Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(7): 1569-1576, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37313805

RESUMO

INTRODUCTION: Intermuscular implantations of subcutaneous implantable cardioverter-defibrillators (S-ICD) have been recommended, but the position of the anterior border of the latissimus dorsi muscle (LDM) has not previously been evaluated in establishing an incision line to facilitate the intermuscular approach. The objective of this study is to evalua the position and trend of the anterior border of the LDM in patients who are candidates for implantable cardioverter-defibrillators. METHODS: The distance from the back to the anterior border of the LDM (A) and the anterior-posterior width of the chest wall (B) were measured on computed tomography retrospectively, and the ratio (=A/B) was used as the position of the anterior border of the LDM. In addition, the variability and factors affecting the values were evaluated. RESULTS: An analysis was performed on 78 patients, and the position of the anterior border of the LDM (=A/B) exhibited a normal distribution, with a mean value of 0.53 ± 0.062 (0.41-0.69). The position of the anterior border of the LDM tended to be more anterior in younger, taller, male, primary prevention, nonheart failure, low brain natriuretic peptide level, and nondiabetic patients. CONCLUSION: The position of the anterior border of the LDM varied from case to case with variable results. Conventional incisions on the midaxillary line may be inappropriate for intermuscular implantations, and the position of the anterior border of the LDM should be evaluated in each individual case to establish the incision line.


Assuntos
Desfibriladores Implantáveis , Músculos Superficiais do Dorso , Ferida Cirúrgica , Humanos , Masculino , Músculos Superficiais do Dorso/diagnóstico por imagem , Músculos Superficiais do Dorso/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos
2.
J Cardiovasc Electrophysiol ; 34(3): 527-535, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36598438

RESUMO

BACKGROUND: Lesion gaps assessed by late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) are associated with the atrial fibrillation (AF) recurrence after pulmonary vein isolation. Animal studies have demonstrated that the catheter-contact force (CF), stability, and orientation are strongly associated with lesion formation. However, the impact of those procedural factors on the lesion characteristics associated with AF recurrence has not been well discussed. METHODS: A total of 30 patients with paroxysmal AF who underwent catheter ablation were retrospectively enrolled. Radiofrequency (RF) applications were performed with 35 W for 30 s in a point-by-point fashion under esophageal temperature monitoring. The inter-lesion distance was 4 mm. The lesions were visualized by LGE-MRI 3 months postprocedure and assessed by the LGE volume (ml), gap number (GN), and average gap length (AGL [mm]). The gaps were defined as nonenhancement sites of >4 mm. The procedural factors including the catheter-CF, stability, and orientation were calculated on the NavX system. RESULTS: Six (20%) of 30 patients had AF recurrences 12 months postablation. A univariate analysis demonstrated that the AGL was associated with AF recurrence (hazard ratio [HR]: 1.20, confidence interval [CI]: 1.03-1.42, p = .02). All AF recurrence were found in patients with an AGL of >7 mm. The catheter-CF and stability were associated with an AGL of >7 mm, but not the orientation (CF-HR: 0.62, CI: 0.39-0.97, p = .038; stability-HR: 0.8, CI: 0.66-0.98, p = .027). CONCLUSIONS: RF ablation with a low CF and poor catheter stability has a potential risk of creating large lesion gaps associated with AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/métodos , Recidiva , Veias Pulmonares/cirurgia , Átrios do Coração , Resultado do Tratamento
3.
Circ J ; 87(7): 939-946, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-36464278

RESUMO

BACKGROUND: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13-0.70; P=0.004) than the medical therapy group. CONCLUSIONS: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
4.
J Cardiovasc Electrophysiol ; 33(8): 1847-1856, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35761749

RESUMO

INTRODUCTION: The skin overlying cardiovascular implantable electronic devices (CIEDs) sometimes becomes very thin after implantations, which could cause a device erosion. The factors related to the skin thickness of device pockets have not been elucidated. This study aimed to evaluate the skin thickness of CIED pockets and search for the factors associated with the thickness. METHODS: Seventeen skin thickness points around the CIED pocket were measured through ultrasonography in each patient. RESULTS: A total of 101 patients (76 ± 11 years, 26 female) were enrolled. The median duration from the implantation to the examination was 95 months (quartile: 52.5-147.5). The median skin thickness overlying the device was 4.1 mm (3.3-5.9). Patients with heart failure and malignancy had thinner skin overlying the CIED than those without. A significant correlation existed between skin thickness and body mass index (BMI), hemoglobin, serum creatinine, estimated glomerular filtration rate (eGFR), and left ventricular ejection fraction. In contrast, age, gender, and device size did not exhibit a significant correlation with skin thickness. A multivariate logistic regression analysis revealed that chronic heart failure and a decrease in the eGFR and BMI were independent predictive factors of "very thin (≦3.3 mm)" skin of the CIED pocket late after an implantation. CONCLUSION: Aside from a low BMI, the comorbidities (low hemoglobin, heart failure, and renal dysfunction) had a stronger impact on the skin thickness overlying the device than the device size. A careful observation of the device pocket should be performed in patients with those risk factors.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
5.
Circ J ; 87(1): 29-40, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-35989301

RESUMO

BACKGROUND: The mechanism underlying the sex differences in atrial fibrillation (AF) recurrence following pulmonary vein (PV) isolation is not fully understood. We hypothesized that non-PV foci and epicardial adipose tissue (EAT) play a key role.Methods and Results: Data from 304 consecutive patients (75% males) who underwent contrast-enhanced computed tomography and catheter ablation of AF were reviewed. The EAT around the atrium was measured separately in 4 parts of the atrium. All patients underwent high-dose isoproterenol infusions to assess the non-PV foci. Significantly more non-PV foci and less EAT around the atrium were observed in female patients than in male patients. In males, those with non-PV foci on the left atrial (LA) anterior wall had significantly greater EAT for the same lesions than those without non-PV foci. During a median follow-up of 27 months, the predictors of AF recurrence after first catheter ablation were female sex, presence of non-PV foci, LA diameter, and septal EAT index. A sex-specific analysis revealed that LA diameter was a predictor only in males and that the presence of non-PV foci in the septal region was a strong predictor in males (hazard ratio [HR]: 2.24) and females (HR: 3.65). CONCLUSIONS: Sex-specific differences were observed in non-PV foci sites and local EAT and in regard to the predictors of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Caracteres Sexuais , Resultado do Tratamento , Recidiva , Átrios do Coração , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Tecido Adiposo/diagnóstico por imagem
6.
Circ J ; 86(8): 1273-1280, 2022 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-35387940

RESUMO

BACKGROUND: Several algorithms have been proposed for differentiating the right and left outflow tracts (RVOT/LVOT) arrhythmia origins from 12-lead electrocardiograms (ECGs); however, the procedure is complicated. A deep learning (DL) model, a form of artificial intelligence, can directly use ECGs and depict the importance of the leads and waveforms. This study aimed to create a visualized DL model that could classify arrhythmia origins more accurately.Methods and Results: This study enrolled 80 patients who underwent catheter ablation. A convolutional neural network-based model that could classify arrhythmia origins with 12-lead ECGs and visualize the leads that contributed to the diagnosis using a gradient-weighted class activation mapping method was developed. The average prediction results of the origins by the DL model were 89.4% (88.2-90.6) for accuracy and 95.2% (94.3-96.2) for recall, which were significantly better than when a conventional algorithm is used. The ratio of the contribution to the prediction differed between RVOT and LVOT origins. Although leads V1 to V3 and the limb leads had a focused balance in the LVOT group, the contribution ratio of leads aVR, aVL, and aVF was higher in the RVOT group. CONCLUSIONS: This study diagnosed the arrhythmia origins more accurately than the conventional algorithm, and clarified which part of the 12-lead waveforms contributed to the diagnosis. The visualized DL model was convincing and may play a role in understanding the pathogenesis of arrhythmias.


Assuntos
Ablação por Cateter , Aprendizado Profundo , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Inteligência Artificial , Ablação por Cateter/efeitos adversos , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Complexos Ventriculares Prematuros/diagnóstico
7.
Circ J ; 86(2): 233-242, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34219078

RESUMO

BACKGROUND: It is unclear whether there are differences in the clinical factors between atrial fibrillation (AF) recurrence and adverse clinical events (AEs), including stroke/transient ischemic attack (TIA), major bleeding, and death, after AF ablation.Methods and Results:We examined the data from a retrospective multicenter Japanese registry conducted at 24 cardiovascular centers between 2011 and 2017. Of the 3,451 patients (74.1% men; 63.3±10.3 years) who underwent AF ablation, 1,046 (30.3%) had AF recurrence and 224 (6.5%) suffered AEs (51 strokes/TIAs, 71 major bleeding events, and 36 deaths) over a median follow-up of 20.7 months. After multivariate adjustment, female sex, persistent and long-lasting persistent AF (vs. paroxysmal AF), and stepwise increased left atrial diameter (LAd) quartiles were significantly associated with post-ablation recurrences. A multivariate analysis revealed that an age ≥75 years (vs. <65 years), body weight <50 kg, diabetes, vascular disease, left ventricular (LV) ejection fraction <40% (vs. ≥50%), Lad ≥44 mm (vs. <36 mm), and creatinine clearance <50 mL/min were independently associated with AE incidences, but not with recurrences. CONCLUSIONS: This study disclosed different determinants of post-ablation recurrence and AEs. Female sex, persistent AF, and enlarged LAd were determinants of post-ablation recurrence, whereas an old age, comorbidities, and LV and renal dysfunction rather than post-ablation recurrence were AEs determinants. These findings will help determine ablation indications and post-ablation management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
8.
Heart Vessels ; 37(2): 327-336, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524497

RESUMO

The impact of catheter ablation for atrial fibrillation (AF) on cardiovascular events and mortality is controversial. We investigated the impact of sinus rhythm maintenance on major adverse cardiac and cerebrovascular events after AF ablation from a Japanese multicenter cohort of AF ablation. We investigated 3326 consecutive patients (25.8% female, mean age 63.3 ± 10.3 years) who underwent catheter ablation for AF from the atrial fibrillation registry to follow the long-term outcomes and use of anti coagulants after ablation (AF frontier ablation registry). The primary endpoint was a composite of stroke, transient ischemic attack, cardiovascular events, and all-cause death. During a mean follow-up of 24.0 months, 2339 (70.3%) patients were free from AF after catheter ablation, and the primary composite endpoint occurred in 144 (4.3%) patients. The AF nonrecurrence group had a significantly lower incidence of the primary endpoint (1.8 per 100 person-years) compared with the AF recurrence group (3.0 per 100 person-years, p = 0.003). The multivariate analysis revealed that freedom from AF (hazard ratio 0.61, 95% confidence interval 0.44-0.86, p = 0.005) was independently associated with the incidence of the composite event. In the multicenter cohort of AF ablation, sinus rhythm maintenance after catheter ablation was independently associated with lower rates of major adverse cardiac and cerebrovascular events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(4): 1035-1043, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33533109

RESUMO

BACKGROUND: Inflammation, such as that associated with intermediate CD14++ CD16+ monocytes and atrial structural remodeling (SRM), may be important in the recurrence of atrial fibrillation (AF) after catheter ablation. However, the relationship between the intermediate CD14++ CD16+ monocytes, SRM, and AF recurrence is unclear. METHODS: Twenty-four patients with AF were enrolled. The proportion of intermediate monocytes (PIM) was assessed before ablation by flow cytometry. As a surrogate marker of SRM, the volume ratio (VR) of signal intensity greater than 1 standard deviation on late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) was calculated. We investigated whether PIM correlated with SRM on LGE-MRI and determined the optimal cutoff value for predicting AF recurrence. RESULTS: Univariate analysis revealed positive correlations between PIM and BNP with SRM (PIM: r = .593, p = .002; BNP: r = .567, p = .004). Multivariable analysis revealed that PIM was independently associated with VR on LGE-MRI (ß = .522; p = .033). The finding of an area under the receiver operating characteristic curve of 0.750 revealed that a VR ≥ 13.3% on LGE-MRI as the optimal cutoff value to predict AF recurrence with 80% sensitivity and 71% specificity, which was associated with PIM ≥ 10.0%. CONCLUSION: Intermediate monocytes were significantly positively correlated with SRM. PIM ≥ 10% was associated with a VR ≥ 13.3% on LGE-MRI, which predicted AF recurrence after catheter ablation.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Monócitos , Recidiva
10.
J Cardiovasc Electrophysiol ; 32(4): 1014-1023, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33527586

RESUMO

BACKGROUND: A computer simulation model has demonstrated that atrial fibrillation (AF) driver can be attached to heterogeneous fibrosis assessed by late gadolinium enhancement magnetic resonance imaging (LGE-MRI). However, it has not been well elucidated in patients with persistent AF. The aim of this study was to investigate whether radiofrequency (RF) applications in the fragmented LGE area (FLA) could terminate AF or convert it to atrial tachycardia (AT) and improve the rhythm outcome. METHODS: A total of 31 consecutive persistent AF patients with FLAs were enrolled (FLA ablation group, mean age: 69 ± 8 years, mean left atrial diameter: 42 ± 6 mm). A favorable response was defined as direct AF termination or AT conversion during RF applications at the FLA. The rhythm outcome was compared between the FLA ablation group and FLA burden-matched pulmonary vein isolation (PVI) group. RESULTS: Favorable responses were found in 15 (48%) of 31 patients in the FLA group (AF termination in seven, AT conversion in eight patients), but not in the PVI group. AF recurrence at 12 months follow-up was significantly less in the FLA ablation group than in the PVI group (4 [13%] vs. 12 [39%] of 31 patients, log-rank p = .023). In patients with a favorable response, AT recurred in 1 (7%) of 15 patients, but AF did not. CONCLUSIONS: FLA ablation could terminate AF or convert it to AT in half of the patients. No AF recurrence was documented in patients with a favorable response.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Simulação por Computador , Meios de Contraste , Estudos de Viabilidade , Gadolínio , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 32(4): 1005-1013, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33556994

RESUMO

BACKGROUND: A computational model demonstrated that atrial fibrillation (AF) rotors could be distributed in patchy late-gadolinium enhancement (LGE) areas and play an important role in AF drivers. However, this was not validated in humans. OBJECTIVE: The purpose of this study was to evaluate the LGE properties of AF rotors in patients with persistent AF. METHODS: A total of 287 segments in 15 patients with persistent AF (long-standing persistent AF in 9 patients) that underwent AF ablation were assessed. Non-passively activated areas (NPAs), where rotational activation (AF rotor) was frequently observed, were detected by the novel real-time phase mapping (ExTRa Mapping). The properties of the LGE areas were assessed using the LGE heterogeneity and the density which was evaluated by the entropy (LGE-entropy) and the volume ratio of the enhancement voxel (LGE-volume ratio), respectively. RESULTS: NPAs were found in 61 (21%) of 287 segments and were mostly found around the pulmonary vein antrum. A receiver operating characteristic curve analysis yielded an optimal cutoff value of 5.7% and 10% for the LGE-entropy and LGE-volume ratio, respectively. The incidence of NPAs was significantly higher at segments with an LGE-entropy of >5.7 and LGE-volume ratio of >10% than at the other segments (38 [30%] of 126 vs. 23 [14%] of 161 segments; p = .001). No NPAs were found at segments with an LGE-volume ratio of >50% regardless of the LGE-entropy. Of five patients with AF recurrence, NPAs outside the PV antrum were not ablated in three patients and the remaining NPAs were ablated, but their LGE-entropy and LGE-volume ratio were low. CONCLUSION: AF rotors are mostly distributed in relatively weak and much more heterogenous LGE areas.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética
12.
Circ J ; 85(3): 264-271, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33431721

RESUMO

BACKGROUND: Coronary artery spasms (CASs), which can cause angina attacks and sudden death, have been recently reported during catheter ablation. The aim of the present study was to report the incidence, characteristics, and prognosis of CASs related to atrial fibrillation (AF) ablation procedures.Methods and Results:The AF ablation records of 22,232 patients treated in 15 Japanese hospitals were reviewed. CASs associated with AF ablation occurred in 42 of 22,232 patients (0.19%). CASs occurred during ablation energy applications in 21 patients (50%). CASs also occurred before ablation in 9 patients (21%) and after ablation in 12 patients (29%). The initial change in the electrocardiogram was ST-segment elevation in the inferior leads in 33 patients (79%). Emergency coronary angiography revealed coronary artery stenosis and occlusions, which were relieved by nitrate administration. No air bubbles were observed. A comparison of the incidence of CASs during pulmonary vein isolation between the different ablation energy sources revealed a significantly higher incidence with cryoballoon ablation (11/3,288; 0.34%) than with radiofrequency catheter, hot balloon, or laser balloon ablation (8/18,596 [0.04%], 0/237 [0%], and 0/111 [0%], respectively; P<0.001). CASs most often occurred during ablation of the left superior pulmonary vein. All patients recovered without sequelae. CONCLUSIONS: CASs related to AF ablation are rare, but should be considered as a dangerous complication that can occur anytime during the periprocedural period.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Vasoespasmo Coronário , Veias Pulmonares , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Vasoespasmo Coronário/epidemiologia , Vasoespasmo Coronário/etiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Incidência , Veias Pulmonares/cirurgia , Espasmo , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 44(11): 1874-1883, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34455601

RESUMO

BACKGROUND: A substantial number of patients with shock devices (implantable cardioverter defibrillators [ICDs] or ICDs with resynchronization [CRTDs]) experience psychological distress. OBJECTIVE: We investigated the device nurse telephone intervention's effect on improving the patient's adaptation to shock devices, quality of life (QOL), and anxiety in the remote monitoring era. METHODS: The patient's adaptation to the device, health-related QOL, and anxiety were investigated by the modified Implanted Devices Adjustment-Japan score (IDAS), Short Form-36, and State-Trait Anxiety Inventory (STAI) before and 1-year after the device nurse telephone intervention, performed every 3 months. A total of 95 patients (median age 69 years and 25 females) participated. Sixty patients had ICDs and 35 CRTDs. Structural heart disease was observed in 72 patients, and idiopathic ventricular arrhythmias in the others. The mean left ventricular ejection fraction was 46% ± 15%. The median duration since the device implantation was 5.2 years. RESULTS: The total IDAS score significantly improved from 28.42 ± 7.11 at baseline to 26.77 ± 7.68 (p = 0.0076) at 1 year. Both the state and trait anxiety significantly improved (from 38.9 ± 9.6 to 35.3 ± 9.0 [<0.0001] and 38.8 ± 10.3 to 36.2±9.8 [p = 0.0044], respectively). The prevalence of patients with a state and trait anxiety of more than 40 decreased from 44 (46%) and 38 (40%) patients before the study to 27 (28 %) and 32 (34 %) at 1 year. The SF-36 mental component summary score significantly increased (50.8 ± 8.3 at baseline to 53.1 ± 7.7 at 1 year, p = 0.0031). CONCLUSIONS: The device nurse intervention facilitated the patient's adaptation to the shock device, increased the health-related QOL, and reduced the patient's anxiety.


Assuntos
Adaptação Fisiológica , Terapia de Ressincronização Cardíaca/enfermagem , Desfibriladores Implantáveis , Qualidade de Vida , Tecnologia de Sensoriamento Remoto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Heart Vessels ; 36(4): 549-560, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33236221

RESUMO

Whether ablation for atrial fibrillation (AF) is, in terms of clinical outcomes, beneficial for Japanese patients has not been clarified. Drawing data from 2 Japanese AF registries (AF Frontier Ablation Registry and SAKURA AF Registry), we compared the incidence of clinically relevant events (CREs), including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular events, and death, between patients who underwent ablation (n = 3451) and those who did not (n = 2930). We also compared propensity-score matched patients (n = 1414 in each group). In propensity-scored patients who underwent ablation and those who did not, mean follow-up times were 27.2 and 35.8 months, respectively. Annualized rates for stroke/TIA (1.04 vs. 1.06%), major bleeding (1.44 vs. 1.20%), cardiovascular events (2.15 vs. 2.49%) were similar (P = 0.96, 0.39, and 0.35, respectively), but annualized death rates were lower in the ablation group than in the non-ablation group (0.75 vs.1.28%, P = 0.028). After multivariate adjustment, the risk of CREs was statistically equivalent between the ablation and non-ablation groups (hazard ratio [HR] 0.89, 95% confidence interval [CI] 0.71-1.11), but it was significantly low among patients who underwent ablation for paroxysmal AF (HR 0.68 [vs. persistent AF], 95% CI 0.49-0.94) and had a CHA2DS2-VASc score < 3 (HR 0.66 [vs. CHA2DS2-VASc score ≥ 3], 95% CI 0.43-0.98]). The 2-year risk reduction achieved by ablation may be small among Japanese patients, but AF ablation may benefit those with paroxysmal AF and a CHA2DS2-VASc score < 3.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Pontuação de Propensão , Sistema de Registros , Medição de Risco/métodos , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 31(1): 196-204, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31750592

RESUMO

INTRODUCTION: The ablation index (AI) and lesion size index (LSI) are novel markers for predicting the ablation lesion quality, however, collateral damage is still a concern. This study aimed to compare the lesion characteristics and tissue temperature profiles between 20 W (20 Ws) and 40 W (40 Ws) ablation settings under the same AI and LSI. METHODS: An ex vivo model consisting of swine myocardium (5-6 mm thickness) in a circulating, warmed saline bath was used. Twenty-one tissue temperature electrodes were used. Radiofrequency applications with different power settings were performed with a 10 to 12 g contact force until the AI and LSI reached 350 and 4.5, respectively. RESULTS: A total of 120 radiofrequency (RF) applications and 2520 tissue temperature profiles were analyzed. The speed of the tissue temperature rise with 40 Ws was significantly faster than that with 20 Ws. However, the maximum tissue temperature did not significantly differ between 20 and 40 Ws with the same AI (44.6°C ± 3.9°C vs 45.1°C ± 6.4°C, P = .73), and was significantly lower for 40 Ws with the same LSI (42.8°C ± 3.4°C vs 40.0°C ± 3.4°C, P = .003). For both the AI and LSI, the number of electrodes exhibiting high temperatures (≥39°C) was significantly larger and the duration of high tissue temperatures was significantly longer with 20 Ws. The thermal latency with 40 Ws was greater. CONCLUSIONS: Although the targeted AI and LSI were the same for both 20 and 40 Ws, the tissue temperature profiles differed greatly depending on the RF power setting. A high power setting based on the AI and LSI may reduce the collateral thermal damage.


Assuntos
Ablação por Cateter , Temperatura Alta , Miocárdio/patologia , Animais , Ablação por Cateter/efeitos adversos , Temperatura Alta/efeitos adversos , Técnicas In Vitro , Sus scrofa , Fatores de Tempo
16.
J Cardiovasc Electrophysiol ; 31(10): 2572-2581, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648326

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are characterized as a wider and more continuous than that after conventional radiofrequency catheter ablation (RFCA) without the contact force (CF)-sensing technology. However, the impact on the lesion characteristics of ablation with a CF-sensing catheter has not been well discussed. We sought to assess the lesions using late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) and to compare the differences between the two groups (CB group vs. RF group). METHODS: A total of 30 consecutive patients who underwent PVI were enrolled (CB group, 18; RF group, 12). The RF applications were delivered with a target lesion size index (LSI) of 5. The PVI lesions were assessed by LGE-MRI 3 months after the PVI. The region around the PV was divided into eight segments: roof, anterior-superior, anterior carina, anterior inferior, bottom, posterior inferior, posterior carina, and posterior superior segment. The lesion width and visual gap of each segment were compared between the two groups. The visual gaps were defined as no-enhancement site of >4 mm. RESULTS: The mean LSI was 4.7 ± 0.7. The lesion width was significantly wider but the visual gaps were more frequently documented at the bottom segment of right PV in the CBA group (lesion width: 8.1 ± 2.2 vs. 6.3 ± 2.2 mm; p = .032; visual gap at the bottom segment or right PV: 39% vs. 0%; p = .016). CONCLUSIONS: The PVI lesion was wider after CBA, while the visual gaps were fewer after RFCA with a CF-sensing catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Meios de Contraste , Criocirurgia/efeitos adversos , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos , Resultado do Tratamento
17.
Heart Vessels ; 35(12): 1717-1726, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32524234

RESUMO

Inflammation has been suggested to play a key role in the pathogenesis of atrial fibrillation (AF). Our hypothesis was that this inflammation, mediated by intermediate monocytes and toll-like receptor 4 (TLR4), causes the formation and expansion of low-voltage zones (LVZs). Prior to ablation, the monocyte subsets of 78 AF patients and TLR4 expression of 66 AF patients were analyzed via a flow cytometric analysis. Based on the CD14/CD16 expression, the monocytes were divided into three subsets: classical, intermediate, and non-classical. At the beginning of the ablation session, voltage mapping was performed. LVZs were defined as all bipolar electrogram amplitudes of < 0.5 mV. Correlations between the flow cytometric analysis results and presence of LVZs, as well as the total area of the LVZ, were examined. Patients with LVZs clearly had a higher proportion of intermediate monocytes (10.0 ± 3.6% vs. 7.2 ± 2.7%, p < 0.001) than those without LVZs. TLR4 was much more frequently expressed in the intermediate monocytes than other two monocyte subsets (p < 0.001). Moreover, the TLR4 expression level in intermediate monocytes correlated positively with the total area of the LVZs (r = 0.267, p = 0.030), especially in patients with paroxysmal AF (r = 0.365, p = 0.015). The intermediate monocytes and TLR4 expression positively correlated with LVZs in AF patients.


Assuntos
Potenciais de Ação , Fibrilação Atrial/sangue , Frequência Cardíaca , Mediadores da Inflamação/sangue , Inflamação/sangue , Monócitos/metabolismo , Receptor 4 Toll-Like/sangue , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Feminino , Proteínas Ligadas por GPI/sangue , Humanos , Inflamação/diagnóstico , Receptores de Lipopolissacarídeos/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Receptores de IgG/sangue
18.
Int Heart J ; 61(6): 1165-1173, 2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33191353

RESUMO

Direct oral anticoagulants (DOACs) are sometimes prescribed at off-label under-doses for patients who have undergone ablation for atrial fibrillation (AF). This practice may be an attempt to balance the risk of bleeding against that of stroke or AF recurrence.We examined outcomes of 1163 patients who continued use of a DOAC after ablation. The patients were enrolled in a large (3530 patients) multicenter registry in Japan. The study patients were classified as 749 (64.4%) appropriate standard-dose DOAC users, 216 (18.6%) off-label under-dose DOAC users, and 198 (17.0%) appropriate low-dose DOAC users.Age and CHA2DS2-VASc scores differed significantly between DOAC dosing regimens, with patients given an appropriate standard-dose being significantly younger (63.3 ± 9.4 versus 64.8 ± 9.5 versus 73.2 ± 6.8 years, P < 0.0001) and lower (2.1 ± 1.5 versus 2.4 ± 1.6 versus 3.4 ± 1.4, P < 0.0001) than those given an off-label under-dose or an appropriate low-dose. During the median 19.0-month follow-up period, the AF recurrence rate was similar between the appropriate standard-dose and off-label under-dose groups but relatively low in the appropriate low-dose group (42.5% versus 41.2% versus 35.4%, P = 0.08). Annualized rates of thromboembolic events, major bleeding, and death from any cause were 0.47%, 0.70%, and 0.23% in the off-label under-dose group, while those rates were 0.74%, 0.73%, and 0.65% in the appropriate standard-dose, and 1.58%, 2.12%, and 1.57% in the appropriate low-dose groups.In conclusion, the clinical adverse event rates for patients on an off-label under-dose DOAC regimen after ablation, predicated on careful patient evaluations, was not high as seen with that of patients on a standard DOAC dosing regimen.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Inibidores do Fator Xa/administração & dosagem , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Hemorragia/epidemiologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade , Uso Off-Label , Cuidados Pós-Operatórios , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia
19.
J Cardiovasc Electrophysiol ; 30(10): 1830-1840, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31310389

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are wide and continuous, however, the distribution can depend on the pulmonary vein (PV) size. We sought to assess the relationship between the lesion distribution and PV size after CBA and hotballoon ablation (HBA). METHODS AND RESULTS: A total of 80 consecutive patients who underwent PVI were enrolled (40 with CBA). The lesions were visualized by late-gadolinium enhancement magnetic resonance imaging. The lesion width, lesion gaps, and distance from the PV ostium (PVos) to distal lesion edge (DLE) were assessed. If the DLE extended inside the PV, the value was expressed as a negative value. Although the lesion width was significantly wider in the CB group (7.8 ± 2.0 vs 4.9 ± 1.0 mm, P < .001), the number of lesion gaps was significantly less in the HB group (2.9 ± 2.4 vs 1.3 ± 1.4 gaps, P = .001). The distance from the PVos to DLE was a negative value in both groups, but the impact was significantly greater (-1.5 ± 1.8 vs -0.2 ± 1.2 mm, P < .001) and negatively correlated with PV size in the CB group, but not in HB group (r = -0.27, P = .007). The AF recurrence 12 months after the procedure did not differ (5 [12.5%] of 40 in the CB group vs 4 [10%] of 40 in the HB group, P = .695). CONCLUSIONS: The PVI lesions after HBA were characterized by (a) narrower, but (b) more continuous, (c) smaller lesion inside the PV, and (d) irrespective of PV size as compared to that after CBA.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Criocirurgia , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Circ J ; 83(12): 2418-2427, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31619591

RESUMO

BACKGROUND: The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status. CONCLUSIONS: Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ablação por Cateter , Ataque Isquêmico Transitório/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Esquema de Medicação , Feminino , Hemorragia/induzido quimicamente , Humanos , Incidência , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/mortalidade , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA