J Cardiovasc Electrophysiol ; 32(9): 2371-2378, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322918

RESUMO

BACKGROUND: Transvenous implantable cardioverter defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs. STUDY DESIGN: The EV ICD pivotal study is a prospective, multicenter, single-arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled. OBJECTIVE: The clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events. CONCLUSION: The EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Humanos , Estudos Prospectivos , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 7(11): 1387-1399, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33933410

RESUMO

OBJECTIVES: This study reports the sensing and arrhythmia detection performance of a novel extravascular (EV) implantable cardioverter-defibrillator (ICD) in a first-in-human pilot study. BACKGROUND: The EV ICD lead is implanted in the substernal space, resulting in novel sensing and detection challenges. It uses a programmable sensing profile with new or modified discrimination of oversensing and of ventricular tachycardia (VT) from supraventricular tachycardia (SVT). METHODS: Electrograms were post-processed from induced ventricular fibrillation (VF) at implant to determine virtual detection times for each programmable sensitivity and the least-sensitive safe sensitivity setting. In ambulatory patients, programmed sensitivity provided at least a twofold safety margin for detecting induced VF. Noise discrimination was stress tested, and the effects of source, posture, and lead maturation were determined on electrogram amplitude. Telemetry Holter monitors were used to quantify undersensing and oversensing. RESULTS: In 20 patients at implant, the least-sensitive safe sensitivity for VF detection ranged from 0.1 to 0.6 mV. Seventeen patients were followed up for a total of 16.6 patient-years. Electrogram amplitudes were stable over time, but there were significant differences among postures and sensing vectors. For the primary sensing vector, the weighted oversensing and undersensing rates were 1.03% and 0.40% respectively, on a beat-to-beat basis. Oversensing did not cause inappropriate therapy in patients with in situ leads. Oversensing discriminators withheld VF detection in 4 of 5 spontaneous, sustained oversensed episodes. SVT-VT discriminators correctly classified 93% of 128 sustained SVTs in monitor zones. CONCLUSIONS: In the EV ICD pilot study, oversensing did not cause inappropriate therapy during ambulatory follow-up of stable leads.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Algoritmos , Humanos , Projetos Piloto , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Fibrilação Ventricular
3.
JACC Clin Electrophysiol ; 6(12): 1525-1536, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33213813

RESUMO

OBJECTIVES: The aim of this study was to evaluate the safety and performance of an extravascular (EV) implantable cardioverter-defibrillator (ICD). BACKGROUND: Limitations of existing transvenous and subcutaneous ICD systems include lead reliability and morbidity issues associated with ICD lead implantation in the vasculature or lack of pacing therapies (e.g., antitachycardia pacing) in subcutaneous systems. The EV defibrillator uses a novel substernal lead placement to address these limitations. METHODS: This was a prospective, nonrandomized, chronic pilot study conducted at 4 centers in Australia and New Zealand. Participants were 21 patients referred for ICD implantation. Patients received EV ICD systems. Data collection included major systemic and procedural adverse events, defibrillation testing at implantation, and sensing and pacing thresholds. RESULTS: Among 20 patients who underwent successful implantation, the median defibrillation threshold was 15 J, and 90% passed defibrillation testing with a ≥10-J safety margin. Mean R-wave amplitude was 3.4 ± 2.0 mV, mean ventricular fibrillation amplitude was 2.8 ± 1.7 mV, and pacing was successful in 95% at ≤10 V. There were no intraprocedural complications. Two patients have undergone elective chronic system removal since hospital discharge. In the 15 patients presently implanted, the systems are stable in long-term follow-up. CONCLUSIONS: This first-in-human evaluation of an EV ICD demonstrated the feasibility of substernal lead placement, defibrillation, and pacing with a chronically implanted system. There were no acute major complications, and pacing, defibrillation, and sensing performance at implantation were successful in most patients. (Extravascular ICD Pilot Study [EV ICD]; NCT03608670).


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Humanos , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Fibrilação Ventricular/terapia