, 69 had rheumatic etiology and 37 were non-rheumatic. Rheumatic patients had higher incidence of female sex (73.9 vs. 43.2%, respectively; p = 0.004), atrial fibrillation (82.6 vs. 45.9%, respectively; p < 0.001), and 2 or more prior surgeries (68.1 vs. 32.4%, respectively; p = 0.001). Although, device success was similar between groups (75.4 vs. 89.2% in rheumatic vs. non-rheumatic, respectively; p = 0.148), there was a trend toward higher 30-day mortality rates in the rheumatic patients (21.7 vs. 5.4%, respectively; p = 0.057). Still, at median follow-up of 20.7 [5.1-30.4] months, cumulative mortality was similar between both groups (p = 0.779). Conclusion: Transcatheter ViV implantation is an acceptable alternative to redo operations in the treatment of patients with RHD and severe bioprosthetic valve dysfunction. Despite similar device success rates, rheumatic patients present higher 30-day mortality rates with good mid-term clinical outcomes. Future studies with a larger number of patients and follow-up are still warranted, to firmly conclude on the role transcatheter ViV procedures in the RHD population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA