RESUMO
BACKGROUND: Respiratory viral infections are common and potentially devastating to patients with underlying lung disease. Diagnosing viral infections often requires invasive sampling, and interpretation often requires specialized laboratory equipment. Here, we test the hypothesis that a breath test could diagnose influenza and rhinovirus infections using an in vitro model of the human airway. METHODS: Cultured primary human tracheobronchial epithelial cells were infected with either influenza A H1N1 or rhinovirus 1B and compared with healthy control cells. Headspace volatile metabolite measurements of cell cultures were made at 12-hour time points postinfection using a thermal desorption-gas chromatography-mass spectrometry method. RESULTS: Based on 54 compounds, statistical models distinguished volatile organic compound profiles of influenza- and rhinovirus-infected cells from healthy counterparts. Area under the curve values were 0.94 for influenza, 0.90 for rhinovirus, and 0.75 for controls. Regression analysis predicted how many hours prior cells became infected with a root mean square error of 6.35 hours for influenza- and 3.32 hours for rhinovirus-infected cells. CONCLUSIONS: Volatile biomarkers released by bronchial epithelial cells could not only be used to diagnose whether cells were infected, but also the timing of infection. Our model supports the hypothesis that a breath test could serve to diagnose viral infections.
Assuntos
Doenças Transmissíveis , Vírus da Influenza A Subtipo H1N1 , Influenza Humana , Compostos Orgânicos Voláteis , Biomarcadores , Humanos , Influenza Humana/diagnóstico , Influenza Humana/metabolismo , Rhinovirus , Compostos Orgânicos Voláteis/análiseRESUMO
This is the first known community transmission case of the novel coronavirus disease (COVID-19) in the United States, with significant public health implications. Diagnosis of COVID-19 is currently confirmed with PCR based testing of appropriate respiratory samples. Given the absence of travel or known exposure history, this patient did not meet the criteria for testing according to CDC guidelines at the time of her presentation. Since this case, any patient with severe disease (eg, ARDS or pneumonia) requiring hospitalization without an explanatory diagnosis can be tested even if no clear source of exposure is identified. While influencing national health policies for revising screening criteria, this case also highlighted significant knowledge gaps in diagnosis and treatment and a desperate need for early, widespread, fast and cheap testing for COVID-19.
Assuntos
COVID-19/diagnóstico por imagem , Infecções Comunitárias Adquiridas/virologia , Síndrome do Desconforto Respiratório/virologia , Monofosfato de Adenosina/análogos & derivados , Monofosfato de Adenosina/uso terapêutico , Adulto , Alanina/análogos & derivados , Alanina/uso terapêutico , Antivirais/uso terapêutico , COVID-19/complicações , Infecções Comunitárias Adquiridas/tratamento farmacológico , Feminino , Humanos , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Fatores de Risco , Choque Séptico/etiologia , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Estados Unidos/epidemiologia , Tratamento Farmacológico da COVID-19RESUMO
Health assessments of wild cetaceans can be challenging due to the difficulty of gaining access to conventional diagnostic matrices of blood, serum and others. While the noninvasive detection of metabolites in exhaled breath could potentially help to address this problem, there exists a knowledge gap regarding associations between known disease states and breath metabolite profiles in cetaceans. This technology was applied to the largest marine oil spill in U.S. history (The 2010 Deepwater Horizon oil spill in the Gulf of Mexico). An accurate analysis was performed to test for associations between the exhaled breath metabolome and sonographic lung abnormalities as well as hematological, serum biochemical, and endocrine hormone parameters. Importantly, metabolites consistent with chronic inflammation, such as products of lung epithelial cellular breakdown and arachidonic acid cascade metabolites were associated with sonographic evidence of lung consolidation. Exhaled breath condensate (EBC) metabolite profiles also correlated with serum hormone concentrations (cortisol and aldosterone), hepatobiliary enzyme levels, white blood cell counts, and iron homeostasis. The correlations among breath metabolites and conventional health measures suggest potential application of breath sampling for remotely assessing health of wild cetaceans. This methodology may hold promise for large cetaceans in the wild for which routine collection of blood and respiratory anomalies are not currently feasible.
Assuntos
Poluição por Petróleo , Baleias/fisiologia , Animais , Testes Respiratórios , Expiração , PneumopatiasRESUMO
Monitoring health conditions is essential to detect early asymptomatic stages of a disease. To achieve this, blood, urine and breath samples are commonly used as a routine clinical diagnostic. These samples offer the opportunity to detect specific metabolites related to diseases and provide a better understanding of their development. Although blood samples are commonly used routinely to monitor health, the implementation of a relatively noninvasive technique, such as exhaled breath condensate (EBC) analysis, may further benefit the well-being of both humans and other animals. EBC analysis can be used to track possible physical or biochemical alterations caused by common diseases of the bottlenose dolphin (Tursiops truncatus), such as infections or inflammatory-mediated processes. We have used an untargeted metabolomic method with liquid chromatography-mass spectrometry analysis of EBC samples to determine biomarkers related to disease development. In this study, five dolphins under human care were followed up for 1 year. We collected paired blood, physical examination information, and EBC samples. We then statistically correlated this information to predict specific health alterations. Three dolphins provided promising case study information about biomarkers related to cutaneous infections, respiratory infections, dental disease, or hormonal changes (pregnancy). The use of complementary liquid chromatography platforms, with hydrophilic interaction chromatography and reverse-phased columns, allowed us to detect a wide spectrum of EBC biomarker compounds that could be related to these health alterations. Moreover, these two analytical techniques not only provided complementary metabolite information but in both cases they also provided promising diagnostic information for these health conditions. Graphical abstract Collection of the exhaled condensed breath from a bottlenose dolphin from U.S. Navy Marine Mammal Program (MMP).
Assuntos
Testes Respiratórios/métodos , Golfinhos/metabolismo , Metabolômica/métodos , Doenças dos Animais/diagnóstico , Doenças dos Animais/metabolismo , Animais , Biomarcadores/análise , Cromatografia Líquida/métodos , Feminino , Humanos , Masculino , Espectrometria de Massas em Tandem/métodosRESUMO
Volatile organic compounds (VOCs) emanating from humans have the potential to revolutionize non-invasive diagnostics. Yet, little is known about how these compounds are generated by complex biological systems, and even less is known about how these compounds are reflective of a particular physiological state. In this proof-of-concept study, we examined VOCs produced directly at the cellular level from B lymphoblastoid cells upon infection with three live influenza virus subtypes: H9N2 (avian), H6N2 (avian), and H1N1 (human). Using a single cell line helped to alleviate some of the complexity and variability when studying VOC production by an entire organism, and it allowed us to discern marked differences in VOC production upon infection of the cells. The patterns of VOCs produced in response to infection were unique for each virus subtype, while several other non-specific VOCs were produced after infections with all three strains. Also, there was a specific time course of VOC release post infection. Among emitted VOCs, production of esters and other oxygenated compounds was particularly notable, and these may be attributed to increased oxidative stress resulting from infection. Elucidating VOC signatures that result from the host cells response to infection may yield an avenue for non-invasive diagnostics and therapy of influenza and other viral infections.
Assuntos
Linfócitos B/metabolismo , Vírus da Influenza A Subtipo H1N1/metabolismo , Vírus da Influenza A Subtipo H9N2/metabolismo , Influenza Humana/virologia , Linfócitos B/citologia , Linfócitos B/virologia , Biomarcadores/metabolismo , Linhagem Celular , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Influenza Humana/metabolismo , Influenza Humana/patologia , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/metabolismoRESUMO
Rationale: Pulmonary innate immune cells play a central role in the initiation and perpetuation of chronic obstructive pulmonary disease (COPD), however the precise mechanisms that orchestrate the development and severity of COPD are poorly understood. Objectives: We hypothesized that the recently described family of innate lymphoid cells (ILCs) play an important role in COPD. Methods: Subjects with COPD and healthy controls were clinically evaluated, and their sputum samples were assessed by flow cytometry. A mouse model of spontaneous COPD [genetically deficient in surfactant protein-D (SP-D -/- )] and ozone (O 3 ) exposure were used to examine the mechanism by which lack of functional SP-D may skew ILC2s to produce IL-17A in combination with IL-5 and IL-13, leading to a mixed inflammatory profile and more severe disease. Measurements and Main Results: COPD was characterized by poor spirometry, sputum inflammation, and the emergence of sputum GATA3 + ILCs (ILC2s), but not T-bet + ILCs (ILC1s) nor RORγt + ILCs (ILC3s). COPD subjects with elevated sputum ILC2s (the ILC2 high group) had worse spirometry and sputum neutrophilia and eosinophilia than healthy and ILC2 low subjects. This was associated with the presence of dual-positive IL-5 + IL-17A + and IL-13 + IL-17A + ILCs and nonfunctional SP-D in the sputum in ILC2 high subjects. SP-D -/- mice showed spontaneous airway neutrophilia. Lack of SP-D in the mouse lung licensed ILC2s to produce IL-17A, which was dose-dependently inhibited by recombinant SP-D. SP-D -/- mice showed enhanced susceptibility to O 3 -induced airway neutrophilia, which was associated with the emergence of inflammatory IL-13 + IL-17A + ILCs. Conclusions: We report that the presence of sputum ILC2s predicts the severity of COPD, and unravel a novel pathway of IL-17A plasticity in lung ILC2s, prevented by the immunomodulatory protein SP-D.
RESUMO
Background: Severe coccidioidomycosis presenting with respiratory failure is an uncommon manifestation of disease. Current knowledge of this condition is limited to case reports and small case series. Methods: A retrospective multicenter review of patients with coccidioidomycosis-associated acute respiratory distress syndrome (CA-ARDS) was conducted. It assessed clinical and laboratory variables at the time of presentation, reviewed the treatment course, and compared this cohort with a national database of patients with noncoccidioidomycosis ARDS. Survivors and nonsurvivors of coccidioidomycosis were also compared to determine prognostic factors. Results: In this study, CA-ARDS (n = 54) was most common in males, those of Hispanic ethnicity, and those with concurrent diabetes mellitus. As compared with the PETAL network database (Prevention and Early Treatment of Acute Lung Injury; n = 1006), patients with coccidioidomycosis were younger, had fewer comorbid conditions, and were less acidemic. The 90-day mortality was 15.4% for patients with coccidioidomycosis, as opposed to 42.6% (P < .0001) for patients with noncoccidioidomycosis ARDS. Patients with coccidioidomycosis who died, as compared with those who survived, were older, had higher APACHE II scores (Acute Physiology and Chronic Health Evaluation), and did not receive corticosteroid therapy. Conclusions: CA-ARDS is an uncommon but morbid manifestation of infection. When compared with a national database, the overall mortality appears favorable vs other causes of ARDS. Patients with CA-ARDS had a low overall mortality but required prolonged antifungal therapy. The utility of corticosteroids in this condition remains unconfirmed.
RESUMO
Remote patient monitoring allows monitoring high-risk patients through implementation of an expanding number of technologies in coordination with a healthcare team to augment care, with the potential to provide early detection of exacerbation, prompt access to therapy and clinical services, and ultimately improved patient outcomes and decreased healthcare utilization.In this review, we describe the application of remote patient monitoring in chronic obstructive pulmonary disease including the potential benefits and possible barriers to implementation both for the individual and the healthcare system.
Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/terapia , Monitorização Fisiológica , Atenção à SaúdeRESUMO
Respiratory viral infections are considered a major public health threat, and breath metabolomics can provide new ways to detect and understand how specific viruses affect the human pulmonary system. In this pilot study, we characterized the metabolic composition of human breath for an early diagnosis and differentiation of influenza viral infection, as well as other types of upper respiratory viral infections. We first studied the non-specific effects of planned seasonal influenza vaccines on breath metabolites in healthy subjects after receiving the immunization. We then investigated changes in breath content from hospitalized patients with flu-like symptoms and confirmed upper respiratory viral infection. The exhaled breath was sampled using a custom-made breath condenser, and exhaled breath condensate (EBC) samples were analysed using liquid chromatography coupled to quadruplole-time-of-flight mass spectrometer (LC-qTOF). All metabolomic data was analysed using both targeted and untargeted approaches to detect specific known biomarkers from inflammatory and oxidative stress biomarkers, as well as new molecules associated with specific infections. We were able to find clear differences between breath samples collected before and after flu vaccine administration, together with potential biomarkers that are related to inflammatory processes and oxidative stress. Moreover, we were also able to discriminate samples from patients with flu-related symptoms that were diagnosed with confirmatory respiratory viral panels (RVPs). RVP positive and negative differences were identified, as well as differences between specific viruses defined. These results provide very promising information for the further study of the effect of influenza A and other viruses in human systems by using a simple and non-invasive specimen like breath.
Assuntos
Vacinas contra Influenza , Influenza Humana , Biomarcadores , Testes Respiratórios , Expiração , Humanos , Influenza Humana/diagnóstico , Influenza Humana/prevenção & controle , Projetos Piloto , VacinaçãoRESUMO
Exhaled breath condensate (EBC) is routinely collected and analyzed in breath research. Because it contains aerosol droplets, EBC samples from SARS-CoV-2 infected individuals harbor the virus and pose the threat of infectious exposure. We report for the first time a safe and consistent method to fully inactivate SARS-CoV-2 in EBC samples and make EBC samples safe for processing and analysis. EBC samples containing infectious SARS-CoV-2 were treated with several concentrations of acetonitrile. The most commonly used 10% acetonitrile treatment for EBC processing failed to completely inactivate the virus in samples and viable virus was detected by the assay of SARS-CoV-2 infection of Vero E6 cells in a biosafety level 3 laboratory. Treatment with either 50% or 90% acetonitrile was effective to completely inactivate the virus, resulting in safe, non-infectious EBC samples that can be used for metabolomic analysis. Our study provides SARS-CoV-2 inactivation protocol for the collection and processing of EBC samples in the clinical setting and for advancing to metabolic assessments in health and disease.
Assuntos
COVID-19 , SARS-CoV-2 , Testes Respiratórios , Expiração , Humanos , MetabolômicaRESUMO
Progress in improving patient outcomes and advancing therapeutics in chronic obstructive pulmonary disease (COPD) and idiopathic pulmonary fibrosis (IPF) is hampered by phenotypic heterogeneity and variable responsiveness to clinical interventions that are not fully explained by currently held disease paradigms for COPD and IPF. Although these chronic lung diseases differ in their geoepidemiology and immunopathogenesis, emerging evidence suggest that organ-specific autoimmunity may underlie subphenotypes of COPD and IPF. In particular, the links to tobacco smoking, diet, gender, and environment are explored in this review. We also highlight potential mechanisms that could guide future investigations in both laboratory and clinical settings. A paradigm shift is needed in how we think about COPD and IPF, based on geoepidemiology and a broader understanding of disease pathogenesis that may ultimately lead to new therapies and improved patient outcomes.
Assuntos
Fibrose Pulmonar Idiopática/epidemiologia , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Autoimunidade , Ensaios Clínicos como Assunto , Dieta , Humanos , Fibrose Pulmonar Idiopática/imunologia , Incidência , Especificidade de Órgãos , Prevalência , Doença Pulmonar Obstrutiva Crônica/imunologia , Fatores de Risco , Fatores Sexuais , Fumar/efeitos adversosRESUMO
A wide range of metabolites are measured in the gas phase of exhaled human breath, and some of these biomarkers are frequently observed to be up- or down-regulated in certain disease states. Portable breath analysis systems have the potential for a wide range of applications in health diagnostics. However, this is currently limited by the lack of concentration mechanisms to enhance trace metabolites found in the breath to levels that can be adequately recorded using miniaturized gas-phase sensors. In this study we have created chip-based polymeric pre-concentration devices capable of absorbing and desorbing breath volatiles for subsequent chemical analysis. These devices appear to concentrate chemicals from both environmental air samples as well as directly from exhaled human breath, and these devices may have applications in lab-on-a-chip-based environmental and health monitoring systems.
RESUMO
Exhaled breath condensate (EBC) collection provides a promising matrix for bioanalysis of endogenous biomarkers of health and also for exogenous compounds like drugs. There is little information regarding drugs and their metabolites contained in breath, as well as their pharmacokinetics. In this present work, we use a simple and non-invasive technique to collect EBC from chronic pain patients using different analgesic opioid drugs to manage pain. Six patients received continuous infusion of morphine and hydromorphone intravenously (IV), together with other analgesic drugs (IV and orally). Repeated sampling of serum and EBC was done at two time points separated by 90 min. The EBC was collected using a glass tube surrounded by dry ice, and an ethanol solvent wash of the glass was performed after EBC extraction to retrieve the apolar compounds stuck to the glass surface. All samples were analyzed with liquid chromatography coupled to mass spectrometry (LC-MS/MS) to identify possible metabolites present in the sample, and to quantify the drugs being used. Several metabolites, such as normorphine (norM), norhydromorphone (norHM) and dihydromorphone (diHM) were detected in both fractions, while hydromorphone 3-glucuronide (HM 3G) was only detected in the solvent rinse fraction. Results were correlated to explain the pharmacokinetics of the main drugs administered. This pilot study presented promising correlations between drug concentrations in blood and breath at different time points for norM, norHM and HM 3G.
Assuntos
Analgésicos Opioides/metabolismo , Testes Respiratórios/métodos , Metaboloma , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Masculino , Projetos Piloto , Manejo de Espécimes , Espectrometria de Massas em TandemRESUMO
Portable and wearable medical instruments are poised to play an increasingly important role in health monitoring. Mobile spirometers are available commercially, and are used to monitor patients with advanced lung disease. However, these commercial monitors have a fixed product architecture determined by the manufacturer, and researchers cannot easily experiment with new configurations or add additional novel sensors over time. Spirometry combined with exhaled breath metabolite monitoring has the potential to transform healthcare and improve clinical management strategies. This research provides an updated design and benchmark testing for a flexible, portable, open access architecture to measure lung function, using common Arduino/Android microcontroller technologies. To demonstrate the feasibility and the proof-of-concept of this easily-adaptable platform technology, we had 43 subjects (healthy, and those with lung diseases) perform three spirometry maneuvers using our reconfigurable device and an office-based commercial spirometer. We found that our system compared favorably with the traditional spirometer, with high accuracy and agreement for forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC), and gas measurements were feasible. This provides an adaptable/reconfigurable open access "personalized medicine" platform for researchers and patients, and new chemical sensors and other modular instrumentation can extend the flexibility of the device in the future.
RESUMO
Asthma is a complex inflammatory disease with many triggers. The best understood asthma inflammatory pathways involve signals characterized by peripheral eosinophilia and elevated immunoglobulin E levels (called T2-high or allergic asthma), though other asthma phenotypes exist (eg, T2-low or non-allergic asthma, eosinophilic or neutrophilic-predominant). Common triggers that lead to poor asthma control and exacerbations include respiratory viruses, aeroallergens, house dust, molds, and other organic and inorganic substances. Increasingly recognized non-allergen triggers include tobacco smoke, small particulate matter (eg, PM2.5), and volatile organic compounds. The interaction between respiratory viruses and non-allergen asthma triggers is not well understood, though it is likely a connection exists which may lead to asthma development and/or exacerbations. In this paper we describe common respiratory viruses and non-allergen triggers associated with asthma. In addition, we aim to show the possible interactions, and potential synergy, between viruses and non-allergen triggers. Finally, we introduce a new clinical approach that collects exhaled breath condensates to identify metabolomics associated with viruses and non-allergen triggers that may promote the early management of asthma symptoms.
Assuntos
Alérgenos/imunologia , Asma/imunologia , Asma/virologia , Meio Ambiente , Vírus/imunologia , Poluição do Ar/efeitos adversos , Animais , Humanos , Fumar/efeitos adversosRESUMO
The respiratory system is continuously exposed to variety of biological and chemical irritants that contain reactive oxygen species, and these are well known to cause oxidative stress responses in lung epithelial cells. There is a clinical need to identify biomarkers of oxidative stress which could potentially support early indicators of disease and health management. To identify volatile biomarkers of oxidative stress, we analyzed the headspace above human bronchial epithelial cell cultures (HBE1) before and after hydrogen peroxide (H2O2) and cigarette smoke extract (CSE) exposure. Using stir bar and headspace sorptive extraction-gas chromatography-mass spectrometry, we searched for volatile organic compounds (VOC) of these oxidative measures. In the H2O2 cell peroxidation experiments, four different H2O2 concentrations (0.1, 0.5, 10, 50 mM) were applied to the HBE1 cells, and VOCs were collected every 12 h over the time course of 48 h. In the CSE cell peroxidation experiments, four different smoke extract concentrations (0%, 10%, 30%, 60%) were applied to the cells, and VOCs were collected every 12 h over the time course of 48 h. We used partial-least squares (PLS) analysis to identify putative compounds from the mass spectrometry results that highly correlated with the known applied oxidative stress. We observed chemical emissions from the cells that related to both the intensity of the oxidative stress and followed distinct time courses. Additionally, some of these chemicals are aldehydes, which are thought to be non-invasive indicators of oxidative stress in exhaled human breath. Together, these results illustrate a powerful in situ cell culture model of oxidative stress that can be used to explore the putative biological genesis of exhaled breath biomarkers that are often observed in human clinical studies.
Assuntos
Células Epiteliais/patologia , Peróxido de Hidrogênio/toxicidade , Pulmão/patologia , Metabolômica/métodos , Modelos Biológicos , Estresse Oxidativo , Fumar/efeitos adversos , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Células Epiteliais/efeitos dos fármacos , Humanos , Análise dos Mínimos Quadrados , Estresse Oxidativo/efeitos dos fármacos , Compostos Orgânicos Voláteis/análiseRESUMO
Volatile organic compound (VOC) emissions were measured from Chinese Hamster Ovary (CHO) cell and T cell bioreactor gas exhaust lines with the goal of non-invasively metabolically profiling the expansion process. Measurements of cellular 'breath' were made directly from the gas exhaust lines using polydimethylsiloxane (PDMS)-coated magnetic stir bars, which underwent subsequent thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis. Baseline VOC profiles were observed from bioreactors filled with only liquid media. After inoculation, unique VOC profiles correlated to cell expansion over the course of 8 d. Partial least squares (PLS) regression models were built to predict cell culture density based on VOC profiles of CHO and T cells (R 2 = 0.671 and R 2 = 0.769, respectively, based on a validation data set). T cell runs resulted in 47 compounds relevant to expansion while CHO cell runs resulted in 45 compounds; the 20 most relevant compounds of each cell type were putatively identified. On the final experimental days, sorbent-covered stir bars were placed directly into cell-inoculated media and into media controls. Liquid-based measurements from spent media containing cells could be distinguished from media-only controls, indicating soluble VOCs excreted by the cells during expansion. A PLS-discriminate analysis (PLS-DA) was performed, and 96 compounds differed between T cell-inoculated media and media controls with 72 compounds for CHO cells; the 20 most relevant compounds of each cell line were putatively identified. This work demonstrates that the volatilome of cell cultures can be exploited by chemical detectors in bioreactor gas and liquid waste lines to non-invasively monitor cellular health and could possibly be used to optimize cell expansion conditions 'on-the-fly' with appropriate control loop systems. Although the basis for statistical models included compounds without certain identification, this work provides a foundation for future research of bioreactor emissions. Future studies must move towards identifying relevant compounds for understanding of underlying biochemistry.
Assuntos
Reatores Biológicos , Linfócitos T/metabolismo , Compostos Orgânicos Voláteis/análise , Animais , Células CHO , Proliferação de Células , Cricetinae , Cricetulus , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Análise dos Mínimos Quadrados , Análise de Componente PrincipalRESUMO
The human respiratory tract releases volatile metabolites into exhaled breath that can be utilized for noninvasive health diagnostics. To understand the origin of this metabolic process, our group has previously analyzed the headspace above human epithelial cell cultures using solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS). In the present work, we improve our model by employing sorbent-covered magnetic stir bars for headspace sorptive extraction (HSSE). Sorbent-coated stir bar analyte recovery increased by 52 times and captured 97 more compounds than SPME. Our data show that HSSE is preferred over liquid extraction via stir bar sorptive extraction (SBSE), which failed to distinguish volatiles unique to the cell samples compared against media controls. Two different cellular media were also compared, and we found that Opti-MEM® is preferred for volatile analysis. We optimized HSSE analytical parameters such as extraction time (24â¯h), desorption temperature (300⯰C) and desorption time (7â¯min). Finally, we developed an internal standard for cell culture VOC studies by introducing 842â¯ng of deuterated decane per 5â¯mL of cell medium to account for error from extraction, desorption, chromatography and detection. This improved model will serve as a platform for future metabolic cell culture studies to examine changes in epithelial VOCs caused by perturbations such as viral or bacterial infections, opening opportunities for improved, noninvasive pulmonary diagnostics.
Assuntos
Células Epiteliais/metabolismo , Cromatografia Gasosa-Espectrometria de Massas/métodos , Mucosa Respiratória/citologia , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/isolamento & purificação , Linhagem Celular , Humanos , Microextração em Fase Sólida , Compostos Orgânicos Voláteis/metabolismoRESUMO
The non-invasive, quick, and safe collection of exhaled breath condensate makes it a candidate as a diagnostic matrix in personalized health monitoring devices. The lack of standardization in collection methods and sample analysis is a persistent limitation preventing its practical use. The collection method and hardware design are recognized to significantly affect the metabolomic content of EBC samples, but this has not been systematically studied. Here, we completed a series of experiments to determine the sole effect of collection temperature on the metabolomic content of EBC. Temperature is a likely parameter that can be controlled to standardize among different devices. The study considered six temperature levels covering two physical phases of the sample; liquid and solid. The use of a single device in our study allowed keeping saliva filtering and collector surface effects as constant parameters and the temperature as a controlled variable; the physiological differences were minimized by averaging samples from a group of volunteers and a period of time. After EBC collection, we used an organic solvent rinse to collect the non-water-soluble compounds from the condenser surface. This additional matrix enhanced metabolites recovery, was less dependent on temperature changes, and may possibly serve as an additional pointer to standardize EBC sampling methodologies. The collected EBC samples were analyzed with a set of mass spectrometry methods to provide an overview of the compounds and their concentrations present at each temperature level. The total number of volatile and polar non-volatile compounds slightly increased in each physical phase as the collection temperature was lowered to minimum, 0⯰C for liquid and -30, -56⯰C for solid. The low-polarity non-volatile compounds showed a weak dependence on the collection temperature. The metabolomic content of EBC samples may not be solely dependent on temperature but may be influenced by other phenomena such as greater sample dilution due to condensation from the ambient air at colder temperatures, or due to adhesion properties of the collector surface and occurring chemical reactions. The relative importance of other design parameters such as condenser coating versus temperature requires further investigation.