Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Thorac Cardiovasc Surg ; 71(1): 29-37, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-33782937

RESUMO

BACKGROUND: Treatment of severe necrotizing aortic root endocarditis (SNARE) carries a substantial perioperative risk. As an alternative to homografts, we assessed short-term outcome and future prognosis in patients undergoing root replacement using the Freestyle valve. METHODS: Between 2000 and 2018, a total of 45 patients (mean age 70.9 ± 8.3 years, 66% men) underwent aortic root replacement for SNARE using the Freestyle valve. Mean Society of Thoracic Surgeons mortality score and EuroScore II were 22.6% ± 17.1 and 29.3% ± 20.9, respectively. Prosthetic endocarditis was present in 70.1%, and aortic annulus patch repair was performed in 64% of the patients. Median follow-up was 3.6 years (range: 0.1-14.5) and was 100% complete. RESULTS: The 30-day mortality was 15.5%. During follow-up, there were no reoperations, while reinfection was suspected in one patient. Survival was significantly inferior to the general population with a standardized mortality ratio of 10.7 (95% confidence interval [CI]: 9.1-12.6) (p < 0.0001). In 30-day survivors and after correction for significant comorbidities in a Cox proportional hazards model, estimated survival probabilities at 1, 5, and 10 years were 98.7 (95% CI: 92.5-99.8%), 94.1 (77.9-98.5%), and 63.8 (28.4-85.2%). Estimated mean difference in survival probability was better for the general population after postoperative year 6, but within the 95% CI for no difference. CONCLUSION: Use of the Freestyle valve is reliable solution for the most complex cases with a low rate of reinfection. Early mortality is substantial and caused by the patient's condition and severity of the infection. Excess late mortality can be attributed to patient-specific comorbidities.


Assuntos
Bioprótese , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aorta Torácica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Endocardite/complicações , Endocardite/diagnóstico , Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Reinfecção , Estudos Retrospectivos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991385

RESUMO

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Circulation ; 139(16): 1865-1871, 2019 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-30732456

RESUMO

BACKGROUND: The 30-day and 1-year follow-up analysis of the GOPCABE trial (German Off-Pump Coronary Artery Bypass Grafting in Elderly Patients) revealed no significant difference in the composite end point consisting of death, stroke, myocardial infarction, new renal replacement therapy, or repeat revascularization. The 5-year follow-up data of this trial are reported here. METHODS: From June 2008 to September 2011, a total of 2539 patients aged ≥75 years were randomly assigned to undergo off-pump or on-pump coronary artery bypass grafting (CABG) at 12 centers in Germany. The primary outcome was all-cause mortality at 5 years. The secondary 5-year outcomes were a composite of death, myocardial infarction, and repeat revascularization. Furthermore, the impact of complete versus incomplete revascularization was assessed. RESULTS: After a median follow-up of 5 years, 361 patients (31%) assigned to off-pump CABG and 352 patients (30%) assigned to on-pump CABG had died (hazard ratio off-pump/on-pump CABG, 1.03; 95% CI, 0.89-1.19; P=0.71). The composite outcome of death, myocardial infarction, and repeat revascularization occurred in 397 (34%) after off-pump and in 389 (33%) after on-pump CABG (hazard ratio, 1.03; 95% CI, 0.89-1.18; P=0.704). Incomplete revascularization occurred in 403 (34%) patients randomly assigned to off-pump and 354 (29%) patients randomly assigned to on-pump CABG ( P<0.001). Five-year survival rates were 72% (95% CI, 67-76) with incomplete versus 76% (95% CI, 74-80) with complete revascularization (log-rank test: P=0.02) after off-pump CABG and 72% (95% CI, 67-76) versus 77% (95% CI, 74-80) after on-pump CABG (log-rank test: P=0.03), respectively. Cox regression analysis revealed a hazard ratio incomplete/complete revascularization of 1.19 (95% CI, 1.01-1.39; P=0.04). CONCLUSIONS: In elderly patients ≥75 years of age, the 5-year survival rates and the combined outcome of death, myocardial infarction, and repeat revascularization, as well, were similar after on-pump and off-pump CABG. Incomplete revascularization was associated with a lower 5-year survival rate, irrespective of the type of surgery. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00719667.


Assuntos
Ponte de Artéria Coronária , Coração Auxiliar , Infarto do Miocárdio/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
4.
Thorac Cardiovasc Surg ; 68(6): 478-485, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-30452076

RESUMO

BACKGROUND: Functional tricuspid regurgitation (FTR) secondary to left-sided heart disease may lead to poor quality of life and reduced long-term survival. This study evaluated clinical and functional outcomes of patients undergoing tricuspid valve (TV) repair using a rigid three-dimensional ring (Contour 3D, Medtronic) concomitant with another procedure. METHODS: From September 2011 to July 2015, 112 patients (mean age 70.9 ± 9.0 years) were enrolled at 10 centers in Europe, Israel, and the United States. Inclusion criteria were FTR ≥ moderate and/or tricuspid annular diameter (TAD) ≥ 40 mm. Echocardiography was planned before surgery and at discharge with echocardiographic and clinical follow-ups performed 6 months postoperatively. RESULTS: Three fourths (74.4%) of patients had higher than moderate TR. Mean TAD was 41.0 ± 7.3 mm; 61.7% of patients were in the New York Heart Association (NYHA) class III/IV. The most common concomitant procedure was mitral valve repair (57 patients, 53.3%). The 30-day mortality rate was 0.9% (n = 1). The mean EuroSCORE II was 8.9 ± 8.4% (median: 5.9%; interquartile range: 3.5-11.5%). The observed to expected ratio (O/E) based on the median was 0.1. Six deaths occurred during follow-up (three cardiac related). Mean implanted ring size was 30.3 ± 2.7. At 6 months, 94.4% of patients showed ≤ mild TR, and 92.0% were in NYHA class I/II (p < 0.001 vs baseline for both). Mean pressure gradient across the TV was 2.0 ± 1.1 mm Hg; leaflet coaptation length was 7.5 ± 3.3 mm. CONCLUSION: The Contour 3D annuloplasty ring used for treatment of FTR substantially reduced TR for up to 6 postoperative months with low mean pressure gradients across the TV and significant improvement in NYHA class. REGISTRATION: www.ClinicalTrials.gov, NCT01532921.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/mortalidade , Complicações Pós-Operatórias/mortalidade , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/fisiopatologia , Estados Unidos
5.
Catheter Cardiovasc Interv ; 92(7): 1374-1379, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29521464

RESUMO

BACKGROUND: Evolut-R 34 mm (received CE mark in January 2017) and Sapien-3 29 mm are the only options for transcatheter aortic valve replacement (TAVR) in patients with annulus ≥26 mm. We compared the short-term outcomes of these valves in these patients. METHODS: Data was collected prospectively from consecutive patients with severe aortic stenosis and annulus diameter larger than 26 mm treated by femoral approach TAVR. RESULTS: Between February 1, 2014 to August 19, 2017 Sapien-3 29 mm was implanted in 55 and Evolut-R 34 mm in 37 consecutive patients. Device success rate was 98.2% and 97.3% (P = 1.0) and the composite peri-procedural complication rate was 7.3% and 2.7% (P = .645) in Sapin-3 29 mm and Evolut-R 34 mm, respectively. Composite endpoint of early safety in-hospital did not differ significantly [5(9.2%) vs 3(8.1%), P = 1.00], respectively. Prosthetic valve Gradients were significantly lower with Evolut-R 34 mm [maximal (18.0 ± 5.8 vs 11.2 ± 4.8 mmHg, P < .001) and mean (10.0 ± 3.3 vs 6.3 ± 2.7 mmHg, P < .001)]. Pacemaker implantation rate was high in both groups, and numerically but not statistically significant higher with Evolut-R [10/50 (20.0%) vs 8/28 (28.6%), P = .389]. CONCLUSIONS: As compared to Sapien-3 29 mm the Evolut-R 34 mm is a real alternative for TAVR in patients with a large annulus with a comparable peri-procedural complication rate, better hemodynamic results but a trend for higher pacemaker rate.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Thorac Cardiovasc Surg ; 66(6): 464-469, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29566406

RESUMO

BACKGROUND: Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (off-pump CABG) may reduce severe adverse events including stroke. METHODS: In the German Off-Pump Coronary Artery Bypass Grafting in Elderly patients trial, the rate of major adverse cardiovascular events was compared in 2,394 elderly (≥ 75 years) patients undergoing CABG with (on-pump) or without (off-pump) cardiopulmonary bypass. This exploratory post-hoc analysis investigated the impact of surgical aortic manipulation on the rate of stroke. RESULTS: There was no significant difference in the rate of stroke within 30 days after surgery between both groups (off-pump: 2.2%; on-pump: 2.7%; odds ratio [OR]: 0.83 [0.5-1.38]; p = 0.47). Within the off-pump group, different degrees of aortic manipulation did not lead to significant different stroke rates (tangential clamping: 2.3%; OR 0.86 [0.46-1.60]; clampless device: 1.8%; OR 0.67 [0.26-1.75]; no aortic manipulation: 2.4%; OR 0.88 [0.37-2.14]). An aggregate analysis including more than 10,000 patients out of the four recent major trials also yielded comparable stroke rates for on- and off-pump CABG (off-pump: 1.4%; on-pump: 1.7%; OR 0.87 [0.64-1.20]). CONCLUSION: Within recent prospective randomized multicenter trials off-pump CABG did not result in lower stroke rates. The possible intrinsic benefit of off-pump CABG may be offset by the complexity of the operative therapy as well as the multiple pathomechanisms involved in perioperative stroke.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Projetos de Pesquisa , Acidente Vascular Cerebral/etiologia , Fatores Etários , Idoso , Ponte Cardiopulmonar/mortalidade , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária sem Circulação Extracorpórea/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Alemanha , Humanos , Masculino , Razão de Chances , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Fatores de Tempo , Resultado do Tratamento
7.
Cardiology ; 136(3): 170-179, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27698326

RESUMO

BACKGROUND: This is an investigation of complete arterial coronary artery bypass grafting (CACABG) using bilateral internal mammary arteries (IMA) and the T-graft technique either on- or off-pump as a routine approach to treat coronary artery disease. METHODS: Between January 2000 and December 2012, 3,445 patients underwent on-pump (n = 2,216) or off-pump (n = 1,229) CACABG. A 30-day follow-up was performed prospectively, a long-term follow-up by a questionnaire, and coronary angiography in selected patients. RESULTS: End points at 30 days were death, myocardial infarction, stroke, repeat revascularization, renal replacement, reoperation, sternal wound infection and atrial fibrillation. FitzGibbon A patency rates were 89.8 vs. 91.4% (p = 0.464) with consecutive percutaneous coronary intervention in the grafted area of 1.8 vs. 1.1% (p = 0.693) on- vs. off-pump, and no reoperation in the grafted area in both groups. CONCLUSION: CACABG by use of skeletonized bilateral IMA with the T-graft technique performed either on- or off-pump is a safe and effective approach.


Assuntos
Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/cirurgia , Idoso , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Alemanha , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
N Engl J Med ; 368(13): 1189-98, 2013 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-23477657

RESUMO

BACKGROUND: The benefits of coronary-artery bypass grafting (CABG) without cardiopulmonary bypass in the elderly are still undetermined. METHODS: We randomly assigned patients 75 years of age or older who were scheduled for elective first-time CABG to undergo the procedure either without cardiopulmonary bypass (off-pump CABG) or with it (on-pump CABG). The primary end point was a composite of death, stroke, myocardial infarction, repeat revascularization, or new renal-replacement therapy at 30 days and at 12 months after surgery. RESULTS: A total of 2539 patients underwent randomization. At 30 days after surgery, there was no significant difference between patients who underwent off-pump surgery and those who underwent on-pump surgery in terms of the composite outcome (7.8% vs. 8.2%; odds ratio, 0.95; 95% confidence interval [CI], 0.71 to 1.28; P=0.74) or four of the components (death, stroke, myocardial infarction, or new renal-replacement therapy). Repeat revascularization occurred more frequently after off-pump CABG than after on-pump CABG (1.3% vs. 0.4%; odds ratio, 2.42; 95% CI, 1.03 to 5.72; P=0.04). At 12 months, there was no significant between-group difference in the composite end point (13.1% vs. 14.0%; hazard ratio, 0.93; 95% CI, 0.76 to 1.16; P=0.48) or in any of the individual components. Similar results were obtained in a per-protocol analysis that excluded the 177 patients who crossed over from the assigned treatment to the other treatment. CONCLUSIONS: In patients 75 years of age or older, there was no significant difference between on-pump and off-pump CABG with regard to the composite outcome of death, stroke, myocardial infarction, repeat revascularization, or new renal-replacement therapy within 30 days and within 12 months after surgery. (Funded by Maquet; GOPCABE ClinicalTrials.gov number, NCT00719667.).


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/etiologia , Complicações Pós-Operatórias , Modelos de Riscos Proporcionais , Qualidade de Vida , Insuficiência Renal/etiologia , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia
9.
Cardiology ; 116(3): 213-8, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20689278

RESUMO

OBJECTIVES: An increasing number of elderly patients develop aortic valve disease requiring surgery. Operative risk scores are currently used to identify patients at high operative risk who may benefit from interventional treatment options. The aim of this study was to analyze the predictive value of these risk scores in geriatric patients undergoing aortic valve replacement. METHODS: We reviewed data of 1,245 elderly patients who underwent aortic valve replacement with or without additional bypass surgery from 2000-2007. Patient data were derived from a prospective registry at the Department of Cardiac Surgery at Albertinen-Hospital in Hamburg, Germany. RESULTS: Hospital mortality was 2.56% in isolated valve replacement and 3.38% in patients who had additional bypass surgery (p = ns). Age >80 years (OR 1.7; 95% CI: 1.3-3.3) and renal failure (OR 1.6; 95% CI: 1.1-2.5) were significantly associated with in-hospital death. All scores overestimated operative mortality. The median logistic EuroSCORE was 11.56% (interquartile range: 7.01-18.96), median STS score 13.9% (10.3-16.2); and median Ambler score 7.2% (4.1-9.3). There was a significant correlation of the STS score with operative mortality (Spearman's rank coefficient: 0.68), but not with EuroSCORE (Spearman's rank coefficient: 0.11) or Ambler score (Spearman's rank coefficient: -0.17). CONCLUSION: Current risk scores overestimate operative risk in geriatric patients undergoing aortic valve replacement substantially. Of the risk scores evaluated, only STS score correlated significantly with operative mortality. Operative risk scores aimed specifically at geriatric patients may be necessary to accurately identify patients at high operative risk who benefit from non-surgical treatment options.


Assuntos
Estenose da Valva Aórtica/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Avaliação de Resultados em Cuidados de Saúde/métodos , Medição de Risco/métodos , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Comorbidade , Feminino , Alemanha/epidemiologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Sistema de Registros , Insuficiência Renal/complicações , Insuficiência Renal/mortalidade
10.
Thromb Haemost ; 101(3): 557-62, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19277420

RESUMO

Alteplase is standard therapy for patients with acute, massive pulmonary embolism. The novel plasminogen activator desmoteplase displays high fibrin specificity and selectivity for fibrinbound plasminogen. In a preclinical model desmoteplase was twice as potent with a shorter lysis time and lower reocclusion rate. We conducted a phase II study comparing 125, 180, and 250 microg/kg bodyweight desmoteplase with 100 mg alteplase. Efficacy criteria were total pulmonary resistance (TPR), mean pulmonary artery pressure (mPAP), and Miller Index. Intention to treat analysis of 34 patients. The reduction of TPR after 24 hours was comparable between desmoteplase 180 microg/kg and alteplase (-48.0 +/- 22.4 vs. -50.4 +/- 16.3%; p = n.s. vs. alteplase; p = 0.0002 and p<0.0001 vs. baseline). The greatest effect was achieved with desmoteplase 250 microg/kg (-56.0 +/- 29.4%; p = n.s. vs. alteplase, p = 0.0055 vs. baseline). Two hours after treatment PAP was reduced by 27.9 (p = 0.0004 vs. baseline) and 30.4% (p = 0.015 vs. baseline) with the higher doses of desmoteplase and 29.6% with alteplase (p = 0.0006 vs. baseline). Further PAP reduction after 6 hours was most pronounced in the desmoteplase 250 microg/kg group (-40.1 +/- 18.0%; p = 0.0028 vs. baseline). The reduction of the Miller Index was greatest using desmoteplase 250 microg/kg (-35.0 +/- 21.7%; p = 0.011 vs. baseline), and alteplase (-41.6 +/- 27.2%; p = 0.0003 vs. baseline). Safety did not differ among the 4 groups. The study results suggest that desmoteplase at doses of 180 and 250 microg/kg had similar or greater efficacy compared to alteplase 100 mg. Onset of action was faster, safety was comparable.


Assuntos
Fibrinolíticos/uso terapêutico , Ativadores de Plasminogênio/uso terapêutico , Embolia Pulmonar/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Esquema de Medicação , Feminino , Fibrinogênio/análise , Fibrinolíticos/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Ativadores de Plasminogênio/farmacologia , Pressão Propulsora Pulmonar/efeitos dos fármacos , Ativador de Plasminogênio Tecidual/farmacologia , Resistência Vascular/efeitos dos fármacos , Adulto Jovem
11.
Int J Artif Organs ; 42(4): 194-200, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30803290

RESUMO

Infective endocarditis is caused by a bacterial infection of the endocardial surface, and despite improvements in surgical interventions and antimicrobial therapy, mortality remains high. Recently published data suggest that intraoperative hemoadsorption therapy might represent a promising treatment option; however, randomized data still lack, and a comparative study on the intraoperative versus intraoperative plus postoperative use of CytoSorb has not yet been performed. We hypothesized that patients developing intraoperative renal failure benefit from additional postoperative CytoSorb treatment in terms of outcome. We examined the application of hemoadsorption therapy in 20 endocarditis patients separated into two groups: (1) sole intraoperative versus (2) intraoperative plus postoperative treatment, with regard to inflammatory and hemodynamic status, the postoperative course including development of complications, extent of extracorporeal organ support, and outcome. Despite an obviously more pronounced disease severity in the intraoperative plus postoperatively treated patients as evidenced by a higher initial European System for Cardiac Operative Risk Evaluation score, higher reoperation rate, longer cardiopulmonary bypass times, a worse inflammatory status, and perioperative development of acute renal failure, we observed a clear and comparable stabilization in hemodynamics and inflammatory parameters in both groups. More importantly and despite a higher rate of postoperative complications and a longer intensive care unit stay, patients from the intraoperative plus postoperative group showed an equal intensive care unit and 90-day survival compared to patients treated only intraoperatively. Our data suggest that postoperative continuation of hemoadsorption treatment might be beneficial in patients with endocarditis who develop perioperative renal failure in combination with severe hemodynamic instability and high-grade intraoperative findings.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Endocardite Bacteriana/terapia , Hemofiltração/métodos , Cuidados Intraoperatórios/métodos , Cuidados Pós-Operatórios/métodos , Complicações Pós-Operatórias , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/fisiopatologia , Endocardite Bacteriana/cirurgia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Índice de Gravidade de Doença , Resultado do Tratamento
12.
Ann Thorac Surg ; 105(3): 763-769, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29289363

RESUMO

BACKGROUND: The Mosaic bioprosthesis is a third-generation stented porcine bioprosthesis. This study was performed to evaluate long-term survival and durability associated with this device. METHODS: A total of 1,029 patients (797 aortic valve replacements, 232 mitral valve replacements) previously enrolled at 6 centers as part of the original regulatory study were included. We evaluated freedom from death, valve-related reoperation, and explant due to structural valve deterioration (SVD), and compared these outcomes by age (<60 and ≥60 years) at the time of implant. RESULTS: Cumulative follow-up was 7021.2 patient-years in the aortic cohort and 1969.5 patient-years in the mitral cohort. Mean age was 69.5 ± 8.6 and 67.9 ± 10.5 years; 66% and 48% were male, respectively. In the aortic cohort at 17 years, freedom from death was 54.0% in patients younger than 60 years and 24.0% in patients aged 60 years and older (p < 0.01); freedom from reoperation was 36.4% and 81.2%, respectively (p < 0.01); and freedom from explant due to SVD was 47.5% and 89.1% (p < 0.01). At 16 years in the mitral cohort, freedom from death was 67.6% and 20.6% (p < 0.01); freedom from reoperation was 51.3% versus 77.9% (p = 0.04); and freedom from explant due to SVD was 65.2% versus 83.8% (p = 0.23). CONCLUSIONS: This study demonstrates acceptable long-term rates of death, reoperation, and explant due to SVD with the Mosaic bioprosthesis implanted in either the aortic or mitral position. Freedom from explant due to SVD was lower in patients younger than 60 years in the aortic cohort at 17 years, but it was not significantly different between patients younger than 60 years or 60 years and older in the mitral cohort at 16 years.


Assuntos
Valva Aórtica , Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Fatores Etários , Idoso , Animais , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Stents , Taxa de Sobrevida , Suínos , Resultado do Tratamento
13.
Eur J Cardiothorac Surg ; 52(5): 917-923, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29029008

RESUMO

OBJECTIVES: Higher rates of mortality and morbidity have been reported in women undergoing coronary artery bypass grafting (CABG) compared with men. Different revascularization techniques (on-pump and off-pump) might influence this outcome. METHODS: We retrospectively analysed 3445 consecutively recruited patients (all comers) undergoing complete arterial CABG (CACABG) at a single centre between January 2000 and December 2012. CACABG was performed in all patients using bilateral skeletonized internal mammary artery in T-graft technique, either on-pump (n = 2216) or off-pump (n = 1229). Early results (30-day) and long-term follow-up data were analysed with respect to gender-specific outcome. RESULTS: Women were older than men in both groups (P < 0.001), and men had a higher body mass index (on-pump: P < 0.001; off-pump: P = 0.02) compared with women. Men displayed a higher extent of coronary artery disease (P < 0.001) and an overall lower ejection fraction (P < 0.001) when undergoing on-pump CABG. No gender differences were observed for late survival (P = 0.74 vs P = 0.52) in on-pump and off-pump procedures, respectively. Late follow-up revealed a higher rate of FitzGibbon A graft patency in men undergoing the on-pump approach (P = 0.006). CONCLUSIONS: CACABG using bilateral internal mammary artery in T-graft technique showed excellent early and long-term results. No significant gender-specific differences were observed in both groups undergoing CACABG with respect to 30 days mortality and morbidity as well as late survival. However, late follow-up revealed a higher graft patency in men undergoing the on-pump approach, compared to women.


Assuntos
Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/cirurgia , Artéria Torácica Interna/transplante , Idoso , Ponte de Artéria Coronária sem Circulação Extracorpórea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
14.
EuroIntervention ; 12(15): e1817-e1824, 2017 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-28117278

RESUMO

AIMS: The aim of this study was to determine the impact of tricuspid regurgitation (TR) on mortality after edge-to-edge percutaneous mitral valve repair (PMVR), and also to analyse whether there is a difference in outcome between patients with improvement of TR after PMVR compared to patients without. METHODS AND RESULTS: Out of 197 consecutive patients who underwent PMVR, 139 patients with available follow-up (mean 428±386 days) were included in the study. Concomitant moderate/severe TR was present in 58.3% of patients. Kaplan-Meier analysis showed significantly reduced overall survival for patients with moderate/severe TR, compared to patients with none/mild TR (p=0.003). Cox multivariate regression analysis revealed severe TR at baseline as the strongest independent predictor of mortality (HR 4.367, p=0.003). An improvement of the baseline moderate/severe TR was observed in 45.5% of patients at 30-day follow-up. Patients with no improvement of TR after PMVR had a higher midterm mortality compared to patients in whom TR improved (40.5% versus 11.4%, p=0.005). CONCLUSIONS: More than half of patients undergoing PMVR have concomitant moderate/severe TR, which is associated with a worse outcome. Among predictors of mortality after edge-to-edge PMVR, severe TR at baseline is the most important. Patients with no improvement of TR at 30 days after PMVR have a significantly higher mortality at follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
15.
Heart Surg Forum ; 9(1): E530-2, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16387670

RESUMO

BACKGROUND: Resection of the descending thoracic aorta and replacement with a vascular prosthesis is associated with an increased risk of paraplegia, as opposed to endoluminal stenting. We report on the first case in which a thoracic aortic aneurysm was treated in a hybrid approach, combining surgery with the implantation of a new intraluminal stent during 1 procedure. METHODS: A 76-year-old man with long-standing hypertension suffered from acute chest pain. Magnetic resonance imaging (MRI) revealed a complex aortic aneurysm with increased diameters of the ascending aorta (55 mm), the aortic arch (75 mm), and the descending aorta (50 mm). Supracoronary replacement of the ascending aorta with a 30-mm prosthesis was carried out during cardiopulmonary bypass, cardioplegic arrest, and hypothermia (25 degrees C). Surgery and stenting were carried out during circulatory arrest and antegrade cerebral perfusion. Two stents (length: 23 cm and 17 cm) were placed in the descending aorta via the opened aortic arch under X-ray control, covering the left subclavian artery. Then aortic arch replacement was finished by anastomosing the distal end of the aortic prosthesis to the proximal stent's customized proximal end (Polyester cuff, length 25 mm/diameter 36 mm) together with the aortic wall. The brachiocephalic trunk and left carotid artery along with a vein graft to the left subclavian artery were implanted in the prosthesis. RESULTS: Postoperative course was uneventful except for a pericardial effusion. MRI revealed normal dimensions of the thoracic aorta with complete exclusion of the aneurysm and no leakage. CONCLUSION: Simultaneous replacement of ascending aorta and aortic arch with antegrade endoluminal stenting of the descending aorta using a new type of stent were safely and effectively performed in a patient with an aortic aneurysm.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/métodos , Stents , Idoso , Aneurisma Aórtico/diagnóstico , Humanos , Imageamento por Ressonância Magnética , Masculino
16.
EuroIntervention ; 11(10): 1148-52, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26549375

RESUMO

AIMS: Transcatheter interventions with balloon-expandable valves have been shown to be efficacious for the treatment of mitral annuloplasty failure but are limited by the fact that there is no opportunity for post-implantation adjustment. The aim of this study was to assess the safety and efficacy of the fully repositionable and retrievable Direct Flow Medical (DFM) valve for the treatment of mitral annuloplasty failure. METHODS AND RESULTS: Patients who underwent transcatheter mitral valve-in-ring (VIR) implantation of a DFM valve for failed mitral annuloplasty deemed high risk for redo surgery were included at four institutions. Eight patients underwent transcatheter mitral VIR procedures with implantation of the DFM valve. The DFM prosthesis was successfully positioned in all patients. Two patients required retrieval of the device due to a suboptimal result, and a further patient required repositioning of the valve with an ultimately successful implantation. During the 30-day follow-up period, two patients died for reasons unrelated to the valve implantation. The four patients with successful implantation had normal valve function associated with a significant improvement in their functional status. CONCLUSIONS: For the first time, we demonstrate the safety, efficacy and advantages of using the DFM prosthesis for the treatment of mitral annuloplasty failure.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/instrumentação , Desenho de Prótese , Resultado do Tratamento
17.
Semin Thorac Cardiovasc Surg ; 17(1): 85-96, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16104366

RESUMO

Unfractionated heparin (UFH) is the gold standard for anticoagulation during cardiopulmonary bypass (CPB). Of patients undergoing CPB operations, 25% to 50% develop heparin-dependent antibodies during the postoperative period, typically between day 5 and 10, if UFH is continued during the postoperative course. In 1% to 3% of all patients undergoing CPB operation with UFH anticoagulation, these antibodies activate platelets causing a prothrombotic disorder, known as heparin-induced thrombocytopenia (HIT), which can lead to life-threatening thromboembolic complications. If urgent cardiac operation with the use of CPB in patients with positive antibody titer is required, different anticoagulatory approaches are available, such as lepirudin, bivalirudin, and danaparoid or UFH in combination with platelet antagonists, such as epoprostenol or tirofiban. In patients with previous HIT but no detectable antibodies, UFH alone can be used only during CPB, but alternative anticoagulation has to be used pre- and postoperatively.


Assuntos
Doenças Cardiovasculares/terapia , Heparina de Baixo Peso Molecular/efeitos adversos , Complicações Pós-Operatórias/etiologia , Trombocitopenia/induzido quimicamente , Tromboembolia/tratamento farmacológico , Anticoagulantes/uso terapêutico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/métodos , Doenças Cardiovasculares/mortalidade , Terapia Combinada , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Feminino , Seguimentos , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Medição de Risco , Taxa de Sobrevida , Trombocitopenia/mortalidade , Trombocitopenia/fisiopatologia , Tromboembolia/etiologia , Tromboembolia/mortalidade , Resultado do Tratamento
18.
JACC Cardiovasc Interv ; 8(12): 1608-13, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26386760

RESUMO

OBJECTIVES: The purpose of this study was to analyze the effect of transcatheter aortic valve replacement (TAVR) without versus with prior balloon aortic valvuloplasty (BAV) on the risk of cerebral embolization in patients who receive a balloon-expandable valve. BACKGROUND: Avoiding BAV prior to TAVR may simplify the procedure, but the risk of cerebral embolization is currently unknown. METHODS: A total of 87 consecutive high surgical-risk patients with no contraindications for diffusion-weighted magnetic resonance imaging (DW-MRI) were enrolled. Thirty-two patients received a balloon-expandable aortic valve with and 55 patients without BAV. The incidence, number, and volume of new ischemic lesions in DW-MRI performed 2 to 7 days after TAVI were evaluated. RESULTS: Mean age (83.8 ± 5.2 years vs. 82.9 ± 6.8 years) and sex (43.8% vs. 52.7% male) of the patients with versus without BAV, respectively, as well as other demographic and hemodynamic data were not significantly different between both groups. The procedural success rate was 93.5% with and 98.2% without BAV, and procedure duration and contrast volume were significantly lower without BAV. The incidence of new cerebral ischemic lesions in the total cohort was 66.7%. Compared with patients with BAV, those without BAV had a significantly higher total volume of cerebral ischemic lesions (235.4 ± 331.4 mm(3) vs. 89.5 ± 128.2 mm(3); p = 0.01). CONCLUSIONS: The implantation of a balloon-expandable aortic valve without versus with prior BAV, although performed with a shorter procedure time and lower contrast volume, is associated with a significantly higher volume of cerebral ischemic lesions.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Embolia Intracraniana/etiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/instrumentação , Estudos de Casos e Controles , Imagem de Difusão por Ressonância Magnética , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Embolia Intracraniana/diagnóstico , Masculino , Valor Preditivo dos Testes , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
JACC Cardiovasc Interv ; 8(14): 1842-9, 2015 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-26604062

RESUMO

OBJECTIVES: This study sought to evaluate the use of the Direct Flow Medical (DFM) transcatheter heart valve (Direct Flow Medical, Santa Rosa, California) for the treatment of noncalcific pure aortic regurgitation (AR). BACKGROUND: The treatment of noncalcific AR has remained a relative contraindication with transcatheter heart valves due to challenges in anchoring devices in the absence of calcium, concerns of valve embolization, and the high risk of significant residual paravalvular leak. METHODS: The study population consisted of patients treated for severe noncalcific pure AR with transfemoral implantation of a DFM transcatheter heart valve at 6 European centers. The primary endpoint was the composite endpoint of device success and the secondary endpoint was the composite early safety endpoint (according to the VARC-2 criteria). RESULTS: Eleven high-risk (STS score 8.84 ± 8.9, Logistic EuroSCORE 19.9 ± 7.1) patients (mean age 74.7 ± 12.9 years) were included. Device success was achieved in all patients. In 1 patient, the initial valve prosthesis was retrieved after pull-through, and a second valve was successfully deployed. The early safety endpoint was reached in 91% of the patients, with 1 patient requiring surgical aortic valve replacement secondary to downward dislocation of the prosthesis that was successfully managed with surgical aortic valve replacement. DFM implantation resulted in excellent hemodynamics with none or trivial paravalvular regurgitation in 9 patients and a transprosthetic gradient of 7.7 ± 5.1 mm Hg at 30-day follow up. All patients derived symptomatic benefit following the procedure, with 72% in New York Heart Association functional class I or II. CONCLUSIONS: This study reports the feasibility of treating severe noncalcific AR with the Direct Flow prosthesis via the transfemoral route.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Periférico/métodos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Europa (Continente)/epidemiologia , Feminino , Artéria Femoral , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
20.
Ann Thorac Surg ; 73(6): 1849-55, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12078780

RESUMO

BACKGROUND: Hybrid revascularization (HyR), combining minimally invasive left internal mammary artery (LIMA) bypass grafting to the left anterior descending coronary artery (LAD) and catheter interventional treatment of the remaining coronary lesions, avoids the disadvantages associated with cardiopulmonary bypass (CPB). We investigated the clinical follow-up of 57 patients with multivessel disease undergoing this procedure in the last 4 years. METHODS: Between January 1997 and January 2001, 57 consecutive patients (41 men and 16 women, aged 65.7 +/- 7.9 years) with coronary artery disease (two-vessel, n = 34; three-vessel, n = 23) were treated with off-pump LIMA-to-LAD bypass combined with balloon angioplasty and stenting of the remaining significantly obstructed (> 50%) coronary vessels. Clinical follow-up data included a early postoperative and a 6-month control angiography and a patient interview in January 2001. RESULTS: All patients underwent LIMA-to-LAD bypass-grafting and balloon angioplasty in 72 coronary lesions without procedural-related complications. However, one early LIMA bypass occlusion was documented during coronary angiography. Postoperatively no deterioration of preexistent organ dysfunction was observed in any patient. The mean follow-up was 100.7 +/- 37.9 weeks in 55 of 57 patients (97%). Control angiography 6 months after HyR (n = 34) revealed a patent LIMA bypass in 33 patients and 8 in-stent restenoses (> 50%) in the coronary arteries that were treated interventionally by re-PTCA (n = 6) or by conventional CABG (n = 1). In 1 patient medical treatment resulted in significant reduction of angina so no further intervention was considered necessary. After HyR 1 patient died 18 months later of an intracerebral hemorrhage. All other patients are alive and doing well. CONCLUSIONS: Our results indicate that in selected patients with multivessel disease including left main stem stenosis HyR is an effective and secure procedure with excellent early and good midterm results. Especially elderly patients with severe concomitant diseases appear to benefit from this approach by avoiding CPB.


Assuntos
Doença das Coronárias/cirurgia , Revascularização Miocárdica/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA