Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Heart Vessels ; 39(6): 496-504, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38411631

RESUMO

Limited data exist regarding drug-coated balloon (DCB) treatment in de novo large coronary arteries. We sought to demonstrate procedural characteristics, residual stenosis, and clinical outcomes following DCB angioplasty for de novo lesions in large versus small coronary arteries. The study included 184 consecutive patients with 223 de novo coronary lesions undergoing paclitaxel DCB angioplasty between January 2019 and August 2020, who were divided according to whether the DCB diameter was ≥ 3.0 mm (large group, n = 58) or < 3.0 mm (small group, n = 125). The large group had a higher proportion of acute coronary syndrome more commonly with ostial, bifurcation, and calcified lesions in large vessels and received lesion preparation with more frequent use of scoring or cutting balloons and atherectomy devices compared to the small group. Postprocedural angiographic diameter stenosis was smaller in the large group compared to the small group (31% [22-37] vs. 35% [26-42], p = 0.032), and intravascular ultrasound revealed no significant difference in postprocedural area stenosis between the groups (66.2 ± 7.7% vs. 67.9 ± 7.8%; p = 0.26). The median follow-up duration was 995 days. The incidence of a composite of all-cause death, myocardial infarction, stroke, or target lesion revascularization was similar between the groups (log-rank p = 0.41) and was influenced by the presence of acute coronary syndrome and anemia but not by DCB diameter. The rate of cardiovascular outcomes after DCB treatment was comparable in de novo large and small coronary arteries. Notably, well-planned lesion preparation with intravascular imaging guidance was prevalent in large vessels.


Assuntos
Angioplastia Coronária com Balão , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana , Vasos Coronários , Humanos , Masculino , Feminino , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Angioplastia Coronária com Balão/instrumentação , Idoso , Vasos Coronários/diagnóstico por imagem , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico , Estudos Retrospectivos , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Seguimentos
2.
Catheter Cardiovasc Interv ; 102(6): 969-978, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855186

RESUMO

BACKGROUND: There is a paucity of data regarding the optimal duration of drug-coated balloon (DCB) inflation for coronary lesions. We sought to explore the effect of DCB angioplasty with versus without long inflation time on residual stenosis and clinical outcomes in patients with coronary artery disease. METHODS: This study included 314 consecutive patients with 445 lesions undergoing paclitaxel DCB angioplasty using different inflation time, divided according to whether the total inflation time of the DCB was ≥180 s (prolonged group) or <180 s (standard group). The primary clinical endpoint, defined as a composite of all-cause death, myocardial infarction, stroke, or target lesion revascularization, was examined in 92 propensity score matched pairs. RESULTS: In the matched cohort, the median clinical follow-up period was 947 days. Postprocedural angiographic diameter stenosis was smaller in the prolonged group than in the standard group (30.0% [22.0-37.0] vs. 33.5% [25.5-40.5]; p = 0.042). Intravascular ultrasound measurements revealed that longer DCB inflation time resulted in smaller area stenosis (66.6 ± 7.8% vs. 69.4 ± 7.0%; p = 0.044) and a less mean increase in percent atheroma volume (-11.2 ± 7.1% vs. -7.4 ± 5.9%; p = 0.004) after angioplasty. The rate of the primary endpoint was lower in the prolonged group than in the standard group (log-rank p = 0.025). The efficacy of prolonged DCB inflation was prominent in patients with in-stent restenosis and longer lesions. CONCLUSION: Prolonged DCB inflation was associated with reduced residual stenosis and improved clinical outcomes in patients with coronary artery disease undergoing percutaneous coronary intervention. Prospective randomized trials are warranted to validate the benefits of DCB angioplasty with long inflation time.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Constrição Patológica/complicações , Pontuação de Propensão , Estudos Prospectivos , Resultado do Tratamento , Angioplastia Coronária com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Reestenose Coronária/etiologia
3.
Circ J ; 82(11): 2887-2895, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30135322

RESUMO

BACKGROUND: Basal interventricular septum (IVS) hypertrophy (BSH) with reduced basal IVS contraction and IVS-aorta angle is frequently associated with aortic stenosis (AS). BSH shape suggests compression by the longitudinally elongated ascending aorta, causing basal IVS thickening and contractile dysfunction, further suggesting the possibility of aortic wall shortening to improve the BSH. Surgical aortic valve replacement (SAVR), as opposed to transcatheter AVR (TAVR), includes aortic wall shortening by incision and stitching on the wall and may potentially improve BSH. We hypothesized that BSH configuration and its contraction improves after SAVR in patients with AS. Methods and Results: In 32 patients with SAVR and 36 with TAVR for AS, regional wall thickness and systolic contraction (longitudinal strain) of 18 left ventricular (LV) segments, and IVS-aorta angle were measured on echocardiography. After SAVR, basal IVS/average LV wall thickness ratio, basal IVS strain, and IVS-aorta angle significantly improved (1.11±0.24 to 1.06±0.17; -6.2±5.7 to -9.1±5.2%; 115±22 to 123±14°, P<0.001, respectively). Contractile improvement in basal IVS was correlated with pre-SAVR BSH (basal IVS/average LV wall thickness ratio or IVS-aorta angle: r=0.47 and 0.49, P<0.01, respectively). In contrast, BSH indices did not improve after TAVR. CONCLUSIONS: In patients with AS, SAVR as opposed to TAVR improves associated BSH and its functional impairment.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Comunicação Interventricular/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Feminino , Comunicação Interventricular/complicações , Comunicação Interventricular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/instrumentação
4.
Circulation ; 126(11 Suppl 1): S214-21, 2012 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-22965986

RESUMO

BACKGROUND: In patients with mitral valve prolapse, nonprolapsed leaflets are often apically tented. We hypothesized that secondary left ventricular dilatation attributed to primary mitral regurgitation (MR) causes papillary muscle (PM) displacement, resulting in this leaflet tenting/tethering, and that secondary tethering further exacerbates malcoaptation and contributes to MR severity. METHODS AND RESULTS: Three-dimensional transesophageal echocardiography was performed in 25 patients with posterior mitral leaflet prolapse with an intact anterior mitral leaflet (AML) and 20 controls. From 3D zoom data sets, 11 equidistant antero-posterior cut planes of the mitral valve at midsystole were obtained. In each plane, tenting area of nonprolapsed leaflet and prolapse area of prolapsed leaflet were measured. Prolapse/tenting volume of each region was obtained as the product of interslice distance and the prolapse/tenting area. AML tenting volume and whole leaflet prolapse/tenting volume were then obtained. The PM tethering distance between PM tips and anterior mitral annulus was measured from 3D full-volume data sets. The severity of MR was quantified by vena contracta area extracted from color 3D transesophageal echocardiography data sets. AML tenting volume was significantly larger in patients with posterior mitral leaflet prolapse compared with that in controls (1.2 ± 0.5 versus 0.6 ± 0.2 mL/m(2); P<0.001). Multivariate regression analysis identified independent contribution to AML tenting volume from an increase in PM tethering distance. Multivariate regression analysis identified independent contributions to MR severity (vena contracta area) from both whole leaflet tenting volume (r=0.44; P<0.05) and prolapse volume (r=0.44; P<0.05). AML tenting volume decreased along with left ventricular volume and PM tethering distance postrepair (n=8; P<0.01). CONCLUSIONS: These results suggest that primary mitral valve prolapse with MR causes secondary mitral leaflet tethering with PM displacement by left ventricular dilatation, which further exacerbates valve leakage, constituting a vicious cycle that would suggest a pathophysiologic rationale for early surgical repair.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/complicações , Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Idoso , Antropometria , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/etiologia , Dilatação Patológica/fisiopatologia , Progressão da Doença , Ecocardiografia Transesofagiana , Feminino , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Movimento (Física) , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
5.
Circ J ; 76(10): 2481-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22785152

RESUMO

BACKGROUND: Different influences of left ventricular (LV) remodeling on anterior and posterior mitral leaflet (AML and PML) tethering in ischemic mitral regurgitation (MR) has not been fully investigated. We hypothesized that progressive outward displacement of papillary muscles, including posterior vector, may cause greater tethering to PML compared to AML. METHODS AND RESULTS: In 79 patients with LV ejection fraction <50% and 20 controls, LV sphericity, AML and PML tethering angles, apical and posterior displacement of coaptation, mitral annular area, and severity of MR (vena contracta width) were measured using 3-D echocardiography. To examine different influences of LV remodeling on AML and PML tethering, interaction between AML/PML and LV sphericity was tested using multiple regression analysis. Both AML and PML tethering significantly increased with increased LV sphericity (r=0.59 and 0.65, P<0.001). Multiple regression yielded a significant interaction term between AML vs. LV sphericity and PML vs. LV sphericity (t=3.69, P<0.001), indicating greater influence from LV remodeling on PML compared to that for the AML. Multivariate analysis demonstrated independent contributions to MR severity from PML tethering primarily along with posterior and apical displacement of coaptation. CONCLUSIONS: LV remodeling augments tethering of both AML and PML, with greater influence on PML.


Assuntos
Ecocardiografia Tridimensional , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Remodelação Ventricular , Idoso , Humanos , Pessoa de Meia-Idade
6.
Circ J ; 74(12): 2627-32, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20966595

RESUMO

BACKGROUND: Aging and westernization of lifestyle has accelerated the prevalence and severity of atherosclerotic cardiovascular diseases in the Japanese population. The aim of this study was to examine the prevalence of complex plaque formation in the descending thoracic aorta (DTA) as assessed by real-time 3-dimensional transesophageal echocardiography (3DTEE) and its relation to clinical factors. METHODS AND RESULTS: A prospective analysis of atherosclerotic plaque in the DTA of 350 consecutive patients who were clinically indicated for real-time 3DTEE was performed. Systematic assessment of the DTA plaques was performed using a biplane mode from the aorta at the level of the stomach to the aortic arch. When a large plaque (>4mm) was identified, detailed 3-dimensional (D) observations were performed using a 3D zoom mode. Complex plaque was defined as either mobile or an ulcer-like pouch in the DTA. Complex plaques were detected in 51 patients (15%), who were more advanced in age and had a higher prevalence of chronic kidney disease. A multivariate analysis revealed that the presence of complex plaque was an independent predictor of renal impairment. CONCLUSIONS: The prevalence of complex plaque was not low in the this Japanese study population. A close association between complex plaque and renal dysfunction raises the possibility that complex plaque in the DTA is a potential cause of renal dysfunction.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Aterosclerose/epidemiologia , Ecocardiografia Transesofagiana , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Aterosclerose/complicações , Feminino , Humanos , Japão , Nefropatias/epidemiologia , Nefropatias/etiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos
7.
Circ J ; 74(12): 2649-57, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21084759

RESUMO

BACKGROUND: Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector computed tomography (MDCT) as a reference, and (2) to examine whether aortic root geometry differs between patients with and without AS. METHODS AND RESULTS: 3DTEE and contrast-enhanced MDCT were performed in 35 patients. Multiplanar reconstruction was used to measure the left ventricular outflow tract (LVOT) and aortic annulus diameter/area, aortic valve area (AVA), and distances between the annulus and coronary artery ostium. The same 3DTEE measurements were performed in patients with (n=71) and without AS (n=80). Aortic annular and LVOT areas measured by 3DTEE were slightly but significantly smaller compared with values obtained with MDCT. Both methods revealed that the aortic annulus and LVOT have an oval shape. Aortic annular and LVOT area, AVA and the distances between the aortic annulus and the coronary ostia correlated well between the 2 modalities. Only minor differences in aortic root geometry were observed between patients with AS and those without. CONCLUSIONS: The geometry of the aortic annulus can be reliably evaluated using 3DTEE as an alternative to MDCT for the assessment of aortic root.


Assuntos
Aorta/patologia , Estenose da Valva Aórtica/patologia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aortografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Eur J Echocardiogr ; 11(4): 369-76, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20022869

RESUMO

AIMS: The aims of this study were to (i) investigate aortic annulus dynamics using two-dimensional (2D) speckle tracking echocardiography, (ii) determine optimal 2D short-axis view for the calculation of planimetric aortic valve area (AVA), and (iii) compare 2D planimetric AVA extracted from volumetric three-dimensional data sets using real-time 3DTEE (three-dimensional transoesophageal echocardiography) with standard 2DTEE planimetry. METHODS AND RESULTS: We studied 60 patients with aortic stenosis (AS) and 10 control subjects. AVA was calculated by standard 2DTEE planimetry method, volumetric 3DTEE method, and continuity equation (CE) from transthoracic echocardiography. In addition, aortic annular motion was studied using 2D speckle tracking. Aortic annulus moves cranially during early systole and subsequently moves caudally during the remainder of systole and isovolumic relaxation. Annulus again moved in the cranial direction during diastole in both groups. Although AVA correlated well between 2DTEE and 3DTEE methods (r = 0.95), 2DTEE showed a significantly larger AVA compared with 3DTEE method (1.26 +/- 0.39 vs. 1.10 +/- 0.39 cm(2), P < 0.001). In patients in whom aortic cusps were visible in 2DTEE short-axis images during systole only (n = 45), AVA using 2DTEE was still larger than that measured with 3DTEE. However, the bias in AVA was significantly lower compared with the remaining 15 patients (-0.13 +/- 0.11 vs. -0.26 +/- 0.12 cm(2), P < 0.005). Although both methods showed moderate correlation with AVA by CE (r = 0.78, 0.75), mean differences were significantly smaller by 3DTEE than 2DTEE (-0.01 +/- 0.25 vs. -0.17 +/- 0.27 cm(2), P < 0.001). CONCLUSION: Aortic annular motion affects the calculation of AVA using 2DTEE. Three-dimensional transoesophageal echocardiography has a potential for more accurate determination of anatomical AVA.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Osaka City Med J ; 54(1): 21-30, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18819262

RESUMO

BACKGROUND: Peripheral vascular disease (PVD) is associated with an increased risk of cardiovascular disease. However, few studies have evaluated the prognosis of asymptomatic PVD in patients with coronary artery disease (CAD). METHODS: The aim of the study was to determine the prevalence of asymptomatic and symptomatic PVD in patients with ST-elevated myocardial infarction (STEMI) or unstable angina pectoris (UAP) who underwent percutaneous coronary intervention (PCI), and to conduct a 3-year follow-up for cardiovascular events. Systemic atherosclerosis was evaluated, using duplex ultrasonography in 380 consecutive patients who had undergone PCI from January 2003 to December 2005. RESULTS: Twenty-four percent of the CAD patients had PVD. Patients with PVD had significantly more risk factors for atherosclerosis, including increased age, diabetes mellitus, smoking (p < 0.05), and multivessel CAD (p < 0.001). Multivariate regression analysis demonstrated that STEMI, PVD and multivessel CAD were independent predictors for major adverse cardiac events (MACE) (p < 0.05). Kaplan-Meier curves for MACE in all the patients showed that the MACE rates were significantly higher in STEMI and PVD cases compared with other cases (p < 0.05). We also classified patients with PVD into symptomatic (53%) and asymptomatic (47%) cases, and the MACE rates between these groups did not differ significantly (p < 0.82). CONCLUSIONS: There is a high prevalence of asymptomatic PVD in patients with CAD and even asymptomatic PVD is associated with increased CAD mortality.


Assuntos
Angioplastia Coronária com Balão , Isquemia Miocárdica/terapia , Avaliação de Resultados em Cuidados de Saúde , Doenças Vasculares Periféricas/terapia , Idoso , Idoso de 80 Anos ou mais , Angina Instável/diagnóstico , Angina Instável/terapia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Isquemia Miocárdica/diagnóstico , Doenças Vasculares Periféricas/diagnóstico , Prevalência , Prognóstico , Estudos Prospectivos , Análise de Regressão
11.
Am Heart J ; 154(4): 725-31, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17893000

RESUMO

BACKGROUND: The benefits of intra-aortic balloon pumping (IABP) usage reportedly occur through systolic unloading of the left ventricle and the augmentation of diastolic coronary flow. The aim of this study was to assess the change in intracoronary pressure distal to the coronary stenosis after the IABP by using an intracoronary pressure wire. METHODS: Hemodynamic variables and intracoronary pressure data were measured in 16 patients requiring IABP for clinical indication (11 vessels with coronary stenosis and 5 normal vessels were enrolled). Coronary pressure was measured directly in each vessel with and without IABP support. RESULTS: The diastolic aortic pressure during IABP increased compared with that without the IABP (97.9 +/- 11.7 vs 80.3 +/- 10.7 mm Hg, P < .01). The systolic aortic and intracoronary pressure during the IABP decreased (aortic pressure: 83.8 +/- 10.4 vs 95.9 +/- 11.3 mm Hg, P < .01, intracoronary pressure: 67.6 +/- 16.5 vs 76.2 +/- 20.4 mm Hg, P < .01). The diastolic distal coronary pressure (Pd) increased during the IABP in healthy coronary arteries (87.3 +/- 4.8 vs 72.1 +/- 10.3 mm Hg, P < .05). However, Pd in stenotic coronary arteries with the IABP did not increase statistically compared with those without the IABP (44.0 +/- 21.3 vs 42.8 +/- 17.9 mm Hg). There was a significant correlation between the change in Pd after IABP insertion and percent diameter stenosis calculated by quantitative coronary angiography (r2 = 0.51, P < .001). CONCLUSIONS: In the presence of a critical coronary stenosis, the IABP does not increase the diastolic coronary pressure distal to the stenosis. Thus, the major effect of IABP on high-risk patients with severe coronary stenosis may relate to the reduction of oxygen demand by systolic unloading more than diastolic augmentation of the coronary flow.


Assuntos
Pressão Sanguínea , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Balão Intra-Aórtico , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Doença das Coronárias/terapia , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/fisiologia , Sístole/fisiologia
12.
Am J Cardiol ; 98(3): 298-302, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16860012

RESUMO

We evaluated the influence of collateral circulation on a donor left anterior descending artery and an appropriate cut-off value of coronary flow velocity reserve for the diagnosis of significant donor left anterior descending artery stenosis. Measurement of coronary flow velocity reserve by transthoracic Doppler echocardiography provides noninvasive assessment of significant left anterior descending artery stenosis. The cut-off value of coronary flow velocity reserve for the diagnosis of significant donor left anterior descending artery stenosis has not been well studied. We retrospectively examined 64 patients who had no significant left anterior descending artery stenosis and who had other coronary artery stenosis. Seventeen patients had collaterals from the left anterior descending artery (group A) and 47 patients did not have collaterals (group B). We prospectively examined 23 consecutive patients who had collaterals from the left anterior descending artery to other coronary arteries. Eight patients had a significant donor left anterior descending artery stenosis. Coronary flow velocity reserve assessment was performed by transthoracic Doppler echocardiography in the 2 protocols. Coronary flow velocity at baseline in group A was significantly higher than that in group B. Coronary flow velocity reserve in group A was significantly lower than that in group B (2.6 +/- 0.8 vs 3.2 +/- 0.9, p < 0.05). Coronary flow velocity during hyperemia and coronary flow velocity reserve were significantly lower in patients with significant stenosis. A cut-off value of 2.0 of coronary flow velocity reserve had a sensitivity of 88% and a specificity of 93% for the diagnosis of significant donor left anterior descending artery stenosis. In conclusion, coronary flow velocity reserve of a donor left anterior descending artery was decreased by the presence of collaterals. However, a cut-off value < 2.0 was appropriate for the diagnosis of significant donor left anterior descending artery stenosis in a population that included patients with collaterals.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Colateral/fisiologia , Circulação Coronária/fisiologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Ecocardiografia Doppler/métodos , Doadores de Tecidos , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/transplante , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença
15.
J Am Coll Cardiol ; 43(3): 368-76, 2004 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-15013116

RESUMO

OBJECTIVES: The study was done to determine potential utility of measuring coronary flow velocity (CFV) by transthoracic Doppler echocardiography (TTDE) during intra-aortic balloon pumping (IABP). BACKGROUND: Use of IABP has been shown to increase CFV assessed by an invasive technique. The CFV in the left anterior descending coronary artery (LAD) can be measured by TTDE. METHODS: Coronary flow velocity in the distal LAD by TTDE was measured in 40 critically ill patients requiring IABP. All patients received emergency coronary angiography. Both CFV and pressure data were obtained during 1:2 balloon pumping. RESULTS: Adequate diastolic CFV recording was obtained in all patients. The IABP decreased systolic pressure and increased diastolic pressure. Average peak diastolic flow velocity and diastolic velocity time integral was 19 +/- 11 cm/s and 7.7 +/- 4.4 cm with non-augmented beat. These values were increased significantly (61 +/- 38%, 59 +/- 35%, p < 0.001) with augmented beat. Significant correlation was noted between % diastolic pressure augmentation and % increase in diastolic CFV (r = 0.62 to 0.69, p < 0.001). There was no significant difference in flow enhancement during IABP, irrespective to the proximal LAD stenosis severity (severe stenosis: 73 +/- 70%; intermediate stenosis: 61 +/- 29%; no significant stenosis: 58 +/- 29%; p = NS, analysis of variance). By continuous recording of CFV, the optimal timing of balloon control could be adjusted to maximize flow velocity during augmentation. CONCLUSIONS: Use of TTDE can be employed in monitoring CFV augmentation during IABP. The IABP produced significant distal flow enhancement even in patients with critical proximal stenosis. This totally noninvasive approach may help to optimize the benefits of IABP for coronary flow augmentation.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Balão Intra-Aórtico/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
16.
Am J Cardiol ; 95(11): 1363-6, 2005 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-15904645

RESUMO

Coronary flow velocity reserve was measured to assess the frequency of coronary steal in the collateral-dependent coronary arteries using transthoracic Doppler echocardiography. Coronary steal occurred in half the vessels studied. There was no significant difference between coronary flow velocity reserve in poorly and well-developed collaterals.


Assuntos
Adenosina/farmacologia , Circulação Coronária/efeitos dos fármacos , Ecocardiografia Doppler , Vasodilatadores/farmacologia , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Colateral , Circulação Coronária/fisiologia , Feminino , Humanos , Masculino
18.
J Echocardiogr ; 13(1): 27-34, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25750577

RESUMO

BACKGROUND: Heart failure (HF) can be caused by left ventricular (LV) pump failure as well as by bradyarrhythmias. Hemodynamic differences between HF by LV pump failure and that by bradyarrhythmia have not been fully investigated. We hypothesized that HF by LV pump failure could be associated with both reduced cardiac output (CO) and increased LV filling pressure due to associated LV diastolic dysfunction, whereas HF by bradyarrhythmia could be associated with reduced CO but only modestly increased LV filling pressure due to the absence of LV diastolic dysfunction. METHODS: In 39 patients with HF by LV pump failure (LV ejection fraction <35%), 24 with HF by bradyarrhythmia, and 22 normal controls, LV volume, ejection fraction, stroke volume, left atrial volume, and early diastolic mitral valve flow to tissue annular velocity ratio (E/E') were measured by echocardiography. RESULTS: Compared to patients with HF by LV pump failure, those with HF by bradyarrhythmia had significantly lower heart rates, less LV dilatation, preserved LV ejection fraction, preserved stroke volume, similarly reduced cardiac index (1.8 ± 0.4 vs. 1.6 ± 0.4 L/min/m(2), n.s.), preserved LV diastolic function (E') (4.4 ± 2.1 vs. 7.1 ± 2.9 cm/s, p < 0.001), less dilated end-systolic LA volume, and preserved E/E' (24 ± 10 vs. 13 ± 7, p < 0.001). CONCLUSIONS: HF by LV pump failure is characterized by both significantly reduced CO and increased LV filling pressure, whereas HF by bradyarrhythmia is characterized by a similar reduction in CO but only modestly increased LV filling pressure.


Assuntos
Bradicardia/complicações , Débito Cardíaco , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Disfunção Ventricular Esquerda/complicações , Idoso , Idoso de 80 Anos ou mais , Bradicardia/diagnóstico por imagem , Diástole , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Pressão Ventricular
19.
J Am Soc Echocardiogr ; 15(10 Pt 2): 1290-6, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12411919

RESUMO

The purpose of this study was to determine the relationship between coronary flow velocity (CFV) measured by transthoracic Doppler echocardiography (TTDE) and wall motion during dobutamine stress echocardiography (DSE) in patients with resting wall motion abnormalities (WMAs). One hundred fifty patients with resting WMA in the left anterior descending coronary artery (LAD) territory underwent CFV recording in the distal LAD by TTDE during contrast-enhanced DSE. Regional wall motion, CFV, and CFV ratio, defined as a ratio of CFV at each stage of dobutamine stress to basal CFV, were obtained. Patients were divided into 4 groups (sustained improvement, biphasic response, worsening response, and no change). CFV was successfully recorded in 129 patients during DSE (86%). The mean value of basal CFV did not differ among the 4 groups. Although CFV ratio during DSE progressively increased in patients with sustained improvement, this increase was blunted with biphasic response and almost lost with worsening or no change response (P <.001, ANOVA). CFV ratio at peak stress was significantly higher in patients with sustained improvement (2.73 +/- 0.69) than that with the other 3 groups (P <.001). The value with biphasic response (1.68 +/- 0.56) was also higher than that with worsening (0.98 +/- 0.15, P <.005) and no change (1.28 +/- 0.38, P <.08). The simultaneous assessment of CFV and function in the LAD territory is feasible, and flow and function are closely correlated. TTDE provides flow information that may complement conventional echocardiographic assessment of myocardial viability.


Assuntos
Agonistas Adrenérgicos beta , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Coronários/fisiopatologia , Dobutamina , Ecocardiografia sob Estresse , Contração Miocárdica/efeitos dos fármacos , Contração Miocárdica/fisiologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/efeitos dos fármacos , Diagnóstico Diferencial , Relação Dose-Resposta a Droga , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Sensibilidade e Especificidade , Estatística como Assunto , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia
20.
J Am Soc Echocardiogr ; 16(6): 614-21, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12778021

RESUMO

The diagnostic accuracy of dobutamine stress echocardiography (DSE) depends on wall-motion assessment. Coronary flow velocity reserve (CFVR) during DSE can be measured by transthoracic Doppler echocardiography. To investigate comparative diagnostic accuracy between wall-motion and CFVR assessment in the detection of significant left anterior descending coronary artery (LAD) stenosis, 274 patients underwent both contrast-enhanced DSE and coronary angiography. Intravenous contrast agent, Levovist, was injected to enhance left ventricular endocardial border delineation and coronary flow velocity in the LAD. Wall motion was assessed by standard technique, and CFVR was calculated as coronary flow velocity at peak dobutamine stress divided by baseline coronary flow velocity by transthoracic Doppler echocardiography. CFVR could be successfully obtained in 232 patients (feasibility, 85%). After excluding 14 patients with isolated diagonal stenosis, CFVR was significantly lower in 65 patients with significant LAD stenosis than it was in 153 patients without stenosis (1.62 +/- 0.56 vs 2.72 +/- 0.94, P <.001). CFVR < or = 2.0 had a 75% sensitivity, a 81% specificity, and a 79% diagnostic accuracy for detecting significant LAD stenosis, and these values were comparable with those by wall-motion analysis (sensitivity, 78%; specificity, 89%; and diagnostic accuracy, 86%). The measurement of CFVR in the LAD during DSE was feasible and the diagnostic accuracy of CFVR was equivalent to wall-motion assessment in the detection of LAD stenosis.


Assuntos
Circulação Coronária/fisiologia , Estenose Coronária/diagnóstico por imagem , Ecocardiografia sob Estresse , Contração Miocárdica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissacarídeos , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA