1.
Analyst ; 148(15): 3418-3431, 2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37365935

RESUMO

In recent years, magnetic nanoparticle sensor technologies have attracted considerable interest in the point-of-care-testing (POCT) field, especially in lateral flow immunoassays (LFIAs). Although the visual signal of magnetic nanoparticles is reduced during an inspection, it can be compensated for by magnetic induction, and detection results can be quantified by magnetic sensors. Sensors that use magnetic nanoparticles (MNPs) as markers can overcome the high background noise of complex samples. In this study, MNP signal detection strategies are described from the perspectives of magnetoresistance, magnetic flux, frequency mixing technology, and magnetic permeability, and the principles and development of each technology are introduced in detail. Typical applications of magnetic nanoparticle sensor technologies are introduced. By describing the advantages and limitations of different sensing strategies, we highlight the development and improvement directions of different sensing strategies. In general, the future development of magnetic nanoparticle sensor technologies will be toward intelligent, convenient, and mobile high-performance detection equipment.

2.
Analyst ; 148(23): 6020-6027, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37885378

RESUMO

Because the liver is an important metabolic center in the human body, the reliability and timeliness of chronic liver disease diagnosis are particularly important. Alanine aminotransferase and aspartate transaminase are the two most important liver function indicators, and their test results are crucial in the diagnosis of liver diseases. However, the simultaneous detection of these two indicators is currently restricted by the need for expensive equipment and complicated detection processes. This study proposes a portable dual-channel blood enzyme analyzer (BEA) for point-of-care-testing. The device uses photometric reflectance to quantify the enzyme concentration by evaluating the reflected light intensity. The BEA also precisely controls and maintains the temperature at 37 °C ± 0.1 °C in the dual-channel assay. We assessed the responses of this system within a clinically relevant range by testing blood samples from a local hospital. The test verified that BEA for ALT and AST achieved a detection limit of 3.5 U L-1 and 4 U L-1, detection range of 4-350 U L-1 and 4-250 U L-1, coefficients of variation (CV) that were both less than 10%, and a linear correlation coefficient of 0.9827 and 0.9714 compared with a high-precision clinical biochemistry analyzer (Roche Cobas C702), respectively. We realized remote data analysis and storage through connection with smartphones, which can be applied to remote diagnostics and preventative personal disease management. Therefore, BEA has broad application prospects in the future internet of medical things.


Assuntos
Fígado , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Reprodutibilidade dos Testes , Fígado/metabolismo , Alanina Transaminase/metabolismo , Aspartato Aminotransferases/metabolismo
3.
Zhonghua Yi Xue Za Zhi ; 93(31): 2478-82, 2013 Aug 20.
Artigo em Zh | MEDLINE | ID: mdl-24300269

RESUMO

OBJECTIVE: To explore the establishment of Schatzker classification digital model of tibial plateau fractures and its application in virtual surgery. METHODS: Proximal tibial of one healthy male volunteer was examined with 64-slice spiral computed tomography (CT). The data were processed by software Mimics 10.01 and a model of proximal tibia was reconstructed. According to the Schatzker classification criteria of tibial plateau fractures, each type of fracture model was simulated.Screen-captures of fracture model were saved from different directions.Each type of fracture model was exported as video mode.Fracture model was imported into FreeForm modeling system.With a force feedback device, a surgeon could conduct virtual fracture operation simulation.Utilizing the GHOST of FreeForm modeling system, the software of virtual cutting, fracture reduction and fixation was developed.With a force feedback device PHANTOM, a surgeon could manipulate virtual surgical instruments and fracture classification model and simulate surgical actions such as assembly of surgical instruments, drilling, implantation of screw, reduction of fracture, bone grafting and fracture fixation, etc. RESULTS: The digital fracture model was intuitive, three-dimensional and realistic and it had excellent visual effect.Fracture could be observed and charted from optional direction and angle.Fracture model could rotate 360 ° in the corresponding video mode. The virtual surgical environment had a strong sense of reality, immersion and telepresence as well as good interaction and force feedback function in the FreeForm modeling system. The user could make the corresponding decisions about surgical method and choice of internal fixation according to the specific type of tibial plateau fracture as well as repeated operational practice in virtual surgery system. CONCLUSION: The digital fracture model of Schatzker classification is intuitive, three-dimensional, realistic and dynamic. The virtual surgery systems of Schatzker classifications make the virtual surgery training more normalized, programmed and standardized.In addition, virtual surgery system can serve as a new tool for preoperative planning and surgeon-patient interactions.


Assuntos
Simulação por Computador , Modelos Anatômicos , Fraturas da Tíbia/classificação , Interface Usuário-Computador , Adulto , Humanos , Imageamento Tridimensional , Masculino , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Tomografia Computadorizada Espiral
SELEÇÃO DE REFERÊNCIAS