Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur J Orthop Surg Traumatol ; 34(2): 853-862, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37747556

RESUMO

PURPOSE: The purpose of this cadaver study was to examine the surface morphology of the osteochondral grafts harvested from the femoral condyles using the free-hand graft harvesting technique. MATERIALS AND METHODS: One hundred osteochondral grafts were harvested with 6.5 mm chisels at ten different donor sites using the free-hand technique in five paired knee specimens (Mean age: 56.4 years). The cartilage and subchondral bone surface angles were measured through multiplanar reconstruction computerized tomography examination. The cartilage thickness was measured with a MicroScribe G2X digitizer with an accuracy of 0.02 mm. An acceptable congruity could be obtained when these plugs were transferred to a perpendicular socket (articular step-off of less than 1 mm and 0.5 mm) was evaluated. RESULTS: Four plugs were damaged or broken during harvesting due to technical difficulties; thus remaining 96 plugs were analyzed. The cartilage thickness varied between 1.36 mm and 3.26 mm across the donor sites. The cartilage was the thinnest in the medial intercondylar notch and thickest in the lateral supracondylar notch. Twenty of ninety-six plugs (20.8%) had unacceptable cartilage surface inclination according to the > 0.5 mm protrusion criteria. Of these plugs, 14 were harvested from the lateral intercondylar notch, whereas five of 96 plugs (5.2%) had unacceptable cartilage surface inclination according to the > 1 mm protrusion criteria. Of these plugs, all were harvested from the lateral intercondylar notch. CONCLUSIONS: High rates of unacceptable plugs (up to 100%) might be harvested from the lateral intercondylar notch. In large chondral lesions that require multiple plugs, lateral and medial supracondylar ridges were the best donor sites for perpendicular plug harvesting, whereas lateral intercondylar notch should be avoided.


Assuntos
Cartilagem Articular , Humanos , Pessoa de Meia-Idade , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/cirurgia , Transplante Ósseo/métodos , Transplante Autólogo , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Articulação do Joelho/patologia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/anatomia & histologia , Cadáver
2.
Arch Orthop Trauma Surg ; 143(6): 3309-3317, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36018367

RESUMO

PURPOSE: The purpose of this randomized controlled study was to examine the effect of sealing the intramedullary canal with a bone or cement plug or leaving it empty on postoperative bleeding and pain MATERIALS AND METHODS: A total of 120 patients with knee osteoarthritis who underwent unilateral TKA participated in the trial and were assigned to one of three groups. The femoral canal was sealed with an autogenous bone plug (Group I) or cement plug (Group II), or it was left open (Group III). Estimated blood loss, Hemoglobin decline, bleeding into the drain, and postoperative pain w compared between groups. RESULTS: Six patients were excluded due to various reasons, and the remaining 114 patients were included in the final analysis. There were no significant variations in baseline clinical characteristics between the three groups (p > 0.05). Hemoglobin reduction between preoperative and 72 h after the surgery (p: 0.034) and estimated blood loss (p: 0.003) were significantly different between groups. The cement plug group showed the least bleeding. Although there was a significant difference between the cement and empty canal groups (p: 0.03 and p: 0.002, respectively), the difference between the cement and bone groups was similar regarding both hemoglobin reduction and estimated blood loss. The blood volume in the suction drain (p: 0.598) and transfusion rate (p: 0.087) were similar between the groups. VAS at the 12 h after the surgery was similarly high in each group (p: 0.676). It declined at 36 h after surgery, but no significant difference was determined between groups (p: 0.815). CONCLUSIONS: This study showed that estimated blood loss and hemoglobin reduction were significantly lower in the cement plug group than in the empty canal group. But bone plug group did not show any difference with both empty canal and cement plug groups. Sealing the IM canal or leaving it open did not change the bleeding into the drain, transfusion rate, and postoperative pain between groups. Based on these findings, sealing the IM canal with a cement plug might be recommended to diminish bleeding during TKA despite similar transfusion rates. LEVEL OF EVIDENCE: Level I, randomized controlled trial.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Hemorragia Pós-Operatória/prevenção & controle , Osteoartrite do Joelho/cirurgia , Dor Pós-Operatória/cirurgia , Hemoglobinas
3.
Arch Orthop Trauma Surg ; 143(11): 6675-6684, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37453933

RESUMO

OBJECTIVE: Peroneus longus tendon (PLT) has become a reliable autologous graft option for various ligament reconstructions. But there are potential risks and complications associated with its use as a graft. This retrospective study aimed to examine the complications and donor site morbidity following PLT harvesting. PATIENTS AND METHODS: A retrospective review was performed on an institutional digital patient database, and all patients who underwent ligament reconstruction using PLT autograft were identified. Intraoperative, early, and late complications were reviewed using digital patient notes and patients underwent a complete physical examination during their final follow-up. Ankle function was assessed using the AOFAS score, and manual ankle muscle testing was performed on both sides. Sural nerve iatrogenic injury was evaluated with a dermatomal light touch examination. Cosmetic satisfaction due to incision scar and footwear complaints were also assessed. RESULTS: 82 patients (74 male, eight female) with a mean age of 31.9 ± 10.4 years (range, 16-66) were included in the final analysis. The mean follow-up time was 46.6 ± 30.3 months (range, 6-109). The mean AOFAS score for the donor side was 98.7 ± 3.3 (range, 87-100), and the contralateral side score was 100, with manual muscle testing graded as 5 in all movements and similar to the contralateral side. Fifteen patients (18.3%) had hypoesthesia over the dorsolateral aspect of the foot distal to the incision scar, two patients (2.4%) had hyperalgesia over the distal incision scar, and one patient (1.2%) had mild ankle instability. There were two cases (2.4%) of compartment syndrome, both of which were treated with fasciotomy and had complete regression of symptoms after 5 days. One patient (1.2%) had a transient peroneal nerve injury and foot drop that resolved in the sixth month. CONCLUSIONS: The results of this retrospective study suggest that harvesting the PLT is associated with a high rate of complications and donor site morbidity. The most common complication was hypoesthesia around the lateral side of the foot, although the ankle functions were not affected significantly. Two cases of compartment syndrome and one transient peroneal nerve injury were observed. Care should be taken while harvesting PLT autograft, and it should be kept in mind that peroneal nerve injury might occur. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Cicatriz , Síndromes Compartimentais , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Estudos Retrospectivos , Hipestesia , Tendões/transplante
4.
Chin J Traumatol ; 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38065705

RESUMO

PURPOSE: The purpose of this cadaveric study was to compare the volume and weight of bone graft harvested using the curettage vs. the trephination technique from the anterior iliac crest. METHODS: Embalmed cadavers were studied in this experimental research. The right hemipelvis of each cadaver was used for the trephine bone harvesting technique, whereas the left hemipelvis was used for the conventional curettage technique. The weight and the volume of the harvested bone were measured and statistically compared between the 2 sides. The Wilcoxon Signed-Rank test was employed to compare the graft volume and weight obtained from the right and left sides of the hemipelvis. RESULTS: Ten embalmed adult cadavers were used in this study. All subjects were Caucasian males with a mean age of 59.8 years (range 44 - 73 years) at the time of death. A total of 81 cylindrical bone grafts were harvested from the right iliac crest. In 9 out of 81 (11.1 %), the cortex of the ilium was penetrated by the chisel. The mean weight of the bone graft harvested with the trephine technique (26.97 ± 2.32) g was heavier than the curettage technique (23.74 ± 2.09) g (p = 0.007). Similarly, the volume of the bone graft was higher in the trephine technique (8.40 ± 0.84) cm3 compared to the curettage technique (6.60 ± 1.26) cm3 (p = 0.011). The trephination technique lasted a mean of (12.76 ± 1.87) min (range 10.30-16.10 min), while the curettage technique lasted a mean of (14.53 ± 0.89) min (range 13.50-16.00 min) (p = 0.028). CONCLUSION: Harvesting anterior iliac crest bone graft with the trephine technique provides a higher bone volume and weight than the conventional curettage technique. The trephine technique might be advocated over the curettage technique, especially when a large amount of autologous bone graft is required. However, a meticulous harvesting technique should be followed to prevent complications, particularly the three-dimensional anatomy should be kept in mind, and the depth of trephination should be well-controlled. CLINICAL TRIAL REGISTRATION: Institutional Review Board registration: 2022/499.

5.
J Orthop Traumatol ; 24(1): 30, 2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37358664

RESUMO

BACKGROUND: Conventionally, two 4.5 mm cortical screws inserted toward the posterior tibial cortex are usually advocated for the fixation of Fulkerson osteotomy. This finite element analysis aimed to compare the biomechanical behavior of four different screw configurations to fix the Fulkerson osteotomy. MATERIALS AND METHODS: Fulkerson osteotomy was modeled using computerized tomography (CT) data of a patient with patellofemoral instability and fixed with four different screw configurations using two 4.5 mm cortical screws in the axial plane. The configurations were as follows: (1) two screws perpendicular to the osteotomy plane, (2) two screws perpendicular to the posterior cortex of the tibia, (3) the upper screw perpendicular to the osteotomy plane, but the lower screw is perpendicular to the posterior cortex of the tibia, and (4) the reverse position of the screw configuration in the third scenario. Gap formation, sliding, displacement, frictional stress, and deformation of the components were calculated and reported. RESULTS: The osteotomy fragment moved superiorly after loading the models with 1654 N patellar tendon traction force. Since the proximal cut is sloped (bevel-cut osteotomy), the osteotomy fragment slid and rested on the upper tibial surface. Afterward, the upper surface of the osteotomy fragment acted as a fulcrum, and the distal part of the fragment began to separate from the tibia while the screws resisted the displacement. The resultant total displacement was 0.319 mm, 0.307 mm, 0.333 mm, and 0.245 mm from the first scenario to the fourth scenario, respectively. The minimum displacement was detected in the fourth scenario (upper screw perpendicular to the osteotomy plane and lower screw perpendicular to the posterior tibial cortex). Maximum frictional stress and maximum pressure between components on both surfaces were highest in the first scenario (both screws perpendicular to the osteotomy plane). CONCLUSIONS: A divergent screw configuration in which the upper screw is inserted perpendicular to the osteotomy plane and the lower screw is inserted perpendicular to the posterior tibial cortex might be a better option for the fixation of Fulkerson osteotomy. Level of evidence Level V, mechanism-based reasoning.


Assuntos
Parafusos Ósseos , Tíbia , Humanos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Tíbia/cirurgia , Osteotomia/métodos , Fixação Interna de Fraturas/métodos
6.
J Foot Ankle Surg ; 55(5): 971-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27289216

RESUMO

An ideal surgical treatment of acute Achilles tendon rupture includes restoring the original length of the tendon, minimizing possible adhesions with the surrounding tissues, minimizing the risk of repeat rupture, alleviating wound problems, and providing an acceptable cosmetic outcome. In the mini-open repair technique, unlike the percutaneous repair technique, the quality of the tenodesis can be visualized without disturbing the healing potential of the surrounding tissues, thus minimizing wound problems. The purpose of the present study was to assess the long-term results of the mini-open repair technique in patients with acute Achilles tendon rupture. A total of 20 consecutive patients with acute Achilles tendon rupture, admitted to our inpatient clinic from October 2003 to March 2008, were included in the present study. The patients underwent Achilles tenodesis with the mini-open repair technique, and each patient was followed up for 5 years. The study was completed in April 2013. The surgical procedure was performed with the assistance of a device designed in our orthosis laboratories, similarly to that defined by Assal et al. Of the 20 patients, 18 were male and 2 were female. Their mean age was 39.3 (range 21 to 55) years. The Achilles tendon rupture was located on the left side in 15 patients (75%) and on the right side in 5 patients (25%). The mean follow-up duration was 58.5 (range 18 to 60) months and no complications occurred during the follow-up period, including repeat rupture, wound site infection, and sural nerve injury. The mean American Orthopaedic Foot and Ankle Society scale score for the patients was 99.2 (range 94 to 100) points at the final follow-up visit. All our patients were able to return to work and sporting activities. According to the Trillat scores, the outcome was excellent in 19 patients and good in 1 patient at the 18th postoperative month. No complaint, such as pain or loss of function, that might have a negative effect on the patients' business or social life was detected in 18 patients who were assessed at 5 years after surgery; 2 patients could not be reached at 5 years. In conclusion, as a technique combining percutaneous and open surgical techniques, mini-open repair of Achilles tendon rupture allows a satisfactory end-to-end approximation of the tendon just in the open surgery and provides the wound healing advantages of percutaneous surgery.


Assuntos
Tendão do Calcâneo/lesões , Procedimentos Ortopédicos/métodos , Traumatismos dos Tendões/cirurgia , Tendão do Calcâneo/cirurgia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Ruptura/cirurgia , Resultado do Tratamento , Adulto Jovem
7.
J Am Podiatr Med Assoc ; : 1-14, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729743

RESUMO

BACKGROUND: An abnormal hallux interphalangeal angle may be an important risk factor for the recurrence of ingrown toenails. METHODS: In this study, sixty pediatric patients who underwent surgery for an ingrown toenail were evaluated retrospectively in terms of recurrence. The patients were divided into two groups. Group 1 included 30 patients (22 male, 8 female) with hallux valgus interphalangeal deformity. Group 2 included 30 patients (20 male, 10 female) without toe deformity. RESULTS: The mean age was 12.8±1.42 years and 12.5±1.45 years for patients in Group 1 and in Group 2 respectively. There was no statistically significant difference between the patient and control group in terms of age and gender (p>0.05). The mean follow-up time was 40 months. We observed recurrence in six patients (20%) in Group 1 and in 2 patients (6.6%) in Group 2. CONCLUSION: We concluded that the recurrence of an ingrown toenail may be associated with increased hallux interphalangeal angle in pediatric patients. Factors related to the hallux interphalangeal angle abnormality, which increases the risk of ingrown toenails, also increase the recurrence rate in these patients. Therefore, it is surmised that hallux valgus interphalangeal deformity should be evaluated before surgery, and patients and their families should be informed about the risk of increased recurrence.

8.
Indian J Orthop ; 57(6): 838-846, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37214361

RESUMO

Purpose: This study aimed to investigate whether the Akagi line is a reliable anatomic landmark for adjusting the rotational axis of the tibial component in patients with patellofemoral (PF) malalignment. Materials and methods: This retrospective case-control study included 86 patients with PF instability and 129 controls. On the superimposed axial CT images, TT-TG, TT-PCL, nTT-TG, nTT-PCL, knee joint rotation, and the angle between the Akagi line and surgical transepicondylar axis (Akagi/sTEA angle) were measured. In addition, a modified Akagi line, drawn 1 cm medial to the patellar tendon attachment, was defined, and the angle between the new Akagi line and sTEA (mAkagi/sTEA angle) was also measured and compared between groups. Results: There were 86 patients (47 females, 39 males) in the case group and 129 patients (56 females, 73 males) in the control group with a mean age of 35.7 ± 17.9 years and 41.1 ± 18.8 years, respectively (p < 0.001). Radiologic variables of PF alignment (TT-TG, TT-PCL, nTT-TG, nTT-PCL, and knee joint rotation) were significantly abnormal in the case group (p < 0.001 for all variables). The Akagi/sTEA angle was significantly higher in the case group, resulting in 89.5% external malrotation of the tibial component (> 10°). However, the tibial component was 96.5% aligned correctly (between 10° external and 3° internal rotation) in the control group. Using the modified Akagi line significantly improved the rotational alignment, and normal tibial rotation increased to 93.3% of the case group. The Akagi/sTEA angle strongly correlated with the knee rotation (rho: 0.735, p: 0.001), TT-TG (rho: 0.715, p: 0.001) and nTT-TG (rho: 0.783, p: 0.001). But the TT-PCL (rho: 0.459, p: 0.001) and nTT-PCL (rho: 0.589, p: 0.001) had a medium correlation. Conclusions: The Akagi line might cause unacceptable external rotation of the tibial component in patients with PF malalignment. The use of the modified Akagi line described in this study may be a solution for the rotational mismatch between femoral and tibial components in TKA. Level of evidence: Level III, retrospective case-control study.

9.
Knee ; 37: 132-142, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35779431

RESUMO

BACKGROUND: Antero-medialisation osteotomy combined with a distalisation procedure may require a more stable fixation as the osteotomy fragment loses both proximal and distal support. This finite element analysis aimed to compare the mechanical behaviour of different fixation techniques in tibial tubercle antero-medialisation osteotomy combined with distalisation procedure. METHODS: Tibial tubercle osteotomy combined with distalisation was modelled based on computerised tomography data, which were acquired from a patient with patellar instability requiring this procedure. Six different fixation configurations with two 3.5-mm cortical screws (1), two 4.5-mm cortical screws (2), three 3.5-mm cortical screws (3), three 4.5-mm cortical screws (4), three 3.5-mm screws with 1/3 tubular plate (5), and four 3.5-mm screws with 1/3 tubular plate (6) were created. A total of 1654 N of force was applied to the patellar tendon footprint on the tibial tubercle. Sliding, gap formation, and total deformation between the osteotomy components were analyzed. RESULTS: Maximum sliding (0.660 mm), gap formation (0.661 mm), and displacement (1.267 mm) were seen with two 3.5-mm screw fixation, followed by two 4.5-mm screws, three 3.5-mm screws, and three 4.5-mm screws, respectively, in the screw-only group. Overall, the minimum displacement was observed with the four 3.5-mm screws with 1/3 tubular plate fixation model. CONCLUSIONS: Plate fixation might be recommended for tibial tubercle antero-medialisation osteotomy combined with distalisation procedure because it might allow early active range of motion exercises and weight-bearing.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Análise de Elementos Finitos , Humanos , Osteotomia/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
10.
J Am Podiatr Med Assoc ; 98(6): 469-72, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19017856

RESUMO

Pure open dislocation of the ankle, or dislocation not accompanied by rupture of the tibiofibular syndesmosis ligaments or fractures of the malleoli or of the posterior border of the tibia, is an extremely rare injury. A 62-year-old man injured his right ankle in a motor vehicle accident. Besides posterolateral ankle dislocation, there was a 7-cm transverse skin cut on the medial malleolus, and the distal end of the tibia was exposed. After reduction, we made a 2- to 2.5-cm longitudinal incision on the lateral malleolus; the distal fibular fracture was exposed. Two Kirschner wires were placed intramedullary in a retrograde manner, and the fracture was stabilized. The deltoid ligament and the medial capsule were repaired. The tibiofibular syndesmosis ligaments were intact. At the end of postoperative year 1, right ankle joint range of motion had a limit of approximately 5 degrees in dorsiflexion, 10 degrees in plantarflexion, 5 degrees in inversion, and 0 degrees in eversion. The joint appeared normal on radiographs, with no signs of osteoarthritis or calcification. The best result can be obtained with early reduction, debridement, medial capsule and deltoid ligament restoration, and early rehabilitation. Clinical and radiographic features at long-term follow-up also confirm good mobility of the ankle without degenerative change or mechanical instability.


Assuntos
Articulação do Tornozelo , Fraturas Expostas/diagnóstico , Luxações Articulares/diagnóstico , Fraturas da Tíbia/diagnóstico , Fraturas Expostas/complicações , Fraturas Expostas/terapia , Humanos , Luxações Articulares/complicações , Luxações Articulares/terapia , Masculino , Pessoa de Meia-Idade , Fraturas da Tíbia/complicações , Fraturas da Tíbia/terapia
11.
Ann Acad Med Singap ; 36(4): 267-71, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17483856

RESUMO

INTRODUCTION: Spiral and oblique fractures of distal 1/3 of tibia-fibula are relatively common fractures of long bones. Due to their types, aetiology, limited coverage and blood supply, these fractures often lead to union and soft tissue problems. MATERIALS AND METHODS: Twenty-seven patients with spiral and oblique fractures of distal 1/3 of tibia-fibula were treated with circular external fixator (CEF) between January 1997 and August 2000. All the fractures were closed. The type of fractures based on AO classification were A1 (n = 8), A2 (n = 6), B1 (n = 11) and C1 (n = 2). RESULTS: The mean framing time was 14.1 +/- 1.8 weeks (range, 12 to 19 weeks), and the mean treatment time was 18.8 +/- 2.2 weeks (range, 15 to 24 weeks). The patients were followed up for 36 to 78 months (mean follow-up time: 51.9 +/- 10.4 months). The results were evaluated for shortness, angulation, rotation, ankle stiffness, pain and infection. After removal of the frames, 11 patients had ankle pain and stiffness, and 3 patients had loss of range of motion in the ankle even after rehabilitation. None of the patients suffered any complications such as shortness, angulation, rotational deformity and infection, and none had loss of motion in the knee. CONCLUSIONS: CEF might be a preferable alternative treatment for distal tibia-fibula fractures due to its easy application, fewer major complications such as shortness and angulation, early mobilisation and shorter treatment time.


Assuntos
Fixadores Externos , Fíbula/cirurgia , Fraturas Ósseas/cirurgia , Fraturas Mal-Unidas/cirurgia , Avaliação de Resultados em Cuidados de Saúde , Fraturas da Tíbia/cirurgia , Acidentes por Quedas , Acidentes de Trânsito , Adulto , Idoso , Traumatismos em Atletas , Feminino , Fíbula/lesões , Fraturas Ósseas/etiologia , Fraturas Ósseas/patologia , Humanos , Técnica de Ilizarov , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Amplitude de Movimento Articular , Fraturas da Tíbia/etiologia , Fraturas da Tíbia/patologia , Turquia
15.
Int Orthop ; 32(6): 785-90, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17581751

RESUMO

The treatment protocol of closed calcaneal fractures has been described in the literature extensively. However, treatment of open calcaneal fractures has not been discussed in detail. Various treatment alternatives have been suggested including external fixator, primary subtalar distraction arthrodesis, and partial calcanectomy according to the type of fracture. We have retrospectively reviewed 36 adult patients with 39 open calcaneal fractures who were treated with our new philosophy. Average follow-up time was 9.29 years (range, 1.25-28 years). The American Orthopaedic Foot and Ankle Society (AOFAS) scoring system was used in functional evaluation. The average score was 77.9 (range, 67-92). All of the patients had limited subtalar movement. We propose an algorithm for the management of open calcaneus fractures, although treatment largely depends on the physical status of the patient, type of the fracture, localisation of the open wound and the surgeon's choice.


Assuntos
Calcâneo/lesões , Fixadores Externos , Fraturas Expostas/cirurgia , Adulto , Idoso , Seguimentos , Fixação de Fratura/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Cicatrização , Adulto Jovem
16.
Arch Orthop Trauma Surg ; 128(1): 17-24, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17436006

RESUMO

INTRODUCTION: In this retrospective study, we aimed to present 8-12-year clinical and radiographic evaluation of total elbow arthroplasty in young patients who had open fractures due to gunshot injuries. MATERIALS AND METHODS: The study included a consecutive series of seven patients who had insertion of total elbow prosthesis (semi-constrained type) for the treatment of comminuted intra-articular elbow fractures resulting from gunshot injuries between 1994 and 1998. All patients were male and the mean age at the time of operation was 23 years. RESULTS: The average time from the original fracture to the joint replacement was 26 months (range 14-39). The mean follow-up period was 117 +/- 15 months. At the time of the latest follow-up, 5 of 7 elbows had a poor result. Radiological evaluations revealed that three patients had ulnar and two patients had humeral component loosening at the last follow-up examination. No intra-operative complications were observed. In the long-term evaluation, two patients had prosthesis loosening that resulted from deep infection and three patients had aseptic loosening that necessitated re-operation. The prosthesis removal was performed. CONCLUSION: As a result, the patients in whom we implemented total elbow prosthesis in comminuted elbow fractures due to gunshot wounds seemed to get back into active life in the early period without any problem and it seemed that their pain disappeared and their functional capacity increased. In the long period, however, these values showed a distinct decrease with the same patients.


Assuntos
Artroplastia de Substituição , Lesões no Cotovelo , Fraturas Cominutivas/cirurgia , Ferimentos por Arma de Fogo/complicações , Adulto , Artroplastia de Substituição/métodos , Articulação do Cotovelo/fisiopatologia , Seguimentos , Humanos , Masculino , Falha de Prótese , Infecções Relacionadas à Prótese/epidemiologia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA