1.
Ultraschall Med ; 34(4): 382-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23023451

RESUMO

PURPOSE: This study investigates the performance of a 3 D Ultrasound (US) system in imaging elbow and wrist nerves. MATERIALS AND METHODS: Twenty healthy volunteers with asymptomatic median, ulnar and radial nerves were prospectively investigated. Bilateral 3DUS scans of the elbows and wrists were acquired by using a commercially available US scanner (18 MHz, AplioXG, Toshiba) and stored as a 3 D volume by a dedicated software (CURE, Robarts Research Institute). Retrospectively, qualitative (image quality, atypical nerve location, findings potentially associated with compression neuropathy) and quantitative (cross-sectional area measurements) evaluations were performed. RESULTS: In all 200 nerves 3DUS was feasible (100%). Image quality was insufficient in 13.5% (25 ulnar nerve elbow, 2 radial nerve) and sonomorphology was not assessable in those nerves. Measurement of cross sectional areas was feasible in all nerves (100%). Median cross-sectional area (range) were: median nerve elbow 7 mm2 (6-9), radial nerve 3 mm2 (1-4), ulnar nerve elbow 8 mm2 (5-11), median nerve wrist 8 mm2 (5-10), and ulnar nerve wrist 4 mm2 (2-6). No significant changes in nerve cross-sectional area along each nerve was found. Ulnar nerve subluxation was found in 2 nerves (6.7%). No anconeus epitrochlearis muscle or osteophytes were found. CONCLUSION: 3DUS is a feasible method for assessing nerves of the upper extremity and has been shown to provide a good overview of the median, ulnar and radial nerve at the elbow and wrist, but is limited for evaluation of the ulnar nerve in the cubital tunnel. This technique enables reliable measurements at different locations along the nerve.


Assuntos
Braço/inervação , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Nervo Mediano/diagnóstico por imagem , Nervo Radial/diagnóstico por imagem , Nervo Ulnar/diagnóstico por imagem , Ultrassonografia/métodos , Cotovelo/diagnóstico por imagem , Cotovelo/inervação , Estudos de Viabilidade , Humanos , Posicionamento do Paciente , Valores de Referência , Sensibilidade e Especificidade , Punho/diagnóstico por imagem , Punho/inervação
2.
Ultrasonics ; 36(1-5): 629-33, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9651592

RESUMO

With conventional ultrasonography, the diagnostician must view a series of two-dimensional images in order to form a mental impression of the three-dimensional anatomy, an efficient and time consuming practice prone to operator variability, which may cause variable or even incorrect diagnoses. Also, a conventional two-dimensional ultrasound image represents a thin slice of the patients anatomy at a single location and orientation, which is difficult to reproduce at a later time. These factors make conventional ultrasonography non-optimal for prospective or follow-up studies. Our efforts have focused on overcoming these deficiencies by developing three-dimensional ultrasound imaging techniques that are capable of acquiring B-mode, colour Doppler and power Doppler images of the vasculature, by using a conventional ultrasound system to acquire a series of two-dimensional images and then mathematically reconstructing them into a single three-dimensional image, which may then be viewed interactively on an inexpensive desktop computer. We report here on two approaches: (1) free-hand scanning, in which a magnetic positioning device is attached to the ultrasound transducer to record the position and orientation of each two-dimensional image needed for the three-dimensional image reconstruction; and (2) mechanical scanning, in which a motor-driven assembly is used to translate the transducer linearly across the neck, yielding a set of uniformly-spaced parallel two-dimensional images.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção , Algoritmos , Desenho de Equipamento , Seguimentos , Humanos , Magnetismo , Microcomputadores , Estudos Prospectivos , Transdutores , Ultrassonografia Doppler , Ultrassonografia Doppler em Cores