Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Eur Heart J ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

2.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35385588

RESUMO

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Tricúspide , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Valva Tricúspide/cirurgia
3.
Thorac Cardiovasc Surg ; 68(6): 503-506, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31683327

RESUMO

Severe tricuspid regurgitation constitutes a growing disease burden. Conventional surgery for tricuspid valve disease has an increased risk while several interventional procedures are currently under clinical investigation, yet do not offer comprehensive solutions. We investigated a novel surgical approach for off-pump beating-heart tricuspid annuloplasty in circulating blood through a single port in the right atrium. Early feasibility results in preclinical porcine in vivo studies encourage further development of this approach, combining the proven concept of surgical annuloplasty with the benefits of minimally invasive off-pump procedures in a hybrid setting.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Animais , Cadáver , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/instrumentação , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Modelos Animais , Sus scrofa , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
5.
J Card Surg ; 34(10): 1140-1142, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31389639

RESUMO

Quadruple valve surgery represents a complex and rare surgical procedure, requiring a systematic and standardized approach. In this intervention, pulmonary valve replacement (PVR) in patients without pre-existing congenital heart disease represents a challenge and no large data have been reported yet. We hereby report a case of bioprosthetic PVR in an octogenarian within a quadruple valve procedure, illustrating our preferred technique of PVR with bioprosthetic implantation and right ventricular outflow tract reconstruction.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia , Humanos , Masculino , Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico , Doenças Raras , Reoperação
7.
Ann Pharmacother ; 50(1): 27-31, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26497885

RESUMO

BACKGROUND: To date, there is limited literature regarding the association between dipeptidyl peptidase-4 (DPP-4) inhibitors and pancreatic carcinoma. OBJECTIVE: To describe the comparative incidence of DPP-4 inhibitors and pancreatic carcinoma as reportedly available in the Food and Drug Administration (FDA) Adverse Event Reporting System (FAERS) database. The goal was to provide health care practitioners a general understanding of the drug-disease occurrence. METHODS: This is a case/noncase study utilizing Empirica Signal software to query FAERS from November 1968 to December 31, 2013. The software was used to calculate a disproportionality statistic--namely, the empirical Bayesian geometric mean (EBGM)--for reports of DPP-4 inhibitors-associated pancreatic carcinoma. The FDA considers an EBGM significant if the fifth percentile of the distribution is at least 2, defined as an EB05 ≥ 2. With use of a disproportionality analysis, DPP-4 inhibitors were compared with all agents listed in FAERS. RESULTS: A total of 156 patients experienced pancreatic carcinoma while receiving DPP-4 inhibitor therapy. An EB05 of 10.3 was determined for sitagliptin, 7.1 for saxagliptin, 4.9 for linagliptin, and 1.4 for alogliptin, compared with all other agents included in FAERS. Although an EB05 > 2 was achieved in 2 other antihyperglycemic agents, the findings were not consistent within their medication classes. CONCLUSION: There appears to be a statistical association between DPP-4 inhibitor use and pancreatic carcinoma. Causality cannot be inferred from the data provided. Additional clinical studies are needed to further explore this statistical association.


Assuntos
Sistemas de Notificação de Reações Adversas a Medicamentos , Inibidores da Dipeptidil Peptidase IV/efeitos adversos , Neoplasias Pancreáticas/induzido quimicamente , Teorema de Bayes , Bases de Dados Factuais , Humanos , Estados Unidos , United States Food and Drug Administration , Neoplasias Pancreáticas
9.
Consult Pharm ; 31(5): 251-60, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27178654

RESUMO

OBJECTIVE: To review the chemistry, pharmacology, pharmacodynamics, pharmacokinetics, clinical efficacy, tolerability, dosing, drug interactions, and administration of canagliflozin, dapagliflozin, and empagliflozin, and comparing the benefit and risk aspects of using these agents in the older adult diabetes patient population. DATA SOURCES, STUDY SELECTION, DATA EXTRACTION, AND DATA SYNTHESIS: A search of PubMed using the terms "SGLT-2 inhibitors," "canagliflozin," "dapagliflozin," "empagliflozin," "efficacy," and "tolerability" was performed to find relevant primary literature on each of the sodium/glucose cotransporter 2 (SGLT-2) inhibitors currently approved for use in type 2 diabetes. Phase III trials for all agents were included. All English-language articles from 2010 to 2015 appearing in these searches were reviewed for relevance to this paper. In addition, related articles suggested in the PubMed search were also reviewed. The SGLT-2 inhibitors have shown a reduction in hemoglobin A1c values and fasting plasma glucose levels with a low incidence of hypoglycemia. The incidence of mycotic infections is increased in patients taking an SGLT-2 inhibitor. CONCLUSION: SGLT-2 inhibitors may be a viable treatment option for patients not controlled on other oral agents. The risk of hypoglycemia is small. However, the clinical efficacy and tolerability of these agents has not been fully elucidated in older and frail patients.


Assuntos
Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Inibidores do Transportador 2 de Sódio-Glicose , Idoso , Compostos Benzidrílicos/efeitos adversos , Compostos Benzidrílicos/farmacologia , Compostos Benzidrílicos/uso terapêutico , Glicemia/efeitos dos fármacos , Canagliflozina/efeitos adversos , Canagliflozina/farmacologia , Canagliflozina/uso terapêutico , Diabetes Mellitus Tipo 2/fisiopatologia , Glucosídeos/efeitos adversos , Glucosídeos/farmacologia , Glucosídeos/uso terapêutico , Humanos , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/farmacologia , Transportador 2 de Glucose-Sódio
10.
Ann Thorac Surg ; 117(2): 474-478, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37890817

RESUMO

PURPOSE: A new automated expanded polytetrafluoroethylene (ePTFE) suture placement device and a new customized titanium fastener deployment device were clinically evaluated in open and less-invasive mitral valve repair (MVr). DESCRIPTION: Twelve patients were monitored for 1 year after undergoing MVr using the study devices. The study end points included surgical outcomes, operative times, valve repair durability, adverse events, and mortality. EVALUATION: Three patients received 1 ePTFE chord using the study technology, and 9 patients received 2 chords. Mitral regurgitation at 30 days was absent in 8 patients, trace in 2, and mild in 2. At the 1-year follow-up, mitral regurgitation was absent in 7 patients, trace in 2, mild in 2, and moderate in 1. There were no replacement chord failures, reoperations, or death. CONCLUSIONS: The initial outcomes of new automated ePTFE suture placement and titanium fastener deployment devices encourage further clinical evaluations.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/etiologia , Valva Mitral/cirurgia , Titânio , Resultado do Tratamento , Suturas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cordas Tendinosas/cirurgia
11.
J Clin Med ; 13(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38892924

RESUMO

Objectives: Mitral valve repair is the current standard approach for mitral valve regurgitation. However, patients suffering from functional mitral regurgitation have a significant risk of recurrent regurgitation. Adjustable mitral rings may provide a solution for this adverse event. Methods: A single-center, first-in-man clinical study was performed on patients suffering from mitral valve regurgitation. Patients were implanted with the study ring and followed for six months. A balloon catheter can be inserted into the study ring frame at any time after implantation and inflated independently in the areas P1, P2, or P3, which reduces the anterior-posterior diameter. Results: Five patients (75.4 ± 6.1 years; EuroSCORE II 2.1 ± 0.9%; three female) were successfully implanted. Mechanisms of mitral regurgitation were prolapse of the P2-segment in three patients and annular dilation in two patients. Surgical implantation according to the protocol was feasible and is described herein. Median cardiopulmonary bypass time and cross clamp time were 105 (118; 195) and 94 (90; 151) min, respectively. The median intensive care unit stay was 2 (2; 3) days. No perioperative, 30-day, or 6-month mortality was observed, and the repair was stable without residual or recurrent regurgitation ≥ grade 2. All patients reached the primary endpoint without device-related morbidity. Conclusions: Successful implantation was completed in five patients without device-related adverse events. Ring implantation was safe and feasible for all patients. The opportunity of post-implant adjustment to improve leaflet coaptation is a promising new therapeutic strategy that is assessed in a phase II study.

12.
Clin Cardiol ; 47(2): e24197, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069663

RESUMO

BACKGROUND: Postinterventional sonographic assessment of the femoral artery after transfemoral transcatheter aortic valve replacement (TF-TAVR) has the potential to identify several pathologies. We investigated the incidence and risk factors of femoral vessel complications in a modern TAVR collective using postinterventional sonography. METHODS: Between September 2017 and March 2022, 480 patients underwent TF-TAVR with postinterventional femoral sonography at a single center. Clinical outcomes and adverse events were analyzed after the Valve Academic Research Consortium 3 (VARC-3) criteria. RESULTS: In this cohort (51.2% male; age 80 ± 7.5 years, median EuroSCORE II 3.7) 74.8% (n = 359) were implanted with a self-expandable and 25.2% (n = 121) with a balloon-expandable valve. The main access (valve-delivery) was located right in 91.4% (n = 438), and the primary closure system was Proglide in 95% (n = 456). Vascular complications (VC) were observed in 29.16% (n = 140) of patients; 23.3% (n = 112) presented with minor- and 5.8% (n = 28) with major VC. Postinterventional femoral artery stenosis on the main access was observed in 9.8% (n = 47). Multivariable logistic regression analysis revealed female sex (p = .03, odds ratio [OR] 2.32, 95% confidence interval [CI] 1.09-4.89) and the number of used endovascular closure devices (p = .014, OR 0.11, 95%CI 0.02-0.64) as predictive factors for femoral artery stenosis. CONCLUSIONS: The incidence of postinterventional femoral artery stenosis following TF-TAVR was higher than expected with a number of used closure devices and female sex being independent risk factors. Considering the continuous advance of TAVR in low-risk patients with preserved physical activity, emphasis should be directed at the correct diagnosis and follow-up of these complications.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças Vasculares , Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Resultado do Tratamento , Fatores de Risco , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estudos Retrospectivos
13.
Front Cardiovasc Med ; 11: 1363336, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322769

RESUMO

Objectives: To date, there is no evidence regarding the safety of automated titanium fastener compared with hand-tied knots for prosthesis fixation in infective endocarditis. Methods: Between January 2016 and December 2022, a total of 220 patients requiring surgery for infective endocarditis were included in this retrospective analysis. The primary study endpoint was re-endocarditis during follow-up. The secondary study endpoints included stroke onset, all-cause mortality, and a composite outcome of either re-endocarditis, stroke, or all-cause mortality during follow-up. Results: Suture-securing with an automated titanium fastener was performed in 114 (51.8%) patients, whereas the conventional technique of hand knot-tying was used in 106 (48.2%) patients. The risk of re-endocarditis was significantly lower in the automated titanium fastener group, as shown in a multivariable proportional competing risk regression model (adjusted sub-hazard ratio 0.33, 95% confidence interval 0.11-0.99, p = 0.048). The multivariable Cox proportional hazards regression analysis showed that the automated titanium fastener group was not associated with an increased risk of stroke-onset or attaining the composite outcome, respectively, (adjusted hazard ratio 0.54, 95% confidence interval 0.27-1.08, p = 0.082), (adjusted hazard ratio 0.65, 95% confidence interval 0.42-1.02, p = 0.061). Also, this group was not associated with an increased risk of all-cause mortality, as demonstrated in the multivariable Poisson regression analysis (adjusted incidence-rate ratio 1.42, 95% confidence interval 0.83-2.42, p = 0.202). Conclusions: The use of automated titanium fastener device seems to be safe for infective endocarditis. Analyses of larger cohorts are required.

14.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38913864

RESUMO

OBJECTIVES: Evidence on long-term clinical outcomes considering suture-securing techniques used for surgical aortic valve replacement is still uncertain. METHODS: A total of 1405 patients who underwent surgical aortic valve replacement between January 2016 and December 2022 were included and grouped according to the suture-securing technique used (automated titanium fastener versus hand-tied knots). The occurrence of infective endocarditis during follow-up was set as the primary study end-point. As secondary study end-points, stroke, all-cause mortality and a composite outcome of either infective endocarditis, stroke, or all-cause mortality were assessed. RESULTS: The automated titanium fastener was used in 829 (59%) patients, whereas the hand-knot tying technique was used in 576 (41%) patients. The multivariable proportional competing risk regression analysis showed a significantly lower risk of infective endocarditis during follow-up in the automated titanium fastener group (adjusted sub-hazard ratio 0.44, 95% confidence interval 0.20-0.94, P = 0.035). The automated titanium fastener group was not associated with an increased risk of mortality or attaining the composite outcome, respectively (adjusted hazard ratio 0.81, 95% confidence interval 0.60-1.09, P = 0.169; adjusted hazard ratio 0.82, 95% confidence interval 0.63-1.07, P = 0.152). This group was not associated with an increased risk of stroke (adjusted sub-hazard ratio 0.82, 95% confidence interval 0.47-1.45, P = 0.504). Also, a significantly lower rate of early-onset infective endocarditis was observed in the automated titanium fastener group, (0.4% vs 1.4%, P = 0.032). CONCLUSIONS: Suture-securing with an automated titanium fastener device appears to be superior compared to the hand-knot tying technique in terms of lower risk of infective endocarditis.


Assuntos
Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Técnicas de Sutura , Titânio , Humanos , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Aórtica/cirurgia , Endocardite/prevenção & controle , Técnicas de Sutura/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos
15.
Ann Surg ; 257(5): 834-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23574990

RESUMO

OBJECTIVE: To determine the factors that may predict music-induced relaxation in friends and family of patients in the emergency department. BACKGROUND: It remains unclear to date which demographic and experiential factors predict the effectiveness of music-induced relaxation. Furthermore, in-hospital stressors for friends and family of patients rather than patients themselves are underresearched and deserve in-depth investigation to improve this group's experience in health care environments. METHODS: A total of 169 relatives and friends of patients in the emergency department-waiting area completed a series of questionnaires, including the Spielberger State-Trait Anxiety Inventory (STAI), the Music Experience Questionnaire (MEQ), and a demographic survey. They were then randomly assigned to either Case Group (1 hour in the waiting area with classical music in the background) or Control Group (1 hour with no music) before completing a second, identical copy of the STAI to measure change from baseline. Data were analyzed for associations between music intervention, change in STAI scores, MEQ scores, and demographic characteristics. RESULTS: Participants who underwent the music intervention experienced a 9.8% decrease in overall mean State Anxiety, whereas those in the Control Group experienced no change over time (P = 0.001). Higher education significantly inversely correlated with the effectiveness of music intervention: participants with no formal education beyond high school showed a greater overall mean decrease in State Anxiety than those with a college education or beyond in response to classical music (P = 0.006). Furthermore, MEQ scores indicated that the Social Uplift scale (a measure of one's tendency to be uplifted in a group-oriented manner by music) was highly predictive of the effectiveness of music intervention. CONCLUSIONS: Music is an effective and inexpensive means of reducing anxiety in friends and family of patients, who are underresearched in medicine. Moreover, low educational attainment and tendency to respond positively to music in a group setting can predict the effectiveness of music-induced relaxation.


Assuntos
Ansiedade/terapia , Serviço Hospitalar de Emergência , Família/psicologia , Amigos/psicologia , Musicoterapia , Estresse Psicológico/terapia , Adulto , Ansiedade/etiologia , Método Duplo-Cego , Escolaridade , Feminino , Humanos , Masculino , Musicoterapia/métodos , Estresse Psicológico/etiologia , Inquéritos e Questionários , Resultado do Tratamento
16.
J Clin Med ; 12(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959179

RESUMO

BACKGROUND: decellularized aortic homografts (DAH) represent a promising alternative for aortic valve replacement in young adults due to their low immunogenicity and thrombogenicity. Herein, we report our midterm, single-center experience in adult patients with non-frozen DAH from corlife. METHODS: safety, durability, and hemodynamic performance were evaluated according to current guidelines in all consecutive patients who had received a DAH at our center since 03/2016. RESULTS: seventy-three (mean age 47 ± 11 years, 68.4% (n = 50) male) patients were enrolled. The mean diameter of the implanted DAH was 24 ± 2 mm. Mean follow-up was 36 ± 27 months, with a maximum follow-up of 85 months and cumulative follow-up of 215 years. No cases of stenosis were observed, in four (5.5%) cases moderate aortic regurgitation occurred, but no reintervention was required. No cases of early mortality, non-structural dysfunction, reoperation, valve endocarditis, or thrombosis were observed. Freedom from bleeding and thromboembolic events was 100%; freedom from re-intervention was 100%; survival was 98.6% (n = 72). CONCLUSIONS: early and mid-term results showed low mortality and 100% freedom from reoperation, thromboembolic events, and bleeding at our center. However, in order for this novel approach to be established as a valid alternative to aortic valve replacement in young patients, long-term data are required.

17.
J Thorac Cardiovasc Surg ; 166(6): 1635-1643.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37263524

RESUMO

OBJECTIVES: Biological composite valve grafts (CVGs) are being performed more frequently, which increases the need for interventions treating bioprosthetic valve failure. The feasibility of valve-in-valve procedures in this population is uncertain. This study aimed to assess changes in aortic root geometry and coronary height following CVG implantation to better understand future interventions. METHODS: We retrospectively identified 64 patients following bioprosthetic CVG replacement with pre- and postoperative computed tomography angiography. Root assessment was conducted as in preprocedural transcatheter aortic valve evaluation using a virtual valve simulation. RESULTS: In 64 patients (age, 67.6 ± 9.3 years; 76.6% men) the preoperative coronary height was 14.3 ± 6.8 mm for the left coronary artery (LCA) and 17.9 ± 5.9 mm for the right coronary artery (RCA), which significantly decreased after CVG implantation, with 8.7 ± 4.4 mm for the LCA and 11.3 ± 4.4 mm for the RCA (P < .001). The virtual valve-to-coronary distances measured 4.0 ± 1.3 mm (LCA) and 4.6 ± 1.4 mm (RCA). Overall, 59.4% (n = 38) of patients with bio-CVGs would have been at risk for coronary obstruction, 29.7% (n = 19) for LCA, 10.9% (n = 7) for RCA, and 18.8% (n = 12) for combined LCA and RCA. CONCLUSIONS: Coronary height significantly decreased following CVG implantation. The majority of patients after bio-CVG were at a potential risk for coronary obstruction in future valve-in-valve procedures. Further studies are needed to identify the best possible technique for coronary reimplantation and other measures to diminish the risk for future coronary obstruction in this population.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Estudos Retrospectivos , Aorta/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Oclusão Coronária/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia
18.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225288

RESUMO

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Assuntos
Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Sistema de Registros
19.
Ann Surg ; 255(6): 1190-4, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22584632

RESUMO

OBJECTIVE: To explore how the 2 most important components of surgical performance--speed and accuracy-are influenced by different forms of stress and what the impact of music is on these factors. BACKGROUND: On the basis of a recently published pilot study on surgical experts, we designed an experiment examining the effects of auditory stress, mental stress, and music on surgical performance and learning and then correlated the data psychometric measures to the role of music in a novice surgeon's life. METHODS: Thirty-one surgeons were recruited for a crossover study. Surgeons were randomized to 4 simple standardized tasks to be performed on the SurgicalSIM VR laparoscopic simulator (Medical Education Technologies, Inc, Sarasota, FL), allowing exact tracking of speed and accuracy. Tasks were performed under a variety of conditions, including silence, dichotic music (auditory stress), defined classical music (auditory relaxation), and mental loading (mental arithmetic tasks). Tasks were performed twice to test for memory consolidation and to accommodate for baseline variability. Performance was correlated to the brief Musical Experience Questionnaire (MEQ). RESULTS: Mental loading influences performance with respect to accuracy, speed, and recall more negatively than does auditory stress. Defined classical music might lead to minimally worse performance initially but leads to significantly improved memory consolidation. Furthermore, psychologic testing of the volunteers suggests that surgeons with greater musical commitment, measured by the MEQ, perform worse under the mental loading condition. CONCLUSIONS: Mental distraction and auditory stress negatively affect specific components of surgical learning and performance. If used appropriately, classical music may positively affect surgical memory consolidation. It also may be possible to predict surgeons' performance and learning under stress through psychological tests on the role of music in a surgeon's life. Further investigation is necessary to determine the cognitive processes behind these correlations.


Assuntos
Laparoscopia/educação , Laparoscopia/psicologia , Musicoterapia , Melhoria de Qualidade , Análise e Desempenho de Tarefas , Estudos Cross-Over , Educação Médica , Educação de Pós-Graduação em Medicina , Humanos , Som , Estresse Fisiológico , Estresse Psicológico
20.
Eur J Cardiothorac Surg ; 61(2): 416-424, 2022 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-34738111

RESUMO

OBJECTIVES: Long-term durability of surgical bio-prostheses is a key factor, especially in the era of transcatheter aortic valve replacement. We compared the incidence of structural valve deterioration (SVD) between patients undergoing surgical aortic valve replacement (SAVR) with the Trifecta (Abbott Laboratories, Abbott Park, IL, USA) or the Intuity valve (Edwards Lifesciences, Irvine, CA, USA). METHODS: Between April 2010 and May 2020, 1118 patients underwent SAVR with the Trifecta (n = 346) and the Intuity (n = 772) valve at a single centre. A total of 1070 patients (Trifecta n = 298, Intuity n = 772) were analysed after the exclusion of patients with pure regurgitation and endocarditis. Retro- and prospective echocardiographic and clinical follow-up was performed. Cox proportional hazards regression models were performed to identify prognostic factors for SVD, aortic re-interventions and mortality. RESULTS: With 27 cases (Trifecta n = 23, Intuity n = 4) of SVD observed, cumulative incidence of SVD was significantly higher in the Trifecta cohort (P < 0.001). Implantation of a Trifecta valve [hazard ratio (HR) 11.20; 95% confidence interval 3.79-33.09], log-transformed preoperative creatinine (HR 2.47; 1.37-4.44) and sex (male HR 0.42; 0.19-0.92) emerged as prognostic factors of SVD. A significantly higher cumulative incidence of re-interventions was observed in the Trifecta cohort (P = 0.004) and valve type was an independent time-varying risk factor (HR at 12 months 2.78; 95% confidence interval 1.42-5.45). Overall, no significant differences in all-cause mortality were observed between the groups (log-rank test: P = 0.052). CONCLUSIONS: SVD was significantly more frequent in patients receiving a Trifecta valve and its implantation was an independent risk factor for the occurrence of SVD and aortic valve re-interventions. This comparative analysis of 2 low-gradient bioprosthesis put the long-term durability of the Trifecta valve in question and need to be taken into consideration when performing bioprosthetic SAVR.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA