1.
Lasers Med Sci ; 38(1): 94, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-36973553

RESUMO

Due to wavelength-specific water absorption, infrared lasers like the thulium laser emitting at 1940 nm wavelength proved to be suitable for coagulation in neurosurgery. Commonly bipolar forceps used for intraoperative haemostasis can cause mechanical and thermal tissue damage, whilst thulium laser can provide a tissue-gentle haemostasis through non-contact coagulation. The aim of this work is a less-damaging blood vessel coagulation by pulsed thulium laser radiation in comparison to standard bipolar forceps haemostasis. Ex vivo porcine blood vessels in brain tissue (0.34 ± 0.20 mm diameter) were irradiated in non-contact with a thulium laser in pulsed mode (1940 nm wavelength, 15 W power, 100-500 ms pulse duration), with a CO2 gas flow provided simultaneously at the distal fibre tip (5 L/min). In comparison, a bipolar forceps was used at various power levels (20-60 W). Tissue coagulation and ablation were evaluated by white light images and vessel occlusion was visualised by optical coherence tomography (OCT) B-scans at a wavelength of 1060 nm. Coagulation efficiency was calculated by means of the quotient of the difference between the coagulation and ablation radius to the coagulation radius. Pulsed laser application achieved blood vessel occlusion rate of 92% at low pulse duration of 200 ms with no occurrence of ablation (coagulation efficiency 100%). Bipolar forceps showed an occlusion rate of 100%, however resulted in tissue ablation. Tissue ablation depth with laser application is limited to 40 µm and by a factor of 10 less traumatising than with bipolar forceps. Pulsed thulium laser radiation achieved blood vessel haemostasis up to 0.3 mm in diameter without tissue ablation and has proven to be a tissue-gentle method compared to bipolar forceps.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Neoplasias , Animais , Suínos , Terapia a Laser/métodos , Túlio , Lasers , Instrumentos Cirúrgicos , Hemostasia
2.
Int J Mol Sci ; 24(5)2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36902189

RESUMO

BACKGROUND: Preliminary clinical work indicates that increasing eyelid tension improves the function of the meibomian glands. The aim of this study was to optimize laser parameters for a minimally invasive laser treatment to increase eyelid tension by coagulation of the lateral tarsal plate and canthus. METHODS: Experiments were performed on a total of 24 porcine lower lids post mortem, with six lids in each group. Three groups were irradiated with an infrared B radiation laser. Laser-induced lower eyelid shortening was measured and the increase in eyelid tension was assessed with a force sensor. A histology was performed to evaluate coagulation size and laser-induced tissue damage. RESULTS: In all three groups, a significant shortening of the eyelids after irradiation was noticed (p < 0.0001). The strongest effect was seen with 1940 nm/1 W/5 s, showing -15.1 ± 3.7% and -2.5 ± 0.6 mm lid shortening. The largest significant increase in eyelid tension was seen after placing the third coagulation. CONCLUSION: Laser coagulation leads to lower eyelid shortening and an increase in lower eyelid tension. The strongest effect with the least tissue damage was shown for laser parameters of 1470 nm/2.5 W/2 s. In vivo studies of this effect have to confirm the efficacy of this concept prior to clinical application.


Assuntos
Lasers , Glândulas Tarsais , Animais , Suínos , Glândulas Tarsais/patologia , Raios Infravermelhos , Fenômenos Mecânicos , Lágrimas
3.
Graefes Arch Clin Exp Ophthalmol ; 259(2): 387-393, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32960320

RESUMO

PURPOSE: Tilted disc syndrome (TDS) may be associated with a macular serous retinal detachment (MSRD). However, ideal therapy for this complication is still unestablished yet to date. The purpose of this study is to investigate the effect of selective retina therapy (SRT) for MSRD associated with TDS. METHODS: This retrospective study included 11 eyes of 10 patients (1 male and 9 females), who were treated with SRT for MSRD associated with TDS, and observed at least 12 months after treatment. The mean age was 56 years old (range 44-66). An SRT laser (527 nm, 1.7 µs, 100 Hz; Medical Laser Center Lübeck, Germany) was used for treatment. The changes of best-corrected visual acuity (BCVA), central macular thickness (CMT), and central choroidal thickness (CCT) were examined. Subfoveal curve height (SFCH) was calculated at baseline. RESULTS: The mean follow-up period was 24.4 months (range 12-48 months). The mean BCVA (logMAR), CMT, and CCT changed from 0.03 ± 0.10, 324 ± 82 µm, and 194 ± 68 µm preoperatively to 0.07 ± 0.17, 274 ± 94 µm, and 188 ± 65 µm at final follow-up, respectively, with significant difference on CMT (BCVA: p = 0.44, CMT: p < 0.05, CCT: p = 0.21). The MSRD disappeared in 6 eyes (55%) and the average number of SRT irradiations until resolution of MSRD was 2.6 times (range 1-5 times). There was no significant association between SFCH and resolution of MSRD (p = 0.19). CONCLUSIONS: SRT may promote absorption of MSRD and maintenance of BCVA for TDS. Randomized and prospective clinical studies are needed to evaluate the effectiveness of SRT for MSRD associated with TDS.


Assuntos
Descolamento Retiniano , Adulto , Idoso , Feminino , Angiofluoresceinografia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Retina , Descolamento Retiniano/diagnóstico , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual
4.
Graefes Arch Clin Exp Ophthalmol ; 259(6): 1503-1511, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33346888

RESUMO

PURPOSE: The treatment guidelines for many macular diseases rely on frequent monitoring with optical coherence tomography (OCT). However, the burden of frequent disease control leads to low therapy adherence in real life. OCT home monitoring would address this issue but requires an inexpensive and self-operable device. With self-examination low-cost full-field OCT (SELFF-OCT), our group has introduced a novel technology that may fulfill both requirements. In this pilot study, we report the initial experiences with a clinical prototype. METHODS: Fifty-one patients with different macular diseases were recruited in a cross-sectional study. The most common diseases were age-related macular degeneration (AMD; 39/51), diabetic macular edema (DME; 6/51), and retinal vein occlusion (RVO; 3/51). Patients received a short training in device usage and then performed multiple self-scans with the SELFF-OCT device. For comparison, scans with a standard clinical spectral domain (SD-)OCT were taken. RESULTS: After a brief training, 77% of the patients were able to successfully acquire images that were clinically gradable. No significant influence on success could be found for age (p = 0.08) or BCVA (p = 0.97). Relevant disease biomarkers in the most common retinal diseases could be detected. CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination and in the future could be used for retinal home monitoring. Future improvements in technology are expected to improve success rates and image quality. TRIAL REGISTRATION: The Trial was registered in the German Trial Register under the number DRKS00013755 on 14.03.2018.


Assuntos
Retinopatia Diabética , Edema Macular , Doenças Retinianas , Estudos Transversais , Humanos , Edema Macular/diagnóstico , Projetos Piloto , Autoexame , Tomografia de Coerência Óptica
5.
Int Ophthalmol ; 40(5): 1221-1232, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31950333

RESUMO

PURPOSE: To investigate the predictive factors of clinical outcome of selective retina therapy (SRT) for diabetic macular edema (DME). METHODS: This retrospective study included 22 eyes of 22 patients (15 males and 7 females), who were treated with SRT for DME at the Department of Ophthalmology of Osaka City University Hospital and observed at least 6 months after the treatment. The mean age was 64 years (range 40-81). Thirteen of the 22 eyes (59%) had a treatment history other than SRT before. SRT laser (527 nm, 1.7 µs, 100 Hz) was used for treatment. Changes in the best-corrected visual acuity (BCVA) (logMAR) and central macular thickness (CMT) in optical coherence tomography were examined at baseline, 3-month follow-up, and 6-month follow-up. Factors associated with the rate of change in CMT at 3 and 6 months after SRT were examined. RESULTS: The mean BCVA (logMAR) was 0.26 ± 0.31, 0.22 ± 0.27 and 0.23 ± 0.29 at baseline, 3 months and 6 months, respectively (p = 0.15 at 3 months, 0.40 at 6 months; compared to baseline). The mean CMT was 502 ± 163, 493 ± 204, and 416 ± 185 µm at baseline, 3 months, and 6 months, respectively (p = 0.69 at 3 months, 0.01 at 6 months; compared to baseline). The multivariate analysis found a significant negative association with previous macular photocoagulation (p = 0.03) at 3 months and a positive association with a history of insulin use (p = 0.02) and previous panretinal photocoagulation (p = 0.03) at 6 months after SRT. CONCLUSION: The CMT was significantly decreased at 6 months after SRT in DME. The history of insulin use and panretinal photocoagulation may positively and the history of macular photocoagulation may negatively affect the outcome of SRT, which must be considered when determining the therapeutic indications for SRT.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Retinopatia Diabética/complicações , Gerenciamento Clínico , Fotocoagulação a Laser/métodos , Edema Macular/terapia , Retina/diagnóstico por imagem , Triancinolona Acetonida/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/terapia , Feminino , Angiofluoresceinografia , Seguimentos , Fundo de Olho , Glucocorticoides/administração & dosagem , Humanos , Injeções Intraoculares , Edema Macular/diagnóstico , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Tomografia de Coerência Óptica
6.
Int J Hyperthermia ; 36(1): 466-472, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30922131

RESUMO

Objective/Purpose: In order to study the effects of hyperthermia and other temperature-related effects on cells and tissues, determining the precise time/temperature course is crucial. Here we present a non-contact optoacoustic technique, which provides temperatures during heating of cultured cells with scalable temporal and spatial resolution. METHODS: A thulium laser (1.94 µm) with a maximum power of 15 W quickly and efficiently heats cells in a culture dish because of low penetration depth (1/e penetration depths of 78 µm) of the radiation in water. A repetitively Q-switched holmium laser (2.1 µm) is used simultaneously to probe temperatures at different locations in the dish by using the photoacoustic effect. Due to thermoelastic expansion of water, pressure waves are emitted and measured with an ultrasonic hydrophone at the side of the dish. The amplitudes of the waves are temperature dependent and can be used to calculate the temperature/time course at any location of probing. RESULTS: We measured temperatures of up to 55 °C with a heating power of 6 W after 10 s, and subsequent lateral temperature profiles over time. Within this profile, temperature fluctuations were found, likely owing to thermal convection and water circulation. By using cultured retinal pigment epithelial cells, it is shown that the probe laser pulses alone cause no biological damage, while immediate cell damage occurs when heating for 10 s at temperatures exceeding 45 °C. CONCLUSIONS: This method shows great potential not only as a noninvasive, non-contact method to determine temperature/time responses of cells in culture, but also for complex tissue and other materials.


Assuntos
Temperatura Alta/uso terapêutico , Hipertermia Induzida/métodos , Células Cultivadas , Estudos de Viabilidade , Humanos
7.
Surg Endosc ; 32(12): 4966-4972, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29869079

RESUMO

BACKGROUND: Hepatocellular carcinoma is a highly prevalent and lethal primary neoplasia of the liver and metastases of other malignancies affect most frequently the liver. Minimally invasive surgical approach for liver resections is advancing. Dissection of liver parenchyma by laparoscopic technique remains challenging and new technologies are in need. Therefore, we asked whether it is feasible to dissect liver tissue comparably in terms of speed and hemostasis with a non-contact 1.9-µm cw-laser device and whether there are differences in the postoperative healing process compared to a gold standard device (ultrasound aspirator) in an experimental model. METHODS: Laparoscopic laser and ultrasound aspirator standardized partial liver resections were performed in seven pigs. Resection time, hemostasis time, and blood loss were evaluated. After at least 10 days, representative specimen of the resection areas was collected via re-laparoscopy and biopsy and side effects like hematoma, abscess, or bilioma were noted. Histologically, coagulation necrosis margin, granulation tissue zone, tissue fibrosis, and giant cell count were analyzed. RESULTS: Laparoscopic laser liver resection was three times faster compared to the laparoscopic ultrasound aspirator. Blood loss was equal in both groups. No side effects like hematoma or bilioma occurred. Histologically, specimen showed the same expansion of coagulation necrosis zone and granulation tissue. Fibrotic scar could be determined in three cases in both groups, respectively. However, giant cell count was significant higher in the laser resection group. CONCLUSIONS: The 1.9-µm cw-laser device enables a safe and fast liver resection in an experimental pig model compared to a gold standard (ultrasound aspirator) laparoscopic liver resection method. Wound healing is not interfered by laser liver resection.


Assuntos
Carcinoma Hepatocelular/cirurgia , Hepatectomia/métodos , Laparoscopia/métodos , Terapia a Laser/métodos , Neoplasias Hepáticas Experimentais/cirurgia , Animais , Suínos
8.
Graefes Arch Clin Exp Ophthalmol ; 255(2): 243-254, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27497611

RESUMO

PURPOSE: To assess retinal sensitivity after selective retina therapy (SRT) in patients with central serous chorioretinopathy (CSCR). METHODS: Seventeen eyes of 17 patients with CSCR lasting longer than 3 months were treated with SRT (wavelength 527 nm Nd: YLF laser, 50-150 µJ/pulse, spot diameter 200 µm). Measurement of best-corrected visual acuity (BCVA), optical coherence tomography, fluorescence angiography, and microperimetry (MAIA™) were conducted before, and 1 and 3 months after treatment. Microperimetry was performed in the central 10° of the macula, and at the test spots applied near the vascular arcade for energy titration. In addition to the treatment effect, all test irradiation spots were thoroughly analyzed with regard to their sensitivity changes. RESULTS: The mean logMAR BCVA had improved from 0.06 to 0.02 after 1 month (p = 0.11) and to 0.03 after 3 months (p = 0.003). Eleven out of 17 eyes (64.7%) showed complete resolution of subretinal fluid after 3 months. Retinal sensitivity in the central 10° increased after 1 month (median: 25.9 dB) and 3 months (26.6 dB) as compared with that before treatment (23.0 dB) (p < 0.001). Analysis of the test spots revealed a slight decrease in retinal sensitivity after 1 month (ΔdB = -0.5 ± 2.1, p = 0.006), while there was no significant difference from baseline after 3 months (ΔdB = -0.3 ± 2.2, p = 0.09). No correlation was found between laser energy and the change in focal retinal sensitivity. CONCLUSIONS: Results suggest that SRT is a safe and effective treatment for persistent CSCR and does not leave permanent scotoma regardless of irradiation energy in the therapeutic range.


Assuntos
Coriorretinopatia Serosa Central/tratamento farmacológico , Fotocoagulação a Laser/métodos , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/uso terapêutico , Retina/fisiopatologia , Epitélio Pigmentado da Retina/patologia , Campos Visuais/fisiologia , Adulto , Idoso , Coriorretinopatia Serosa Central/diagnóstico , Coriorretinopatia Serosa Central/fisiopatologia , Feminino , Angiofluoresceinografia , Seguimentos , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Retina/patologia , Estudos Retrospectivos , Líquido Sub-Retiniano/diagnóstico por imagem , Fatores de Tempo , Tomografia de Coerência Óptica , Acuidade Visual , Testes de Campo Visual
9.
Graefes Arch Clin Exp Ophthalmol ; 254(9): 1703-13, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26803489

RESUMO

PURPOSE: Selective retina therapy (SRT) stimulates retinal pigment epithelium (RPE) cell migration and proliferation into irradiated areas. The objective of this study was to evaluate the efficacy and safety of SRT in Korean patients with clinically significant diabetic macular edema (DME). METHODS: Prospective non-randomized interventional case series study. Twenty-three eyes of 21 patients with clinically significant DME were treated with SRT and followed for 6 months. Patients underwent an evaluation of best corrected visual acuity (BCVA) in Early Treatment Diabetic Retinopathy Study (ETDRS) letters. Microperimetry was employed to measure macular sensitivity within the central 10° field, and the central macular thickness (CMT) and maximum macular thickness (MMT) were measured. RESULTS: An improvement in BCVA of one to two ETDRS lines was observed in 41.2 % of patients and an improvement of greater than two lines in 29.4 %. Although there was no significant change in CMT (P > 0.05), MMT decreased from 465.8 ± 87.4 µm to 434.3 ± 83.9 µm (P = 0.006), and mean macular sensitivity increased from 20.8 ± 3.4dB to 22.5 ± 3.5dB (P = 0.02). CONCLUSIONS: The gains in BCVA and improvement in macular sensitivity demonstrated that SRT may be used as an effective and safe treatment modality in Korean patients with clinically significant DME.


Assuntos
Retinopatia Diabética/cirurgia , Terapia a Laser/métodos , Edema Macular/cirurgia , Epitélio Pigmentado da Retina/diagnóstico por imagem , Idoso , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/epidemiologia , Feminino , Angiofluoresceinografia , Seguimentos , Fundo de Olho , Humanos , Incidência , Edema Macular/diagnóstico , Edema Macular/epidemiologia , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , República da Coreia/epidemiologia , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Acuidade Visual
10.
Ophthalmologica ; 234(4): 177-88, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26368551

RESUMO

PURPOSE: Selective retina therapy (SRT), the confined laser heating and destruction of retinal pigment epithelial cells, has been shown to treat acute types of central serous chorioretinopathy (CSC) successfully without damaging the photoreceptors and thus avoiding laser-induced scotoma. However, a benefit of laser treatment for chronic forms of CSC is questionable. In this study, the efficacy of SRT by means of the previously used 1.7-µs and shorter 300-ns pulse duration was evaluated for both types of CSC, also considering re-treatment for nonresponders. MATERIAL AND METHODS: In a two-center trial, 26 patients were treated with SRT for acute (n = 10) and chronic-recurrent CSC (n = 16). All patients presented with subretinal fluid (SRF) in OCT and leakage in fluorescein angiography (FA). SRT was performed using a prototype SRT laser system (frequency-doubled Q-switched Nd:YLF-laser, wavelength 527 nm) with adjustable pulse duration. The following irradiation settings were used: a train of 30 laser pulses with a repetition rate of 100 Hz and pulse durations of 300 ns and 1.7 µs, pulse energy 120-200 µJ, retinal spot size 200 µm. Because SRT lesions are invisible, FA was always performed 1 h after treatment to demonstrate laser outcome (5-8 single spots in the area of leakage). In cases where energy was too low, as indicated by missing FA leakage, energy was adjusted and the patient re-treated immediately. Observation intervals were after 4 weeks and 3 months. In case of nonimprovement of the disease after 3 months, re-treatment was considered. RESULTS: Of 10 patients with active CSC that presents focal leakage in FA, 5 had completely resolved fluid after 4 weeks and all 10 after 3 months. Mean visual acuity increased from 76.6 ETDRS letters to 85.0 ETDRS letters 3 months after SRT. Chronic-recurrent CSC was characterized by less severe SRF at baseline in OCT and weaker leakage in FA than in acute types. Visual acuity changed from baseline 71.6 to 72.8 ETDRS letters after 3 months. At this time, SRF was absent in 3 out of 16 patients (19%), FA leakage had come to a complete stop in 6 out of 16 patients (38%). In 6 of the remaining chronic CSC patients, repeated SRT with higher pulse energy was considered because of persistent leakage activity. After the re-treatment, SRF resolved completely in 5 patients (83.3%) after only 25 days. CONCLUSION: SRT showed promising results in treating acute CSC, but was less effective in chronic cases. Interestingly, re-treatment resulted in enhanced fluid resolution and dry conditions after a considerably shorter time in most patients. Therefore, SRT including re-treatment if necessary might be a valuable CSC treatment alternative even in chronic-recurrent cases.


Assuntos
Coriorretinopatia Serosa Central/cirurgia , Fotocoagulação a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Doença Aguda , Adulto , Barreira Hematorretiniana , Permeabilidade Capilar , Coriorretinopatia Serosa Central/diagnóstico , Coriorretinopatia Serosa Central/fisiopatologia , Doença Crônica , Angiofluoresceinografia , Humanos , Pessoa de Meia-Idade , Líquido Sub-Retiniano , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
11.
Clin Exp Ophthalmol ; 42(9): 846-55, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24698550

RESUMO

BACKGROUND: The purpose of the study was to evaluate the safety and selectivity of the retinal pigment epithelium lesions by using automatic energy ramping and dosimetry technique for selective retina therapy and to investigate the healing response. METHODS: Ten eyes of Chinchilla Bastard rabbits were treated with an automatic dosage controlled selective retina therapy laser (frequency doubled Q-switched Nd:YLF, wavelength: 527 nm, pulse duration: 1.7 µs, repetition rate: 100 Hz, pulse energy: linear increasing from pulse to pulse up to shut down - maximal 110 µJ, max. number of pulses in a burst: 30, retinal spot diameter: 133 µm). After treatment, fundus photography, optical coherence tomography and fluorescein angiography were performed at three time points from 1 h to 3 weeks. Histological analysis was performed. RESULTS: A total of 381 selective retina therapy laser spots were tested (range 13-104 µJ).Typical fundus photographs obtained at 1 h after irradiation showed that 379 out of 381 lesions produced by selective retina therapy were not visible ophthalmoscopically and the lesions could be detected by angiography only. Optical coherence tomography images revealed that the structure of photoreceptors was preserved, but a disrupted retinal pigment epithelium layer was observed as was expected. By 3 weeks, histology showed selective retinal pigment epithelium damage without any effect on the inner retina and focal proliferation of the retinal pigment epithelium layer. CONCLUSIONS: Automatically controlled selective retina therapy is a significant improvement in this innovative treatment. It could be demonstrated that the non-contact, reflectometric technique with a controlled pulse energy ramp is safe and selective.


Assuntos
Fotocoagulação a Laser/métodos , Retina/cirurgia , Doenças Retinianas/diagnóstico , Animais , Angiofluoresceinografia , Lasers de Estado Sólido/uso terapêutico , Coelhos , Retina/patologia , Doenças Retinianas/fisiopatologia , Tomografia de Coerência Óptica , Cicatrização/fisiologia
12.
Transl Vis Sci Technol ; 13(4): 26, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38639930

RESUMO

Purpose: Subdamaging thermal retinal laser therapy has the potential to induce regenerative stimuli in retinal diseases, but validated dosimetry is missing. Real-time optoacoustic temperature determination and control could close this gap. This study investigates a first in vivo application. Methods: Two iterations of a control module that were optically coupled in between a continuous-wave commercial laser source and a commercial slit lamp were evaluated on chinchilla rabbits. The module allows extraction of the temperature rise in real time and can control the power of the therapy laser such that a predefined temperature rise at the retina is quickly achieved and held constant. Irradiations with aim temperatures from 45°C to 69°C were performed on a diameter of 200 µm and a heating time of 100 ms. Results: We analyzed 424 temperature-guided irradiations in nine eyes of five rabbits. The mean difference between the measured and aim temperature was -0.04°C ± 0.98°C. The following ED50 values for visibility thresholds could be determined: 58.6°C for funduscopic visibility, 57.7°C for fluorescein angiography, and 57.0°C for OCT. In all measurements, the correlation of tissue effect was higher to the temperature than to the average heating laser power used. Conclusions: The system was able to reliably perform temperature-guided irradiations, which allowed for better tissue effect control than simple power control. This approach could enhance the accuracy, safety, and reproducibility of thermal stimulating laser therapy. Translational Relevance: This study is a bridge between preclinical ex vivo experiments and a pilot clinical study.


Assuntos
Retina , Doenças Retinianas , Coelhos , Animais , Temperatura , Reprodutibilidade dos Testes , Retina/cirurgia , Doenças Retinianas/cirurgia , Angiofluoresceinografia
13.
J Neurosurg ; : 1-9, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38701517

RESUMO

OBJECTIVE: It has been shown that optical coherence tomography (OCT) can identify brain tumor tissue and potentially be used for intraoperative margin diagnostics. However, there is limited evidence on its use in human in vivo settings, particularly in terms of its applicability and accuracy of residual brain tumor detection (RTD). For this reason, a microscope-integrated OCT system was examined to determine in vivo feasibility of RTD after resection with automated scan analysis. METHODS: Healthy and diseased brain was 3D scanned at the resection edge in 18 brain tumor patients and investigated for its informative value in regard to intraoperative tissue classification. Biopsies were taken at these locations and labeled by a neuropathologist for further analysis as ground truth. Optical OCT properties were obtained, compared, and used for separation with machine learning. In addition, two artificial intelligence-assisted methods were utilized for scan classification, and all approaches were examined for RTD accuracy and compared to standard techniques. RESULTS: In vivo OCT tissue scanning was feasible and easily integrable into the surgical workflow. Measured backscattered light signal intensity, signal attenuation, and signal homogeneity were significantly distinctive in the comparison of scanned white matter to increasing levels of scanned tumor infiltration (p < 0.001) and achieved high values of accuracy (85%) for the detection of diseased brain in the tumor margin with support vector machine separation. A neuronal network approach achieved 82% accuracy and an autoencoder approach 85% accuracy in the detection of diseased brain in the tumor margin. Differentiating cortical gray matter from tumor tissue was not technically feasible in vivo. CONCLUSIONS: In vivo OCT scanning of the human brain has been shown to contain significant value for intraoperative RTD, supporting what has previously been discussed for ex vivo OCT brain tumor scanning, with the perspective of complementing current intraoperative methods for this purpose, especially when deciding to withdraw from further resection toward the end of the surgery.

14.
Life (Basel) ; 13(3)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36983925

RESUMO

The purpose of this study was to compare the safety and efficacy of selective retina therapy (SRT) combined with the intravitreal injection of ranibizumab (IVR) in patients with macular edema (ME) secondary to branch retinal vein occlusion (BRVO). This trial was a 12-month single-center, randomized, single-masked prospective study. Eligible patients were randomized (1:1) to IVR and SRT (IVR + SRT group), or IVR and sham SRT (IVR + sham group). After the initial IVR, all participants received ME resolution criteria-driven pro re nata treatment. SRT or sham SRT was always applied one day after IVR. The primary outcome measure of this study was the mean change in central macular thickness (CMT) from baseline, and the secondary outcome measures were the mean change in visual acuity from baseline and the number of IVR treatments at a 52-week follow-up. Thirteen patients were in the IVR + SRT group, and 11 were in the IVR + sham group. Compared to the baseline, mean CMT and BCVA improved significantly after 52 weeks in both groups, with no significant difference between the two groups. The mean number of IVR was 2.85 ± 1.52 in the IVR + SRT group and 4.73 ± 2.33 in the IVR + sham group at the 52-week follow-up, with a significant difference between the two groups (p < 0.05). IVR combined with SRT may significantly decrease the number of IVR treatments while maintaining the visual and anatomical improvement effect of IVR monotherapy.

15.
Front Oncol ; 13: 1151149, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37139150

RESUMO

Purpose: In brain tumor surgery, it is crucial to achieve complete tumor resection while conserving adjacent noncancerous brain tissue. Several groups have demonstrated that optical coherence tomography (OCT) has the potential of identifying tumorous brain tissue. However, there is little evidence on human in vivo application of this technology, especially regarding applicability and accuracy of residual tumor detection (RTD). In this study, we execute a systematic analysis of a microscope integrated OCT-system for this purpose. Experimental design: Multiple 3-dimensional in vivo OCT-scans were taken at protocol-defined sites at the resection edge in 21 brain tumor patients. The system was evaluated for its intraoperative applicability. Tissue biopsies were obtained at these locations, labeled by a neuropathologist and used as ground truth for further analysis. OCT-scans were visually assessed with a qualitative classifier, optical OCT-properties were obtained and two artificial intelligence (AI)-assisted methods were used for automated scan classification. All approaches were investigated for accuracy of RTD and compared to common techniques. Results: Visual OCT-scan classification correlated well with histopathological findings. Classification with measured OCT image-properties achieved a balanced accuracy of 85%. A neuronal network approach for scan feature recognition achieved 82% and an auto-encoder approach 85% balanced accuracy. Overall applicability showed need for improvement. Conclusion: Contactless in vivo OCT scanning has shown to achieve high values of accuracy for RTD, supporting what has well been described for ex vivo OCT brain tumor scanning, complementing current intraoperative techniques and even exceeding them in accuracy, while not yet in applicability.

16.
Photoacoustics ; 25: 100316, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34926158

RESUMO

OBJECTIVES: Selective Retina Therapy (SRT) uses microbubble formation (MBF) to target retinal pigment epithelium (RPE) cells selectively while sparing the neural retina and the choroid. Intra- and inter-individual variations of RPE pigmentation makes frequent radiant exposure adaption necessary. Since selective RPE cell disintegration is ophthalmoscopically non-visible, MBF detection techniques are useful to control adequate radiant exposures. It was the purpose of this study to evaluate optoacoustically based MBF detection algorithms. METHODS: Fifteen patients suffering from central serous chorioretinopathy and diabetic macula edema were treated with a SRT laser using a wavelength of 527 nm, a pulse duration of 1.7 µs and a pulse energy ramp (15 pulses, 100 Hz repetition rate). An ultrasonic transducer for MBF detection was embedded in a contact lens. RPE damage was verified with fluorescence angiography. RESULTS: An algorithm to detect MBF as an indicator for RPE cell damage was evaluated. Overall, 4646 irradiations were used for algorithm optimization and testing. The tested algorithms were superior to a baseline model. A sensitivity/specificity pair of 0.96/1 was achieved. The few false algorithmic decisions were caused by unevaluable signals. CONCLUSIONS: The algorithm can be used for guidance or automatization of microbubble related treatments like SRT or selective laser trabeculoplasty (SLT).

17.
BMJ Open ; 12(6): e055082, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35760534

RESUMO

OBJECTIVES: Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). DESIGN: Prospective single-arm diagnostic accuracy study. SETTING: Tertiary care centre (University Eye Clinic). PARTICIPANTS: 46 patients with age-related macular degeneration. INTERVENTIONS: Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. PRIMARY OUTCOME MEASURE: Rate of successful self-measurements. SECONDARY OUTCOME MEASURES: Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. RESULTS: In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). CONCLUSIONS: SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. TRIAL REGISTRATION NUMBER: DRKS00013755, CIV-17-12-022384.


Assuntos
Degeneração Macular , Tomografia de Coerência Óptica , Estudos Transversais , Humanos , Degeneração Macular/diagnóstico por imagem , Degeneração Macular/tratamento farmacológico , Estudos Prospectivos , Autoexame , Tomografia de Coerência Óptica/métodos
18.
Front Oncol ; 12: 896060, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36110932

RESUMO

The discrimination of tumor-infiltrated tissue from non-tumorous brain tissue during neurosurgical tumor excision is a major challenge in neurosurgery. It is critical to achieve full tumor removal since it directly correlates with the survival rate of the patient. Optical coherence tomography (OCT) might be an additional imaging method in the field of neurosurgery that enables the classification of different levels of tumor infiltration and non-tumorous tissue. This work investigated two OCT systems with different imaging wavelengths (930 nm/1310 nm) and different resolutions (axial (air): 4.9 µm/16 µm, lateral: 5.2 µm/22 µm) in their ability to identify different levels of tumor infiltration based on freshly excised ex vivo brain samples. A convolutional neural network was used for the classification. For both systems, the neural network could achieve classification accuracies above 91% for discriminating between healthy white matter and highly tumor infiltrated white matter (tumor infiltration >60%) .This work shows that both OCT systems with different optical properties achieve similar results regarding the identification of different stages of brain tumor infiltration.

19.
Phys Med Biol ; 67(13)2022 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-35523170

RESUMO

Identifying tumour infiltration zones during tumour resection in order to excise as much tumour tissue as possible without damaging healthy brain tissue is still a major challenge in neurosurgery. The detection of tumour infiltrated regions so far requires histological analysis of biopsies taken from at expected tumour boundaries. The gold standard for histological analysis is the staining of thin cut specimen and the evaluation by a neuropathologist. This work presents a way to transfer the histological evaluation of a neuropathologist onto optical coherence tomography (OCT) images. OCT is a method suitable for real timein vivoimaging during neurosurgery however the images require processing for the tumour detection. The method demonstrated here enables the creation of a dataset which will be used for supervised learning in order to provide a better visualization of tumour infiltrated areas for the neurosurgeon. The created dataset contains labelled OCT images from two different OCT-systems (wavelength of 930 nm and 1300 nm). OCT images corresponding to the stained histological images were determined by shaping the sample, a controlled cutting process and a rigid transformation process between the OCT volumes based on their topological information. The histological labels were transferred onto the corresponding OCT images through a non-rigid transformation based on shape context features retrieved from the sample outline in the histological image and the OCT image. The accuracy of the registration was determined to be 200 ± 120µm. The resulting dataset consists of 1248 labelled OCT images for each of the two OCT systems.


Assuntos
Encéfalo , Tomografia de Coerência Óptica , Biópsia , Encéfalo/diagnóstico por imagem , Procedimentos Neurocirúrgicos , Coloração e Rotulagem , Tomografia de Coerência Óptica/métodos
20.
Lasers Med Sci ; 26(4): 509-14, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21243512

RESUMO

Nephron-sparing surgery was performed in a porcine model with a 1.92-µm fiber laser dissection device in comparison to a standard high-frequency dissection device. In nine pigs, general anesthesia and a median laparotomy were performed to expose both kidneys. On six kidneys (three HF and three laser) a partial renal parenchyma resection of the lower pole without opening of the renal pelvis was performed (group A). On 12 kidneys (four HF and eight laser), a hemi nephrectomy with opening of the renal pelvis was performed (group B). Total resection time including hemostasis of the remaining tissue was 501 ± 394 s in group "A-laser " vs. 176 ± 139 s in group "A-HF". For the group "B", the total resection time was 1174 ± 501 s (B laser) vs. 960 ± 407 s (B-HF). Blood loss was 28 ± 22 ml in group "A laser " vs. 15 ± 15 ml in group "A-HF". In group "B", the blood loss was 98 ± 73 ml (B laser) vs. 137 ± 118 ml (B-HF). No ischemic time for the kidneys was needed in group "A" for both dissection devices. In group "B", ischemia of the kidneys was performed three times during the eight laser procedures (420 ± 60 s) and only once at the four HF procedures (1,260 s). Healing process was observed over 4-6 weeks, survival rate was 100%, and no renal fistulas were found after the survival period. In conclusion, no significant differences were found between the compared dissection devices. However, the laser system with the flexible transmission fiber may have an advantage for a laparoscopic approach by steerable instruments.


Assuntos
Carcinoma de Células Renais/cirurgia , Neoplasias Renais/cirurgia , Rim/cirurgia , Terapia a Laser/instrumentação , Animais , Hemostasia , Técnicas In Vitro , Terapia a Laser/métodos , Suínos