Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 248
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Radiology ; 309(3): e230425, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38085082

RESUMO

Background Transthyretin amyloid cardiomyopathy (ATTR-CM) often coexists with severe aortic stenosis (AS). Although strain analysis from cardiac MRI and echocardiography was demonstrated to predict coexisting ATTR-CM, comparable data from four-dimensional (4D) cardiac CT are lacking despite wide availability. Purpose To evaluate the diagnostic performance of 4D cardiac CT-derived parameters in identifying ATTR-CM in older adults considered for transcatheter aortic valve implantation (TAVI). Materials and Methods This prospective single-center screening study for ATTR-CM included consecutive patients with severe AS considered for TAVI who underwent 4D cardiac CT between August 2019 and August 2021 approximately 1 day before technetium 99m (99mTc) 3,3-diphosphono-1,2-propanodicarboxylic-acid (DPD) scintigraphy. The diagnostic performance of CT-based left ventricular (LV), right ventricular, and left atrial dimensions, ejection fraction (EF), and myocardial strain were evaluated against 99mTc-DPD scintigraphy as the reference standard to identify ATTR-CM. Predictors and an unweighted cardiac CT score were validated with internal bootstrapping. The assignment of variables to the score was based on cutoff values achieving the highest Youden index J. Results Among 263 participants (mean age, 83 years ± 4.6 [SD]; 149 male and 114 female participants), 99mTc-DPD scintigraphy (Perugini grade 2 or 3) confirmed coexisting ATTR-CM in 27 (10.3%). CT-derived LV mass index, LV and LA global longitudinal strain (GLS), and relative apical longitudinal strain each predicted the presence of ATTR-CM with an area under the curve (AUC) of at least 0.70. Implementing these parameters with cutoff values of 81 g/m2 or higher, -14.9% or higher, less than 11.5%, and 1.7 or higher in the CT score, respectively, yielded high diagnostic performance (AUC = 0.89; 95% CI: 0.81, 0.94; P < .001) robust to internal bootstrapping validation (AUC = 0.88; 95% CI: 0.82, 0.94). If two criteria were fulfilled, the sensitivity and specificity in the detection of ATTR-CM were 96.3% (95% CI: 81.0, 99.9) and 58.9% (95% CI: 52.3, 65.2), respectively. Conclusion When compared against 99mTc-DPD scintigraphy as the reference standard, routine 4D cardiac CT in older adults considered for TAVI provided high diagnostic performance in the detection of concomitant ATTR-CM by assessing LV and left atrial GLS, relative apical longitudinal strain, and LV mass index. ClinicalTrials.gov registration no.: NCT04061213 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Tavakoli and Onder in this issue.


Assuntos
Neuropatias Amiloides Familiares , Amiloidose , Estenose da Valva Aórtica , Cardiomiopatias , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Pré-Albumina , Estudos Prospectivos , Amiloidose/complicações , Tomografia Computadorizada por Raios X , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/diagnóstico por imagem
2.
Am Heart J ; 266: 128-137, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37703948

RESUMO

BACKGROUND: The identification of hemodynamically stable pulmonary embolism (PE) patients who may benefit from advanced treatment beyond anticoagulation is unclear. However, when intervention is deemed necessary by the PE patient's care team, data to select the most advantageous interventional treatment option are lacking. Limiting factors include major bleeding risks with systemic and locally delivered thrombolytics and the overall lack of randomized controlled trial (RCT) data for interventional treatment strategies. Considering the expansion of the pulmonary embolism response team (PERT) model, corresponding rise in interventional treatment, and number of thrombolytic and nonthrombolytic catheter-directed devices coming to market, robust evidence is needed to identify the safest and most effective interventional option for patients. METHODS: The PEERLESS study (ClinicalTrials.gov identifier: NCT05111613) is a currently enrolling multinational RCT comparing large-bore mechanical thrombectomy (MT) with the FlowTriever System (Inari Medical, Irvine, CA) vs catheter-directed thrombolysis (CDT). A total of 550 hemodynamically stable PE patients with right ventricular (RV) dysfunction and additional clinical risk factors will undergo 1:1 randomization. Up to 150 additional patients with absolute thrombolytic contraindications may be enrolled into a nonrandomized MT cohort for separate analysis. The primary end point will be assessed at hospital discharge or 7 days post procedure, whichever is sooner, and is a composite of the following clinical outcomes constructed as a hierarchal win ratio: (1) all-cause mortality, (2) intracranial hemorrhage, (3) major bleeding, (4) clinical deterioration and/or escalation to bailout, and (5) intensive care unit admission and length of stay. The first 4 components of the win ratio will be adjudicated by a Clinical Events Committee, and all components will be assessed individually as secondary end points. Other key secondary end points include all-cause mortality and readmission within 30 days of procedure and device- and drug-related serious adverse events through the 30-day visit. IMPLICATIONS: PEERLESS is the first RCT to compare 2 different interventional treatment strategies for hemodynamically stable PE and results will inform strategy selection after the physician or PERT determines advanced therapy is warranted.


Assuntos
Embolia Pulmonar , Terapia Trombolítica , Humanos , Terapia Trombolítica/métodos , Resultado do Tratamento , Embolia Pulmonar/tratamento farmacológico , Fibrinolíticos , Hemorragia/induzido quimicamente , Catéteres , Trombectomia/efeitos adversos
3.
Catheter Cardiovasc Interv ; 101(1): 199-208, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36453455

RESUMO

BACKGROUND: Elliptical shape of the aortic annulus has been associated with an increased risk of device failure after transcatheter aortic valve implantation (TAVI) compared with a circular annular shape. AIMS: To assess the impact of annulus ellipticity on procedural outcomes and device performance in patients undergoing TAVI. METHODS: In a prospective TAVI registry, aortic annulus ellipticity was assessed by preprocedural multidetector computed tomography. The annulus ratios, defined by the ratio of minimum and maximum annulus diameters measured in a transverse double oblique plane, were split into tertiles for comparisons between groups. RESULTS: A total of 1732 patients undergoing TAVI between August 2007 and June 2020 were included in the present analysis. Patients in the tertile with the most elliptical shape of the annulus were more likely to be female (59.7% vs. 47.9%; p < 0.001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (5.4 ± 3.8 vs. 4.8 ± 3.5; p = 0.002). There were no significant differences in the rate of technical success (95.3% vs. 96.5%; p = 0.235), device success (83.6% vs. 86.5%; p = 0.118) and intended valve performance (90.7% vs. 91.7; p = 0.503) between patients in the most elliptical tertile and the rest. However, valve dislocation/embolization occurred more frequently in patients with elliptical as compared to circular annular shape (2.6% vs. 1.2%; p = 0.046). CONCLUSIONS: Ellipticity of the aortic annulus does not affect procedural and device outcomes in patients undergoing TAVI irrespective of transcatheter heart valve design and generation. https:www.//clinicaltrials.gov. NCT01368250.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Estudos Prospectivos , Resultado do Tratamento
4.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34894124

RESUMO

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
5.
Am Heart J ; 244: 94-106, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34788603

RESUMO

BACKGROUND: Ascending aortic root anatomy is routinely evaluated on pre-procedural multi-detector computed tomography (MDCT). However, its clinical significance has not been adequately studied. We aimed to investigate the impact of the sinus of Valsalva (SOV) dimension on clinical outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective TAVI registry, we retrospectively assessed SOV dimensions by pre-procedural MDCT. Patients were stratified according to tertiles of SOV diameter indexed to body surface area (SOVi). The primary endpoint was all-cause mortality at 1 year. RESULTS: Among 2066 consecutive patients undergoing TAVI between August 2007 and June 2018, 1554 patients were eligible for the present analysis. Patients in the large SOVi group were older (83 ± 6 vs 82 ± 6 vs 81 ± 6; P < .001) and had a higher Society of Thoracic Surgeons Predicted Risk of Mortality (6.3 ± 3.8 vs 5.1 ± 3.1 vs 4.9 ± 3.5; P < .001) than those in the other groups. Patients in the large SOVi group had a higher incidence of moderate or severe paravalvular regurgitation (11.9% vs 4.5% vs 3.5%; P < .001). At 1 year, a large SOVi was independently associated with an increased risk of mortality (HR: 1.62; 95% CI: 1.19-2.21; P = .002) and major or life-threatening bleeding (HR: 1.30; 95% CI: 1.02-1.65; P = .035). CONCLUSIONS: Dilatation of the aortic root at the SOV was associated with adverse outcomes after TAVI. The assessment of the aortic root should be integrated into the risk stratification system in patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Seio Aórtico , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Seio Aórtico/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 99(6): 1908-1917, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35170846

RESUMO

BACKGROUND: Increased left ventricular afterload resulting from severe aortic stenosis (AS) leads to progressive cardiac remodeling. Left atrial enlargement (LAE) is an early manifestation in a series of maladaptive changes and may affect clinical outcomes after valvular replacement therapy. The aim of this study is to determine the impact of LAE on clinical outcomes in symptomatic patients with severe AS undergoing transcatheter aortic valve implantation (TAVI). METHODS: In a prospective single-center TAVI registry, we analyzed LA dimensions measured by echocardiography before intervention. Patients with atrial fibrillation or concomitant mitral valve disease were excluded. LAE was defined as indexed LA volume >34 ml/m2 . The primary endpoint was cardiovascular death (CVD) at 1 year. RESULTS: Among 1663 patients undergoing TAVI between August 2007 and December 2016, 768 (46.2%) were eligible for the present analysis and 486 patients had LAE. The prevalence of LAE was higher in males (68.3%) as compared to females (58.8%). Patients with LAE were older (82.3 ± 6.7 years vs. 80.0 ± 6.4 years) and had a higher STS-PROM score (6.1 ± 4.7% vs. 4.7 ± 2.9%). After adjustment, patients with LAE had an increased risk of CVD at 1-year compared to patients with normal LA dimensions (49 [10.4%] vs. 8 [2.9%]; HRadj , 3.52; 95% CI, 1.66-7.44)]. In multivariable analysis, LAE was independently associated with an increased risk of CVD at 1-year (HRadj , 3.52; 95% CI, 1.66-7.44). CONCLUSIONS: LAE secondary to AS was documented in a significant proportion of patients undergoing TAVI and was associated with a more than threefold increased risk of CVD at 1-year.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
7.
BMC Cardiovasc Disord ; 22(1): 178, 2022 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-35436856

RESUMO

BACKGROUND: Computed tomography angiography (CTA) is a cornerstone in the pre- transcatheter aortic valve replacement (TAVI) assessment. We evaluated the diagnostic performance of CTA and coronary artery calcium score (CACS) for CAD evaluation compared to invasive coronary angiography in a cohort of TAVI patients. METHODS: In consecutive TAVI patients without prior coronary revascularization and device implants, CAD was assessment by quantitative analysis in CTA. (a) Patients with non-evaluable segments were classified as obstructive CAD. (b) In patients with non-evaluable segments a CACS cut-off of 100 was applied for obstructive CAD. The reference standard was quantitative invasive coronary angiography (QCA, i.e. ≥ 50% stenosis). RESULTS: 100 consecutive patients were retrospectively included, age was 82.3 ± 6.5 years and 30% of patients had CAD. In 16% of the patients, adequate visualization of the entire coronary tree (all 16 segments) was possible with CTA, while 84% had at least one segment which was not evaluable for CAD analysis due to impaired image quality. On a per-patient analysis, where patients with low image quality were classified as CAD, CTA showed a sensitivity of 100% (95% CI 88.4-100.0), specificity of 11.4% (95% CI 5.1-21.3), PPV of 32.6% (95% CI 30.8-34.5), NPV of 100% and diagnostic accuracy of 38% (95% CI 28.5-48.3) for obstructive CAD. When applying a combined approach of CTA (in patients with good image quality) and CACS (in patients with low image quality), the sensitivity and NPV remained at 100% and obstructive CAD could be ruled out in 20% of the TAVI patients, versus 8% using CTA alone. CONCLUSION: In routinely acquired pre-TAVI CTA, the image quality was insufficient in a high proportion of patients for the assessment of the entire coronary artery tree. However, when adding CACS in patients with low image quality to quantitative CTA assessment in patients with good image quality, obstructive CAD could be ruled-out in 1/5 of the patients and may therefore constitute a strategy to streamline pre-procedural workup, and reduce risk, radiation and costs in selected TAVI patients without prior coronary revascularization or device implants.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
JAMA ; 327(18): 1771-1781, 2022 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-35368058

RESUMO

Importance: Coronary plaques that are prone to rupture and cause adverse cardiac events are characterized by large plaque burden, large lipid content, and thin fibrous caps. Statins can halt the progression of coronary atherosclerosis; however, the effect of the proprotein convertase subtilisin kexin type 9 inhibitor alirocumab added to statin therapy on plaque burden and composition remains largely unknown. Objective: To determine the effects of alirocumab on coronary atherosclerosis using serial multimodality intracoronary imaging in patients with acute myocardial infarction. Design, Setting, and Participants: The PACMAN-AMI double-blind, placebo-controlled, randomized clinical trial (enrollment: May 9, 2017, through October 7, 2020; final follow-up: October 13, 2021) enrolled 300 patients undergoing percutaneous coronary intervention for acute myocardial infarction at 9 academic European hospitals. Interventions: Patients were randomized to receive biweekly subcutaneous alirocumab (150 mg; n = 148) or placebo (n = 152), initiated less than 24 hours after urgent percutaneous coronary intervention of the culprit lesion, for 52 weeks in addition to high-intensity statin therapy (rosuvastatin, 20 mg). Main Outcomes and Measures: Intravascular ultrasonography (IVUS), near-infrared spectroscopy, and optical coherence tomography were serially performed in the 2 non-infarct-related coronary arteries at baseline and after 52 weeks. The primary efficacy end point was the change in IVUS-derived percent atheroma volume from baseline to week 52. Two powered secondary end points were changes in near-infrared spectroscopy-derived maximum lipid core burden index within 4 mm (higher values indicating greater lipid content) and optical coherence tomography-derived minimal fibrous cap thickness (smaller values indicating thin-capped, vulnerable plaques) from baseline to week 52. Results: Among 300 randomized patients (mean [SD] age, 58.5 [9.7] years; 56 [18.7%] women; mean [SD] low-density lipoprotein cholesterol level, 152.4 [33.8] mg/dL), 265 (88.3%) underwent serial IVUS imaging in 537 arteries. At 52 weeks, mean change in percent atheroma volume was -2.13% with alirocumab vs -0.92% with placebo (difference, -1.21% [95% CI, -1.78% to -0.65%], P < .001). Mean change in maximum lipid core burden index within 4 mm was -79.42 with alirocumab vs -37.60 with placebo (difference, -41.24 [95% CI, -70.71 to -11.77]; P = .006). Mean change in minimal fibrous cap thickness was 62.67 µm with alirocumab vs 33.19 µm with placebo (difference, 29.65 µm [95% CI, 11.75-47.55]; P = .001). Adverse events occurred in 70.7% of patients treated with alirocumab vs 72.8% of patients receiving placebo. Conclusions and Relevance: Among patients with acute myocardial infarction, the addition of subcutaneous biweekly alirocumab, compared with placebo, to high-intensity statin therapy resulted in significantly greater coronary plaque regression in non-infarct-related arteries after 52 weeks. Further research is needed to understand whether alirocumab improves clinical outcomes in this population. Trial Registration: ClinicalTrials.gov Identifier: NCT03067844.


Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Inibidores de PCSK9 , Placa Aterosclerótica , Idoso , Anticorpos Monoclonais Humanizados/uso terapêutico , LDL-Colesterol , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Método Duplo-Cego , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/tratamento farmacológico , Inibidores de PCSK9/uso terapêutico , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/tratamento farmacológico , Resultado do Tratamento
9.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33733675

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 98(5): E768-E779, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33857355

RESUMO

OBJECTIVES: To investigate the impact of transcatheter heart valve (THV) sizing on procedural results and clinical outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of individual THV sizing for patients with borderline aortic annulus anatomy remains unclear. METHODS: In the prospective BernTAVI registry, THV sizing conditions were retrospectively evaluated, and patients were categorized into three groups based on the recommendations and the sizing chart of the manufacturers: optimal sizing, borderline sizing (THV size located within 5% to each border of the optimal sizing recommendation), and suboptimal sizing (THV size outside the recommended range). The latter two groups were further subcategorized into THV-oversizing and THV-undersizing. The primary endpoint was a composite of all-cause death and unplanned repeat intervention at 1 year. RESULTS: Out of a total of 1,638 patients who underwent TAVI, 9.5 and 15.6% of patients were categorized into the borderline and suboptimal sizing group, respectively. Device success was achieved in 87.4, 88.9, and 83.6% of patients with optimal, borderline, and suboptimal sizing, respectively. The primary endpoint occurred in 12.3% of patients with optimal sizing, 14.9% of patients with borderline sizing (HRadj 1.35, 95%CI 0.87-2.09), and in 17.4% of patients with suboptimal sizing (HRadj 1.42, 95%CI 1.01-1.99). Within the suboptimal sizing cohort, unfavorable outcomes were mainly associated with THV undersizing (device success: 76.4%, primary endpoint: 23.9%, HRadj 1.98, 95%CI 1.36-2.87). CONCLUSION: Suboptimal TAVI prosthesis sizing is associated with an increased risk of all-cause death and unplanned repeat intervention within 1 year largely attributable to undersized THV prostheses.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 98(2): E213-E221, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33754441

RESUMO

OBJECTIVES: We aimed to assess the ischemic and bleeding risks of single antiplatelet therapy (SAPT) with prasugrel compared with standard dual antiplatelet therapy (DAPT) (aspirin plus clopidogrel for 1 year) in patients with chronic coronary syndrome (CCS) treated with new generation drug-eluting stents (DES). BACKGROUND: To date, data on SAPT with potent P2Y12 inhibitors in the absence of aspirin immediately after PCI are limited. METHODS: Between January 2009 and November 2019, all CCS patients undergoing percutaneous coronary intervention (PCI) enrolled to the Bern PCI registry were considered for analysis. We performed propensity score matching in a 1:4 fashion to compare patients who received SAPT with prasugrel versus standard DAPT. The primary ischemic endpoint was a composite of cardiovascular death, myocardial infarction, and stroke and the primary bleeding endpoint was BARC 3 or 5 bleeding, both assessed at 1 year. RESULTS: After propensity score matching, the final study population consisted of 225 patients with SAPT and 889 with DAPT. There was no significant difference in rates of the primary ischemic (5.2% vs. 4.2%, p = .50) or the primary bleeding (1.5% vs. 2.0%, p = .60) endpoints between groups. SAPT was not associated with an increased risk of definite stent thrombosis (0.9% vs. 0.8%, p = .83). CONCLUSIONS: Among selected CCS patients undergoing PCI with DES, SAPT with prasugrel was not associated with an excess of ischemic events compared with standard DAPT. No difference in bleeding was observed either. The results may serve as the basis for larger trials assessing the potential benefits and risks of SAPT.


Assuntos
Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Quimioterapia Combinada , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Cloridrato de Prasugrel/efeitos adversos , Resultado do Tratamento
12.
Eur Heart J ; 41(38): 3743-3749, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33029615

RESUMO

AIMS: To validate the set of clinical and biochemical criteria proposed by consensus by the Academic Research Consortium (ARC) for High Bleeding Risk (HBR) for the identification of HBR patients. These criteria were categorized into major and minor, if expected to carry in isolation, respectively, ≥4% and <4% Bleeding Academic Research Consortium (BARC) 3 or 5 bleeding risk within 1-year after percutaneous coronary intervention (PCI). High bleeding risk patients are those meeting at least 1 major or 2 minor criteria. METHODS AND RESULTS: All patients undergoing PCI at Bern University Hospital, between February 2009 and September 2018 were prospectively entered into the Bern PCI Registry (NCT02241291). Age, haemoglobin, platelet count, creatinine, and use of oral anticoagulation were prospectively collected, while the remaining HBR criteria except for planned surgery were retrospectively adjudicated. A total of 16 580 participants with complete ARC-HBR criteria were included. After assigning 1 point to each major and 0.5 point to each minor criterion, we observed for every 0.5 score increase a step-wise augmentation of BARC 3 or 5 bleeding rates at 1 year ranging from 1.90% among patients fulfilling no criterion, through 4.01%, 5.98%, 7.42%, 8.60%, 12.21%, 12.29%, and 17.64%. All major and five out of six minor criteria, conferred in isolation a risk for BARC 3 or 5 bleeding at 1 year exceeding 4% at the upper limit of the 95% confidence intervals. CONCLUSION: All major and the majority of minor ARC-HBR criteria identify in isolation patients at HBR.


Assuntos
Intervenção Coronária Percutânea , Hemorragia/induzido quimicamente , Humanos , Inibidores da Agregação Plaquetária , Estudos Retrospectivos , Fatores de Risco
13.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
14.
Lancet ; 394(10205): 1243-1253, 2019 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-31488372

RESUMO

BACKGROUND: Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS: The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS: Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION: In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING: Biotronik.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Stents Farmacológicos , Everolimo/uso terapêutico , Imunossupressores/uso terapêutico , Intervenção Coronária Percutânea/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Sirolimo/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Método Simples-Cego
15.
Lancet ; 394(10209): 1619-1628, 2019 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-31570258

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is the preferred treatment option for older patients with symptomatic severe aortic stenosis. Differences in the properties of available TAVR systems can affect clinical outcomes. Among patients undergoing TAVR, we compared the self-expanding ACURATE neo TAVR system with the balloon-expandable SAPIEN 3 TAVR system with regard to early safety and efficacy. METHODS: In this randomised non-inferiority trial, patients (aged ≥75 years) undergoing transfemoral TAVR for treatment of symptomatic severe aortic stenosis, and who were deemed to be at increased surgical risk, were recruited at 20 tertiary heart valve centres in Germany, the Netherlands, Switzerland, and the UK. Participants were randomly assigned (1:1) to receive treatment with the ACURATE neo or the SAPIEN 3 with a computer-based randomly permuted block scheme, stratified by study centre and Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) category. The primary composite safety and efficacy endpoint comprised all-cause death, any stroke, life-threatening or disabling bleeding, major vascular complications, coronary artery obstruction requiring intervention, acute kidney injury (stage 2 or 3), rehospitalisation for valve-related symptoms or congestive heart failure, valve-related dysfunction requiring repeat procedure, moderate or severe prosthetic valve regurgitation, or prosthetic valve stenosis within 30 days of the procedure. Endpoint assessors were masked to treatment allocation. Non-inferiority of ACURATE neo compared with SAPIEN 3 was assessed in the intention-to-treat population on the basis of a risk-difference margin of 7·7% for the primary composite endpoint, with a one-sided α of 0·05. This trial is registered with ClinicalTrials.gov (number NCT03011346) and is ongoing but not recruiting. FINDINGS: Between Feb 8, 2017, and Feb 2, 2019, up to 5132 patients were screened and 739 (mean age 82·8 years [SD 4·1]; median STS-PROM score 3·5% [IQR 2·6-5·0]) were enrolled. 30-day follow-up was available for 367 (99%) of 372 patients allocated to the ACURATE neo group, and 364 (99%) of 367 allocated to the SAPIEN 3 group. Within 30 days, the primary endpoint occurred in 87 (24%) patients in the ACURATE neo and in 60 (16%) in the SAPIEN 3 group; thus, non-inferiority of the ACURATE neo was not met (absolute risk difference 7·1% [upper 95% confidence limit 12·0%], p=0·42). Secondary analysis of the primary endpoint suggested superiority of the SAPIEN 3 device over the ACURATE neo device (95% CI for risk difference -1·3 to -12·9, p=0·0156). The ACURATE neo and SAPIEN 3 groups did not differ in incidence of all-cause death (nine patients [2%] vs three [1%]) and stroke (seven [2%] vs 11 [3%]); whereas acute kidney injury (11 [3%] vs three [1%]) and moderate or severe prosthetic aortic regurgitation (34 [9%] vs ten [3%]) were more common in the ACURATE neo group. INTERPRETATION: TAVR with the self-expanding ACURATE neo did not meet non-inferiority compared to the balloon-expandable SAPIEN 3 device in terms of early safety and clinical efficacy outcomes. An early composite safety and efficacy endpoint was useful in discriminating the performance of different TAVR systems. FUNDING: Boston Scientific (USA).


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Causas de Morte/tendências , Feminino , Alemanha/epidemiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Países Baixos/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Índice de Gravidade de Doença , Suíça/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Reino Unido/epidemiologia
16.
Eur Heart J ; 40(17): 1342-1351, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30596992

RESUMO

AIMS: Multivalvular disease is of increasing concern in elderly patients undergoing transcatheter aortic valve replacement (TAVR). The objective of the present analysis was to investigate the impact of concomitant mitral stenosis (MS) on clinical outcomes in patients undergoing TAVR for severe, symptomatic aortic stenosis (AS). METHODS AND RESULTS: Among 1339 patients undergoing TAVR between August 2007 and December 2015, adequate echocardiographic data for the assessment of severity and aetiology of MS was available in 971 (72.5%) patients. Patients were stratified according to degree and aetiology of concomitant MS. Mitral stenosis was documented in 176 (18.1%) TAVR patients (mean mitral valve area 1.9 ± 0.4 cm2) and considered degenerative in 110 (62.5%) and rheumatic in 66 (37.5%) patients, respectively. Mitral stenosis was categorized as moderate/severe in 28 patients (2.9%). Baseline characteristics were comparable between patients with vs. without MS. At 1 year, patients with MS were at increased risk of cardiovascular death [36 (21.4%) vs. 66 (8.7%); adjusted hazard ratio (HRadj) 3.64, 95% confidence interval (CI) 2.38-5.56] and disabling stroke [12 (7.1%) vs. 23 (3.0%); HRadj 2.98, 95% CI 1.46-6.09] as compared to patients without MS. Differences in cardiovascular death and disabling stroke emerged within 30 days of the index procedure and were largely driven by a difference in patients with rheumatic MS [cardiovascular death: 7 (10.6%) vs. 24 (3.2%), HRadj 4.80, 95% CI 1.98-11.6; disabling stroke: 4 (6.1%) vs. 16 (2.0%), HRadj 4.18, 95% CI 1.34-13.0]. CONCLUSION: Concomitant MS was documented in approximately one-fifth of patients undergoing TAVR for severe, symptomatic AS and associated with a three-fold increased risk of cardiovascular adverse events at 1 year. The difference emerged early and was largely driven by patients with rheumatic MS.


Assuntos
Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Morte , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/epidemiologia , Suíça/epidemiologia , Resultado do Tratamento
17.
Circulation ; 137(2): 184-196, 2018 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-29311349

RESUMO

A series of hemodynamic and pathological responses occur in chronic aortic regurgitation, which eventually result in myocardial fibrosis and irreversible left ventricular dysfunction. According to guidelines, valvular surgery is recommended with the development of symptoms, left ventricular systolic dysfunction, or left ventricular dilatation. The optimal timing of surgical intervention has recently been questioned with documentation of irreversible myocardial damage resulting in incomplete left ventricular recovery and adverse clinical outcomes after surgery. Recognizing the shortcomings of the guidelines, we performed a comprehensive review on the novel diagnostic methods that have been shown to improve the detection of subclinical ventricular dysfunction in chronic aortic regurgitation and to improve prediction of outcomes.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/terapia , Doenças Assintomáticas , Fármacos Cardiovasculares/uso terapêutico , Doença Crônica , Progressão da Doença , Diagnóstico Precoce , Feminino , Fibrose , Implante de Prótese de Valva Cardíaca , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Esquerda/terapia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos
18.
Catheter Cardiovasc Interv ; 93(5): 982-988, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30548794

RESUMO

BACKGROUND: Live case demonstrations serve as an educational tool for interventional techniques in cardiology. The aim of this study was to assess the safety and technical success of percutaneous patent foramen ovale (PFO) closure during live case demonstrations. METHODS: All patients who had undergone percutaneous PFO closure with Amplatzer devices during live case demonstrations at our institution were consecutively included in this retrospective analysis. Procedure related events were compared with summary event rates derived from the eight randomized controlled trials (RCTs) investigating PFO closure, as well as with a propensity matched cohort of patients treated under usual conditions. RESULTS: From April 2004 to June 2015, 142 patients underwent percutaneous PFO closure during live demonstrations, mainly for secondary prevention of cryptogenic cerebrovascular events. The interventions were fluoroscopy guided and successful in all but three cases (2%). Minor adverse events occurred in nine patients (6%). Contrast TEE performed at about 6 months showed complete closure in 84%. No significant differences with regard to technical success and major complications rate were found compared to RCTs, except for an increased rate of minor bleeding observed during live case demonstrations (P for difference < 0.001), mainly attributable to concomitant arterial access for incidental coronary angiography performed in 70% of patients. Except for slightly longer procedure duration, no difference was found compared to a matched population treated under usual conditions. CONCLUSION: Percutaneous PFO closure can be performed during live case demonstrations with the same high technical success as during routine cases.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial/terapia , Educação Médica , Gravação em Vídeo , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Radiografia Intervencionista , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Eur Heart J ; 38(28): 2211-2217, 2017 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-28430920

RESUMO

AIMS: To analyse reasons, timing and predictors of hospital readmissions after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: Patients included in the Bern TAVI Registry between August 2007 and June 2014 were analysed. Fine and Gray competing risk regression was used to identify factors predictive of hospital readmission within 1 year after TAVI with bootstrap analysis for internal validation. Of 868 patients alive at discharge, 221 (25.4%) were readmitted within 1 year. Compared with patients not requiring readmission, those with at least one readmission more frequently were male and more often had atrial fibrillation and higher creatinine values (P < 0.05 for all cases). For overall 308 readmissions, cardiovascular causes accounted for 46.1% with heart failure as the most frequent indication; non-cardiovascular readmissions occurred for surgery (11.7%), gastrointestinal disorders (9.7%), malignancy (4.9%), respiratory diseases (4.6%) and chronic kidney failure (2.6%). Male gender (subhazard ratio, SHR, 1.33, 95% confidence intervals, CI, 1.02-1.73, P = 0.035) and stage 3 kidney injury (SHR 2.04, 95% CI 1.12-3.71, P = 0.021) were found independent risk factors for any hospital readmission, whereas previous myocardial infarction (SHR 1.88, 95% CI 1.22-2.90, P = 0.004) and in-hospital life-threatening bleeding (SHR 2.18, 95%CI 1.24-3.85, P = 0.007) were associated with cardiovascular readmissions. The event rate for mortality was significantly increased after readmissions for any cause (RR 4.29, 95% CI 2.86-6.42, P < 0.001). CONCLUSION: Hospital readmission was observed in one out of four patients during the first year after TAVI and was associated with a significant increase in mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Readmissão do Paciente/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/mortalidade , Feminino , Humanos , Tempo de Internação , Masculino , Complicações Pós-Operatórias/etiologia , Prognóstico , Estudos Prospectivos , Sistema de Registros , Análise de Regressão , Suíça/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA