Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 99(1): E31-E37, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34676958

RESUMO

BACKGROUND: Selection of appropriate patients for transcatheter aortic valve implantation (TAVI) can be challenging. Many factors can influence post-procedure outcomes. Traditional surgical scoring systems do not discriminate effectively. Medical parameters and functional indices can characterize mortality risk. Mobility is an important predictive functional index but is largely defined using subjective criteria. AIM: To describe the relationship between mobility, objectively defined by the requirement for gait aids to ambulate, and all-cause 30-day and long-term mortality in patients undergoing TAVI. METHODS: Mobility aid use was assessed in 1444 consecutive patients undergoing TAVI in a single center. Patients were categorized into "unaided," "1-stick," and "higher aid" groups based on the Brighton Mobility Index. Mortality tracking was obtained via the NHS Spine Portal in February 2021. RESULTS: Patients were aged 82 (IQR 78-86). 66% of patients walked unaided, 26% walked with 1 stick, and 8% required more assistance (e.g., 2 sticks, a Rollator, a Zimmer frame, or a wheelchair). Overall 30-day mortality for the whole cohort was 3.5%; 1-year mortality was 12.2%. Mobility was a significant predictor of 30-day mortality (p = 0.025). Use of a higher aid was associated with a mortality odds ratio of 2.83 (95% CI: 1.39-5.74). Mobility was also a significant predictor of long-term mortality (p < 0.001). Odds ratios for 1-stick and higher aid groups were 1.45 (95% CI: 1.21-1.72) and 2.01 (95% CI: 1.55-2.60), respectively. CONCLUSION: Objective assessment of mobility by gait aid use predicts both short and long-term survival in patients undergoing TAVI. Increased dependence on mobility aids is associated with a worse prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fluoroscopia , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
J Invasive Cardiol ; 33(10): E761-E768, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34521771

RESUMO

OBJECTIVES: To assess the impact of balloon use for predilation, valve implantation, or postdilation on in-hospital mortality among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR utilizes self-expanding, mechanically expanding, or balloon-expandable valves. Balloon inflation is inherent to deployment of balloon-expandable valves. Balloons may additionally be used with all valve types for pre- and postdilation. The relationships between valve mechanism, balloon use, and in-hospital mortality are not fully characterized. METHODS: Prospective data were collected on 4063 patients undergoing TAVR for aortic stenosis at 4 high-volume centers in the United Kingdom. In-hospital mortality was analyzed according to valve expansion mechanism, use of balloons for pre- and postdilation, and specific cause of death. RESULTS: Mean patient age was 83 ± 8 years. Implanted valves were self expanding (n = 2241; 55%), mechanically expanding (n = 1092; 27%), or balloon expandable (n = 727; 18%). In-hospital death occurred in 66 cases (1.6%). Thirty-six deaths (54.5%) were classified as implantation-related mortalities, with rates of 0.8%, 0.5%, and 1.7% (P=.04) among self-expanding, mechanically expanding, and balloon-expandable technologies, respectively. Patients who underwent balloon inflation at any stage of their procedure (n = 2556; 63%) had significantly higher implantation-related mortality than those who did not (1.3% vs 0.3%, respectively; P<.01). Balloon-expandable valve procedures were associated with significantly higher all-cause mortality (2.6% vs 1.4%; P=.02) and implantation-related mortality (1.7% vs 0.7%; P=.02) than non-balloon-expandable valve procedures. Balloon-related complications accounted for 18 cases (26%) of total in-hospital mortality, including all 12 cases (17.4%) of annular rupture and 5 cases (7.2%) of coronary occlusion. CONCLUSIONS: Balloon use for predilation, valve implantation, or postdilation was associated with an increased mortality risk. Balloon-related complications were the largest contributor to in-hospital mortality, comprising all cases of annular rupture and the majority of coronary occlusion cases.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Mortalidade Hospitalar , Humanos , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA