Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Idioma
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(2): 476-80, 2012 Feb.
Artigo em Zh | MEDLINE | ID: mdl-22512193

RESUMO

As a key role in the acid-deposition and the generation of secondary particle matter (PM), measurement of the concentration of atmospheric ammonia in urban area has been attracting the scientists' interests nowadays. After studying the special absorption features of ammonia in short UV wavelength range, detailed concernful issues were put forward in the present paper. The decision of using xenon lamp as the light source was made after the evaluation of measurement of light spectroscopy. Retrieval wavelength band for NH3 was fixed from 204 to 214 nm and optimal method of deducting other interferential gases was also shown. A home-made open-path DOAS (OP-DOAS) system was set up for the measurement of the concentration of atmospheric NH3. The detection limit of such system was calculated with the typical noise level as low as 0.33 microg x m(-3) with the optical path 228 m. Through field experiment in Guangzhou city, such a system can be competent for the online and high time-resolution monitoring of the concentration of atmospheric ammonia. With a significant diurnal variation, the atmospheric ammonia changed from 0.83 to 3.11 microg x m(-3) with the mean value 1.59 microg x m(-3). The representative character of the diurnal variation is that the concentration of NH3 peaks during night while drops to bottom in the daytime. After the error analysis procedure, typical measurement accuracy of such OP-DOAS system was within 10%.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(11): 2886-90, 2012 Nov.
Artigo em Zh | MEDLINE | ID: mdl-23387143

RESUMO

Influences of LEDs (without etalon structure and center wavelengths are respectively 370 nm (near-UV), 452 nm (blue) and 660 nm(red)) temperature shifts on differential optical absorption spectroscopy(DOAS) for measuring NO2 were studied. NO2 absorption spectra were formed using LED emitting spectra at 10 degrees C. The measured LED spectra at other temperatures were used as reference spectra of DOAS. Thus, NO2 differential optical densities under different LED temperature shifts were acquired and then NO2 differential cross-sections were fitted to the acquired differential optical densities. From fitting results, the linear relations of 0.995, 0.945 and 0.989 correlation between delta of fitting residual and near-UV, blue and red LEDs temperature shifts were found and their slopes are respectively 1.12 x 10(-3), 5.25 x 10(-5) and 7.45 x 10(-4) degrees C(-1). The fitting results show that the influence of temperature shifts of blue LED on DOAS retrieval is negligible and the temperature shifts of near-UV and red LED are impressible to DOAS measurement resulting in degradation of detection sensitivity. The retrieval results of blue LED with and without etalon with similar temperature properties were compared and showed that etalon of LED will greatly increase the influence of temperature shifts of LED on DOAS retrieval.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(7): 1734-8, 2012 Jul.
Artigo em Zh | MEDLINE | ID: mdl-23016314

RESUMO

In this paper, based on Differential Optical Absorption Spectroscopy (DOAS) technique, experimental measurements of chlorine was carried out in the laboratory with a small self-built experimental system. In dealing with the standard cross-section of chlorine, we presented two different methods: triangle filtering and polynomial fitting. Experiments showed that the concentration of chlorine could be accurately retrieved by the latter one. Simulation results showed that the error of retrieval result by fifth-order polynomial fitting was smaller than by other orders and an actual retrieval example shows that the fitting spectrums were nearly coincident with the measured spectrums with a residual delta(peak to peak) below 5 per hundred; The results measured in different sample pools displayed a high linearity of 0.9961 by this method. The main sources of errors during the entire experiment were simply analyzed. According to the experimental result above, it is feasible to detect chlorine using DOAS technology by polynomial fitting.

4.
Huan Jing Ke Xue ; 33(11): 3718-24, 2012 Nov.
Artigo em Zh | MEDLINE | ID: mdl-23323398

RESUMO

In order to study the levels of BTX (benzene, toluene, xylene, etc) nearby the main roads of Guangzhou from November 2010 to December 2010 during the Asian Games, BTX and conventional pollutants such as NO2, O3 in the air were monitored by the DOAS system nearby Huangsha Road, which is in the Liwan District of Guangzhou City. The results showed that, during the entire period, BTX showed a high concentration in the evening and the average concentrations of benzene, toluene, p-xylene, m-xylene and phenol were 15.9 microg x m(-3), 61.3 microg x m(-3), 6.5 microg x m(-3), 16.9 microg x m(-3), 0.88 microg x m(-3), respectively. The average concentrations of benzene and toluene were close to those in other cities, and the ratio of toluene to benzene was in range of 1.2-6.16. Throughout the monitoring period, the correlation coefficient of benzene and toluene was 0.86 and it rose to 0.985 during the high concentration period, indicating that they had the same source in this region. The correlation coefficient between toluene and CO was 0.78, indicating that traffic emissions was the major source of benzene and toluene. Based on the combination of wind speed, wind direction and other meteorological data, it was found that the weather condition was an important factor which affected the BTX concentration, and some possible point sources were suggested nearby the site.


Assuntos
Poluentes Atmosféricos/análise , Benzeno/análise , Tolueno/análise , Emissões de Veículos/análise , Xilenos/análise , China , Cidades , Monitoramento Ambiental
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA