Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Biofouling ; 31(7): 543-54, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26293793

RESUMO

This study was undertaken to compare the immunogenicity and protective potential of biofilm vs planktonic Staphylococcus aureus vaccine for the prevention of mastitis using the mouse as a model system. Mice immunized with formalin-killed whole cell vaccine of S. aureus residing in a biofilm when delivered via an intramammary route produced a cell mediated immune response. Mice immunized with this biofilm vaccine showed significant reductions in colonization by S. aureus in mammary glands, severity of clinical symptoms and tissue damage in mammary glands in comparison with the mice immunized with formalin-killed whole cells of planktonic S. aureus. The planktonic vaccine administered by a subcutaneous route produced a significantly higher humoral immune response (IgG1 and IgG) than the biofilm vaccine. However, considering the host response, tissue damage, the clinical severity and colonization of S. aureus in mammary glands, the biofilm vaccine performed better in immunogenicity and protective potential when administered by the intramammary route.


Assuntos
Biofilmes/efeitos dos fármacos , Mastite Bovina , Plâncton/microbiologia , Infecções Estafilocócicas , Vacinas Antiestafilocócicas/farmacologia , Staphylococcus aureus/imunologia , Animais , Bovinos , Feminino , Humanos , Imunoglobulina G/análise , Mastite Bovina/imunologia , Mastite Bovina/microbiologia , Mastite Bovina/prevenção & controle , Camundongos , Modelos Animais , Infecções Estafilocócicas/imunologia , Infecções Estafilocócicas/prevenção & controle
2.
Int J Infect Dis ; 138: 91-96, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37952911

RESUMO

We investigated intra-host genetic evolution using two SARS-CoV-2 isolates from a fully vaccinated (primary schedule x2 doses of AstraZeneca plus a booster of Pfizer), >70-year-old woman with a history of lymphoma and hypertension who presented a SARS-CoV-2 infection for 3 weeks prior to death due to COVID-19. Two full genome sequences were determined from samples taken 13 days apart with both belonging to Pango lineage FL.2: the first detection of this Omicron sub-variant in Botswana. FL.2 is a sub-lineage of XBB.1.9.1. The repertoire of mutations and minority variants in the Spike protein differed between the two time points. Notably, we also observed deletions within the ORF1a and Membrane proteins; both regions are associated with high T-cell epitope density. The internal milieu of immune-suppressed individuals may accelerate SARS-CoV-2 evolution; hence, close monitoring is warranted.


Assuntos
COVID-19 , Feminino , Humanos , Idoso , SARS-CoV-2/genética , Botsuana , Infecções Irruptivas
3.
AIDS ; 36(6): 755-762, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35113045

RESUMO

OBJECTIVES: We sought to determine vaccine antibody titres and the prevalence of hepatitis B surface antigen (HBsAg) in both HIV-positive and HIV-negative infants born to HIV-positive mothers in Botswana. DESIGN: This was a retrospective cross-sectional study using 449 archived dried blood spot samples from both HIV-positive and HIV-negative infants collected between 2016 and 2018. METHODS: We screened dried blood spot samples for HBsAg and determined hepatitis B surface antibody titres. We determined hepatitis B virus (HBV) genotypes by amplifying 415 base-pairs of the surface region. RESULTS: HIV-positive infants mounted a significantly lower immune response to the HBV vaccine (P  < 0.001). Furthermore, a lower proportion of HIV-positive infants had protective hepatitis B surface antibody titres (74.5%) than HIV-negative infants (89.2%) (P < 0.001). HIV-positive infants were older and 50.9% of them had completed vaccination (P = 0.018). Of the 449 infant samples tested, three (0.67%) were positive for HBsAg. Of the three HBsAg-positive infants, two had protective titres (>10 mIU/ml). Two of the three HBV-positive infants were infected with genotype D3 and had no drug-resistance or escape mutations. CONCLUSION: Vaccine response was lower among HIV-positive infants compared with HIV-negative infants. HBV infections were observed in both HIV-positive and HIV-negative infants in Botswana. Studies to investigate additional preventive strategies to reduce HBV mother-to-child transmission are recommended.


Assuntos
Infecções por HIV , Soropositividade para HIV , Hepatite B , Vacinas Virais , Botsuana/epidemiologia , Estudos Transversais , Feminino , Infecções por HIV/complicações , Hepatite B/prevenção & controle , Anticorpos Anti-Hepatite B , Antígenos de Superfície da Hepatite B , Vírus da Hepatite B , Humanos , Lactente , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Estudos Retrospectivos
5.
J Virol Methods ; 159(1): 93-7, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19442851

RESUMO

Roche COBAS Amplicor monitor version 1.5 assay is considered gold standard for viral load monitoring in Botswana. Due to its demand for elaborate infrastructure, viral load testing has been confined to the national HIV reference laboratories. Cavidi ExaVir Load version 2 assay was considered as a potential alternative to decentralize viral load testing to the rural/remote hospital laboratories and thus increase access to therapy. This study compared the performance of ExaVir Load v2 assay at a district hospital laboratory in Serowe and COBAS Amplicor monitor v1.5 assay at the Botswana Harvard HIV Reference Laboratory using quality assessment samples and plasma from HIV-positive individuals. ExaVir Load v2 and COBAS Amplicor monitor v1.5 assays had very good agreement; Kappa statistic 0.951. The COBAS Amplicor monitor v1.5 and ExaVir Load v2 assays detected HIV-1 RNA in 84 and 86 samples but did not detect HIV-1 RNA in 221 and 219 samples, respectively. The two assays detected HIV-1 RNA concordantly in 82 samples and were strongly correlated (r=0.8554, P<0.0001). ExaVir Load v2 assay provided a simple and reliable alternative viral load system that is adaptable to district hospital laboratories. The cost per test is less than RT-PCR. The ExaVir Load v2 systems have since been placed in four more district and primary hospital laboratories.


Assuntos
Infecções por HIV/virologia , Transcriptase Reversa do HIV/metabolismo , HIV-1/enzimologia , Hospitais de Distrito , Carga Viral/métodos , Botsuana , Infecções por HIV/sangue , HIV-1/genética , Humanos , Laboratórios Hospitalares , Projetos Piloto , Política , RNA Viral/isolamento & purificação , Kit de Reagentes para Diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA