Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 198
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nat Methods ; 21(6): 1122-1130, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38831210

RESUMO

Long-standing questions about human brain evolution may only be resolved through comparisons with close living evolutionary relatives, such as chimpanzees. This applies in particular to structural white matter (WM) connectivity, which continuously expanded throughout evolution. However, due to legal restrictions on chimpanzee research, neuroscience research currently relies largely on data with limited detail or on comparisons with evolutionarily distant monkeys. Here, we present a detailed magnetic resonance imaging resource to study structural WM connectivity in the chimpanzee. This open-access resource contains (1) WM reconstructions of a postmortem chimpanzee brain, using the highest-quality diffusion magnetic resonance imaging data yet acquired from great apes; (2) an optimized and validated method for high-quality fiber orientation reconstructions; and (3) major fiber tract segmentations for cross-species morphological comparisons. This dataset enabled us to identify phylogenetically relevant details of the chimpanzee connectome, and we anticipate that it will substantially contribute to understanding human brain evolution.


Assuntos
Encéfalo , Conectoma , Pan troglodytes , Substância Branca , Pan troglodytes/anatomia & histologia , Animais , Substância Branca/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Encéfalo/anatomia & histologia , Conectoma/métodos , Masculino , Vias Neurais/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Feminino , Mapeamento Encefálico/métodos
2.
Magn Reson Med ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38817204

RESUMO

PURPOSE: To compare MR axon radius estimation in human white matter using a multiband spiral sequence combined with field monitoring to the current state-of-the-art echo-planar imaging (EPI)-based approach. METHODS: A custom multiband spiral sequence was used for diffusion-weighted imaging at ultra-high b $$ b $$ -values. Field monitoring and higher order image reconstruction were employed to greatly reduce artifacts in spiral images. Diffusion weighting parameters were chosen to match a state-of-the art EPI-based axon radius mapping protocol. The spiral approach was compared to the EPI approach by comparing the image signal-to-noise ratio (SNR) and performing a test-retest study to assess the respective variability and repeatability of axon radius mapping. Effective axon radius estimates were compared over white matter voxels and along the left corticospinal tract. RESULTS: Increased SNR and reduced artifacts in spiral images led to reduced variability in resulting axon radius maps, especially in low-SNR regions. Test-retest variability was reduced by a factor of approximately 1.5 using the spiral approach. Reduced repeatability due to significant bias was found for some subjects in both spiral and EPI approaches, and attributed to scanner instability, pointing to a previously unknown limitation of the state-of-the-art approach. CONCLUSION: Combining spiral readouts with field monitoring improved mapping of the effective axon radius compared to the conventional EPI approach.

3.
Nat Rev Neurosci ; 20(5): 314, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30911159

RESUMO

In this article, the affiliation for Mohit Rana was incorrectly listed as the Institute for Biological and Medical Engineering, Department of Psychiatry, and Section of Neuroscience, Pontificia Universidad Católica de Chile, Vicuña Mackenna 4860 Hernán Briones, piso 2, Macul 782-0436, Santiago, Chile. The listed affiliation should have been the following: Departamento de Psiquiatría, Escuela de Medicina, Centro Interdisciplinario de Neurociencias, Pontificia Universidad Católica de Chile, Santiago, Chile; and the Laboratory for Brain-Machine Interfaces and Neuromodulation, Pontificia Universidad Católica de Chile, Santiago, Chile. An acknowledgement to Mohit Rana's funding source was also missing. The following sentence should have been included in the acknowledgments section: M.R. is supported by a Fondecyt postdoctoral fellowship (project no. 3100648).

4.
Eur J Neurol ; 31(4): e16196, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38258488

RESUMO

BACKGROUND AND PURPOSE: In acute spinal cord injury (SCI), magnetic resonance imaging (MRI) reveals tissue bridges and neurodegeneration for 2 years. This 5-year study aims to track initial lesion changes, subsequent neurodegeneration, and their impact on recovery. METHODS: This prospective longitudinal study enrolled acute SCI patients and healthy controls who were assessed clinically-and by MRI-regularly from 3 days postinjury up to 60 months. We employed histologically cross-validated quantitative MRI sequences sensitive to volume, myelin, and iron changes, thereby reflecting indirectly processes of neurodegeneration and neuroinflammation. General linear models tracked lesion and remote changes in volume, myelin- and iron-sensitive magnetic resonance indices over 5 years. Associations between lesion, degeneration, and recovery (using the Spinal Cord Independence Measure [SCIM] questionnaire and the International Standards for Neurological Classification of Spinal Cord Injury total motor score) were assessed. RESULTS: Patients' motor scores improved by an average of 12.86 (95% confidence interval [CI] = 6.70-19.00) points, and SCIM by 26.08 (95% CI = 17.00-35.20) points. Within 3-28 days post-SCI, lesion size decreased by more than two-thirds (3 days: 302.52 ± 185.80 mm2 , 28 days: 76.77 ± 88.62 mm2 ), revealing tissue bridges. Cervical cord and corticospinal tract volumes transiently increased in SCI patients by 5% and 3%, respectively, accompanied by cervical myelin decreases and iron increases. Over time, progressive atrophy was observed in both regions, which was linked to early lesion dynamics. Tissue bridges, reduced swelling, and myelin content decreases were predictive of long-term motor score recovery and improved SCIM score. CONCLUSIONS: Studying acute changes and their impact on longer follow-up provides insights into SCI trajectory, highlighting the importance of acute intervention while indicating the potential to influence outcomes in the later stages.


Assuntos
Traumatismos da Medula Espinal , Humanos , Estudos Longitudinais , Estudos Prospectivos , Recuperação de Função Fisiológica , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/patologia , Traumatismos da Medula Espinal/reabilitação , Medula Espinal/patologia , Tratos Piramidais/patologia , Imageamento por Ressonância Magnética/métodos , Ferro
5.
Cereb Cortex ; 33(8): 4606-4611, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36169574

RESUMO

There is emerging evidence that sampling the blood-oxygen-level-dependent (BOLD) response with high temporal resolution opens up new avenues to study the in vivo functioning of the human brain with functional magnetic resonance imaging. Because the speed of sampling and the signal level are intrinsically connected in magnetic resonance imaging via the T1 relaxation time, optimization efforts usually must make a trade-off to increase the temporal sampling rate at the cost of the signal level. We present a method, which combines a sparse event-related stimulus paradigm with subsequent data reshuffling to achieve high temporal resolution while maintaining high signal levels (HiHi). The proof-of-principle is presented by separately measuring the single-voxel time course of the BOLD response in both the primary visual and primary motor cortices with 100-ms temporal resolution.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Hemodinâmica/fisiologia , Oxigênio
6.
Cereb Cortex ; 33(9): 5704-5716, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36520483

RESUMO

Quantitative magnetic resonance imaging (qMRI) allows extraction of reproducible and robust parameter maps. However, the connection to underlying biological substrates remains murky, especially in the complex, densely packed cortex. We investigated associations in human neocortex between qMRI parameters and neocortical cell types by comparing the spatial distribution of the qMRI parameters longitudinal relaxation rate (${R_{1}}$), effective transverse relaxation rate (${R_{2}}^{\ast }$), and magnetization transfer saturation (MTsat) to gene expression from the Allen Human Brain Atlas, then combining this with lists of genes enriched in specific cell types found in the human brain. As qMRI parameters are magnetic field strength-dependent, the analysis was performed on MRI data at 3T and 7T. All qMRI parameters significantly covaried with genes enriched in GABA- and glutamatergic neurons, i.e. they were associated with cytoarchitecture. The qMRI parameters also significantly covaried with the distribution of genes enriched in astrocytes (${R_{2}}^{\ast }$ at 3T, ${R_{1}}$ at 7T), endothelial cells (${R_{1}}$ and MTsat at 3T), microglia (${R_{1}}$ and MTsat at 3T, ${R_{1}}$ at 7T), and oligodendrocytes and oligodendrocyte precursor cells (${R_{1}}$ at 7T). These results advance the potential use of qMRI parameters as biomarkers for specific cell types.


Assuntos
Neocórtex , Humanos , Células Endoteliais , Imageamento por Ressonância Magnética/métodos , Encéfalo/patologia , Mapeamento Encefálico/métodos
7.
Neuroimage ; 271: 120046, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36948280

RESUMO

Short MRI acquisition time, high signal-to-noise ratio, and high reliability are crucial for image quality when scanning healthy volunteers and patients. Cross-sectional cervical cord area (CSA) has been suggested as a marker of neurodegeneration and potential outcome measure in clinical trials and is conventionally measured on T1-weigthed 3D Magnetization Prepared Rapid Acquisition Gradient-Echo (MPRAGE) images. This study aims to reduce the acquisition time for the comprehensive assessment of the spinal cord, which is typically based on MPRAGE for morphometry and multi-parameter mapping (MPM) for microstructure. The MPRAGE is replaced by a synthetic T1-w MRI (synT1-w) estimated from the MPM, in order to measure CSA. SynT1-w images were reconstructed using the MPRAGE signal equation based on quantitative maps of proton density (PD), longitudinal (R1) and effective transverse (R2*) relaxation rates. The reliability of CSA measurements from synT1-w images was determined within a multi-center test-retest study format and validated against acquired MPRAGE scans by assessing the agreement between both methods. The response to pathological changes was tested by longitudinally measuring spinal cord atrophy following spinal cord injury (SCI) for synT1-w and MPRAGE using linear mixed effect models. CSA measurements based on the synT1-w MRI showed high intra-site (Coefficient of variation [CoV]: 1.43% to 2.71%) and inter-site repeatability (CoV: 2.90% to 5.76%), and only a minor deviation of -1.65 mm2 compared to MPRAGE. Crucially, by assessing atrophy rates and by comparing SCI patients with healthy controls longitudinally, differences between synT1-w and MPRAGE were negligible. These results demonstrate that reliable estimates of CSA can be obtained from synT1-w images, thereby reducing scan time significantly.


Assuntos
Traumatismos da Medula Espinal , Medula Espinal , Humanos , Reprodutibilidade dos Testes , Estudos Transversais , Medula Espinal/patologia , Imageamento por Ressonância Magnética/métodos , Traumatismos da Medula Espinal/patologia , Atrofia/patologia
8.
Neuroimage ; 274: 120128, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37116765

RESUMO

Motor skill learning relies on neural plasticity in the motor and limbic systems. However, the spatial and temporal characteristics of these changes-and their microstructural underpinnings-remain unclear. Eighteen healthy males received 1 h of training in a computer-based motion game, 4 times a week, for 4 consecutive weeks, while 14 untrained participants underwent scanning only. Performance improvements were observed in all trained participants. Serial myelin- and iron-sensitive multiparametric mapping at 3T during this period of intensive motor skill acquisition revealed temporally and spatially distributed, performance-related microstructural changes in the grey and white matter across a corticospinal-cerebellar-hippocampal circuit. Analysis of the trajectory of these transient changes suggested time-shifted cascades of plasticity from the dominant sensorimotor system to the contralateral hippocampus. In the cranial corticospinal tracts, changes in myelin-sensitive metrics during training in the posterior limb of the internal capsule were of greater magnitude in those who trained their upper limbs vs. lower limb trainees. Motor skill learning is associated with waves of grey and white matter plasticity, across a broad sensorimotor network.


Assuntos
Destreza Motora , Substância Branca , Masculino , Humanos , Aprendizagem , Substância Branca/diagnóstico por imagem , Extremidade Superior , Bainha de Mielina , Plasticidade Neuronal
9.
Neuroimage ; 275: 120152, 2023 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-37142169

RESUMO

The investigation of spontaneous fluctuations of the blood-oxygen-level-dependent (BOLD) signal has recently been extended from the brain to the spinal cord, where it has stimulated interest from a clinical perspective. A number of resting-state functional magnetic resonance imaging (fMRI) studies have demonstrated robust functional connectivity between the time series of BOLD fluctuations in bilateral dorsal horns and between those in bilateral ventral horns, in line with the functional neuroanatomy of the spinal cord. A necessary step prior to extension to clinical studies is assessing the reliability of such resting-state signals, which we aimed to do here in a group of 45 healthy young adults at the clinically prevalent field strength of 3T. When investigating connectivity in the entire cervical spinal cord, we observed fair to good reliability for dorsal-dorsal and ventral-ventral connectivity, whereas reliability was poor for within- and between-hemicord dorsal-ventral connectivity. Considering how prone spinal cord fMRI is to noise, we extensively investigated the impact of distinct noise sources and made two crucial observations: removal of physiological noise led to a reduction in functional connectivity strength and reliability - due to the removal of stable and participant-specific noise patterns - whereas removal of thermal noise considerably increased the detectability of functional connectivity without a clear influence on reliability. Finally, we also assessed connectivity within spinal cord segments and observed that while the pattern of connectivity was similar to that of whole cervical cord, reliability at the level of single segments was consistently poor. Taken together, our results demonstrate the presence of reliable resting-state functional connectivity in the human spinal cord even after thoroughly accounting for physiological and thermal noise, but at the same time urge caution if focal changes in connectivity (e.g. due to segmental lesions) are to be studied, especially in a longitudinal manner.


Assuntos
Medula Cervical , Medula Espinal , Adulto Jovem , Animais , Humanos , Reprodutibilidade dos Testes , Medula Espinal/diagnóstico por imagem , Medula Espinal/fisiologia , Medula Cervical/fisiologia , Encéfalo , Corno Dorsal da Medula Espinal , Imageamento por Ressonância Magnética/métodos
10.
Magn Reson Med ; 89(4): 1385-1400, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36373175

RESUMO

PURPOSE: Magnetization transfer saturation ( MTsat $$ \mathrm{MTsat} $$ ) is a useful marker to probe tissue macromolecular content and myelination in the brain. The increased B 1 + $$ {B}_1^{+} $$ -inhomogeneity at ≥ 7 $$ \ge 7 $$ T and significantly larger saturation pulse flip angles which are often used for postmortem studies exceed the limits where previous MTsat $$ \mathrm{MTsat} $$ B 1 + $$ {B}_1^{+} $$ correction methods are applicable. Here, we develop a calibration-based correction model and procedure, and validate and evaluate it in postmortem 7T data of whole chimpanzee brains. THEORY: The B 1 + $$ {B}_1^{+} $$ dependence of MTsat $$ \mathrm{MTsat} $$ was investigated by varying the off-resonance saturation pulse flip angle. For the range of saturation pulse flip angles applied in typical experiments on postmortem tissue, the dependence was close to linear. A linear model with a single calibration constant C $$ C $$ is proposed to correct bias in MTsat $$ \mathrm{MTsat} $$ by mapping it to the reference value of the saturation pulse flip angle. METHODS: C $$ C $$ was estimated voxel-wise in five postmortem chimpanzee brains. "Individual-based global parameters" were obtained by calculating the mean C $$ C $$ within individual specimen brains and "group-based global parameters" by calculating the means of the individual-based global parameters across the five brains. RESULTS: The linear calibration model described the data well, though C $$ C $$ was not entirely independent of the underlying tissue and B 1 + $$ {B}_1^{+} $$ . Individual-based correction parameters and a group-based global correction parameter ( C = 1 . 2 $$ C=1.2 $$ ) led to visible, quantifiable reductions of B 1 + $$ {B}_1^{+} $$ -biases in high-resolution MTsat $$ \mathrm{MTsat} $$ maps. CONCLUSION: The presented model and calibration approach effectively corrects for B 1 + $$ {B}_1^{+} $$ inhomogeneities in postmortem 7T data.


Assuntos
Encéfalo , Pan troglodytes , Animais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Calibragem
11.
MAGMA ; 36(2): 191-210, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37029886

RESUMO

Multiple sites within Germany operate human MRI systems with magnetic fields either at 7 Tesla or 9.4 Tesla. In 2013, these sites formed a network to facilitate and harmonize the research being conducted at the different sites and make this technology available to a larger community of researchers and clinicians not only within Germany, but also worldwide. The German Ultrahigh Field Imaging (GUFI) network has defined a strategic goal to establish a 14 Tesla whole-body human MRI system as a national research resource in Germany as the next progression in magnetic field strength. This paper summarizes the history of this initiative, the current status, the motivation for pursuing MR imaging and spectroscopy at such a high magnetic field strength, and the technical and funding challenges involved. It focuses on the scientific and science policy process from the perspective in Germany, and is not intended to be a comprehensive systematic review of the benefits and technical challenges of higher field strengths.


Assuntos
Imageamento por Ressonância Magnética , Imagem Corporal Total , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagem Corporal Total/métodos , Alemanha , Campos Magnéticos
12.
Neuroimage ; 253: 119092, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35288281

RESUMO

Multi-parameter mapping (MPM) magnetic resonance imaging (MRI) provides quantitative estimates of the longitudinal and effective transverse relaxation rates R1 and R2*, proton density (PD), and magnetization transfer saturation (MTsat). Thereby, MPM enables better comparability across sites and time than conventional weighted MRI. However, for MPM, several contrasts must be acquired, resulting in prolonged measurement durations and thus preventing MPM's application in clinical routines. State-of-the-art imaging acceleration techniques such as Compressed SENSE (CS), a combination of compressed sensing and sensitivity encoding, can be used to reduce the scan time of MPM. However, the accuracy and precision of the resulting quantitative parameter maps have not been systematically evaluated. In this study, we therefore investigated the effect of CS acceleration on the fidelity and reproducibility of MPM acquisitions. In five healthy volunteers and in a phantom, we compared MPM metrics acquired without imaging acceleration, with the standard acceleration (SENSE factor 2.5), and with Compressed SENSE with acceleration factors 4 and 6 using a 32-channel head coil. We evaluated the reproducibility and repeatability of accelerated MPM using data from three scan sessions in gray and white matter volumes-of-interest (VOIs). Accelerated MPM provided precise and accurate quantitative parameter maps. For most parameters, the results of the CS-accelerated protocols correlated more strongly with the non-accelerated protocol than the standard SENSE-accelerated protocols. Furthermore, for most VOIs and contrasts, coefficients of variation were lower when calculated from data acquired with different imaging accelerations within a single scan session than from data acquired in different scan sessions with the same acceleration method. These results suggest that MPM with Compressed SENSE acceleration factors up to at least 6 yields reproducible quantitative parameter maps that are highly comparable to those acquired without imaging acceleration. Compressed SENSE can thus be used to considerably reduce the scan duration of R1, R2*, PD, and MTsat mapping, and is highly promising for clinical applications of MPM.


Assuntos
Imageamento por Ressonância Magnética , Prótons , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
Neuroimage ; 264: 119751, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36384206

RESUMO

MRI based multicenter studies which target neurological pathologies affecting the spinal cord and brain - including spinal cord injury (SCI) - require standardized acquisition protocols and image processing methods. We have optimized and applied a multi-parameter mapping (MPM) protocol that simultaneously covers the brain and the cervical cord within a traveling heads study across six clinical centers (Leutritz et al., 2020). The MPM protocol includes quantitative maps (magnetization transfer saturation (MT), proton density (PD), longitudinal (R1), and effective transverse (R2*) relaxation rates) sensitive to myelination, water content, iron concentration, and morphometric measures, such as cross-sectional cord area. Previously, we assessed the repeatability and reproducibility of the brain MPM data acquired in the five healthy participants who underwent two scan-rescans (Leutritz et al., 2020). This study focuses on the cervical cord MPM data derived from the same acquisitions to determine its repeatability and reproducibility in the cervical cord. MPM matrices of the cervical cord were generated and processed using the hMRI and the spinal cord toolbox. To determine reliability of the cervical MPM data, the intra-site (i.e., scan-rescan) coefficient of variation (CoV), inter-site CoV, and bias within region of interests (C1, C2 and C3 levels) were determined. The range of the mean intra- and inter-site CoV of MT, R1 and PD was between 2.5% and 12%, and between 1.1% and 4.0% for the morphometric measures. In conclusion, the cervical MPM data showed a high repeatability and reproducibility for key imaging biomarkers and hence can be employed as a standardized tool in multi-center studies, including clinical trials.


Assuntos
Medula Cervical , Humanos , Medula Cervical/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Transversais , Imageamento por Ressonância Magnética/métodos , Medula Espinal/patologia
14.
Neuroimage ; 247: 118832, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34929383

RESUMO

The accessibility of new wide-scale multimodal imaging techniques led to numerous clearing techniques emerging over the last decade. However, clearing mesoscopic-sized blocks of aged human brain tissue remains an extremely challenging task. Homogenizing refractive indices and reducing light absorption and scattering are the foundation of tissue clearing. Due to its dense and highly myelinated nature, especially in white matter, the human brain poses particular challenges to clearing techniques. Here, we present a comparative study of seven tissue clearing approaches and their impact on aged human brain tissue blocks (> 5 mm). The goal was to identify the most practical and efficient method in regards to macroscopic transparency, brief clearing time, compatibility with immunohistochemical processing and wide-scale multimodal microscopic imaging. We successfully cleared 26 × 26 × 5 mm3-sized human brain samples with two hydrophilic and two hydrophobic clearing techniques. Optical properties as well as light and antibody penetration depths highly vary between these methods. In addition to finding the best clearing approach, we compared three microscopic imaging setups (the Zeiss Laser Scanning Microscope (LSM) 880 , the Miltenyi Biotec Ultramicroscope ll (UM ll) and the 3i Marianas LightSheet microscope) regarding optimal imaging of large-scale tissue samples. We demonstrate that combining the CLARITY technique (Clear Lipid-exchanged Acrylamide-hybridized Rigid Imaging compatible Tissue hYdrogel) with the Zeiss LSM 880 and combining the iDISCO technique (immunolabeling-enabled three-dimensional imaging of solvent-cleared organs) with the Miltenyi Biotec UM ll are the most practical and efficient approaches to sufficiently clear aged human brain tissue and generate 3D microscopic images. Our results point out challenges that arise from seven clearing and three imaging techniques applied to non-standardized tissue samples such as aged human brain tissue.


Assuntos
Envelhecimento/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imagem Multimodal , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional , Imuno-Histoquímica , Masculino , Microscopia Confocal , Microscopia de Fluorescência , Pessoa de Meia-Idade , Imagem Óptica/métodos
15.
Neuroimage ; 249: 118906, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35032659

RESUMO

Non-invasive assessment of axon radii via MRI bears great potential for clinical and neuroscience research as it is a main determinant of the neuronal conduction velocity. However, there is a lack of representative histological reference data at the scale of the cross-section of MRI voxels for validating the MRI-visible, effective radius (reff). Because the current gold standard stems from neuroanatomical studies designed to estimate the bulk-determined arithmetic mean radius (rarith) on small ensembles of axons, it is unsuited to estimate the tail-weighted reff. We propose CNN-based segmentation on high-resolution, large-scale light microscopy (lsLM) data to generate a representative reference for reff. In a human corpus callosum, we assessed estimation accuracy and bias of rarith and reff. Furthermore, we investigated whether mapping anatomy-related variation of rarith and reff is confounded by low-frequency variation of the image intensity, e.g., due to staining heterogeneity. Finally, we analyzed the error due to outstandingly large axons in reff. Compared to rarith, reff was estimated with higher accuracy (maximum normalized-root-mean-square-error of reff: 8.5 %; rarith: 19.5 %) and lower bias (maximum absolute normalized-mean-bias-error of reff: 4.8 %; rarith: 13.4 %). While rarith was confounded by variation of the image intensity, variation of reff seemed anatomy-related. The largest axons contributed between 0.8 % and 2.9 % to reff. In conclusion, the proposed method is a step towards representatively estimating reff at MRI voxel resolution. Further investigations are required to assess generalization to other brains and brain areas with different axon radii distributions.


Assuntos
Axônios/ultraestrutura , Microscopia/métodos , Neuroimagem/métodos , Substância Branca/diagnóstico por imagem , Substância Branca/ultraestrutura , Idoso , Idoso de 80 Anos ou mais , Aprendizado Profundo , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
16.
Neuroimage ; 262: 119529, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-35926761

RESUMO

Multi-Parameter Mapping (MPM) is a comprehensive quantitative neuroimaging protocol that enables estimation of four physical parameters (longitudinal and effective transverse relaxation rates R1 and R2*, proton density PD, and magnetization transfer saturation MTsat) that are sensitive to microstructural tissue properties such as iron and myelin content. Their capability to reveal microstructural brain differences, however, is tightly bound to controlling random noise and artefacts (e.g. caused by head motion) in the signal. Here, we introduced a method to estimate the local error of PD, R1, and MTsat maps that captures both noise and artefacts on a routine basis without requiring additional data. To investigate the method's sensitivity to random noise, we calculated the model-based signal-to-noise ratio (mSNR) and showed in measurements and simulations that it correlated linearly with an experimental raw-image-based SNR map. We found that the mSNR varied with MPM protocols, magnetic field strength (3T vs. 7T) and MPM parameters: it halved from PD to R1 and decreased from PD to MTsat by a factor of 3-4. Exploring the artefact-sensitivity of the error maps, we generated robust MPM parameters using two successive acquisitions of each contrast and the acquisition-specific errors to down-weight erroneous regions. The resulting robust MPM parameters showed reduced variability at the group level as compared to their single-repeat or averaged counterparts. The error and mSNR maps may better inform power-calculations by accounting for local data quality variations across measurements. Code to compute the mSNR maps and robustly combined MPM maps is available in the open-source hMRI toolbox.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Artefatos , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Neuroimagem/métodos
17.
Neuroimage ; 254: 118958, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35217204

RESUMO

Tremendous efforts have been made in the last decade to advance cutting-edge MRI technology in pursuit of mapping structural connectivity in the living human brain with unprecedented sensitivity and speed. The first Connectom 3T MRI scanner equipped with a 300 mT/m whole-body gradient system was installed at the Massachusetts General Hospital in 2011 and was specifically constructed as part of the Human Connectome Project. Since that time, numerous technological advances have been made to enable the broader use of the Connectom high gradient system for diffusion tractography and tissue microstructure studies and leverage its unique advantages and sensitivity to resolving macroscopic and microscopic structural information in neural tissue for clinical and neuroscientific studies. The goal of this review article is to summarize the technical developments that have emerged in the last decade to support and promote large-scale and scientific studies of the human brain using the Connectom scanner. We provide a brief historical perspective on the development of Connectom gradient technology and the efforts that led to the installation of three other Connectom 3T MRI scanners worldwide - one in the United Kingdom in Cardiff, Wales, another in continental Europe in Leipzig, Germany, and the latest in Asia in Shanghai, China. We summarize the key developments in gradient hardware and image acquisition technology that have formed the backbone of Connectom-related research efforts, including the rich array of high-sensitivity receiver coils, pulse sequences, image artifact correction strategies and data preprocessing methods needed to optimize the quality of high-gradient strength diffusion MRI data for subsequent analyses. Finally, we review the scientific impact of the Connectom MRI scanner, including advances in diffusion tractography, tissue microstructural imaging, ex vivo validation, and clinical investigations that have been enabled by Connectom technology. We conclude with brief insights into the unique value of strong gradients for diffusion MRI and where the field is headed in the coming years.


Assuntos
Conectoma , Encéfalo/diagnóstico por imagem , China , Conectoma/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Humanos
18.
Hum Brain Mapp ; 43(11): 3585-3603, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35397153

RESUMO

We investigate the reliability of individual differences of four quantities measured by magnetic resonance imaging-based multiparameter mapping (MPM): magnetization transfer saturation (MT), proton density (PD), longitudinal relaxation rate (R1 ), and effective transverse relaxation rate (R2 *). Four MPM datasets, two on each of two consecutive days, were acquired in healthy young adults. On Day 1, no repositioning occurred and on Day 2, participants were repositioned between MPM datasets. Using intraclass correlation effect decomposition (ICED), we assessed the contributions of session-specific, day-specific, and residual sources of measurement error. For whole-brain gray and white matter, all four MPM parameters showed high reproducibility and high reliability, as indexed by the coefficient of variation (CoV) and the intraclass correlation (ICC). However, MT, PD, R1 , and R2 * differed markedly in the extent to which reliability varied across brain regions. MT and PD showed high reliability in almost all regions. In contrast, R1 and R2 * showed low reliability in some regions outside the basal ganglia, such that the sum of the measurement error estimates in our structural equation model was higher than estimates of between-person differences. In addition, in this sample of healthy young adults, the four MPM parameters showed very little variability over four measurements but differed in how well they could assess between-person differences. We conclude that R1 and R2 * might carry only limited person-specific information in some regions of the brain in healthy young adults, and, by implication, might be of restricted utility for studying associations to between-person differences in behavior in those regions.


Assuntos
Imageamento por Ressonância Magnética , Prótons , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Mapeamento Encefálico , Humanos , Reprodutibilidade dos Testes , Adulto Jovem
19.
Hum Brain Mapp ; 43(18): 5389-5407, 2022 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-35938527

RESUMO

Functional magnetic resonance imaging (fMRI) of the human spinal cord faces many challenges, such as signal loss due to local magnetic field inhomogeneities. This issue can be addressed with slice-specific z-shimming, which compensates for the dephasing effect of the inhomogeneities using a slice-specific gradient pulse. Here, we aim to address outstanding issues regarding this technique by evaluating its effects on several aspects that are directly relevant for spinal fMRI and by developing two automated procedures in order to improve upon the time-consuming and subjective nature of manual selection of z-shims: one procedure finds the z-shim that maximizes signal intensity in each slice of an EPI reference-scan and the other finds the through-slice field inhomogeneity for each EPI-slice in field map data and calculates the required compensation gradient moment. We demonstrate that the beneficial effects of z-shimming are apparent across different echo times, hold true for both the dorsal and ventral horn, and are also apparent in the temporal signal-to-noise ratio (tSNR) of EPI time-series data. Both of our automated approaches were faster than the manual approach, lead to significant improvements in gray matter tSNR compared to no z-shimming and resulted in beneficial effects that were stable across time. While the field-map-based approach performed slightly worse than the manual approach, the EPI-based approach performed as well as the manual one and was furthermore validated on an external corticospinal data-set (N > 100). Together, automated z-shimming may improve the data quality of future spinal fMRI studies and lead to increased reproducibility in longitudinal studies.


Assuntos
Artefatos , Imagem Ecoplanar , Humanos , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Encéfalo/diagnóstico por imagem
20.
Magn Reson Med ; 88(2): 787-801, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35405027

RESUMO

PURPOSE: High-resolution quantitative multi-parameter mapping shows promise for non-invasively characterizing human brain microstructure but is limited by physiological artifacts. We implemented corrections for rigid head movement and respiration-related B0-fluctuations and evaluated them in healthy volunteers and dementia patients. METHODS: Camera-based optical prospective motion correction (PMC) and FID navigator correction were implemented in a gradient and RF-spoiled multi-echo 3D gradient echo sequence for mapping proton density (PD), longitudinal relaxation rate (R1) and effective transverse relaxation rate (R2*). We studied their effectiveness separately and in concert in young volunteers and then evaluated the navigator correction (NAVcor) with PMC in a group of elderly volunteers and dementia patients. We used spatial homogeneity within white matter (WM) and gray matter (GM) and scan-rescan measures as quality metrics. RESULTS: NAVcor and PMC reduced artifacts and improved the homogeneity and reproducibility of parameter maps. In elderly participants, NAVcor improved scan-rescan reproducibility of parameter maps (coefficient of variation decreased by 14.7% and 11.9% within WM and GM respectively). Spurious inhomogeneities within WM were reduced more in the elderly than in the young cohort (by 9% vs. 2%). PMC increased regional GM/WM contrast and was especially important in the elderly cohort, which moved twice as much as the young cohort. We did not find a significant interaction between the two corrections. CONCLUSION: Navigator correction and PMC significantly improved the quality of PD, R1, and R2* maps, particularly in less compliant elderly volunteers and dementia patients.


Assuntos
Demência , Imageamento por Ressonância Magnética , Idoso , Artefatos , Encéfalo/diagnóstico por imagem , Humanos , Movimento (Física) , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA