Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Skin Res Technol ; 30(7): e13818, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38924131

RESUMO

BACKGROUND: To date, there are no accepted outcome measures to monitor morphea, and consensus on specific monitoring criteria for morphea remains elusive. A few studies have assessed the criterion validity of skin ultrasound in morphea. So, in this study, we approach ultrasound findings in morphea lesions. MATERIAL AND METHODS: This was a retrospective-analytical study conducted between December 2021 and May 2023. Patients were clinically evaluated at a dermatology outpatient clinic and then referred for high-frequency ultrasound (HF-US) evaluation and were selected to be included in this study. The lesions were confirmed by histopathology as well. Sonographic evaluations were performed on the lesion site and the symmetrical uninvolved other side. Dermal thickness and dermal echogenicities were recorded. Statistical analysis of group differences was performed by using the 2-tailed Student t-test. A p-value of less than 0.05 was considered statistically significant. RESULTS: Forty-one morphea lesions in the inflammatory phase of 27 patients were included in the study. The mean dermal thickness of morphea lesions was 1107.97 ± 414.3 and the mean dermal thickness of the control side was 1094.65 ± 331.06, The difference between these two variables was not statistically significant. The mean dermal density of lesions was 49.13 ± 18.97 and the mean dermal density of the control side was 52.22 ± 25.33. The difference between these two variables was not statistically significant. CONCLUSION: This study shows that HF-US indicated increasing dermal thickness and reducing the dermal density of the morphea lesions in the inflammatory phase confirmed with the histopathology.


Assuntos
Esclerodermia Localizada , Ultrassonografia , Humanos , Esclerodermia Localizada/diagnóstico por imagem , Esclerodermia Localizada/patologia , Estudos Retrospectivos , Feminino , Masculino , Ultrassonografia/métodos , Adulto , Pessoa de Meia-Idade , Adolescente , Adulto Jovem , Pele/diagnóstico por imagem , Pele/patologia , Criança
2.
Dermatol Surg ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39074141

RESUMO

BACKGROUND: Mannitol may be a good excipient for hyaluronic acid (HA) filler. OBJECTIVE: This study aimed to assess the tolerability and effectiveness of a mannitol-containing HA filler for the improvement of nasolabial folds (NLFs). PATIENTS AND METHODS: Thirty Middle Eastern participants aged 18 to 65 years with moderate-to-severe NLFs on the Wrinkle Severity Rating Scale (WSRS) received 1 to 2 mL of a HA filler containing mannitol in both NLFs. Wrinkle Severity Rating Scale; volume, depth, and area of NLFs; and ultrasound parameters were measured at baseline, Weeks 2, 12, and 24 after the injection. Adverse events and participants' satisfaction were recorded in all follow-up visits. RESULTS: Eighty-nine percent, 86%, and 61% of participants showed at least one grade improvement in WSRS, at Weeks 2, 12, and 24, respectively. The area and volume of NLFs significantly decreased compared with baseline (p-value < .01). In severe NLFs, echo density of the dermis significantly increased at Week 2. Participants reported great satisfaction with the treatment, and adverse events were mainly mild and transient. One patient had significant pain during injection, but this resolved without sequelae. CONCLUSION: The tested mannitol-containing HA filler showed to be effective in Middle Eastern participants. The safety will require a follow-up larger study.

3.
Dermatol Ther ; 35(9): e15699, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35808917

RESUMO

Cutaneous leishmaniasis (CL) is a skin disease caused by intracellular protozoa, which is endemic in Iran. The goal of this study was to compare biophysical characteristics in CL lesions with uninvolved skin. Stratum corneum hydration, transepidermal water loss, surface friction, pH, sebum, melanin, erythema, temperature, elasticity parameters (R0, R2, and R5), thickness and echo-density of epidermis and dermis were measured on the active erythematous indurated part of a typical CL lesion in 20 patients, and compared with the same location on the other side of the body as control. Paired t-test was used for statistical analyses and a p < 0.05 was considered significant. Melanin content, R2 and echo-density of dermis were significantly lower, whereas transepidermal water loss, friction index, pH, erythema index, temperature, and the thickness of dermis were significantly higher in CL lesions. There was no significant difference in stratum corneum hydration, sebum, R0, R5, thickness of epidermis, and density of epidermis between CL and normal skin. CL lesions are characterized by certain changes in biophysical and ultrasonographic properties, which are mostly correlated with histological features. These changes are likely to be useful in the non-invasive early detection of CL and also as treatment outcome measures for clinical trials of new treatment modalities for CL in the future.


Assuntos
Leishmaniose Cutânea , Melaninas , Eritema , Humanos , Leishmaniose Cutânea/diagnóstico por imagem , Leishmaniose Cutânea/patologia , Avaliação de Resultados em Cuidados de Saúde , Pele/diagnóstico por imagem , Pele/patologia , Água
4.
Skin Res Technol ; 27(6): 1029-1034, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33974716

RESUMO

BACKGROUND: The goal of this study was evaluation of the skin biophysical properties in early patch/plaque stage of mycosis fungoides (MF) and its comparison with uninvolved skin in order to gain a better understanding of the pathogenesis of diseases. MATERIALS AND METHODS: The stratum corneum hydration, transepidermal water loss (TEWL), surface friction, pH, sebum, melanin, erythema, temperature, elasticity parameters (R0, R2, R5), thickness, and echo density of epidermis and dermis were measured on lesions of 21 patients and compared with controls (average measures of uninvolved perilesional and symmetrical skins) by paired sample t test. RESULTS: Stratum corneum hydration (P < 0.001) and echo density of dermis (P = 0.044) were significantly lower, whereas pH (P-value = 0.007), erythema (P < 0.001), and melanin content (P = 0.007) were significantly higher in lesions. There was not any significant difference in TEWL, friction index, sebum, temperature, R0, R2, R5, thickness of epidermis and dermis, and echo density of epidermis between lesions and normal skin. CONCLUSION: Parapsoriasis/MF lesions are specified by a set of certain changes in biophysical properties which are mainly correlated with histological changes. These sets of alterations may help in noninvasive, early diagnosis of parapsoriasis/MF.


Assuntos
Micose Fungoide , Neoplasias Cutâneas , Epiderme , Humanos , Micose Fungoide/diagnóstico por imagem , Sebo , Pele/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem
5.
Dermatol Ther ; 33(6): e14536, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33184957

RESUMO

Little research on impact of air pollution on human skin is available. We aimed to clarify the association between acute exposure to criteria air pollutant with biophysical characteristics of the skin. We followed a panel of 20 volunteers free of any skin diseases in skin evaluation study in Tehran, Iran from April 2017 to April 2018. Two distinct body parts including middle forehead and inside the right upper arm were evaluated at six time periods. The associations of the weighted averages of personal exposure to air pollutants at 24 hours up to 6 days, and multiday average before the skin assessment with biophysical characteristics of normal skin including sebum content, hydration, transepidermal water loss (TEWL), erythema index, melanin index, pH, temperature, friction, and elasticity were assessed in a random intercept linear mixed effects modeling approach. We observed significant positive association for the arm sebum content with exposure to PM2.5 , and SO2 ; the arm and forehead TEWL with NO2 , the arm and forehead friction with O3 , and forehead hydration with PM2.5 and PM10 in early lags. We found significant negative association for the arm melanin index, elasticity, and erythema index with exposure to O3 ; and forehead elasticity with PM2.5 and PM10 . Our results provided some evidence that short-term exposure to particulate and gaseous air pollutants have detrimental effects on biophysical and biomechanical properties of skin. The association varied across body area and depended on pollutant type.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Exposição Ambiental , Adulto , Poluição do Ar/efeitos adversos , Humanos , Irã (Geográfico) , Modelos Lineares , Pele
6.
Med J Islam Repub Iran ; 32: 108, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30815403

RESUMO

Background: Skin biometrology is a useful method for evaluation of inflammatory skin disorders such as dermatitis, psoriasis, and lichen planus. The current study tries to compare the biophysical features of skin in dermatitis, psoriasis, and lichen planus. Methods: By a convenient sampling method, 22 mild to moderate chronic dermatitis, 26 psoriasis, and 21 lichen planus patients were recruited in the study. Stratum corneum (S.C.) hydration, Transepidermal water loss (TEWL), pH, erythema, melanin, sebum, friction, elasticity parameters (R0, R2, and R5), skin temperature, skin thickness, and echo-density of epidermis and dermis were measured on the lesional (selected active lesion), uninvolved perilesional, and uninvolved symmetrical skin. The average of perilesional and symmetrical uninvolved parameters was used as control, while the percentage change of each parameter [(lesion - control / control) ×100] was calculated, and compared among three diseases by ANOVA test using SPSS software version 18. The significance level was set at α=0.05. Results: Comparison of percentage changes showed that the changes in TEWL, friction index, sebum content, R2 (gross elasticity), R5 (net elasticity), skin temperature, dermal thickness, and epidermal density are not significantly different among three skin diseases. But there were significant differences in three diseases considering the decrease in S.C. hydration (p<0.001), R0 (opposed to firmness) (p<0.001), and dermal density (p<0.001) compared to control skin. Moreover, the increase in skin pH (p<0.001), melanin content (p=0.048), erythema (p=0.023), and epidermal thickness (p <0.001) significantly differed among these diseases. Conclusion: Dermatitis, psoriasis and lichen planus lesions had specific biophysical changes. It may be helpful in their differential diagnosis.

7.
Indian J Dermatol ; 69(4): 296-300, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39296707

RESUMO

Background: Rapid diagnosis of melanoma is necessary for a good prognosis. Using teledermatology and artificial intelligence for this issue is developing, but its diagnostic accuracy is less measured in a clinical setting. Objective: The purpose of this study was to assess the diagnostic accuracy of the teledermoscopy method using the FotoFinder device as well as the Moleanalyzer Pro artificial intelligence (AI) Assistant and to compare them with the face-to-face clinical examination for the diagnosis of melanoma confirmed with histopathology. Methods: Thirty melanocytic moles of 29 patients were included in the study. Each mole was assessed face-to-face, using FotoFinder teledermoscopy and Moleanalyzer Pro software methods. The results obtained from each method were compared with the results of the gold standard (pathology). The sensitivity and specificity of the three methods were calculated for malignant and borderline versus benign lesions. Inter-method reliability between a gold standard and other methods was evaluated using per cent agreement and Cohen's kappa coefficient. Results: Five moles had a histopathological diagnosis of melanoma, and six and 19 moles were diagnosed as borderline and benign, respectively. Sensitivities and specificities were, respectively, as follows: face-to-face (90.9%, 57.9%), FotoFinder teledermoscopy (63.6%, 78.9%), FotoFinder® Moleanalyzer Pro (36.4%, 42.1%). Agreement with biopsy-obtained diagnosis categories of benign, borderline and malignant for face-to-face was 63.33%, FotoFinder teledermoscopy 73.33%, and FotoFinder® Moleanalyzer Pro 40%. Conclusions: Teledermoscopy had the highest agreement with reference diagnosis as well as the highest specificities that caused a reduction of biopsy referrals. The FotoFinder® Moleanalyzer Pro had the lowest agreement. Therefore, it cannot replace dermatologist decision making.

8.
Prim Care Respir J ; 22(1): 86-91, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23443228

RESUMO

BACKGROUND: Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. AIMS: To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial company. METHODS: This study was performed in an oil refinery in Iran in 2011. Data on 1,004 male personnel were evaluated before and after a training course conducted according to the National Institute for Occupational Safety and Health guidelines. American Thoracic Society/European Respiratory Society guidelines were used for assessment of the acceptability and repeatability criteria. RESULTS: The most common error in the first year of evaluation was forced vital capacity >6 seconds or a 1 second plateau. Acceptability and proper interpretation significantly improved after the course (p<0.05), but repeatability did not change significantly (p>0.05). CONCLUSIONS: The results of this study show that the validity and quality of spirometric tests conducted in the studied company in Iran were unacceptable, but these improved significantly after the training intervention. The study demonstrated the lack of a systematic guideline for conducting spirometry and interpreting the results in the occupational setting in Iran, and emphasises the need for a nationwide programme to improve the quality of spirometry tests in this setting.


Assuntos
Indústrias Extrativas e de Processamento , Saúde Ocupacional/educação , Melhoria de Qualidade , Testes de Função Respiratória/normas , Espirometria/normas , Adulto , Feminino , Humanos , Irã (Geográfico) , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
9.
J Cosmet Dermatol ; 22(8): 2252-2258, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36912494

RESUMO

BACKGROUND: Topical skin care products often do not reach the deeper layers of the skin, and oral hydrolyzed collagen is one of the newest and most popular systemic supplementations for skin rejuvenation. However, there are limited information in case of Middle Eastern consumers OBJECTIVE: The purpose of this study was to evaluate the tolerability and efficacy of an oral collagen supplement for improvement of skin elasticity, hydration, and roughness in Middle Eastern consumers. METHODS AND MATERIALS: It was a 12-week, before-after clinical study, conducted on 20 participants (18 women and 2 men) aged 44.15 ± 5.36 years with skin type III-IV. Skin elasticity parameters (R0, R2, R5, and R7), skin hydration and friction, as well as the thickness and echo density of the dermis, were measured after six and 12 weeks daily intake of the study product, as well as 4 weeks after stopping its use (week 16). Participants' satisfaction was assessed on the basis of their answers to the standard questionnaire, and tolerability of the product was assessed by monitoring the adverse effects. RESULTS: A significant improvement was detected in R2, R5, and skin friction at week 12 (p-values 0.041, 0.012 and <0.01, respectively). At week 16, the values remained at an increased level, which indicates the persistence of the results. The increase of dermis density in week 16 was also significant (p-value = 0.03). Moderate overall satisfaction was reported with the treatment, and a few gastrointestinal complications were reported. CONCLUSION: The study demonstrated that oral collagen peptides could significantly improve the skin elasticity, roughness, and dermis echo density, and they also proved to be safe and well-tolerated.


Assuntos
Colágeno , Pele , Humanos , Masculino , Feminino , Colágeno/administração & dosagem , Colágeno/efeitos adversos , Administração Oral , Suplementos Nutricionais/efeitos adversos , Pele/efeitos dos fármacos , Adulto , Pessoa de Meia-Idade , População do Oriente Médio , Envelhecimento da Pele , Derme/efeitos dos fármacos , Irã (Geográfico) , Satisfação Pessoal
10.
Int J Womens Dermatol ; 7(3): 331-334, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34222592

RESUMO

BACKGROUND: Pityriasis rosea (PR) is a common, self-limited, inflammatory papulosquamous skin disease with a possible viral etiology. OBJECTIVE: The goal of this study was to evaluate skin biophysical properties in patients with PR compared with uninvolved skin to better understand the pathogenesis of PR. METHODS: Stratum corneum hydration, transepidermal water loss, surface friction, pH, sebum, melanin, erythema, temperature, elasticity parameters (R0, R2, R5), thickness, and echodensity of the epidermis and dermis were measured on lesions of classic PR in 21 patients and compared with control sites (average of uninvolved perilesional and symmetrical skin) with a paired t test. RESULTS: Stratum corneum hydration (p < .001), R0 (p = .003), R2 (p = .001), R5 (p = .003), and echodensity of the dermis (p = .006) were significantly lower, whereas transepidermal water loss (p = .001), pH (p < .001), and erythema (p < .001) were significantly higher in PR lesions. There was no significant difference in friction index, sebum, melanin content, temperature, thickness of the epidermis and dermis, and echodensity of the epidermis between PR and normal skin. CONCLUSION: PR skin is characterized by certain alterations in biophysical properties, which are mostly correlated with histologic changes. These changes may be helpful in early, noninvasive diagnosis of PR.

11.
Tanaffos ; 20(3): 277-283, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35382090

RESUMO

Background: Respiratory illnesses caused by occupational exposure have the most negative effects on the workers' health status in workplaces. In occupations with a high likelihood of labor-induced pulmonary diseases, a periodic spirometry test is usually used to monitor occupational lung function and prevent occupational respiratory diseases. Monitoring workers exposed to occupational pulmonary diseases is widely done using forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) for early diagnosis of obstructive pulmonary and lung diseases. We assessed the usefulness of longitudinal data of periodic spirometry tests in a sulfate production industry. Materials and Methods: In this longitudinal study, 212 individuals working in a sulfate production industry near Tehran were examined. Demographic data and information, such as FEV1, FVC, FEV1%, FVC%, and FEV1 / FVC ratio were obtained from 2009 to 2013. Data were analyzed using the SPSS software version 21. The one-way analysis of variance (ANOVA) and repeated measures ANOVA for data analysis. Results: The results showed that the variation of the spirometry parameters over 5 years was significant. The factors studied not only decreased in some years but also increased in comparison with the previous year. Also, the average FEV1 and FVC and also FEV1 / FVC significantly was different at different time points [F(2.864, 590.029)= 27.269, P < .0001], [F(2.910, 599.546)= 38.239, P < .0001], and [F(3.257, 671.019)= 13.351, P < .0001]. Conclusion: The best spirometry tests, not only acceptable tests, are important in longitudinal spirometry evaluations. There is no systematic supervision on spirometry tests in Iran and the results of this study reflect a serious need for such supervision.

12.
Artigo em Inglês | MEDLINE | ID: mdl-33037158

RESUMO

BACKGROUND: The biophysical and ultrasonographic properties of the skin change in papulosquamous diseases. AIMS: : To identify biophysical and ultrasonographic properties for the differentiation of five main groups of papulosquamous skin diseases. METHODS: Fifteen biophysical and ultrasonographic parameters were measured by multiprobe adapter system and high-frequency ultrasonography in active lesions and normal control skin in patients with chronic eczema, psoriasis, lichen planus, pityriasis rosea and parapsoriasis/mycosis fungoides. Using histological diagnosis as a gold standard, a decision tree analysis was performed based on the mean percentage changes of these parameters [(lesion-control/control) ×100] for differentiation of the diseases. RESULTS: The accuracy of the decision tree model for differentiation of five diseases was 67% which developed based on changes in stratum corneum hydration, epidermal thickness, skin pH, melanin index, R0 (reciprocal of firmness) and erythema. Among the flowcharts for pairs of diseases, three models for differentiation had high accuracy (> 95%): those of psoriasis from lichen planus, pityriasis rosea, and parapsoriasis/mycosis fungoides. LIMITATIONS: Validation studies on a larger sample size in situations where the diagnosis is unclear are needed to confirm the accuracy and applicability of decision trees. CONCLUSION: Skin biophysical and ultrasonographic properties may help in the differentiation of papulosquamous diseases as simple and non-invasive tools.


Assuntos
Árvores de Decisões , Dermatopatias Papuloescamosas/diagnóstico por imagem , Dermatopatias Papuloescamosas/patologia , Adulto , Biometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Dermatopatias Papuloescamosas/fisiopatologia , Fenômenos Fisiológicos da Pele , Ultrassonografia , Adulto Jovem
13.
Tanaffos ; 18(2): 163-168, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32440305

RESUMO

BACKGROUND: Tobacco smoke is toxic for cells and could be a damaging factor to skin. The purpose of this study was to compare the biophysical properties of skin in smokers and non-smokers. MATERIALS AND METHODS: The study population consisted of 28 current smokers and 24 non-smokers. The hydration of the stratum corneum, trans epidermal water loss, pH, erythema, melanin content, sebum, friction and elasticity parameters (R0, R2, R5) of skin, epidermis and dermis thickness and echo-density were measured on middle forehead, right cheek and right inner arm of participants. Also volume, surface area and depth of right nasolabial folds were measured. The mean of these values in smokers were compared with non-smokers by independent sample T- test. RESULTS: Gross elasticity was significantly lower in smokers on forehead (p= 0.048). Thickness of epidermis was higher in smokers in all measured sites but the differences were not statistically significant. Thickness of dermis was higher in smokers in all measured sites too, but only the difference on cheek was statistically significant (p= 0.009). Density of epidermis was lower in smokers in all measured sites, but only the difference on forehead was statistically significant (p= 0.019). Density of dermis was lower in smokers in all measured sites, but only the difference on arm was statistically significant (p= 0.028). Volume and area of nasolabial folds were higher in smokers, but only the difference of area was statistically significant (p = 0.031). CONCLUSION: Tobacco smoking could affect the biophysical parameters of skin, especially thickness and density of dermis and epidermis and nasolabial folds.

14.
Indian J Dermatol ; 64(2): 90-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30983602

RESUMO

BACKGROUND: Nowadays noninvasive techniques are performed to evaluate the biophysical properties of skin in vivo. AIMS: The aim of this study was to evaluate the biophysical and ultrasonographic properties of skin in chronic contact or atopic dermatitis to provide better insight into pathogenesis, diagnosis, and treatment response. MATERIALS AND METHODS: The stratum corneum hydration, transepidermal water loss (TEWL), pH, erythema, melanin, sebum, friction, temperature, elasticity parameters (R0, R2, and R5), the thickness and echo-density of epidermis, dermis, and subepidermal low-echogenic band (SLEB) were measured on lesional, perilesional, and symmetrical skin of 22 chronic dermatitis patients. The average of perilesional and symmetrical skin values (control) was compared with lesional values. RESULTS: Stratum corneum hydration (P<0.001), friction (P=0.02), sebum (P=0.01), and R0 (P<0.001) were significantly lower in lesion, TEWL (P=0.03), pH (P=0.001), erythema (P=0.004), and temperature (P=0.04) were significantly higher in lesion. The thickness of epidermis (P=0.002), dermis (P=0.034), and SLEB (P<0.001) were significantly higher in lesion; and the echo-density of dermis (P<0.001) and SLEB (P<0.001) was significantly lower in lesion. CONCLUSION: Chronic contact and atopic dermatitis are characterized by certain changes in biophysical and biomechanical properties of the skin. The evaluation of these parameters might be useful in the early diagnosis and assessment of treatment response.

15.
Int J Womens Dermatol ; 5(2): 100-104, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30997382

RESUMO

BACKGROUND: Lichen planus (LP) is a chronic inflammatory disease of the skin. Currently, noninvasive techniques are used to evaluate biophysical properties of the skin in vivo. OBJECTIVE: In this study, we aimed to evaluate skin biophysical properties in patients with LP and make a comparison between involved and uninvolved skin to provide a better understanding of the pathogenesis of LP. METHODS: The stratum corneum hydration, transepidermal water loss, pH, erythema, melanin, sebum, friction, temperature, elasticity parameters (R0, R2, R5), and thickness and echo-density of the epidermis, dermis, and subepidermal low echogenic band were measured on lesions of classic LP in 21 patients and compared with the average of perilesional and symmetrical uninvolved skin (as control) with a paired t test. RESULTS: Stratum corneum hydration (p = .002), sebum (p = .04), R0 (p = .005), and echo-density of the dermis (p = .005) were significantly lower, but pH (p = .007), melanin content (p < .001), erythema (p < .001), temperature (p = .01), thickness of dermis (p = .02), and subepidermal low echogenic band (p < .001) were significantly higher in LP lesions. CONCLUSION: An evaluation of its biophysical, biomechanical, and ultrasonographic characteristics showed that the skin is an objective, noninvasive, and quantitative measuring tool that can be used to provide valuable information about skin changes in classic LP.

16.
J Clin Aesthet Dermatol ; 11(11): 40-44, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30588273

RESUMO

Background: Contact dermatitis is a common skin condition observed by dermatologists, presenting a burden on healthcare systems. Recently, there has been a trend in producing skin-identical topical preparations for the repair of skin. However, there is a limited number of experimental studies to assess the safety and efficacy of this products. Objective: This study assessed the clinical efficacy and safety of a skin-identical ceramide complex cream (Dermalex Repair Contact Eczema; Omega Pharma, Nazareth, Belgium) in the treatment of contact dermatitis. Design: This was a Phase II, before-after trial. Setting: This study was conducted at the Center for Research and Training in Skin Diseases and Leprosy (CRTSDL) at Tehran University of Medical Sciences in Tehran, Iran. Participants: Fifteen patients with contact dermatitis (8 men and 7 women) between the ages of 25 and 62 years (median age: 36.4 years) were enrolled in this study. Measurements: Changes were assessed using six skin biophysical parameters (transepidermal water loss [TEWL], stratum corneum [SC] hydration, melanin index, erythema index, skin pH, and skin friction), Physician Global Assessment (PGA) score, and Three-Item Severity (TIS) score at baseline, Week 2, and Week 4 of the study. Results: Skin hydration and TIS showed a statistically significant improvement after treatment with study cream (p=0.023 and p=0.007, respectively). Although the reduction in TEWL was not significant, a slight decrease was observed at Week 4. Conclusions: The skin-identical ceramide complex cream improved contact dermatitis with a decrease in TIS and an increase in skin hydration, implying a repair of the skin barrier.

17.
Artigo em Inglês | MEDLINE | ID: mdl-29379309

RESUMO

BACKGROUND: Application of topical moisturizers is an essential part of the management of atopic dermatitis (AD). Linoleic acid (LA), the most abundant fatty acid in the epidermis, and its derivatives have an essential role in the structure and function of the epidermal barrier, and their defects are prominent in AD. The aim of this study was to compare the efficacy and safety of two cosmetic products containing either LA or urea in patients with AD. PATIENTS AND METHODS: A total of 20 patients with AD who met the eligibility criteria and provided written informed consents were enrolled in this randomized, intra-individual split-body, single-center trial. Symmetrical lesions of patients were randomized for treatment with LA- or urea-containing water-in-oil (w/o) emulsions applied two to three times daily for 4 weeks. The efficacy of the two products was evaluated by local Scoring Atopic Dermatitis (SCORAD) of both lesions and also patient (or guardian) satisfaction. In addition, trans-epidermal water loss (TEWL), stratum corneum (SC) hydration, pH, sebum, temperature, erythema, melanin content, and ultrasonographic thickness and echo density of epidermis and dermis were measured before, and 2 and 4 weeks after, treatment. RESULTS: Four weeks of treatment with the LA-containing product resulted in a significant decrease in local SCORAD, TEWL, erythema, and echo density of dermis, as well as an increase in SC hydration compared to baseline. The urea-containing product also reduced the local SCO-RAD and echo density of dermis and increased SC hydration. In contrast to the LA-containing product, changes in TEWL and erythema were not significant. Moreover, the reduction of erythema was significantly higher in the LA-containing product-treated side compared to the urea-containing product-treated side (p = 0.006). CONCLUSION: Both LA- or urea-containing w/o emulsions can significantly improve barrier dysfunction and clinical severity of AD. In agreement with literature, it was confirmed that an LA-containing w/o emulsion exhibited erythema-reducing effects. Since emollients should be used on a regular basis, patients should choose a product by individual preference following recommendation by their dermatologists.

18.
J Cutan Aesthet Surg ; 10(2): 101-105, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28852297

RESUMO

BACKGROUND AND AIM: Lips have a significant role in face aesthetic perception, and lip augmentation is one of the most commonly requested aesthetic procedures. Non-permanent dermal fillers, such as hyaluronic acid (HA), are used for augmenting the lips. This article presents the results of Phase II, before - after designed study, assessing the safety and efficacy of a soft tissue HA filler, for upper lip augmentation. MATERIALS AND METHODS: Investigators treated 10 healthy adult women 28-45 years old, using a single injection of Hyamax Kiss soft tissue HA filler (a product from Hyamed Laboratories, Switzerland) for upper lip augmentation. The primary efficacy endpoint was an increase in lip fullness at least one grade on Medicis Lip Fullness Scale at 2, 12 and 24 weeks post-treatment. Furthermore, the effectiveness and durability of filler were assessed using a 5-point Investigator's Global Assessment (IGA). Adverse events and volunteers' satisfaction were reported using visual analog scale. RESULTS: Response to treatment (as defined above) after 2, 12 and 24 weeks were observed in 80%, 70% and 80% of patients, respectively. No statistical difference was found in response to treatment rate between follow-up visits (P = 0.83). The mean value of IGA score in weeks 2, 12 and 24 were 3.4 ± 0.96, 3.3 ± 0.67 and 3.3 ± 0.67, respectively. The study subjects were almost all satisfied with their lip improvement. Reported adverse effects were temporary and mostly mild in severity. CONCLUSION: Soft tissue HA filler tested in this study was well tolerated, efficient and durable when used for upper lip augmentation.

19.
Work ; 55(4): 765-772, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28059825

RESUMO

BACKGROUND: Untreated Obstructive sleep apnea syndrome (OSAS) as a common breathing sleep disorder results in impaired work performance. The economic burden of untreated OSAS accounts for billions of dollars per year. OBJECTIVE: The aim of this study was to evaluate the prevalence of snoring and the risk of OSAS in healthcare system staff. METHODS: This cross-sectional study was performed on 715 staff of Dr. Masih Daneshvari Hospital in 2012. The Berlin questionnaire was used to identify the prevalence of snoring and the risk of sleep apnea. Additional information, including demographic characteristics, night work, night sleep less than 4 hours, smoking, underlying disease, and quality of sleep were evaluated as well. The information was analyzed using SPSS 15. RESULTS: 12.6% reported snoring. 6.9% and 93.1% were categorized into the high and low risk groups for OSAS respectively. There was an association between the risk of OSAS and age group (P-value = 0.007), gender (P-value = 0.028), marital status (P-value = 0.008), educational level (P-value = 0.035), chronic disease (P-value = 0.008), night sleep less than 4 hours (P-value = 0.001), difficulty in staying asleep (P-value = 0.000) and waking up too early (P-value = 0.006). Even logistic regression analysis demonstrated the relationship between the risk of OSAS and night sleep less than 4 hours (P-value = 0.019) and difficulty in staying asleep (P-value = 0.009). CONCLUSIONS: The results showed that the risk of OSAS is significant in healthcare system staff. Hope to provide a special screening program for OSAS in a regular occupational examination.


Assuntos
Recursos Humanos em Hospital , Prevalência , Síndromes da Apneia do Sono/epidemiologia , Ronco/epidemiologia , Adulto , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Irã (Geográfico)/epidemiologia , Modelos Logísticos , Masculino , Fatores de Risco , Inquéritos e Questionários
20.
Acta Med Iran ; 54(3): 211-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27107527

RESUMO

Recognizing patients at a higher risk of developing chronic low back pain (LBP) is important in industrial medicine. This study aimed to assess the power and quality of General Health Questionnaire (GHQ) for prediction of the odds of chronicity of acute LBP. This study was conducted on industrial workers. All subjects with acute LBP who met the inclusion criteria were enrolled. Demographic characteristics, occupational, physical, and mental parameters and the general health status of subjects were evaluated;  they were followed up for developing chronic LBP for one year. Cigarette smoking, high body mass index, job stress, physical load and high GHQ scores were found to be the risk factors for the progression of acute LBP to chronic LBP (P<0.05). Standing position while working, age, work experience, exercise, level of education, weekly work hours and shift work were not the risk factors for chronic LBP (P>0.05). High GHQ score can be a risk factor for progression of acute LBP to chronic LBP. The GHQ in combination with the Job Content Questionnaire can be used as a quick and simple screening tool for detection of subjects at high risk of chronic LBP when evaluating acute LBP in an occupational setting.


Assuntos
Nível de Saúde , Dor Lombar/etiologia , Doenças Profissionais/etiologia , Adulto , Progressão da Doença , Feminino , Humanos , Dor Lombar/diagnóstico , Masculino , Fatores de Risco , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA