Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Int J Obes (Lond) ; 44(5): 990-998, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31949295

RESUMO

BACKGROUND: A WW (formerly Weight Watchers) program adapted for persons with type 2 diabetes mellitus (T2DM) previously was found to be more effective than standard care (SC) intervention for weight loss, improved glycemic control, and weight- and diabetes-related quality of life measures. With data from the same national trial, this study examined whether WW adapted for persons with T2DM also increased engagement in weight control behaviors and decreased hedonic hunger, each of which could contribute to improved diabetes management. INTERVENTION AND METHODS: Individuals with T2DM (n = 563) and overweight or obesity participated in a 12-month, 16-site, randomized trial of WW with diabetes counseling or SC. Hierarchical linear modeling (HLM) evaluated whether 12-month changes in weight control behaviors (Eating Behavior Inventory; EBI) and hedonic hunger (Power of Food Scale; PFS) differed by treatment condition. If a significant treatment effect was found, 12-month changes in EBI/PFS were regressed on 12-month changes in HbA1c and percent weight loss to explore potential treatment differences in these associations. RESULTS: EBI scores increased significantly over the 12-months (p < 0.001), with greater improvements in WW than SC (p < 0.001). PFS decreased significantly in the 12-months (p < 0.001), with no differences between treatment groups (p = 0.15). HLM analyses that followed up on the significant treatment effect for 12-month change in EBI revealed no significant differences by treatment condition for the relationship between change in EBI scores and change in HbA1c (p = 0.14) or percent weight loss (p = 0.32). Across all participants, 12-month improvements in EBI and PFS were related to improved HbA1c (r = 0.22; -0.13, respectively) and greater percent weight loss (r = 0.41; -0.18, respectively) (ps < 0.01). CONCLUSIONS: WW with diabetes counseling produced greater engagement in weight control behaviors in those with T2DM than did SC. Across both groups, improved weight control behaviors and hedonic hunger were related to improved glycemic control and weight loss.


Assuntos
Diabetes Mellitus Tipo 2/terapia , Fome/fisiologia , Obesidade/terapia , Redução de Peso/fisiologia , Programas de Redução de Peso/métodos , Adulto , Idoso , Peso Corporal/fisiologia , Feminino , Hemoglobinas Glicadas/análise , Comportamentos Relacionados com a Saúde/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Sobrepeso/terapia , Estudos Prospectivos
2.
Catheter Cardiovasc Interv ; 93(1): 120-127, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30079565

RESUMO

OBJECTIVE: To investigate the effect of left atrial appendage (LAA) occlusion device positioning upon periprocedural and long-term outcomes. BACKGROUND: The Amulet device is designed to cover the ostium of the LAA. Prolapse of the device into the neck of the LAA is not uncommon resulting in incomplete coverage of the ostium. The clinical consequences of this remain uncertain. METHODS: Outcomes of 87 patients with successful LAA closure were analyzed according to Amulet disc position: group A (n = 45) had complete LAA ostium coverage; group B (n = 42) had incomplete ostium coverage because of disc prolapse. Periprocedural major adverse events (MAE) (composite of all cause death, tamponade, device/air embolization, cerebrovascular events, myocardial infarction, and major bleeding not related to vascular access complications) and total device-related periprocedural adverse events (defined as MAE and pericardial effusion) were evaluated. All patients were followed up longitudinally with long-term events defined as a composite of: cardiovascular death, cerebrovascular events, systemic embolization, and major bleeding requiring transfusion or intervention. RESULTS: Median follow-up was 234 days (IQR 150-436 days). There was a trend toward more periprocedural MAE in group B (P = 0.07) with deep implantation of the Amulet device associated with significantly more periprocedural adverse events (P = 0.03). There were no differences in reposition attempts (P = 0.9) or long-term events (P = 0.57). CONCLUSIONS: Our data suggest that suboptimal device positioning may be associated with worse periprocedural outcomes but no difference in long-term clinical outcomes. The results of this relatively small cohort does not seem to be affected by repositioning attempts during the index procedure.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Frequência Cardíaca , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
3.
Europace ; 20(5): 829-834, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339758

RESUMO

Aims: The aim of this prospective multicentre study is to evaluate safety and efficacy of the new bidirectional rotational mechanical lead extraction (LE) sheath (Evolution RL, Cook Medical, USA) in chronically implanted leads (>1-year-old leads). Methods and results: Between September 2013 and June 2016, a total of 238 leads in 124 consecutive patients were removed by using the new Evolution RL rotational mechanical sheath. Indications for LE were cardiac device infection in 63 (50.8%) cases, lead malfunction in 41 (33.1%), upgrade in 1 (0.8%) case and for other reasons in the remaining 19 cases (15.3%). Ninety-one leads (38.2%) were implantable cardioverter defibrillator leads (81 dual coil vs. 10 single coil), 38 (16%) right ventricular leads, 86 (36.1%) right atrial leads, and 23 (9.7%) coronary sinus leads. The mean implant duration was 92.2 ± 52.9 months (range 12-336). 91.6% of the leads (218/238) were extracted completely with the Evolution RL alone, with the complete success rate rising to 98.7% (235/238 leads) with combined use of a snare. Overall clinical success rate was 100%. No Evolution sheath-related complications were noted. There were no deaths or major complications. Five minor complications (4%) were encountered. In cases of companion leads no wrapping or lead damage were observed. Conclusion: On the basis of our prospective multicentre study, the new hand-powered bidirectional rotational mechanical LE sheath is an effective and safe tool for the extraction of chronically implanted leads without major complications and lead wrapping or lead damage.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 89(4): 763-772, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27567013

RESUMO

OBJECTIVES: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. BACKGROUND: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. METHODS: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. RESULTS: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 6-26 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks ≥1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. CONCLUSIONS: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Cirurgia Assistida por Computador/métodos , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Desenho de Prótese , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 26(5): 532-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25598359

RESUMO

INTRODUCTION: In patients with a prior myocardial infarction (MI), angiographic predictors of ventricular tachycardia (VT) recurrence after ablation are lacking. Recently, a proarrhythmic effect of a chronic total occlusion (CTO) in a coronary artery has been suggested. METHODS AND RESULTS: A total of 191 patients with prior MI were referred to our Hospital between 2010 and June 2013 for a first ablation of VT. Of these, 84 patients (44%) with stable coronary artery disease that underwent a coronary angiography during the index hospitalization were included in this study. A CTO in an infarct-related artery (IRA-CTO) was present in 47 patients (56%). Patients with and without IRA-CTO did not differ in terms of comorbidities, severity of heart failure, presentation of VT or acute outcome of ablation, that was completely successful in 93% of cases. At electroanatomic mapping, IRA-CTO was associated with greater scar and especially with greater area of border zone (34 cm(2) vs. 19 cm(2) , P = 0.001). Median follow-up was 19 months (IQR 18). At follow-up, patients with IRA-CTO had a significantly higher rate of VT recurrence (47% vs. 16%, P = 0.003). At multivariate analysis, IRA-CTO resulted to be an independent predictor of VT recurrence after ablation (HR 4.05, P = 0.004). CONCLUSIONS: IRA-CTO is an independent predictor of VT recurrence after ablation and identifies a subgroup of patients with high recurrence rate despite a successful procedure. IRA-CTO is associated with greater scars and border zone area; however, this association does not completely justify its proarrhythmic effect.


Assuntos
Ablação por Cateter , Oclusão Coronária/complicações , Infarto do Miocárdio/etiologia , Taquicardia Ventricular/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Doença Crônica , Comorbidade , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Espanha , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento
6.
Europace ; 15(12): 1771-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23645529

RESUMO

AIM: The evolution mechanical dilator sheath has been reported to be an effective tool for chronic lead extraction (LE). We examined safety and efficacy of evolution system as compared with laser system. METHODS AND RESULTS: From 2005 to 2009, all extractions requiring the use of a powered sheath were performed using the excimer laser system (n = 73). Since 2009, laser system was no longer available and the evolution system was introduced as the first-line method for powered extraction (n = 48). All procedures were performed by a single first operator. Success and complications were defined according to the current guidelines. Patients of the evolution group compared with those of the laser group had a greater number of extracted leads per patient (2.77 vs. 2.4, P = 0.049) and a longer implant duration (101.1 vs. 62.4 months, P = 0.001). Additional use of snare was required in 27.1% of the evolution group and 8.2% of the laser group (P = 0.005). Complete procedural success was achieved in 91.7% of the evolution group and 97.3% of the laser group (P = 0.16). There was also no difference between evolution and laser groups in clinical success (97.9 vs. 98.6%, P = 0.76), as well as regarding major (4.2 vs. 2.7%, P = 0.66) or minor complications (4.2 vs. 5.5%, P = 0.76). CONCLUSION: Use of the recently introduced evolution system for LE exhibit acceptably high levels of safety, as well as of procedural and clinical success, although additional use of snare was required more frequently in the evolution compared with the laser group.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Dilatação , Terapia a Laser , Marca-Passo Artificial , Idoso , Cateteres Cardíacos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Dilatação/efeitos adversos , Dilatação/instrumentação , Desenho de Equipamento , Feminino , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Lasers de Excimer , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 36(7): 837-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23510021

RESUMO

BACKGROUND: Lead extraction (LE) techniques have evolved from simple traction to extraction with dilators and powered sheaths with very high success rates. On the basis of the systematic implementation of a stepwise approach, we aimed to identify those characteristics that can predict the need for advanced LE techniques. METHODS: Between April 2005 and March 2012, 208 consecutive LE procedures were performed and 456 leads were extracted using an initial superior approach. Advanced techniques for LE (step 4 according to our stepwise approach) were used in 122 patients (58.7%). RESULTS: Younger patient age (odds ratio [OR] = 0.963, P = 0.002), longer duration of the initial implantation (OR = 1.013, P = 0.002), the number of extracted leads (OR = 2.184, P < 0.001), and the presence of right ventricular defibrillator leads (OR = 2.144, P = 0.049) independently predicted the necessity of using step 4 in multivariate analysis. A prediction tool was created taking into account four categorical variables derived even from Receiver Operating Curve analysis of quantitative characteristics (age < 70.7 years, implant duration > 37 months, extraction of at least two leads, one of them being a defibrillator lead). The absence of all the four characteristics was accompanied by 0% positive predictive value for the requirement of step 4 for LE, whereas the coexistence of all four risk factors is characterized by 87% requirement of advanced LE. CONCLUSION: In most of the patients with indication for LE, use of a powered sheath extraction is necessary in order to obtain clinical success. We have identified four patient and lead characteristics that may help the operator plan the means of extraction.


Assuntos
Algoritmos , Remoção de Dispositivo/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Cardiopatias/epidemiologia , Cardiopatias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/instrumentação , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Resultado do Tratamento , Adulto Jovem
8.
J Clin Periodontol ; 40(6): 599-606, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23557538

RESUMO

AIM: To assess associations of metabolic syndrome, and its individual components, with extent of severe periodontitis among patients with type 2 diabetes mellitus (T2DM). MATERIALS & METHODS: We performed a secondary data analysis (N = 283) using a cross-sectional study population of Gullah African Americans with T2DM. Extent of severe periodontitis was assessed as total diseased tooth-sites/person [evaluated as separate outcomes: 6+mm clinical attachment level (CAL), 5+mm periodontal probing depth (PPD)] using negative binomial regression techniques. Primary independent variables assessed in separate models included metabolic syndrome (yes/no), each metabolic syndrome component (low HDL, hypertension, high triglycerides, large waist circumference) and glycemic control (poor/good). RESULTS: Multivariable CAL-model results showed a significant association for metabolic syndrome status with extent of severe periodontitis (RR = 2.77, p = 0.03). The separate multivariable CAL-model including each metabolic syndrome component showed marginally increased rates among those with large waist circumference (RR = 2.33, p = 0.09) and those with HbA1c ≥ 7% (RR = 1.73, p = 0.06). Multivariable PPD-models showed marginally increased rates among those with metabolic syndrome (RR = 2.18, p = 0.06). CONCLUSION: Metabolic syndrome is associated with the extent of severe periodontitis in this Gullah population with T2DM.


Assuntos
Negro ou Afro-Americano , Periodontite Crônica/complicações , Diabetes Mellitus Tipo 2/complicações , Síndrome Metabólica/complicações , Síndrome Metabólica/etnologia , Adulto , Idoso , Periodontite Crônica/etnologia , Estudos Transversais , Diabetes Mellitus Tipo 2/etnologia , Feminino , Humanos , Hipertensão/complicações , Hipertrigliceridemia/complicações , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/etnologia , Análise de Regressão , Fatores de Risco , Estados Unidos
9.
Curr Treat Options Oncol ; 13(1): 47-57, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22234582

RESUMO

OPINION STATEMENT: Well differentiated thyroid carcinoma (WDTC) is a relatively common malignancy accounting for an estimated 37,000 thousand cases in the United States in 2009 [1]. WDTC also has a generally high 5 year survival rate that correlates with age. Papillary thyroid carcinoma (PTC) greater than 1 cm is best managed by total thyroidectomy. Thyroid lobectomy and isthmusectomy may be adequate for unifocal PTC less than 1 cm in patients without negative prognostic factors. Central compartment and possible lateral neck dissections should be performed when nodal metastases are present in the respective nodal basins. Post-operatively, radioactive iodine ablation with (131)I followed by thyroid stimulating hormone (TSH) suppression is indicated in certain patients to improve locoregional control and reduce recurrence.


Assuntos
Radioisótopos do Iodo/uso terapêutico , Esvaziamento Cervical , Neoplasias da Glândula Tireoide/terapia , Tireoidectomia , Tiroxina/uso terapêutico , Carcinoma , Carcinoma Papilar , Feminino , Humanos , Metástase Linfática , Masculino , Esvaziamento Cervical/métodos , Prognóstico , Taxa de Sobrevida , Câncer Papilífero da Tireoide , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/epidemiologia , Tireoidectomia/métodos , Estados Unidos/epidemiologia
10.
Am J Pathol ; 177(1): 197-207, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20489145

RESUMO

There is little known about healing of the uterus after Cesarean delivery (CD). Uterine wound repair was studied by using two strains of mice with different wound healing characteristics: MRL/MpJ(+/+) (MRL: "high-healer" phenotype) and C57Bl/6 ("low-healer" phenotype). First, we examined the morphology and histology of the uterine wall repair. We identified wound granulation tissue 3 days post-CD in both strains, albeit less in the MRL strain. Macroscopically, no scar could be identified either in MRL or C57Bl/6 mice on day 60 post-CD. However, histologically, we found significant differences in wound integration, inflammation, and collagen birefringence between the two strains of mice. Using a histological index, we provided evidence for significant differences in mitotic activity in the initial phases of uterine healing among strains. Functional behavior of the uterine scar also was analyzed by using biomechanical parameters such as slope (measure of stiffness), yield point (measure of elasticity), and break point (measure of strength). There were significant differences in stiffness of the scarred myometrium between the two phenotypes. MRL mice displayed a significantly lower yield point compared with C57Bl/6. The break point was reached faster on days 15 and 60 in both C57Bl/6 and MRL strains compared with day 3 post-CD. Our findings indicate that differences in regenerative ability translate in histological, mitotic, and functional differences in biomechanical properties of the scarred myometrium after CD.


Assuntos
Cesárea/efeitos adversos , Cicatriz/patologia , Miométrio/patologia , Miométrio/fisiologia , Útero/patologia , Cicatrização/fisiologia , Animais , Orelha/patologia , Feminino , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos , Miométrio/anatomia & histologia , Gravidez , Regeneração/fisiologia , Resistência à Tração , Útero/anatomia & histologia , Útero/fisiologia
11.
J Interv Card Electrophysiol ; 60(1): 85-92, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32060817

RESUMO

PURPOSE: There is still sparse information regarding phrenic nerve palsy (PNP) during the cryoablation of both right-sided pulmonary vein (PV) and its anatomical predictors. METHODS: Consecutive patients who had undergone pulmonary vein isolation (PVI) using CB-A and suffered PNP during both right-sided PVs were retrospectively included in our study. Two other groups were then selected among patients who experienced PNP during RIPV application only (group 2) and RSPV application only (group 3). RESULTS: The incidence of PNI during both right-sided PVs cryoapplications was 2.1%, (32 of 1542 patients). There were no significant clinical differences between the 3 groups. Time from basal temperature to -40 °C significantly differed among the groups for both RIPV (p = 0.0026) and RSPV applications (p = 0.0382). Patients with PNP occurring during RSPV applications had significantly larger RSPV cross-sectional area compared to patients without PNP (p = 0.0116), while in patients with PNP during RIPV application, the angle of RIPV ostium on the transverse plane was significantly smaller compared to patients without PNP (p = 0.0035). The carina width was significantly smaller in patients with PNP occurring during both right-sided PVs cryoapplications compared to patients in which PNP occurred only during one right-sided PV application (p < 0.0001); a cutoff value of 8.5 mm had a sensitivity of 87.3% and a specificity of 75.0%. CONCLUSION: PNP in both right-sided PVs applications is a complication that occurred in 2.1% of cases during CB-A. Pre-procedural evaluation of right PVs anatomy might be useful in evaluating the risk of PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Nervo Frênico , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Paralisia/etiologia , Nervo Frênico/lesões , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
12.
Am J Obstet Gynecol ; 200(4): 434.e1-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19200937

RESUMO

OBJECTIVE: We hypothesized that the genetic makeup has an impact on the functional behavior of the uterine cervix. Therefore, we compared the biomechanical properties of uterine cervix in postpartum in 2 strains of mice that differ in their underlying regenerative collagen remodeling characteristics: MRL/MpJ+/+ (MRL: high regenerative repair) and C57BL/6 (C57: low regenerative high fibrotic repair). STUDY DESIGN: Cervical tensile proprieties were assessed on day 3, 15, and 60 postpartum in MRL (n = 14) and C57 (n = 13) mice (4-5 animals at each time point). Stress-strain curves were generated using Shimadzu EZ-test instrumentation. Cervical tissue was stretched by 0.42 mm/min until rupture. Parameters of viscoelasticity including slope (a measure of stiffness), yield point (YP; moment when tissue changes its proprieties from elastic to plastic), and break point (BP; measure of tissue strength) were recorded and analyzed blindly between strains. Data were normalized to the weight of the tissue and analyzed by 2-way analysis of variance. Histological and collagen birefringence evaluation of the uterine cervix (MRL: n = 4; C57: n = 4) was performed 5 days after delivery. RESULTS: At 3 and 15 days postpartum, cervices of MRL mice were significantly more compliant than those of C57 (P < .001). MRL mice displayed a significant increase in stiffness from day 3 to day 60 (slope, median +/- SEM: day 3: 3.1 +/- 0.5 vs day 15: 20.3 +/- 4.9 vs day 60: 33.1 +/- 3.5 N/mm per gram; P < .001). In contrast, the stiffness of C57 cervices reached maximum on day 15 (slope day 3: 14.1 +/- 4.3 vs day 15: 40.0 +/- 6.5 N/mm per gram; P = .02) and rested at a similar level on day 60 (day 60: 26.1 +/- 7.0 N/mm per gram; day 60 vs day 15: P = .937). More force was required to reach YP in C57 on day 3 (C57: 72.5 +/- 14.7 vs MRL: 19.9 +/- 1.6 N/g; P < .001) but not on either day 15 (C57: 156.1 +/- 27.5 vs MRL: 109.2 +/- 26.0 N/g; P = .120) or on day 60 (C57: 143.4 +/- 26.5 vs MRL: 164.5 +/- 18.7 N/g; P = .412). There was a significant decrease in BP in both strains on both day 15 and day 60 compared with day 3 postpartum (P = .856 for strain, P = .008 for day). MRL mice displayed significantly less cervical collagen birefringence compared with C57 control (P < .001) but increased proteoglycan staining and increased water content. CONCLUSION: We provide evidence that genetic makeup may have an impact on cervical tissue remodeling and function. There are significant differences in postpartum cervical stiffness and compliance that vary with the regenerative collagen remodeling phenotype.


Assuntos
Fenômenos Biomecânicos/genética , Colo do Útero/fisiologia , Período Pós-Parto/genética , Animais , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Fatores de Tempo
13.
Am J Med Sci ; 358(5): 326-331, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31655714

RESUMO

Insulin pump therapy, also known as continuous subcutaneous insulin infusion (CSII) therapy is an evolving form of insulin delivery which has been shown to be highly effective in maintaining euglycemia and providing patients with flexibility in their lives. It functions by providing the patient with a continuous subcutaneous infusion of a rapid acting insulin and allows the patient to administer boluses throughout the day for food and correction of high glucose levels. CSII is approved in patients with type 1 diabetes and selected patients with type 2 diabetes; however, it is important to select the right patients for pump therapy. Insulin pump technology continues to rapidly evolve, and many options are now on the market, including those that are used in conjunction with continuous glucose monitoring. This review article focuses on the pros and cons of CSII therapy as well as the technical and clinical considerations in starting a patient on this therapy.


Assuntos
Glicemia/análise , Diabetes Mellitus , Bombas de Infusão Implantáveis , Insulina/administração & dosagem , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Humanos , Hipoglicemiantes/administração & dosagem , Invenções , Administração dos Cuidados ao Paciente/métodos , Administração dos Cuidados ao Paciente/tendências , Seleção de Pacientes
14.
J Diabetes Complications ; 31(5): 891-897, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28319001

RESUMO

AIMS: Type 2 diabetes mellitus (T2DM) can substantially decrease quality of life (QOL). This study examined the effects on QOL-relevant psychosocial measures of a widely available commercial weight loss program enhanced for individuals with T2DM. METHODS: A year-long multi-site randomized clinical trial compared the Weight Watchers (WW) approach, supplemented with phone and email counseling with a certified diabetes educator (CDE), to brief standard diabetes nutrition counseling and education (Standard Care; SC). Participants were 400 women and 163 men (N=279 WW; 284 SC) with T2DM [mean (±SD) HbA1c 8.32±1%; BMI=37.1±5.7kg/m2; age=55.1 ± 9.1years]. Psychosocial outcomes were assessed at baseline, month 6, and month 12 using a diabetes specific psychosocial measure (Diabetes Distress Scale [DDS]), Impact of Weight on Quality of Life-Lite scale (IWQOL), a generic QOL measure (SF-36), and a depression screen (PHQ-9). RESULTS: WW participants showed significantly greater improvements than did SC participants on all DDS subscales and total score and on IWQOL total score and physical function, sex life and work domains (all ps<.05). There was no significant treatment effect on SF-36 scores or PHQ-9. CONCLUSIONS: WW enhanced for individuals with T2DM was superior to SC in improving psychosocial outcomes most specific to T2DM and obesity. Available commercial WL programs, combined with scalable complementary program-specific diabetes counseling, may have benefits that extend to diabetes-related distress and weight-relevant QOL.


Assuntos
Diabetes Mellitus Tipo 2/terapia , Obesidade/terapia , Sobrepeso/terapia , Sistemas de Apoio Psicossocial , Qualidade de Vida , Telemedicina , Programas de Redução de Peso , Adolescente , Adulto , Idoso , Índice de Massa Corporal , Terapia Combinada , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/psicologia , Correio Eletrônico , Feminino , Humanos , Hiperglicemia/prevenção & controle , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/psicologia , Obesidade Mórbida/complicações , Obesidade Mórbida/psicologia , Obesidade Mórbida/terapia , Sobrepeso/complicações , Sobrepeso/psicologia , Educação de Pacientes como Assunto , Telefone , Estados Unidos , Redução de Peso , Adulto Jovem
15.
J Am Coll Cardiol ; 45(6): 868-72, 2005 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15766822

RESUMO

OBJECTIVES: Few data have been published on transcatheter ablation of atrial fibrillation (AF) in patients with mitral valve prostheses. Thus, we sought to report our experience. BACKGROUND: Ablation is an effective treatment for AF. Patients with prosthetic mitral valves represent a special group because of an increased risk from the ablation procedure due to the possibility of damage to the prosthetic valve. METHODS: Between July 2001 and July 2003, 26 patients with mitral valve prostheses (MVP) underwent circumferential pulmonary vein ablation for AF. A matched group of 52 ablated patients without MVP acted as control subjects. After a blanking period of three months, a follow-up of 12 months was considered for MVP patients and controls. Holter recordings were performed in all subjects at 3, 6, and 12 months. RESULTS: Radiation exposure was higher in the MVP group, with fluoroscopy times of 35.3 +/- 21 min versus 20.9 +/- 15 min in controls. At the end of follow-up, 73% of MVP patients were in sinus rhythm, compared with 75% of controls. Atrial tachycardia occurred in six (23%) MVP patients, requiring repeat ablation in three, and one (2%) control subject, which settled without treatment. One transient ischemic attack and one femoral pseudoaneurysm occurred in the MVP group. No complications occurred in the control group. CONCLUSIONS: Ablation of AF in patients with MVP is feasible, with outcomes similar to those of standard patients. Complications were higher among MVP patients with a greater radiation exposure and a higher incidence of post-ablation atrial tachycardia.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Próteses Valvulares Cardíacas , Prolapso da Valva Mitral/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/mortalidade , Intervalo Livre de Doença , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/tratamento farmacológico , Prolapso da Valva Mitral/mortalidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Recidiva , Taquicardia Atrial Ectópica/etiologia , Taquicardia Atrial Ectópica/mortalidade , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 17(12): 1279-85, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17081209

RESUMO

INTRODUCTION: There is limited information describing late changes in the electroanatomic characteristics of the left atrium (LA) associated with recurrence after an anatomical circumferential pulmonary vein ablation (CPVA) for atrial fibrillation (AF). METHODS AND RESULTS: Forty-seven patients (57 +/- 8 years) undergoing a repeat ablation after CPVA were included. Using an electroanatomic mapping system, we measured the bipolar voltage by averaging points in the pulmonary vein (PV)-LA junction and four other LA sites. Conduction velocity and AF cycle length (AFCL) were also measured and the results are compared with the first procedure. After an initial decrease observed at the end of the first procedure, voltage and conduction velocity returned to intermediate values in all LA sites, with lower voltage at the LIPV antrum (P = 0.004), and lower conduction velocity across the LIPV and RSPV (P < 0.001). Conduction gaps were more prevalent at the septal aspect of the right PV encircling lines (85%), between the left atrial appendage (LAA) and the LSPV (70%) and lines at the posterior wall (71%). There was a nonsignificant increase in AFCL, with a more widespread distribution of organized electrograms (32.4% vs 46.6%). CONCLUSION: Recurrence after CPVA is associated with a reverse process of voltage and conduction velocity increase across ablated areas, especially the PV-LA junction, and is related to the presence of conduction gaps, which are distributed mostly at the septal aspect of the lines encircling the right PVs and at the LAA-LSPV area. Organization of atrial electrograms seen during AF ablation is maintained at a repeat procedure.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Ablação por Cateter , Feminino , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Reoperação , Resultado do Tratamento
17.
Am J Med Sci ; 351(4): 361-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27079341

RESUMO

BACKGROUND: Cardiovascular disease is the most common cause of morbidity and mortality in patients with diabetes and the major source of cost in the care of diabetes. Treatment of dyslipidemia with cholesterol-lowering medications has been shown to decrease cardiovascular events. However, available guidelines for the treatment of dyslipidemia often contain significant differences in their recommendations. METHODS: Lipid guidelines from National Cholesterol Education Program Adult Treatment Panel III, American Association of Clinical Endocrinologists, American Diabetes Association and American Heart Association/American College of Cardiology were reviewed. In addition a literature review was performed using PubMed to research diabetic peculiarities to the topic of lipids. RESULTS: Summarized within this article are the aforementioned, commonly-used guidelines as they relate to diabetes, as well as information regarding the diabetic phenotype of dislipidemia and the association between statins and new-onset diabetes. CONCLUSIONS: While the multitude of guidelines and the differences between them may contribute to confusion for practitioners, they are best viewed as tools to help tailor appropriate treatment plans for individual patients.


Assuntos
Diabetes Mellitus/epidemiologia , Diabetes Mellitus/terapia , Gerenciamento Clínico , Dislipidemias/epidemiologia , Dislipidemias/terapia , Guias de Prática Clínica como Assunto/normas , Anticolesterolemiantes/uso terapêutico , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Diabetes Mellitus/diagnóstico , Dislipidemias/diagnóstico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipolipemiantes/uso terapêutico , Fatores de Risco
18.
19.
Obesity (Silver Spring) ; 24(11): 2269-2277, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27804264

RESUMO

OBJECTIVE: Modest weight loss from clinical interventions improves glycemic control in type 2 diabetes (T2DM). Data are sparse on the effects of weight loss via commercial weight loss programs. This study examined the effects on glycemic control and weight loss of the standard Weight Watchers program, combined with telephone and email consultations with a certified diabetes educator (WW), compared with standard diabetes nutrition counseling and education (standard care, SC). METHODS: In a 12-month randomized controlled trial at 16 U.S. research centers, 563 adults with T2DM (HbA1c 7-11%; BMI 27-50 kg/m2 ) were assigned to either the commercially available WW program (regular community meetings, online tools), plus telephone and email counseling from a certified diabetes educator, or to SC (initial in-person diabetes nutrition counseling/education, with follow-up informational materials). RESULTS: Follow-up rate was 86%. Twelve-month HbA1c changes for WW and SC were -0.32 and +0.16, respectively; 24% of WW versus 14% of SC achieved HbA1c <7.0% (P = 0.004). Weight losses were -4.0% for WW and -1.9% for SC (Ps < 0.001). 26% of WW versus 12% of SC reduced diabetes medications (P < 0.001). WW participants had greater reductions in waist circumference (P < 0.001) and C-reactive protein (P = 0.02) but did not differ on other cardiovascular risk factors. CONCLUSIONS: Widely available commercial weight loss programs with community and online components, combined with scalable complementary diabetes education, may represent accessible and effective components of management plans for adults with overweight/obesity and T2DM.


Assuntos
Diabetes Mellitus Tipo 2/terapia , Programas de Redução de Peso , Adolescente , Adulto , Idoso , Glicemia/metabolismo , Pressão Sanguínea , Índice de Massa Corporal , Proteína C-Reativa/metabolismo , Doenças Cardiovasculares/terapia , Colesterol/sangue , Aconselhamento , Correio Eletrônico , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Educação em Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/terapia , Sobrepeso/terapia , Estudos Prospectivos , Fatores de Risco , Sensibilidade e Especificidade , Telefone , Circunferência da Cintura , Adulto Jovem
20.
Circulation ; 110(19): 3036-42, 2004 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-15520310

RESUMO

BACKGROUND: Circumferential pulmonary vein ablation (CPVA) is effective in curing atrial fibrillation (AF), but new-onset left atrial tachycardia (AT) is a potential complication. We evaluated whether a modified CPVA approach including additional ablation lines on posterior wall and the mitral isthmus would reduce the incidence of AT after PV ablation. METHODS AND RESULTS: A total of 560 patients (291 men, 52%; age, 56.5+/-7.3 years) entered the study; 280 were randomized to CPVA alone (group 1) and 280 to modified CPVA (group 2). The primary end point was freedom from AT after the procedure. In group 1, 28 patients (10%) experienced new-onset AT, and 41 (14.3%) experienced recurrent AF. In group 2, 11 patients (3.9%) experienced AT, and 36 (12.9%) had recurrent AF. Group 1 was more likely to experience AT than group 2 (P=0.005). Freedom from AF after ablation was similar in both groups (P=0.57). Among those in group 1, gap-related macroreentrant AT was documented in 23 of the 28 patients (82%), and focal AT was found in 5 (18%). In group 2, gap-related macroreentrant AT was found in 8 of the 11 patients (73%), and focal AT was seen in 3 (27%). Two patients in group 1 and 1 patient in group 2 had both AT and AF. The strongest predictor of AT was the presence of gaps (P<0.001). CONCLUSIONS: Modified CPVA is as effective as CPVA in preventing AF but is associated with a lower risk of developing incessant AT.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Taquicardia Atrial Ectópica/prevenção & controle , Idoso , Ablação por Cateter/métodos , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Doença Iatrogênica/prevenção & controle , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Taquicardia Atrial Ectópica/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA