1.
Surg Endosc ; 38(4): 1731-1739, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38418634

RESUMO

BACKGROUND: Female sex has been associated with worse outcomes after groin hernia repair (GHR), including a higher rate of chronic pain and recurrence. Most of the studies in GHR are performed in males, and the recommendations for females extrapolate from these studies, even though females have anatomy intricacies. The round ligament of the uterus (RLU) is associated with pelvic stabilization and plays a role in sensory function. Transection of the RLU during GHR is controversial as it can allow easier mesh placement but can favor genitourinary complications and chronic pain. As no previous meta-analysis compared preserving versus transecting the RLU during minimally invasive (MIS) GHR, we aim to perform a systematic review and meta-analysis evaluating surgical outcomes comparing the approaches. METHODS: Cochrane Central, Embase, and PubMed databases were systematically searched for studies comparing transection versus preservation of the RLU in MIS groin hernia surgeries. Outcomes assessed were operative time, bleeding, surgical site events, hospital stay, chronic pain, paresthesia, recurrence rates, and genital prolapse rates. Statistical analysis was performed using RevMan 5.4.1. Heterogeneity was assessed with I2 statistics. A review protocol for this meta-analysis was registered at PROSPERO (CRD 42023467146). RESULTS: 1738 studies were screened. A total of six studies, comprising 1131 women, were included, of whom 652 (57.6%) had preservation of the RLU during MIS groin hernia repair. We found no statistical difference regarding chronic pain, paresthesia, recurrence rates, and postoperative complications. We found a longer operative time for the preservation group (MD 6.84 min; 95% CI 3.0-10.68; P = 0.0005; I2 = 74%). CONCLUSION: Transecting the RLU reduces the operative time during MIS GHR with no difference regarding postoperative complication rates. Although transection appears safe, further prospective randomized studies with long-term follow-up and patient-reported outcomes are necessary to define the optimal management of RLU during MIS GHR.


Assuntos
Dor Crônica , Hérnia Inguinal , Laparoscopia , Ligamentos Redondos , Masculino , Humanos , Feminino , Dor Crônica/etiologia , Dor Crônica/cirurgia , Virilha/cirurgia , Herniorrafia/métodos , Parestesia/complicações , Parestesia/cirurgia , Telas Cirúrgicas/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Hérnia Inguinal/cirurgia , Hérnia Inguinal/complicações , Ligamentos Redondos/cirurgia , Dor Pós-Operatória/etiologia , Recidiva , Laparoscopia/métodos
2.
Hernia ; 27(6): 1375-1385, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37715825

RESUMO

PURPOSE: We aimed to perform a systematic review and meta-analysis comparing postoperative outcomes in inguinal hernia repair with TIPP versus Lichtenstein technique. METHODS: Cochrane Central, Scopus, and PubMed were systematically searched for studies comparing TIPP and Lichtenstein´s technique for inguinal hernia repair. Outcomes assessed were operative time, bleeding, surgical site events, hospital stay, the Visual Analogue Pain Score, chronic pain, paresthesia rates, and recurrence. Statistical analysis was performed using RevMan 5.4.1. Heterogeneity was assessed with I2 statistics and random-risk effect was used if I2 > 25%. RESULTS: 790 studies were screened and 44 were thoroughly reviewed. A total of nine studies, comprising 8428 patients were included, of whom 4185 (49.7%) received TIPP and 4243 (50.3%) received Lichtenstein. We found that TIPP presented less chronic pain (OR 0.43; 95% CI 0.20-0.93 P = 0.03; I2 = 84%) and paresthesia rates (OR 0.27; 95% CI 0.07-0.99; P = 0.05; I2 = 63%) than Lichtenstein group. In addition, TIPP was associated with a lower VAS pain score at 14 postoperative day (MD - 0.93; 95% CI - 1.48 to - 0.39; P = 0.0007; I2 = 99%). The data showed a lower operative time with the TIPP technique (MD - 7.18; 95% CI - 12.50, - 1.87; P = 0.008; I2 = 94%). We found no statistical difference between groups regarding the other outcomes analyzed. CONCLUSION: TIPP may be a valuable technique for inguinal hernias. It was associated with lower chronic pain, and paresthesia when compared to Lichtenstein technique. Further long-term randomized studies are necessary to confirm our findings. Study registration A review protocol for this meta-analysis was registered at PROSPERO (CRD42023434909).


Assuntos
Dor Crônica , Hérnia Inguinal , Humanos , Dor Crônica/etiologia , Dor Crônica/cirurgia , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/cirurgia , Hérnia Inguinal/cirurgia , Parestesia/cirurgia , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Telas Cirúrgicas , Recidiva , Resultado do Tratamento
3.
Rev Sci Instrum ; 85(8): 083505, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25173267

RESUMO

This work aimed the obtainment of a neutral atomic jet departing from a plume generated by laser ablation of copper targets. A pair of electrodes together with a transducer pressure sensor was used to study the ablated plume charge composition and also to measure the ion extraction from the plasma plume. The neutral beam was produced with this setup and the relative abundance of neutrals in the plasma was measured, it decreases from 30% to 8% when the laser fluence is varied from 20 J/cm(2) to 32 J/cm(2). The necessary voltage to completely remove the ions from the plume varied from 10 V to 230 V in the same fluence range. TOF analysis resulted in center of mass velocities between 3.4 and 4.6 km/s, longitudinal temperature in the range from 1 × 10(4) K to 2.4 × 10(4) K and a Mach number of M = 2.36, calculated using purely hydrodynamic expansion approximation.