Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 32(3): 329-37, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15791443

RESUMO

PURPOSE: Whole-body gamma camera counting is an alternative to faecal 111In collection for quantifying disease activity in inflammatory bowel disease (IBD) but requires administration of imaging activities of 111In. The aim of this study was to explore a dedicated whole-body counter which requires 20-fold less activity than gamma camera counting. METHODS: Thirty patients with known or suspected IBD received 99mTc-granulocytes (approximately 200 MBq) and 111In-granulocytes (approximately 0.5 MBq). The 99mTc-cells were injected 45 min after the 111In-cells and immediately after a baseline 111In whole-body count. The decay-corrected count at 120 h was expressed as a fraction of baseline to give whole-body 111In retention (WBR). One patient was excluded as the injected cells were non-viable. RESULTS: Median 45-min intravascular 111In recovery was 35% in patients compared with 43% in six normal volunteers (p<0.05). WBR in normals ranged from 91% to 93% and in 11 patients with negative 99mTc imaging from 87% to 96%. Only one of 11 patients with negative imaging had WBR <90% while 11/12 patients with WBR <90% had abnormal imaging. Ten of 13 patients with Crohn's disease (CD) had abnormal imaging. The lowest WBR in these ten was 77% and six had values of >90%. There was a significant association between WBR and 99mTc image grade (Rs=0.73, p<0.002) in 16 patients without CD, but not in 13 patients with CD (Rs=0.54, p>0.05). CONCLUSION: Dedicated whole-body counting is able to quantify disease activity in IBD but may give normal values in active CD.


Assuntos
Radioisótopos de Índio , Doenças Inflamatórias Intestinais/diagnóstico por imagem , Leucócitos/diagnóstico por imagem , Tecnécio Tc 99m Exametazima , Contagem Corporal Total/métodos , Adulto , Idoso , Estudos de Viabilidade , Feminino , Granulócitos/diagnóstico por imagem , Humanos , Doenças Inflamatórias Intestinais/classificação , Masculino , Pessoa de Meia-Idade , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Contagem Corporal Total/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA