Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Curr Cardiol Rep ; 24(1): 33-41, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35099762

RESUMO

PURPOSE OF REVIEW: Bicuspid aortic valve (BAV) disease is the most common congenital heart defect worldwide. When severe, symptomatic aortic stenosis ensues, the treatment has increasingly become transcatheter aortic valve replacement (TAVR). The purpose of this review is to identify BAV classification and imaging methods, outline TAVR outcomes in BAV anatomy, and discuss how computational modeling can enhance TAVR treatment in BAV patients. RECENT FINDINGS: TAVR use in BAV patients, when compared to use in tricuspid aortic valves, showed lower device success rate, and there remains no long-term randomized trial data. It has been reported that BAV patients with severe calcification increase the rate of complications. Additionally, the asymmetrical morphology of BAVs often results in asymmetric stent geometries which have implications for increased thrombosis risk and decreased durability. These adverse outcomes are currently very difficult to predict from routine pre-procedural imaging alone. Recently developed patient specific experimental and computational techniques have the potential to assist in filling knowledge gaps in the mechanisms of these complications and provide more information during preclinical planning for better TAVR selection in low surgical risk BAV patients. Efficacy of TAVR for irregular BAV anatomies remains concerning due to the lack of a long-term randomized trial data, their increased rate of short-term complications, and signs that long-term durability could be an issue. More knowledge on identifying which BAV anatomies are at greater risk for these adverse outcomes can potentially improve patient selection for TAVR versus SAVR in low surgical risk BAV patients.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Constrição Patológica , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Humanos , Estenose da Valva Mitral/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Ann Biomed Eng ; 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734846

RESUMO

Patients with bicuspid aortic valve (BAV) commonly have associated aortic stenosis and aortopathy. The geometry of the aortic arch and BAV is not well defined quantitatively, which makes clinical classifications subjective or reliant on limited 2D measurements. The goal of this study was to characterize the 3D geometry of the aortic arch and BAV using objective and quantitative techniques. Pre-TAVR computed tomography angiogram (CTA) in patients with BAV and aortic stenosis (AS) were analyzed (n = 59) by assessing valve commissural angle, presence of a fused region, percent of fusion, and calcium volume. The ascending aorta and aortic arch were reconstructed from patient-specific imaging segmentation to generate a centerline and calculate maximum curvature and maximum area change for the ascending aorta and the descending aorta. Aortic valve commissural angle signified a bimodal distribution suggesting tricuspid-like (≤ 150°, 52.5% of patients) and bicuspid-like (> 150°, 47.5%) morphologies. Tricuspid like was further classified by partial (10.2%) or full (42.4%) fusion, and bicuspid like was further classified into valves with fused region (27.1%) or no fused region (20.3%). Qualitatively, the aortic arch was found to have complex patient-specific variations in its 3D shape with some showing extreme diameter changes and kinks. Quantitatively, subgroups were established using maximum curvature threshold of 0.04 and maximum area change of 30% independently for the ascending and descending aorta. These findings provide insight into the geometric structure of the aortic valve and aortic arch in patients presenting with BAV and AS where 3D characterization allows for quantitative classification of these complex anatomic structures.

3.
Ann Biomed Eng ; 51(10): 2172-2181, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37219698

RESUMO

Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve disease (BAV) has potential risks of under expansion and non-circularity which may compromise long-term durability. This study aims to investigate calcium fracture and balloon over expansion in balloon-expandable TAVs on the stent deformation with the aid of simulation. BAV patients treated with the SAPIEN 3 Ultra with pre- and post-TAVR CTs were analyzed (n = 8). Simulations of the stent deployment were performed (1) with baseline simulation allowing calcium fracture, (2) without allowable calcium fracture and (3) with balloon over expansion (1 mm larger diameter). When compared to post CT, baseline simulations had minimal error in expansion (2.5% waist difference) and circularity (3.0% waist aspect ratio difference). When compared to baseline, calcium fracture had insignificant impact on the expansion (- 0.5% average waist difference) and circularity (- 1.6% average waist aspect ratio difference). Over expansion had significantly larger expansion compared to baseline (15.4% average waist difference) but had insignificant impact on the circularity (- 0.5% waist aspect ratio difference). We conclude that stent deformation can be predicted with minimal error, calcium fracture has small differences on the final stent deformation except in extreme calcified cases, and balloon over expansion expands the waist closer to nominal values.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Cálcio , Resultado do Tratamento , Desenho de Prótese
4.
Ann Cardiothorac Surg ; 11(4): 389-401, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35958538

RESUMO

Bicuspid aortic valve (BAV) disease is the most common form of congenital heart valve defect. It is associated with aortic stenosis (AS), aortic insufficiency, and aortopathy. Treatment of severe AS requires valve replacement which historically has been performed with surgical aortic valve replacement (SAVR). Recently, transcatheter aortic valve replacement (TAVR) has emerged as a promising alternative. However, increased rates of adverse outcomes following TAVR have been shown in BAV patients with high amounts of calcification. Comparison between TAVR and SAVR in low surgical risk BAV patients in a randomized trial has not been performed and TAVR for BAV long-term performance is unknown due to lack of clinical data. Due to the complexity of BAV anatomies and the significant knowledge gap from the lack of clinical data, SAVR still has many benefits over TAVR in low surgical risk BAV patients. It also remains common for BAV patients to have an aortopathy, which currently can be treated with surgical techniques. This review aims to outline BAV associated diseases and their treatment strategies, the main TAVR adverse outcomes associated with anatomically complex BAV patients, TAVR strategies for mitigating these risks and the current state of cutting-edge 3D printing and computer modeling screening methods that can provide otherwise unobtainable preoperative information during the BAV patient selection process for TAVR.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA