1.
Med Phys ; 36(11): 5149-61, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19994525

RESUMO

Thomson scattering x-ray sources can provide spectral distributions that are ideally suited for mammography with sufficient fluence rates. In this article, the authors investigate the effects of different spectral distributions on the image quality in simulated images of a breast mammographic phantom containing details of different compositions and thicknesses. They simulated monochromatic, quasimonochromatic, and polychromatic x-ray sources in order to define the energy for maximum figure of merit (signal-difference-to-noise ratio squared/mean glandular dose), the effect of an energy spread, and the effect of the presence of higher-order harmonics. The advantages of these sources with respect to conventional polychromatic sources as a function of phantom and detail thickness were also investigated. The results show that the energy for the figure of merit peak is between 16 and 27.4 keV, depending on the phantom thickness and detail composition and thickness. An energy spread of about 1 keV standard deviation, easily achievable with compact x-ray sources, does not appreciably affect the image quality.


Assuntos
Simulação por Computador , Mamografia/instrumentação , Mamografia/métodos , Método de Monte Carlo , Espalhamento de Radiação , Raios X , Algoritmos , Calcinose/diagnóstico por imagem , Feminino , Humanos , Modelos Biológicos , Imagens de Fantasmas , Fótons , Doses de Radiação , Filme para Raios X
2.
Med Phys ; 33(9): 3469-77, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17022243

RESUMO

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.


Assuntos
Análise de Falha de Equipamento/instrumentação , Mamografia/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/instrumentação , Espectrometria por Raios X/instrumentação , Calibragem , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Miniaturização , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria por Raios X/métodos
3.
Methods Inf Med ; 44(2): 244-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15924184

RESUMO

OBJECTIVES: The next generation of high energy physics (HEP) experiments requires a GRID approach to a distributed computing system: the key concept is the Virtual ORGANISATION (VO), a group of distributed users with a common goal and the will to share their resources. METHODS: A similar approach, applied to a group of hospitals that joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. The application code makes use of neural networks for the image analysis and is useful in improving the radiologists' diagnostic performance. GRID services allow remote image analysis and interactive online diagnosis, with a potential for a relevant reduction of the delays presently associated with screening programs. RESULTS AND CONCLUSIONS: A prototype of the system, based on AliEn GRID Services [1], is already available, with a central server running common services [2] and several clients connecting to it. Mammograms can be acquired in any location; the related information required to select and access them at any time is stored in a common service called Data Catalogue, which can be queried by any client. Thanks to the PROOF facility [3], the result of a query can be used as input for analysis algorithms, which are executed on the nodes where the input images are stored,. The selected approach avoids data transfers for all the images with a negative diagnosis and allows an almost real time diagnosis for the set of images with high cancer probability.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Internet/instrumentação , Mamografia , Sistemas de Informação em Radiologia/instrumentação , Integração de Sistemas , Telerradiologia/instrumentação , Algoritmos , Sistemas de Gerenciamento de Base de Dados , Bases de Dados Factuais , Diagnóstico por Computador , Europa (Continente) , Feminino , Humanos , Internacionalidade , Itália , Sistemas Computadorizados de Registros Médicos , Desenvolvimento de Programas , Interface Usuário-Computador
4.
Med Phys ; 31(10): 2763-70, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15543781

RESUMO

In routine applications, information about the photon flux of x-ray tubes is obtained from exposure measurements and cataloged spectra. This approach relies mainly on the assumption that the real spectrum is correctly approximated by the cataloged one, once the main characteristics of the tube such as voltage, target material, anode angle, and filters are taken account of. In practice, all this information is not always available. Moreover, x-ray tubes with the same characteristics may have different spectra. We describe an apparatus that should be useful for quality control in hospitals and for characterizing new radiographic systems. The apparatus analyzes the spectrum generated by an x-ray mammographic unit. It is based on a commercial CZT produced by AMPTEK Inc. and a set of tungsten collimator disks. The electronics of the CZT are modified so as to obtain a faster response. The signal is digitized using an analog to digital converter with a sampling frequency of up to 20 MHz. The whole signal produced by the x-ray tube is acquired and analyzed off-line in order to accurately recognize pile-up events and reconstruct the emitted spectrum. The energy resolution has been determined using a calibrated x-ray source. Spectra were validated by comparison of the HVL measured using an ionization chamber.


Assuntos
Algoritmos , Análise de Falha de Equipamento/instrumentação , Mamografia/instrumentação , Molibdênio/química , Molibdênio/efeitos da radiação , Radiometria/instrumentação , Raios X , Desenho de Equipamento , Miniaturização , Garantia da Qualidade dos Cuidados de Saúde/métodos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador